Note: An arrow (Æ) found in the text signifies change in content.
WARNING!
Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this
manual. For assistance or additional information, consult a qualified installer, service agency or the gas supplier.
01/0435040 Rev E1
RHW-56 INSTALLATION INSTRUCTIONS
TABLE OF CONTENTS
Design and Installation Considerations .......................................................................................................... 3
A. Listings and Code Approvals .......................................................................................................................... 4
B. Description of the Fireplace System ............................................................................................................... 4
C. System Components ...................................................................................................................................... 5
D. Pre-Installation Preparation ............................................................................................................................ 9
E. Chimney Requirements ................................................................................................................................. 11
F.Installation of Fireplace ................................................................................................................................ 13
G. Constructing a Chase ................................................................................................................................... 20
H. Operating Instructions .................................................................................................................................. 22
Index ............................................................................................................................................................. 27
Do not expose the fireplace to the elements (i.e. rain, etc.) and keep the fireplace dry at all times. Wet insulation
will produce an odor when the fireplace is used.
WARNING!
This appliance is tested and listed for use only with the optional accessories listed in these instructions. Use
of optional accessories not specifically tested for this appliance could void the warranty and/or result in a
safety hazard.
Safety Precautions
1. Please read these installation instructions completely before beginning installation procedures. Failure to follow
them could cause a fireplace malfunction resulting in serious injury and/or property damage.
2. Always check your local building codes prior to installation. The installation must comply with all local, regional,
state and national codes and regulations.
3. An adequate supply of replacement combustion air from outside the house must be available to the fire for the
fireplace to operate properly. To achieve this, the use of the optional outside air kit is highly recommended.
In the event the home is unusually tightly sealed, the optional combustion air kit may not provide all the air required
to support combustion. Hearth & Home Technologies is not responsible for any smoking or related problems that
may result from the lack of adequate combustion air. It is the responsibility of the builder/contractor to ensure that
adequate combustion air has been provided for the fireplace.
4. The fireplace must be installed with the Hearth & Home Technologies SL Series Chimney System.
The chimney system must always terminate outside the building. Be sure to follow all chimney specifications given
in these installation instructions.
5. NEVER leave children unattended when there is a fire burning in the fireplace.
6. This fireplace is built for solid fuel only. NEVER use gasoline, gasoline type lantern fuel, kerosene, charcoal light
fluid, or similar liquids in this fireplace. Keep any flammable liquids a safe distance from the fireplace.
7. DO NOT use chimney cleaners or flame colorants in your fireplace.
8. The flue damper must be open at all times when the fireplace is in use.
9. While servicing this fireplace, always shut off any electricity or gas to the fireplace. This will prevent possible electric
shock or burns. Also, make sure the fireplace is completely cooled before servicing.
10. To ensure a safe fireplace system and to prevent the build up of soot and creosote, inspect and clean the fireplace
and chimney prior to use and periodically during the burning season. See Maintenance Instructions in this manual
for cleaning instructions.
235040 Rev E01/04
RHW-56 INSTALLATION INSTRUCTIONS
DESIGN AND INSTALLATION CONSIDERATIONS
When selecting a location for your woodburning fireplace, it is important to evaluate a number of considerations. Modern
construction techniques can create conditions that may not allow your chimney to draft properly. This may result in
smoke spillage from your fireplace, as well as cause other combustion appliances to operate incorrectly.
Tightly sealed construction is important for energy efficiency. Unfortunately, a great deal of effort has been directed to
tightening up sidewall construction, while considerably less attention has been paid to tightening upper portions of the
warm air envelope (insulated ceilings). This has increased the Stack Effect, a condition that increases the negative
pressure generated by the structure. This negative pressure will directly affect the drafting performance of a fireplace
chimney. To minimize the negative pressure generated by stack effect, make certain that all ductwork installed in the attic
spaces is sealed airtight. Minimize the number of recessed light fixtures installed in the insulated ceiling, and use
sealed recessed light fixtures. Finally, make certain the whole house fans and attic access panels are tightly sealed.
These are important design considerations that must be observed during the design and construction stage of the
home.
If you desire to put a fireplace in your basement, we recommend that you consider a direct vent gas fireplace. Basements
always have a significant negative air pressure that causes the fireplace system to be more susceptible to smoke
spillage and cold flue backdrafting. Since direct vent gas fireplaces are sealed, they are not affected by the negative
pressure that exists in basements.
Finally, woodburning fireplaces perform best when their chimney (roof termination) is located on the upper half of the
roof, especially when cathedral ceilings are present. Chimneys that are located on the lower half of the roof realize what
is known as lazy flue and will not draft as well as a chimney that is located in the upper portion of the roof. The reason
for this is that the stack effect generated by the overall height of the living spaces inside the house will exceed the draft
generated by the chimney system. If you desire to place a woodburning fireplace in a location where the termination cap
would be located on the lower half of a roof, such as on an outside wall at the base of a cathedral ceiling, we recommend
that you consider using a direct vent gas fireplace. This will assure the homeowner a fireplace that operates correctly.
These properties do not affect just your woodburning factory-built fireplace. They can cause any woodburning fireplace
as well as any conventionally vented (B-vent) gas appliance to operate improperly. Careful planning at this stage of your
project will ensure satisfaction with the operation of your fireplace once it is completed.
01/0435040 Rev E3
RHW-56 INSTALLATION INSTRUCTIONS
A. LISTINGS AND CODE APPROVALS
This fireplace system has been tested and listed in
accordance with UL 127 standards, and has been listed by
Underwriters Laboratories Inc. for installation and operation
in the United States as described in this manual.
This fireplace has been tested and listed for use with the
optional components listed on page 5. These optional
components may be purchased separately and installed at
a later date. However, installation of an outside air kit will
require significant reconstruction, and should be installed
at the time of the initial fireplace installation.
Check with your local building code agency prior to
installing this fireplace to ensure compliance with local
codes, including the need for permits and follow-up
inspections. If you need assistance during installation,
please contact your local dealer or the Heat-N-Glo
Technical Services Department, Hearth & Home
Technologies Inc., 1-888-427-3973.
Heat-N-Glo
Technologies Inc.
®
is a registered trademark of Hearth & Home
Æ
WARNING!
This fireplace and its components are designed to be installed and operated as a system. Any alteration to or
substitution for items in this system, unless allowed by these installation instructions, will void the Underwriters Laboratories listing and may void the product warranty. It may also create a hazardous installation. Read
through these instructions thoroughly before starting your installation and follow them carefully throughout
your project.
B. DESCRIPTION OF THE FIREPLACE SYSTEM
1.The Heat-N-Glo fireplace system consists of the following:
a.Fireplace/Integral Grate/Outside Combustion Air System
b. Refractory
c.Chimney Termination Cap
d. Chimney System
e.Hearth Extension
2.Optional Components Include:
a.Glass Doors
b. Chimney Air Kit
Note: Illustrations used throughout these instructions
reflect typical installations and are for design purposes
only. Actual installation may vary slightly due to individual
design preferences. However, minimum and maximum
clearances must be maintained at all times.
The illustrations and diagrams used throughout these
installations instructions are not drawn to scale.
The following pictures show only those chimney components which may be safely used with this fireplace.
#golataC:noitpircseD
41KA)ecalperiFhtiwdedulcni(tiKriAedistuO
A5KACtiKriAyenmihC
4DIriAedistuO/tcuDdetalusnI
4DUriAedistuO/tcuDdetalusninU
6011LSgnol"6-noitceSyenmihC
2111LSgnol"21-noitceSyenmihC
8111LSgnol"81-noitceSyenmihC
6311LSgnol"63-noitceSyenmihC
8411LSgnol"84-noitceSyenmihC
11LSrezilibatSyenmihC
0311LS°03-nruteR/tesffOyenmihC
thgiartS-potseriF
Æ
835SF
045SF°03-potseriF
01SA"42,dleihSnoitalusnIcittAthgiartS
775BJdnaBtnioJyenmihC
675BCtekcarByenmihC
075FRhctiP21/6ottalF-gnihsalFfooR
175FRhctiP21/21ot21/6-gnihsalFfooR
11RTpaCnoitanimreTdnuoR
T11RTpaCnoitanimreTgnipocseleTdnuoR
5711TSpaCnoitanimreTerauqS
5711TCTpaCnoitanimreTattoCarreT
65TCpoTesahC
33SDL'3x'3-duorhSevitaroceD
64SDL'6x'4-duorhSevitaroceD
AK14 - Outside Air Kit
635040 Rev E01/04
RHW-56 INSTALLATION INSTRUCTIONS
Chimney Sections
#golataCAB
6011LS"6"¾4
2111LS"21"¾01
8111LS"81"¾61
6311LS"63"¾43
8411LS"84"¾64
=AhtgnellautcA
=Bfohtgnel(htgnelevitceffE
sahtiretfatrapyenmihc
)rehtonaotdeppansneeb
SL11 - Chimney Stabilizer
SL1130 - Offset/Return
Firestop Spacer
#golataCAB
835SF°0"71
045SF°03"62
CB576
Chimney Bracket
01/0435040 Rev E7
RF570 - Roof Flashing
Flat to 6/12 Pitch
JB577
Joint Band
RF571 - Roof Flashing
6/12 to 12/12 Pitch
AS10
Straight Attic
Æ
Insulation Shield
LDS33 (3 x 3)
LDS46 (4 x 6)
Decorative Shroud
RHW-56 INSTALLATION INSTRUCTIONS
ST1175
Square Termination
Cap
TCT1175
Æ
Terra Cotta
Termination Cap
CT56
Chase Top
TR11
Round
Termination Cap
TR11T
Round Telescoping
Termination Cap
CAK5A
Chimney Air Kit
835040 Rev E01/04
RHW-56 INSTALLATION INSTRUCTIONS
D. PRE-INSTALLATION PREPARATION
1. Fireplace Locations and Space Requirements
Several options are available to you when choosing a location for your fireplace. This fireplace may be used as a
room divider, installed along a wall, across a corner or used in an exterior chase. See Figure 2.
Locating the fireplace in a basement, near frequently opened doors, central heat outlets or returns, or other locations
of considerable air movement can affect the performance and cause intermittent smoke spillage from the front of the
fireplace. Consideration should be given to these factors before deciding on a location.
Figures 3 and 4 show two typical installations assuming an outside air kit is being used. Therefore, an allowance must
be made for 90° bends. Less space is required when ducting goes directly outside without forming elbows.
CLEARANCES!
A minimum 1½ air clearance
must be maintained at the
back and sides of the
fireplace assembly except at
the nailing flange where the
clearance is ½.
Chimney sections at any level
require a 2 minimum air
space clearance between the
framing and chimney section.
Figure 2 - Fireplace Locations
These are
rough
framing
dimensions
only.
Installation Along a Wall or an Exterior Chase
Figure 3
Figure 4
Corner Installation
WARNING!
Do not draw outside air from garage spaces. Exhaust products of gasoline engines are hazardous.
Do not install outside air ducts such that the air may be drawn from attic spaces, basements or above the
roofing where other heating appliances or fans and chimneys exhaust or utilize air. These precautions will
reduce the possibility of fireplace smoking or air flow reversal.
WARNING!
To prevent contact with sagging or loose insulation, the fireplace must not be installed against vapor barriers
or exposed insulation. Localized overheating could occur and a fire could result.
01/0435040 Rev E9
Loading...
+ 19 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.