Heat & Glo RHW-44 Installation and operation guide

Heat-N-Glo, a Division of Hearth Technologies Inc.
Lakeville, MN 55044
RHW-44
WOODBURNING FIREPLACE
INSTALLATION & OPERATING
INSTRUCTIONS
FOR RESIDENTIAL USE
Plumber: Please refer to page 18 for gas connection information. Framer: Please refer to page 9 for framing specifications.
RHW-44 WOODBURNING FIREPLACE
PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE.
Table of Contents
A. Listings and Code Approvals......................................................................................................................3
B. Description of the Fireplace System..........................................................................................................3
C. Fireplace System Components...................................................................................................................4
D. Pre-Installation Preparation ........................................................................................................................8
1. Fireplace Locations and Space Requirements.........................................................................................8
2. Framing The Fireplace.............................................................................................................................9
3. Hearth Extensions..................................................................................................................................10
4. Sidewalls/Surrounds...............................................................................................................................11
5. Mantel.....................................................................................................................................................11
E. Chimney Requirements .............................................................................................................................11
1. Using Offsets and Returns.....................................................................................................................11
2. Chimney Height Requirements ..............................................................................................................13
3. Determining the Number of Chimney Sections Required.......................................................................13
F. Step-By-Step Installation of the Fireplace System..................................................................................14
G. Constructing a Chase................................................................................................................................19
1. Materials For The Chase........................................................................................................................19
2. Installing a Terminal Cap on a Chase-Enclosed Chimney.....................................................................20
H. Operating Instructions...............................................................................................................................20
Safety Precautions:
1. Please read these installation instructions com-
pletely before beginning installation procedures. Failure to follow them could cause a fireplace malfunction resulting in serious injury and/or prop­erty damage.
2. Always check your Local Building Codes prior to installation. The installation must comply with all Local, Regional, State and National Codes and regulations.
3. An adequate supply of replacement combustion air from outside the house must be available to the fire for the fireplace to operate properly. To achieve this, an optional outside air kit is highly recommended.
In the event the home is unusually tight, the optional combustion air kit may not provide all the air required to support combustion. Heat-N-Glo is not responsible for any smoking or related prob­lems that may result from the lack of adequate combustion air. It is the responsibility of the builder/contractor to ensure that adequate com­bustion air has been provided for the fireplace.
4. The RHW-44 woodburning fireplace must be installed with the Hearth Technologies Inc. (HTI) SL300 Series chimney system.
The chimney system must always terminate out­side the building. Be sure to follow all chimney specifications given in these installation instruc­tions.
5. NEVER leave children unattended when there is a fire burning in the fireplace.
6. This fireplace is built for solid fuel only. NEVER use gasoline, gasoline type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids in this fireplace. Keep any flammable liquids a safe distance from the fireplace.
7. DO NOT use chimney cleaners or flame colorants in your fireplace.
8. The flue damper must be open at all times when the fireplace is in use.
9. While servicing this fireplace, always shut off any electricity or gas to the fireplace. This will prevent possible electrical shock or burns. Also, make sure the unit is completely cooled before servic­i n g .
10. To ensure a safe fireplace system and to prevent the buildup of soot and creosote, inspect and clean the fireplace and chimney prior to use and periodically during the burning season.
3-00 2 33147A
RHW-44 WOODBURNING FIREPLACE
A. LISTINGS AND CODE APPROVALS
The RHW-44 fireplace system has been tested and listed in accordance with UL 127 and ULC S610 Standards, and has been listed by Underwriters Laboratories Inc. for installation and operation in the United States and Canada as described in these Installation & Operating Instructions.
The model RHW-44 fireplace has been tested and listed for use with the components listed below. The optional components may be purchased separately and installed at a later date. However, installation of
an outside air kit will require significant reconstruc­tion, and should be installed at the time of the initial fireplace installation.
Check with your Local Building Code Agency prior to installing this fireplace to ensure compliance with local Codes, including the need for Permits and follow up inspections. If any assistance is required during installation, please contact your local dealer or the Heat-N-Glo Technical Services Department, 20802 Kensington Blvd., Lakeville, MN 55044.
WARNING!
THIS HEAT-N-GLO FIREPLACE AND ITS COMPONENTS ARE DESIGNED TO BE
INSTALLED AND OPERATED AS A SYSTEM. ANY ALTERATION TO OR
SUBSTITUTION FOR ITEMS IN THIS SYSTEM, UNLESS ALLOWED BY THESE
INSTALLATION INSTRUCTIONS, WILL VOID THE UNDERWRITERS LABORATORIES
LISTING AND MAY VOID THE PRODUCT WARRANTY. IT MAY ALSO CREATE A
HAZARDOUS INSTALLATION. READ THROUGH THESE INSTRUCTIONS
THOROUGHLY BEFORE STARTING YOUR INSTALLATION AND FOLLOW THEM
CAREFULLY THROUGHOUT YOUR PROJECT.
B. DESCRIPTION OF THE FIREPLACE SYSTEM
This Heat-N-Glo fireplace system consists of the following:
1. Fireplace/Integral Grate 3. Chimney System
2. Chimney Termination Cap 4. Hearth Extension
Optional components include:
1. Glass Doors
2. Outside Combustion Air System
NOTE: Illustrations throughout these instructions reflect “typical installations” and are for design purposes only. Actual installation may vary slightly due to indi­vidual design preferences. However, minimum and maximum clearances must be maintained at all times.
The illustrations and diagrams used throughout these installation instructions are not drawn to scale.
Tools and Building Supplies Normally Required
Tools: Building Supplies:
Saw Hearth Extension Material Pliers Wall-finishing Materials Hammer Framing Material Phillips Screwdriver Fireplace Surround Tape Measure Caulking Material Plumb Line Level Electric Drill and Bits Framing Square
3-00 3 33147A
RHW-44 WOODBURNING FIREPLACE
HTI Cat.# Description
RHW-44* Fireplace, includes outside air kit, integral grate and hearth protection strips HX3 Hearth Extension DM1136 Original Bi-fold Glass Doors - Black Finish DM1136A Original Bi-fold Glass Doors - PolishedBrass Finish DM1136B Original Bi-fold Glass Doors - Bright Brass Finish C1136A Classic Bi-fold Glass Doors - Brushed Brass Finish C1136B Classic Bi-fold Glass Doors - Polished Brass Finish C1136C Classic Bi-fold Glass Doors - Chrome Finish C2136A Classic Cabinet Glass Doors - Brushed Brass Finish C2136B Classic Cabinet Glass Doors - Polished Brass Finish C2136C Classic Cabinet Glass Doors - Chrome Finish P1136B Premium Series Bi-fold Glass Doors - Polished Brass Finish GR8 Integral Grate (included with Fireplace) ID4 Insulated Duct/Outside Air UD4 Uninsulated Duct/Outside Air CAK4 Chimney Air Kit SL306 Chimney Section - 6” long SL312 Chimney Section - 12” long SL318 Chimney Section - 18” long SL324 Chimney Section - 24” long SL336 Chimney Section - 36” long SL348 Chimney Section - 48” long SL3 Chimney Stabilizer SL315 Chimney Offset/Return - 15° SL330 Chimney Offset/Return - 30° FS338 Firestop - Straight FS339 Firestop - 15° FS340 Firestop - 30° AS8 SL300 Straight Attic Insulation Shield - 24" JB877 Chimney Joint Band CB876 Chimney Bracket RF370 Roof Flashing - Flat to 6/12 Pitch RF371 Roof Flashing - 6/12 to 12/12 Pitch ST375 Chimney Terminal Cap - Square CT35 Chase Top TR342 Round Telescoping Terminal Cap TR344 Round Telescoping Terminal Cap TS345 Square Terminal Cap TS345P Square Terminal Cap - Painted
*Heat-N-Glo Catalog Number
The table below, together with the following pictures, show only those components which may be safely used with this fireplace.
C. FIREPLACE SYSTEM COMPONENTS
3-00 4 33147A
RHW-44 WOODBURNING FIREPLACE
HEARTH EXTENSION GLASS DOORS INSULATION SHIELD
STRAIGHT ATTIC
HX3
INTEGRAL GRATE
GR8
AS8
OUTSIDE AIR KIT (SUPPLIED)
AK14
3-00 5 33147A
RHW-44 WOODBURNING FIREPLACE
HTI CAT.# A
SL315 15° SL330 30°
HTI CAT.# A B
SL306 6" 43/4" SL312 12" 103/4" SL318 18" 163/4" SL324 24" 223/4" SL336 36" 343/4" SL348 48" 463/4"
CHIMNEY SECTIONS CHIMNEY STABILIZER OFFSETS/RETURNS
A=Actual length B=Effective length (length of chimney part
after it has been snapped to another)
SL3
FIRESTOP SPACERS
CAT. # A B
FS338 141/2" FS339 15° 183/8" FS340 30° 23"
CHIMNEY BRACKET
Flat to 6/12 Pitch
JOINT BAND
ROOF FLASHING
RF370
RF371
6/12 to 12/12 Pitch
CHIMNEY AIR KIT
CB876
JB877
CAK4
3-00 6 33147A
RHW-44 WOODBURNING FIREPLACE
CHIMNEY TERMINAL CAPS & VENT SECTIONS
TR342
ROUND TELESCOPING
TERMINAL CAP
TR344
ROUND TERMINAL CAP
WITH STORM COLLAR
TS345/345P
SQUARE TERMINAL CAP
ST375
SQUARE TERMINAL CAP
CT35
CHASE TOP
3-00 7 33147A
RHW-44 WOODBURNING FIREPLACE
A B C D
78
3
/4 393/8 171/4 555/8
allowance must be made for 90° bends. Less space is required when ducting goes directly outside without form­ing elbows.
Several options are available to you when choosing a location for your fireplace. This fireplace may be used as a room divider, installed along a wall, across a corner or used in an exterior chase. See Figure 1.
D. PRE-INSTALLATION PREPARATION
1. FIREPLACE LOCATIONS AND SPACE REQUIREMENTS
Figure 1
Fireplace Locations
Figures 2 and 3 show two typical installations assuming an outside air kit is being used. Therefore, an
* A minimum of 1/2" air clearance must be maintained between the firebox and wall.
WITH OR WITHOUT
OUTSIDE AIR
Figure 2
Installation along a wall or an
exterior chase.
Figure 3
Corner Installation
WARNING!
DO NOT DRAW OUTSIDE AIR FROM GARAGE SPACES. EXHAUST PRODUCTS OF GASOLINE ENGINES ARE HAZARDOUS.
DO NOT INSTALL OUTSIDE AIR DUCTS SUCH THAT THE AIR MAY BE DRAWN FROM ATTIC SPACES, BASEMENTS OR ABOVE THE ROOFING WHERE OTHER HEATING APPLIANCES OR FANS AND CHIMNEYS EXHAUST OR UTILIZE AIR. THESE PRECAUTIONS WILL REDUCE THE POSSIBILITY FOR SMOKING OR FLOW REVERSAL.
WARNING!
TO PREVENT CONTACT WITH SAGGING OR LOOSE INSULATION, THE FIREPLACE
MUST NOT BE INSTALLED AGAINST VAPOR BARRIERS OR EXPOSED INSULA-
TION. LOCALIZED OVERHEATING COULD OCCUR AND A FIRE COULD RESULT.
3-00 8 33147A
Loading...
+ 16 hidden pages