Heat & Glo PALOMA-BL, PALOMA-BZ, PALOMA-GR, PALOMA-GY Owner’s Manual

Model(s): PALOMA-BL PALOMA-BZ PALOMA-GR PALOMA-GY
Owner’s Manual
Installation and Operation
Tested and
Listed by
O-T L
C
OMNI-Test Laboratories, Inc.
Oregon USA
US
Portland
CAUTION
DO NOT DISCARD THIS MANUAL
• Important operating and maintenance instructions included.
WARNING: If the information in these instructions is not followed exactly, a fi re or explosion may result causing property damage, personal injury, or death.
• Do not store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance.
- Do not try to light any appliance.
- Do not touch any electrical switch. Do not
use any phone in your building.
- Immediately call your gas supplier from a
neighbor’s phone. Follow the gas suppli­er’s instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed by a qualifi ed installer, service agency , or the gas supplier.
• Read, understand and follow these instructions for safe installation and operation.
DO NOT
DISCARD
• Leave this manual with party responsible for use and operation.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during operation AND cool down.
Hot glass will cause burns.
• Do not touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as replace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other fl ammable materials.
• Keep clothing, furniture, draperies and other fl ammable materials away.
In the Commonwealth of Massachusetts:
• installation must be performed by a licensed plumber or gas fi tter;
See Table of Contents for location of additional Commonwealth of Massachusetts requirements.
This appliance may be installed as an OEM installation in manufactured home (USA only) or mobile home and must be installed in accordance with the manufacturer’s instructions and the manufactured home construction and safety standard, Title
24 CFR, Part 3280 or Standard for Installation in Mobile Homes, CAN/CSA Z240MH.
This appliance is only for use with the type(s) of gas indicated on the rating plate.
Heat & Glo • Paloma • 7031-220 Rev. S • 8/09 1
Installation and service of this appliance should be performed by qualifi ed personnel. Hearth & Home Technologies suggests NFI certifi ed or factory trained professionals, or technicians supervised by an NFI certifi ed professional.
Read this manual before installing or operating this appliance.
Please retain this owner’s manual for future reference.
Congratulations
Congratulations on selecting a Heat & Glo gas appliance —an elegant and clean alternative to wood burning appliances. The Heat & Glo gas appliance you have selected is designed to provide the utmost in safety, reliability, and effi ciency.
As the owner of a new appliance, you’ll want to read and carefully follow all of the instructions contained in this Owner’s Manual. Pay special attention to all Cautions and Warnings.
Homeowner Reference Information
This Owner’s Manual should be retained for future reference. We suggest that you keep it with your other important documents and product manuals.
The information contained in this Owner’s Manual, unless noted otherwise, applies to all models and gas control systems.
Your new Heat & Glo gas appliance will give you years of durable use and trouble-free enjoyment. Welcome to the Heat & Glo family of appliance products!
We recommend that you record the following pertinent information about your appliance.
Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ Location on appliance: ____________________ Dealership purchased from: _______________________________ Dealer Phone: __________________________ Notes: _______________________________________________________________________________________ _____________________________________________________________________________________________
Listing Label Information/Location
Test Lab & Report No.
Tested and
Listed by
OMNI-Test Laboratories, Inc.
Report No. / Rapport Numero
FAN TYPE VENTED CIRCULATOR Blower Electrical Rating115 V., 1.5 Amps, 60 Hz, 150 Watts
APPROVED FOR CANADA AND USA TO: ANSI Z21.88b-2003 / CSA 2.33b-2003 Vented Gas Fireplace Heater, and applicable sections of UL307b Gas Burning Heating Appliances for Manufactured Homes and Recreational Vehicles, CAN/CG A 2.17-M91 “Gas Fired Appliances for use at High Altitudes.” This appliance is manufactured for operation with Natural Gas. For conversion to propane the Manufacturer’s kit provided with the stove must be used in conjuntion with the instructions in the owner's manual. This vented gas fireplace heater is not for use with air filters. This appliance may be installed in a bedroom or bedsitting room; in Canada remote thermostat installation is required.
Input Rate on “HI” (BTU/Hr) 30,000 28,000 Input Rate on “LO” (BTU/Hr) 22,500 22,650 Main Burner Orifice (DMS) 36 52 Minimum Inlet Pressure (Inches W.C.) 4.5” 11” Maximum Inlet Pressure (Inches W.C.) 7.0” 14” Manifold Pressure on “HI” (Inches W.C.) 3.5” 10” Efficiency up to 82.5% 81% AFUE 71% 72.5%
This appliance equipped for altitudes 0-2000’ (0-610m) in USA; and in Canada for altitudes of 0-4500’ (0-1370m). In USA for Altitudes above 2000’, the vent configuration, orifice, or combination of both may need to be changed. See Owner’s Manual for information on making these changes.
This appliance must be installed in accordance with local codes, if any (and Commonwealth of Massachusetts approved); if none, follow The National Fuel Gas Code,ANSI Z223.1 and NFPA 54; or Canadian Installation Codes CAN/CGA-B149. NOTE: Have the gas supply line installed in accordance with local building codes by a qualified installer approved and/or licensed as required by the locality. (In the Commonwealth of Massachusetts, installation must be performed by a licensed plumber or gas fitter.)
The model information regarding your specifi c appliance can be found on the rating plate usually located in the control area of the appliance.
SERIAL
Beaverton
Oregon USA
C
061-S-63-5
SAMPLE
MINIMUM CLEARANCES TO COMBUSTIBLES
007
NO.
MODEL: PALOMA
VENTED GAS
NOT FOR USE WITH SOLID FUE
P.4.1-02 Canada Minimum Pipe 69% NG / 71% LP
For use with Natural Gas For use with Propane
APPLIANCE
L
"0-2000’ "0-2000’
800 West Jefferson Street
Lake City, MN 55041
www.heatnglo.com
Serial No.
Model Name
Manufactured by:
2005 2006 2007 Feb Mar Apr May Jun Jul Aug Sep Oct Nov DecJan
Heat & Glo • Paloma • 7031-220 Rev. S • 8/092
Date of Manufacture / Date du Manufacturier
DO NOT REMOVE THIS LABEL
MADE IN U.S.A.
Manufactured Date
Table of Contents
1 Listing and Code Approvals
A. Appliance Certifi cation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
B. Glass Specifi cations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
C. BTU Specifi cations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
D. High Altitude Installations . . . . . . . . . . . . . . . . . . . . . . . . . . 4
E. Non-Combustible Materials Specifi cation. . . . . . . . . . . . . . 4
F. Combustible Materials Specifi cation . . . . . . . . . . . . . . . . . 4
G. Electrical Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
H. Requirements for the Commonwealth of Massachusetts . . 5
2 Getting Started
A. Design and Installation Considerations . . . . . . . . . . . . . . . 6
B. Tools and Supplies Needed . . . . . . . . . . . . . . . . . . . . . . . . 6
C. Inspect Appliance and Components . . . . . . . . . . . . . . . . . . 6
3 Framing and Clearances
A. Selecting Appliance Location . . . . . . . . . . . . . . . . . . . . . . . 7
B. Clearances to Combustibles . . . . . . . . . . . . . . . . . . . . . . . 7
C. Optional Stone Surround Installed . . . . . . . . . . . . . . . . . . . 8
4 Termination Locations
A. Vent Termination Minimum Clearances . . . . . . . . . . . . . . . 9
5 Vent Information
A. Venting Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
B. Use of Elbows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
C. Measuring Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
D. How to Use the Vent Graph . . . . . . . . . . . . . . . . . . . . . . . 12
E. Venting Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
F. Horizontal Termination . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
G. Vertical Termination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
H. Cathedral Ceiling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
I. Class A Metal Chimney . . . . . . . . . . . . . . . . . . . . . . . . . . 20
J. Existing Masonry Chimney . . . . . . . . . . . . . . . . . . . . . . . . 21
K. Slim Line Wall Thimble . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
6 Gas Information
A. Fuel Conversions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
B. Converting to LP Gas . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
C. Gas Pressures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
D. Gas Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
8 Appliance Setup
A. Remove Shipping Materials . . . . . . . . . . . . . . . . . . . . . . . 33
B. Unbolting Appliance from the Pallet . . . . . . . . . . . . . . . . . 33
C. Leveling and Lagging Down the Appliance . . . . . . . . . . . 34
D. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
E. Top to Rear Vent Conversion . . . . . . . . . . . . . . . . . . . . . . 35
F. Shutter Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
G. Installing the Vent Restrictor. . . . . . . . . . . . . . . . . . . . . . . 36
H. Installing the Baffl e . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
I. Positioning the Logs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
J. Mineral Wool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
K. Optional Blower . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
L. Remote Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
M. Front Door Glass Assembly Installation . . . . . . . . . . . . . . 44
N. Inner Glass Door Assembly Replacement . . . . . . . . . . . . 44
9 Operating Instructions
A. Before Lighting Appliance. . . . . . . . . . . . . . . . . . . . . . . . . 45
B. Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
C. Lighting Appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
D. After Appliance is Lit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
E. Frequently Asked Questions . . . . . . . . . . . . . . . . . . . . . . 47
10 Troubleshooting
A. IntelliFire Ignition System . . . . . . . . . . . . . . . . . . . . . . . . . 48
11 Maintaining and Servicing Appliance
A. Maintenance Tasks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
12 Reference Materials
A. Appliance Dimension Diagram Without Stone Surround . 52
B. Appliance Dimension Diagram With Stone Surround. . . . 53
C. Vent Components Diagram . . . . . . . . . . . . . . . . . . . . . . . 54
D. Vent Components List . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
E. Service Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
F. Limited Lifetime Warranty . . . . . . . . . . . . . . . . . . . . . . . . . 60
G. Contact Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
7 Electrical Information
A. Recommendation for Wire . . . . . . . . . . . . . . . . . . . . . . . . 30
B. Connecting to the Appliance. . . . . . . . . . . . . . . . . . . . . . . 30
C. IntelliFire® Ignition System Wiring . . . . . . . . . . . . . . . . . . 30
D. Loss of Power and Battery Backup Usage . . . . . . . . . . . . 31
E. Wall Switch Installation for Fan (Optional) . . . . . . . . . . . . 32
Î = Contains updated information.
Heat & Glo • Paloma • 7031-220 Rev. S • 8/09 3
1
1
Listing and Code Approvals
A. Appliance Certifi cation
MODELS: Paloma LABORATORY: Omni Test Laboratories, Inc. TYPE: Vented Gas Fireplace Heater STANDARD: ANSI Z21.88B-2003 • CSA 2.33-2003 • UL307B
CAN/CBA 2.17-M91
This product is listed to ANSI standards for “Vented Gas Appliance Heaters” and applicable sections of “Gas Burn­ing Heating Appliances for Manufactured Homes and Recreational Vehicles”, and “Gas Fired Appliances for Use at High Altitudes”.
NOT INTENDED FOR USE AS A PRIMAR Y HEAT SOURCE.
This appliance is tested and approved as either supplemen­tal room heat or as a decorative appliance. It should not be factored as primary heat in residential heating calculations.
Manufactured Home or Mobile Home installation may occur only after the home is site located and must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or, when such a standard is not applicable, the Standard for Manufactured Home Installations, ANSI/NCSBCS A225.1, or Standard for Gas Equipped Recreational Vehicles and Mobile Housing, CSA Z240.4.
When installed, the appliance must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.
B. Glass Specifi cations
This appliance is equipped with 5 mm ceramic glass behind the curved glass. Replace glass only with 5 mm ceramic glass. Please contact your dealer for replace­ment glass.
Note: This installation must conform with local codes. In the absence of local c odes you must comply w ith the National Fuel Gas Code, ANSI Z223.1 -latest edition in the U.S.A. and the CAN/CGA B149 Installation Codes in Canada.
C. BTU Specifi cations
Model
(US or Canada)
Paloma (NG) 30,000 22,500 36 82.5 69
Paloma (LP) 28,000 22,650 52 81 71
Maximum
Input
BTU/h
Minimum
Input
BTU/h
Orifi ce
Size
(DMS)
*Steady
State
Effi ciency %
**P.4
%
D. High Altitude Installations
Omni-Test Laboratories, Inc. listed gas appliances are tested and approved without requiring changes for elevations from 0 to 2000 feet in the U.S.A. and 0 to 4500 feet in Canada.
When installing this appliance at an elevation above 2000 feet, it may be necessary to decrease the input rating by changing the existing burner orifi ce to a smaller size. Input rate should be reduced by 4% for each 1000 feet above a 2000 foot elevation in the U.S.A. If the heating value of the gas has been reduced, these rules do not apply. To identify the proper orifi ce size, check with the local gas utility.
If installing this appliance at an elevation above 4500 feet (in Canada), check with local authorities.
WARNING
Do NOT use this appliance if any part has been under water. Immediately call a qualifi ed service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
E. Non-Combustible Materials Specifi cation
Material which will not ignite and burn. Such materials are those consisting entirely of steel, iron, brick, tile, concrete, slate, glass or plasters, or any combination thereof.
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750ºC, shall be considered
non-combustible materials.
F. Combustible Materials Specifi cation
Materials made of or surfaced with wood, compressed paper, plant fi bers, plastics, or other material that can ig- nite and burn, whether fl ame proofed or not, or whether plastered or unplastered shall be considered combustible materials.
G. Electrical Codes
NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA
70-latest edition or the Canadian Electric Code CSA C22.1.
• A 110-120 VAC circuit for this product must be protected
with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks.
*Maximum Vent Blower On **Canada Only
Heat & Glo • Paloma • 7031-220 Rev. S • 8/094
Note: The following requirements reference various Massachuset ts and national codes not contained in this document.
H. Requirements for the Commonwealth of
Massachusetts
For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above fi nished grade in the area of the venting, in- cluding but not limited to decks and porches, the following requirements shall be satisfi ed:
Installation of Carbon Monoxide Detectors
At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gas fi tter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the fl oor level where the gas equipment is to be installed. In addi­tion, the installing plumber or gas fi tter shall observe that a battery operated or hard wired carbon monoxide detec­tor with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualifi ed licensed professionals for the installation of hard wired carbon monoxide detectors.
In the event that the side wall horizontally vented gas fu­eled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent oor level. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that dur­ing said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.
Inspection
The state or local gas inspector of the side wall horizon­tally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector ob­serves carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4.
Exemptions
The following equipment is exempt from 248 CMR
5.08(2)(a)1 through 4:
• The equipment listed in Chapter 10 entitled “Equip-
ment Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the Board; and
• Product Approved side wall horizontally vented gas fu-
eled equipment installed in a room or structure sep­arate from the dwelling, building or structure used in whole or in part for residential purposes.
MANUFACTURER REQUIREMENTS Gas Equipment Venting System Provided
When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:
• Detailed instructions for the installation of the venting
system design or the venting system components; and
• A complete parts list for the venting system design or
venting system.
Gas Equipment Venting System NOT Provided
When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not pro­vide the parts for venting the fl ue gases, but identifi es “special venting systems”, the following requirements shall be satisfi ed by the manufacturer:
Approved Carbon Monoxide Detectors
Each carbon monoxide detector as required in accor­dance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certifi ed.
Signage
A metal or plastic identifi cation plate shall be permanent- ly mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fu­eled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, “GAS
VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB­STRUCTIONS”.
Heat & Glo • Paloma • 7031-220 Rev. S • 8/09 5
• The referenced “special venting system” instructions
shall be included with the appliance or equipment in­stallation instructions; and
• The “special venting systems” shall be Product Ap-
proved by the Board, and the instructions for that sys­tem shall include a parts list and detailed installation instructions.
A copy of all installation instructions for all Product Ap­proved side wall horizontally vented gas fueled equip­ment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.
See Gas Connection section for additional Common­wealth of Massachusetts requirements.
2
2
Getting Started
A. Design and Installation Considerations
Heat & Glo direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside. No additional outside air source is required.
C. Inspect Appliance and Components
CAUTION
Check building codes prior to installation.
• Installation MUST comply with local, regional, state and national codes and regulations.
• Consult local building, fi re offi cials or authorities having jurisdic- tion about restrictions, installation inspection, and permits.
When planning an appliance installation, it’s necessary to determine the following information before installing:
• Where the appliance is to be installed.
• The vent system confi guration to be used.
• Gas supply piping.
• Electrical wiring.
• Framing and fi nishing details.
• Whether optional accessories—devices such as a fan, wall switch, or remote control—are desired.
• Carefully remove the appliance and components from the packaging.
• Remove door and set aside on protective surface. See page 44.
• Remove log set and component pack from fi rebox.
• Report to your dealer any parts damaged in shipment, particularly the condition of the glass.
• Read all of the instructions before starting the insta­llation. Follow these instructions carefully during the installation to ensure maximum safety and benefi t.
WARNING
Keep appliance dry.
• Mold or rust may cause odors.
• Water may damage controls.
B. Tools and Supplies Needed
Before beginning the installation be sure that the following tools and building supplies are available.
Reciprocating saw Framing material Pliers Hi temp caulking material Hammer Gloves Phillips screwdriver Framing square Flat blade screwdriver Electric drill and bits (1/4 in.) Plumb line Safety glasses Level Wrenches Ratchets/Sockets Allen Wrench Set Manometer Voltmeter Tape measure 1/2 - 3/4 inch length, #6 or #8 Self-drilling screws One 1/4 inch female connection (for optional fan) Noncorrosive leak check solution or combustible gas detector
• Installation and use of any damaged appliance or vent system component.
• Modifi cation of the appliance or vent system.
• Installation other than as instructed by Hearth & Home Technologies.
• Improper positioning of the gas logs or the glass door.
• Installation and/or use of any component part not approved by Hearth & Home Technologies.
Any such action may cause a fi re hazard.
WARNING
Inspect appliance and components for damage. Damaged parts may impair safe operation.
• Do NOT install damaged components.
• Do NOT install incomplete components.
• Do NOT install substitute components. Report damaged parts to dealer.
WARNING
Hearth & Home Technologies disclaims any responsibility for, and the warranty will be voided by, the following actions:
Heat & Glo • Paloma • 7031-220 Rev. S • 8/096
3
3
Framing and Clearances
Note:
Illustrations reflect typical installations and are FOR
DESIGN PURPOSES ONLY.
Illustrations/diagrams are not drawn to scale.
Actual installation may vary due to individual design
preference.
A. Selecting Appliance Location
When selecting a location for your appliance it is important to consider the required clearances to walls (see fi gure 3.1).
B. Clearances to Combustibles
F
B
A
WARNING
Fire Risk Provide adequate clearance:
• Around air openings
• To combustibles
• For service access Locate appliance away from traffi c areas.
NOTE: For actual appliance dimensions refer to Sec­tion 12.
I
E
K
K
C
Paloma
J
“A” MEASUREMENT IS FROM APPLIANCE TOP, NOT SIDE
ALCOVE
G
A
Model A B C D E F G H I J K
Inches 6 10-1/8 12-1/8 54 36 30-3/4 13-1/4 13-1/4 1 15-1/2 5
Millimeters 152 257 308 1372 914 781 337 337 25 394 127
A
C
H
D
Figure 3.1
Heat & Glo • Paloma • 7031-220 Rev. S • 8/09 7
C. Optional Stone Surround Installed
A
Figure 3.1
C
B
D
A
Model A B C D E F G
Inches 3-1/4 4 30-3/4 36 1 20* 4-3/4
Paloma Surround
Millimeters 83 102 781 914 25 508 121
*Distance is measured from fl ue collar to corner
E
G
F
G
It is permissible to place the appliance on carpet.
CAUTION
Some carpet materials may be sensitive to radiant heat from the appliance causing discoloration or odor.
Note: Flooring beneath appliance may reach 90 degrees plus room ambient temperature. Check with flooring manufacturer for maximum temperature allowed on flooring surfaces.
WARNING
Fire Risk.
Locate and install appliance to all clearance specifi cations in manual.
WARNING
Fire Risk. Odor Risk. Tipping Risk
• Install gas stove on a stable, level platform/ oor strong enough to support gas stove without tipping.
• USE wood fl ooring, ceramic tile, brick hearth or high pressure laminate fl ooring applied directly over the sub-fl ooring material.
Heat & Glo • Paloma • 7031-220 Rev. S • 8/098
4
4
Termination Locations
A. Vent Termination Minimum Clearances
WARNING
Fire Risk. Explosion Risk. Maintain vent clearance to combustibles as
specifi ed.
• Do not pack air space with insulation or other materials.
Failure to keep insulation or other materials away from vent pipe may cause fi re.
Measure vertical clearances from this surface.
Measure horizontal clearances from this surface.
(See Figure 4.4 for specifi c clearances)
Figure 4.1
HORIZONTAL
OVERHANG
2 FT. MIN.
GAS DIRECT VENT TERMINATION CAP
Roof Pitch H (Min.) Ft.
Flat to 6/12...........................................................1.0*
Over 6/12 to 7/12 .................................................1.25*
Over 7/12 to 8/12 .................................................1.5*
Over 8/12 to 9/12 .................................................2.0*
Over 9/12 to 10/12 ...............................................2.5
Over 10/12 to 11/12 .............................................3.25
Over 11/12 to 12/12 .............................................4.0
Over 12/12 to 14/12 .............................................5.0
Over 14/12 to 16/12 .............................................6.0
Over 16/12 to 18/12 .............................................7.0
Over 18/12 to 20/12 .............................................7.5
Over 20/12 to 21/12 .............................................8.0
* 3 foot minimum in snow regions
Figure 4.2 Minimum height from roof to lowest discharge opening
20 INCHES MIN.
LOWEST
DISCHARGE
OPENING
H (MIN.) - MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING
X
12
ROOF PITCH
IS X/ 12
VERTICAL
WALL
Figure 4.2 specifi es minimum vent heights for various pitched roofs.
6in.(minimum)upto20in.
Gas
Termination
Cap **
If using decorative cap cover(s), this distance may need to be
*
increased. Refer to the installation instructions supplied with the decorative cap cover.
In a staggered installation with both gas and wood terminations, the
**
wood termination cap must be higher than the gas termination cap.
Figure 4.3 Multiple Vertical Termination
Heat & Glo • Paloma • 7031-220 Rev. S • 8/09 9
AB
152 mm/508 mm
20 in. and over 0 in. minimum
Gas, Wood or Fuel Oil
Termination Cap
B
18 in. minimum
457 mm
A*
V
R
M
N
P
Q
(See Note 2)
T
S
Electrical
V
Service
V
S
V
D*
= VENT TERMINAL
V
A = 12 inches.................clearances above grade, veranda,
(See Note 1)
X
= AIR SUPPLY INLET
porch, deck or balcony
B = 12 inches.................clearances to window or door
that may be opened, or to perma­nently closed window. (Glass)
D* = 18 inches.................vertical clearance to unventilated
soffi t or to ventilated soffi t located above the terminal
*30 inches ................for vinyl clad soffi ts and below
electrical service
F = 9 inches..................clearance to outside corner
G = 6 inches...................clearance to inside corner
H = 3 ft. (Canada) ..........not to be installed above a gas
meter/regulator assembly within 3
feet (90 cm) horizontally from the
center-line of the regulator
I = 3 ft ...........................clearance to gas service regulator
vent outlet J = 9 inches (U.S.A.)
12 inches (Canada) clearance to non-mechanical
air supply inlet to building or the
combustion air inlet to any other
appliance K = 3 ft. (U.S.A.)
6 ft. (Canada) ...........clearance to a mechanical (pow-
ered) air supply inlet
= AREA WHERE TERMINAL IS NOT PERMITTED
L** = 7 ft. ......................... clearance above paved
(See Note 1)
sidewalk or a paved driveway located on public property
M*** = 18 inches................ clearance under veranda, porch,
deck, balcony or overhang
42 inches ............... vinyl
S = 6 inches................. clearance from sides of electri-
(See Note 5)
cal service
T = 12 inches................ clearance above electrical
(See Note 5)
service
Alcove Applications
N = 6 inches ..................non-vinyl sidewalls
12 inches ................vinyl sidewalls
P = 8 ft.
Q
MIN
1 cap 3 feet 2 x Q 2 caps 6 feet 1 x Q 3 caps 9 feet 2/3 x Q 4 caps 12 feet 1/2 x Q
Q
= # termination caps x 3 R
MIN
= (2 / # termination caps) x Q
MAX
R
MAX
ACTUAL
ACTUAL
ACTUAL
ACTUAL
ACTUAL
** a vent shall not terminate directly above a sidewalk or paved driveway
which is located between two single family dwellings and serves both dwellings.
*** only permitted if veranda, porch, deck or balcony is fully open on a
minimum of 2 sides beneath the fl oor, or meets Note 2.
NOTE 1: On private property where termination is less than 7 feet above a sidewalk, driveway, deck, porch, veranda or balcony, use of a listed cap shield is suggested. (See vents components page)
NOTE 2: Termination in an alcove space (spaces open only on one side and with an overhang) are permitted with the dimensions specifi ed for vinyl or non-vinyl siding and soffi ts. 1. There must be 3 feet minimum between termination caps. 2. All mechanical air intakes within 10 feet of a termination cap must be a minimum of 3 feet below the termination cap. 3. All gravity air intakes within 3 feet of a termination cap must be a minimum of 1 foot below the termination cap.
NOTE 3: Local codes or regulations may require different clearances.
NOTE 4: Termination caps may be hot. Consider their proximity to doors or other traffi c areas.
NOTE 5: Location of the vent termination must not interfere with access to the electrical service.
WARNING: In the U.S: V ent system termination is NOT permitted in screened porches. Y ou must follow side wall, overhang and ground clearances as stated in the instructions.
In Canada: Vent system termination is NOT permitted in screened porches. Vent system termination is permitted in porch areas with two or more sides open. You must follow all side walls, overhang and ground clearances as stated in the instructions.
Heat & Glo assumes no responsibility for the improper performance of the appliance when the venting system does not meet these
Figure 4.4 Minimum Clearances for Termination
requirements.
CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE INSTALLED.
Heat & Glo • Paloma • 7031-220 Rev. S • 8/0910
5
5
Vent Information
A. Venting Components
In order to comply with applicable codes and product warranties, use only following venting components:
• Hearth & Home Technologies (HHT)
• Simpson Dura-Vent (SDV)
DO NOT USE FIELD-FABRICATED VENTING COMPO­NENTS. Refer to the venting manufacturer’s instructions.
This product is approved to be vented either horizontally, through the side wall or vertically through the roof. You may vent through a Class A or masonry chimney if an approved adapter is used.
This appliance is a direct vent heater. All combustion air must come directly from the outside of the building. The vent pipe for this unit consists of an inner and an outer pipe. The inner pipe carries the appliance exhaust out of the system, and the outer pipe brings fresh combustion air into the appliance.
• A round support box/wall thimble or heat shield is required when the venting passes through a combus­tible wall.
• A support box or ceiling fi restop is required when the venting passes through a ceiling.
• Roof fl ashing and a storm collar are required when venting passes through the roof.
• Follow instructions provided with the venting for instal­lation of these items.
B. Use of Elbows
CAUTION
ALL vent confi guration specifi cations MUST be followed.
• This product is tested and listed to these specifi cations.
• Appliance performance will suffer if specifi cations are not followed.
Diagonal runs have both vertical and horizontal vent as­pects when calculating the effects. Use the rise for the vertical aspect and the run for the horizontal aspect (see Figure 5.1).
Two 45º elbows may be used in place of one 90º elbow . On 45º runs, one foot of diagonal is equal to 8-1/2 (216 mm) inches horizontal run and 8-1/2 (216 mm) inches vertical run. A length of straight pipe is allowed between two 45º elbows (see Figure 5.1).
Vertical
12 in.
8-1/2 in.
WARNING
Fire Hazard. Explosion Risk. Asphyxiation Risk. Do NOT connect this gas appliance to a chimney
ue serving a separate solid-fuel or gas burning appliance.
• Vent this appliance directly outside.
• Use separate vent system for this appliance. May impair safe operation of this appliance or
other appliances connected to the fl ue.
8-1/2 in.
Horizontal
Figure 5.1
C. Measuring Standards
Vertical and horizontal measurements were made using the following standards.
1. Pipe measurements are from center line to center line.
2. Horizontal terminations are measured to the outside mounting surface (fl ange of termination cap) (see Figure 4.1) on page 9.
3. Vertical terminations are measured to the top of the last pipe before termination cap.
4. Horizontal pipe installed level with no rise.
Heat & Glo • Paloma • 7031-220 Rev. S • 8/09 11
D. How to Use the Vent Graph
1. Measure the distance from the top of appliance to the center of the 90° elbow. On the graph below, draw a horizontal line from that measurement on the vertical axis across until it intersects with the slanted line.
2. From the point of this intersection, draw a vertical line to the bottom of the graph.
3. The point at which this line meets the bottom line of the graph is the maximum length of the horizontal run.
Example 1: If the vertical dimension from the top of the appliance to the center of the 90° elbow is 7 ft. (2 m), the horizontal run to the outer wall fl ange must not exceed 13 ft. (4 m).
Example 2: If the vertical dimension from the top of the appliance is 21 ft. (6.4 m), the horizontal run to the outer wall fl ange must not exceed 9 ft. (3 m).
4. Each 90° elbow is equivalent to 3 ft. (914 mm) of vent pipe and each 45° elbow is equivalent to 1 ft. (305 mm) of vent pipe, and must be subtracted from vent pipe run. A single vertical to horizontal 90° elbow is already calculated into the allowable 15 ft. (5 m) run. Each additional 90° elbow reduces the maximum horizontal distance by 3 ft. (914 mm).
Example: The use of three elbows would reduce the allowable horizontal run to 9 ft. (3 - 1 = 2 elbows x 3 ft. = 6 ft.; 15 ft. max. - 6 ft. = 9 ft. max.)
E. Venting Guidelines
• The maximum horizontal vent run is 15 ft. (5 m) when the vertical vent rise is 10 ft. (3 m).
• The minimum horizontal vent run is 11-5/8 in. (295 mm).
• Horizontal sections require a 1/4 in. (6 mm) rise for every 12 in. (305 mm) of horizontal travel.
Horizontal sections require noncombustible support
• every 3 ft. (914 mm), e.g. wall strap.
• Wall thickness: Minimum 4 in. (102 mm). Maximum 20 in. (508 mm).
• Vent Diameter: Exterior 6-5/8 in. (168 mm); Inner 4 in. (102 mm).
EXCEPTION FOR REAR VENT KIT SNKD), HORIZONTAL INSTALLATION:
• The maximum horizontal vent run is 3 ft. (914 mm).
• The maximum horizontal vent run with a 45° elbow is 2 ft. (610 mm).
No external minimum rise is required. The minimum horizontal vent run is 11-5/8 in. (295 mm).
• For any vertical rise when rear venting, a minimum of 2 ft. (610 mm) vertical must be used prior to any horizontal run.
• Snorkel Kit (SLK-SNKD) must be used for horizontal vent runs with no vertical rise.
(Snorkel Kit SLK-
Figure 5.2
VERTICAL DISTANCE
FROM APPLIANCE
TO THE 90º ELBOW
6 ft. (2 m) Minimum
Vertical Termination
L
C
For rear vent or top of appliance for top vent.
EX. 2
EX. 1
35'
34' 32' 30' 28' 26' 24' 22' 20' 18' 16' 14' 12' 10'
8' 6' 4' 2' 0'
11-5/8”
(MIN)
C
L
TE REQUIRE
VENT RESTRIC
PLA
2' 4' 6' 8' 10' 12' 14' 15'
6 in. (152 mm) Minimum starter pipe
OR
T
D
(MAX)
3 ft. (914 mm) Maximum Horizontal run with no vertical pipe and with 1/4 in. (6 mm) rise per foot.
TOTAL HORIZONTAL RUN TO
OUTSIDE OF EXTERIOR WALL
(INCLUDING ELBOWS)
To adjust the vent restrictor
plate, see page 34.
Heat & Glo • Paloma • 7031-220 Rev. S • 8/0912
F. Horizontal Termination
90º ELBOW
PIPE LENGTH
WALL THIMBLE COVER
PIPE LENGTH
TERMINATION CAP
WALL THIMBLE
2. Direct vent pipe is designed with a locking connection. To connect the venting system to the appliance flue outlet, a twist-lock adapter is built into the appliance at the factory. Wall thickness may vary. Remember to include wall thickness in minimum clearances when figuring venting lengths for your installation needs.
3. Female ends of direct vent pipe/elbows are designed to slide straight onto the male ends of adjacent pipes by orienting the pipe indentations so they match and slide into the entry slots on the male ends, see Figure
5.4. Push the pipe sections completely together, then twist-lock one section clockwise approximately one­quarter turn, until the two sections are fully locked. The female locking lugs may not be visible from the outside. They may be located by examining the inside of the female ends.
FEMALE LOCKING LUGS
MALE LOCKING
CHOOSE BETWEEN
INTERIOR WALL
- 2 IN. (51 MM)
CLEARANCE FROM
REAR OF STOVE
CENTER LINE
SNORKEL CAP KIT (SLK-SNKD) MUST BE
USED FOR HORIZONTAL VENT RUNS
Figure 5.3
SLIM LINE
WALL THIMBLE
TRIM RING
WITH NO VERTICAL RISE.
STANDARD
OR
WALL THIMBLE
SNORKEL CAP
MINIMUM OF 6 IN. (152 MM) OF
PIPE THROUGH THE WALL
1. Determine the desired location of the appliance. Check to ensure that wall studs or roof rafters are not in the way when the venting system is being planned. If this is the case, you may want to adjust the location of the appliance.
WARNING
Fire Risk Exhaust Fumes Risk Impaired Performance of Appliance
• Ensure vent components are locked together correctly.
• Pipe may separate if not properly joined.
Figure 5.4
WARNING
Fire Risk. Explosion Risk. Combustion Fume Risk. Use vent run supports per installation
instructions. Connect vent sections per installation
instructions.
• Maintain all clearances to combustibles.
• Do NOT allow vent to sag below connection point to appliance.
• Maintain specifi ed slope (if required).
Improper support may allow vent to sag or separate.
4. For installations using a round support box/wall thimble (check pipe manufacturer's instructions), mark the wall for a 10 in. x 10 in. (254 mm x 254 mm) square hole. The center of the square hole should line up with the center line of the horizontal pipe, as shown in Figure
5.5. Cut and frame the hole in the exterior wall where the vent will be terminated. If the wall being penetrated is constructed of noncombustible material, i.e. masonry block or concrete, a 7 in. (178 mm) diameter hole is acceptable.
Heat & Glo • Paloma • 7031-220 Rev. S • 8/09 13
CENTER LINE
WOOD SCREW
CENTER OF HOLE
WALL THIMBLE
Figure 5.5
CENTER LINE
5. Installation requires a minimum of 6 in. (152 mm) horizontal run of vent with a 1/4 in. (6 mm) rise run towards the termination. Each 1 ft. (305 mm) of horizontal venting must include a 1/4 in. (6 mm) rise. Never allow the vent to run downward. This could cause high temperatures and may present the possibility of a fire. The location of the horizontal vent termination on an exterior wall must meet all local and national building codes, and must not be easily blocked or obstructed, see Figure 4.4 on page 10.
6. For installations requiring a vertical rise on the exterior of the building, the HHT RHVK snorkel kit (Part #844-
8921) is available with a 14 in. (356 mm) and a 36 in. (914 mm) tall snorkel termination cap. Follow the same installation procedures as used for standard horizontal terminations. If the snorkel termination must be installed below grade (i.e. basement application), proper drainage must be provided to prevent water from entering the snorkel termination. Do not backfill around snorkel termination.
7. Position the horizontal termination cap in the center of the 10 in. x 10 in. (254 mm x 254 mm) square hole and run a bead of non-hardening mastic around its outside edges, so as to make a seal between it and the wall, attach termination cap to the exterior wall with the four wood screws provided. The arrow on the vent cap should be pointing up (Figure 5.6).
Heat & Glo • Paloma • 7031-220 Rev. S • 8/0914
HOT
WALL THIMBLE
Figure 5.6
PART HHW2 #841-0670 (PREFERRED)
8. The four wood screws provided should be replaced with appropriate fasteners for stucco, brick, concrete, or other types of sidings.
9. Termination cap HHW2 (Part #841-0670) is highly recommended on a building with vinyl siding, as the vinyl siding standoff is built in. The pilot hole will be 2 in. (51 mm) closer to the bottom of the square than the top. Using a framing square, draw a 14 in. x 14 in. (356 mm x 356 mm) square around the pilot hole. See Figure 5.7.
8 in.
(203 mm)
7 in.
(178 mm)
Figure 5.7
7 in.
(178 mm)
6 in.
(152 mm)
10. If you are installing termination cap HHW2, the pipe will be off center on flashing). Ensure that proper clearances to combustible materials are maintained. If you are using an approved termination cap other than HHW2 (part #841-0670) on a building with vinyl siding, a vinyl siding standoff should be installed between the termination cap and the exterior wall (Figure 5.8, on the next page). Follow manufacturer’s instructions for attaching the vinyl siding standoff to the horizontal termination cap. The vinyl siding standoff prevents excessive heat from possibly melting the vinyl siding material. The vent terminal cap shall not be recessed into a wall or siding. Remove siding from the area where the standoff will be located.
VINYL SIDING
WARNING
APPLY SEALANT TO ALL FOUR SIDES
SCREWS
BOLT HORIZONTAL TOP TO VINYL STANDOFF
WALL THIMBLE COVER
WALL THIMBLE
Figure 5.8
SCREWS
VINYL SIDING STANDOFF WITH SIDING BENEATH REMOVED
11. Place the wall thimble cover over the pipe assembly and slide the appliance and vent assembly towards the wall, carefully inserting the vent pipe into the vent termination cap assembly . It is important that the vent pipe extend into the vent termination cap a sufficient distance so as to result in a minimum pipe overlap of 1-1/4 in. (32 mm). Secure the connection between the vent pipe and the vent termination cap by attaching the two sheet metal strips extending from the vent termination cap assembly into the outer wall of the vent pipe. Use the two sheet metal screws provided to connect the strips to the pipe section (Figure 5.9).
Fire Risk Exhaust Fumes Risk Impaired Performance of Appliance
• Ensure vent components are locked together correctly.
• Pipe may separate if not properly joined.
WARNING
Do NOT connect a pipe section to a termination cap without using the telescoping flue section found on the termination cap.
WARNING
Burn Risk
• Local codes may require installation of a cap shield to prevent anything or anyone from touching the hot cap.
1/4 in. (6 mm)
FOLD STRAP HERE
SHEET METAL SCREW
WALL
WALL THIMBLE COVER/CEILING FIRESTOP AS REQUIRED BY LOCAL JURISDICTION
Figure 5.9
STRAP
THIMBLE
Note: The attachment from the vent pipe to the vent termination cap must be sealed with silicone. Termination caps shall not be recessed into a wall or siding.
Heat & Glo • Paloma • 7031-220 Rev. S • 8/09 15
G. Vertical Termination
VERTICAL TERMINATION
CAP USE PART #SLK-991DA
STORM COLLAR
FLASHING
FIRESTOP
SUPPORT BOX
PIPE LENGTH
On vertical terminations use only Part #SLK-991DA or like components. See page 55.
Figure 5.10
1. Check the installation instructions for required 1 in.
(25 mm) clearances (air space) to combustibles when passing through ceilings, walls, roofs, enclosures, attic rafters, or other nearby combustible surfaces. See page 16, Figure 5.15. Check the instructions for maximum vertical rise of the venting system, and any maximum horizontal offset limitations. All offsets must fall within the set parameters of the vent graph (Figure
5.2) located on page 12.
Note: Maximum ver tical rise allowable is 40 f t. (10.7 m),
Figure 5.11 . Maximum number of 45º elbows permitted for a vertical installation is eight, provided their inst allation does not decrease maximum allowable horizontal run (as specifi ed by vent graph, on page 12).
40 ft. (12 m)
MAXIMUM
Figure 5.11
2. Set the gas appliance in its desired location. Drop
a plumb bob down from the ceiling to the position of the appliance flue exit, and mark the location where the vent will penetrate the ceiling. Drill a small hole at this point. Next, drop a plumb bob from the roof to the hole previously drilled in the ceiling, and mark the spot where the vent will penetrate the roof. Determine if ceiling joists, roof rafters, or other framing will obstruct the venting system. You may wish to relocate the appliance, or to offset, as shown in Figure 5.12 to avoid cutting load bearing members.
PLUMBER'S TAPE
CONNECTED TO
WALL STRAP
WALL
STRAP
WARNING
Fire Risk. Explosion Risk. Maintain vent clearance to combustibles as
specifi ed.
• Do not pack air space with insulation or other materials.
Failure to keep insulation or other materials away from vent pipe may cause fi re.
Heat & Glo • Paloma • 7031-220 Rev. S • 8/0916
Figure 5.12
TWO 45º
ELBOWS
3. To install the round support box/wall thimble cover in
L
a flat ceiling, cut a 10 in. (254 mm) square hole in the ceiling, centered on the hole drilled in Step 2. Frame the hole as shown in Figure 5.13.
CEILING JOISTS
FRAMING
ROUND CEILING SUPPORT BOX/WAL THIMBLE COVER
SHINGLES OVERLAP ON TOP EDGE OF FLASHING
Figure 5.14
CAP AND STORM COLLAR NOT SHOWN FOR CLARITY
1-1/2 in. (38 mm) LONG WOOD SCREWS
Figure 5.13
4. Assemble the desired lengths of pipe and elbows necessary to reach from the appliance up through the round support box. Ensure that all pipe and elbow connections are in their fully twist-locked position. Assemble as instructed.
5. Cut a hole in the roof centered on the small drill hole placed in the roof in Step 2. The hole should be of sufficient size to meet the minimum requirements for clearance to combustibles, as specified. Continue to assemble lengths of pipe and elbows necessary to reach from the ceiling support box/wall thimble up through the roof line. Galvanized pipe and elbows may be utilized in the attic, as well as above the roofline. The galvanized finish is desirable above the roofline, due to its higher corrosion resistance.
• If an offset is necessary in the attic to avoid
obstructions, it is important to support the vent pipe every 3 ft. (914 mm) to avoid excessive stress on the elbows, and possible separation. Wall straps are available for this purpose, Figure 5.12, page 16.
• Whenever possible, use 45° elbows, instead of 90°
elbows. The 45° elbow offers less restriction to the flow of flue gases and intake air.
6. Slip the flashing over the pipe section(s) protruding through the roof. Secure the base of the flashing to the roof with roofing nails. Ensure the roofing material overlaps the top edge of the flashing as shown in Figure 5.14. Verify that the chimney is the required height above the roof. See roof pitch table, Figure 4.3, on page 9.
7. Continue to assemble pipe sections until the height of the vent (before adding the termination cap) meets the minimum code requirements as outlined in the current CAN/CGA-B149 Installation Codes (in Canada), the National Fuel Gas Code NFPA 54/ANSI Z223.1 (in USA), or local codes. Note that for steep roof pitches, the vent height must be increased. See Roof Pitch Table (Figure 4.3, on page 9). In high wind conditions, nearby trees adjoining rooflines, steep pitched roofs, and other similar factors can result in poor draft, or down drafting. In these cases increasing the vent height or switching to the high wind termination cap may solve this problem.
8. Slip the storm collar over the pipe, and push it down to the top of the flashing (Figure 5.15). Use non­hardening sealant above and below the joint between the storm collar and the pipe.
OPTIONAL HIGH WIND TERMINATION CAP
SECURE FLASHING WITH
NON-HARDENING SEALANT AND
ROOFING NAILS
Figure 5.15
Heat & Glo • Paloma • 7031-220 Rev. S • 8/09 17
9. Twist-lock the vent cap and seal.
Note: For multi-story vertical installations, a ceiling firestop is required at the second floor, and any subsequent floors (Figure 5.16). The opening should be framed to 10 in. x 10 in. (254 mm x 254 mm) inside dimensions, in the same manner as shown in Figure 5.13.
NAILS
CEILING FIRESTOP
MINIMUM 1 in.(25 mm)
CLEARANCE
MINIMUM 1 in.(25 mm)
CLEARANCE
Figure 5.16
MINIMUM 1 in. (25 mm)
CLEARANCE
MINIMUM 1 in.(25 mm)
CLEARANCE
WARNING
Fire Risk. Explosion Risk.
• Any occupied areas above the first floor, including closets and storage spaces, which the vertical vent passed through must be enclosed. The enclosure may be framed and sheetrocked with standard construction materials; however, refer to these installation instructions for the minimum allowable clearance between the outside of the vent pipe and the combustible surfaces of the enclosure. Do not fill any of the required air space with insulation.
Heat & Glo • Paloma • 7031-220 Rev. S • 8/0918
H. Cathedral Ceiling
1. Follow installation Steps 1 and 2 under vertical instal­lation section, page 16.
2. Remove shingles or other roof covering as necessary to cut the rectangular hole for the support box. Cut the hole 1/8 in. (3 mm) larger than the support box outline.
3. Lower the support box through the hole in the roof until the bottom of the support box protrudes at least 2 in. (51 mm) below the ceiling (Figure 5.17). Align the support box both vertically and horizontally with a level. Temporarily tack the support box in place through the inside walls and into the roof sheathing.
Figure 5.18
LEVEL
CATHEDRAL CEILING SUPPORT BOX
2 in. (51 mm) MIN. BELOW FINISHED CEILING
CUT HOLE 1/8 in. (3 mm) GREATER IN SIZE THAN PATTERN OF SUPPORT BOX AS IT IS PROJECTED ONTO ROOF LINE
Figure 5.17
4. Using tin snips, cut the support box from the top corners
down to the roofline, and fold the resulting flaps over the roof sheathing (Figure 5.18). Before nailing it to the roof, run a bead of non-hardening mastic around the top edges of the support box to make a seal between it and the roof. Clean out any combustible material from inside the support box.
5. Assemble the desired lengths of pipe and elbows necessary to reach from the appliance up through the round support box. Ensure that all pipe and elbow connections are in their fully twist-locked position. Assemble as instructed.
6. Place the support clamp (provided with the support box) inside the support box (at the bottom), and secure to the pipe section. The clamp allows the support box to support the weight of the pipe sections. Continue to add pipe sections until you are above the roofline.
7. Complete the cathedral ceiling installation by following the same procedures outlined in steps 7 through 9 for vertical installations, pages 17-18.
8. Install the black trim collar around the outside of the cathedral ceiling support box (Figure 5.19). The two pieces of the trim collar slide over one another to allow for easy adjustment around the support box. Using the six screws provided, secure the four corners and the overlapping sections of the trim collar to the ceiling. You may want to predrill the holes for the overlapped sections for ease of installation.
TRIM COLLAR
CATHEDRAL CEILING SUPPORT BOX
SCREWS
Figure 5.19
Heat & Glo • Paloma • 7031-220 Rev. S • 8/09 19
Loading...
+ 43 hidden pages