WARNING: IF THE INFORMATION
IN THESE INSTRUCTIONS IS NOT
FOLLOWED EXACTL Y, A FIRE OR
EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance.
- What to do if you smell gas
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call
the fire department.
- Installation and service must be performed by a
qualified installer, service agency, or the gas
supplier.
Installers Guide
Underwriters
Laboratories Listed
READ THIS MANUAL BEFORE INSTALLING OR
OPERATING THIS APPLIANCE. THIS INSTALLERSGUIDE MUST BE LEFT WITH APPLIANCE FOR
FUTURE REFERENCE.
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION,
SERVICE OR MAINTENANCE CAN
CAUSE INJUR Y OR PROPERTY DAMAGE. REFER TO THIS MANUAL. FOR
ASSISTANCE OR ADDITIONAL INFORMA TION CONSULT A QUALIFIED INSTALLER, SERVICE AGENCY, OR THE
GAS SUPPLIER.
1.This appliance may be installed in an aftermarket, permanently located, manufactured (mobile) home, where not prohibited
by local codes.
2.This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certified kit is used.
Printed in U.S.A. Copyright 2004,
Heat-N-Glo, a brand of Hearth & Home Technologies Inc.
20802 Kensington Boulevard, Lakeville, MN 55044
This product is covered by one or more of the following patents: (United States) 4,112,913; 4,408,594; 4,422,426; 4,424,792; 4,520,791; 4,793,322;
4,852,548; 4,875,464; 5,000,162; 5,016,609; 5,076,254 5,191,877; 5,218,953; 5,328,356; 5,429,495; 5,452,708; 5,542,407; 5,613,487; (Australia)
543790; 586383; (Canada) 1,123,296; 1,297,746; 2,195,264; (Mexico) 97-0457; (New Zealand) 200265; or other U.S. and foreign patents pending.
Please contact your Heat-N-Glo dealer for any questions
or concerns. For the number of your nearest Heat-NGlo dealer, please call 1-888-427-3973.
1
380-900O 1/04
SAFETY AND WARNING INFORMATION
READ and UNDERSTAND all instructions carefully
!
before starting the installation. FAILURE TO
FOLLOW these installation instructions may result
in a possible fire hazard and will void the warranty.
Prior to the first firing of the fireplace, READ the
!
Using Your Fireplace section of the Owners Guide.
DO NOT USE this appliance if any part has been
under water. Immediately CALL a qualified service
!
technician to inspect the unit and to replace any part
of the control system and any gas control which has
been under water.
THIS UNIT IS NOT FOR USE WITH SOLID FUEL.
!
Installation and repair should be PERFORMED by a
qualified service person. The appliance and venting
!
system should be INSPECTED before initial use
and at least annually by a professional service
person. More frequent cleaning may be required
due to excessive lint from carpeting, bedding
material, etc. It is IMPERATIVE that the unit’s
control compartment, burners, and circulating air
passageways BE KEPT CLEAN to provide for
adequate combustion and ventilation air.
These units MUST use one of the vent systems
described in the Installing the Fireplace section of
!
the Installers Guide. NO OTHER vent systems or
components MAY BE USED.
This gas fireplace and vent assembly MUST be
!
vented directly to the outside and MUST NEVER be
attached to a chimney serving a separate solid fuel
burning appliance. Each gas appliance MUST USE
a separate vent system. Common vent systems are
PROHIBITED.
INSPECT the external vent cap on a regular basis to
!
make sure that no debris is interfering with the air
flow.
The glass door assembly MUST be in place and
!
sealed, and the trim door assembly MUST be in
place on the fireplace before the unit can be placed
into safe operation.
DO NOT OPERA TE this appliance with the glass
!
door removed, cracked, or broken. Replacement of
the glass door should be performed by a licensed
or qualified service person. DO NOT strike or slam
the glass door.
Always KEEP the appliance clear and free from
!
combustible materials, gasoline, and other
flammable vapors and liquids.
NEVER OBSTRUCT the flow of combustion and
!
ventilation air. Keep the front of the appliance
CLEAR of all obstacles and materials for servicing
and proper operations.
Due to the high temperature, the appliance should
be LOCATED out of traffic areas and away from
!
furniture and draperies. Clothing or flammable
material SHOULD NOT BE PLACED on or near the
appliance.
Children and adults should be ALERTED to the
!
hazards of high surface temperature and should
ST AY AWAY to avoid burns or clothing ignition.
Young children should be CAREFULL Y SUPERVISED
when they are in the same room as the appliance.
The glass door assembly SHALL ONLY be
!
replaced as a complete unit, as supplied by the gas
fireplace manufacturer. NO SUBSTITUTE material
may be used.
DO NOT USE abrasive cleaners on the glass door
!
assembly. DO NOT ATTEMPT to clean the glass
door when it is hot.
Turn off the gas before servicing this appliance. It is
recommended that a qualified service technician
!
perform an appliance check-up at the beginning of
each heating season.
Any safety screen or guard removed for servicing
!
must be replaced before operating this appliance.
DO NOT place furniture or any other combustible
!
household objects within 36 inches of the fireplace
front.
2
TABLE OF CONTENTS
Safety and Warning Information ................................................. 2
u
Service Parts Lists ...................................................................... 4
Section 1: Approvals and Codes................................................ 8
Step 11Before Lighting the Fireplace........................................ 34
Step 12Lighting the Fireplace.................................................... 34
After the Installation ...................................................................... 34
Section 4: Maintaining and Servicing Your Fireplace ......... 35
u = Contains updated information.
3
Service Parts
8000TRD, 8000TRD-IPI
8
19
(NG, LP) Exploded Parts Diagram
(GN, PL) Vue éclatée des pièces
6
8000TRD Beginning Manufacturing Date: 6-01
8000TRD-IPI Beginning Manufacturing Date: 8-01
Ending Manufacturing Date: ________________
4
3
Part number list on following page.
*
La liste des numéros de pièce se
*
trouve à la page suivante.
18
9 Log Set Assembly
17
12
13
10
5
16
2
7
14
1
11
15
4
Service Parts List / Liste des pièces de rechange
8000TRD, 8000TRD-IPI
IMPORTANT: THIS IS DATED INFORMA TION. The most current information is located on your dealers VIP site. When ordering,
supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure
n'est valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents.
Lors d'une commande, veuillez fournir les numéros de série et de modèles pour un remplacement adéquat des pièces.
ITEM /
PIÈCE
COMMON PARTS / PIÉCES COMMUNES
SERIAL # /
N° DE SÉRIE
PART NUMBER
/ N° DE PIÈCE
Burner Orifice NG (#31) / Orifice de brûleur GN (#31)582-831
Burner Orifice LP (1.8mm) / Orifice de brûleur PL (1.8mm)582-818
2Burner NG / Brûleur GN380-378A-UM
2Burner LP / Brûleur PL2028-009
3Glass Door Assembly / Porte en verreGLA-8TRD
4Log Grate / Grille de Bûche582-360A
5Refractory Base / Réfractaire BaseSRV582-370-UM
6Refractory Left Base / RéfractaireSRV582-376-UM
7Refractory Right Base / RéfractaireSRV582-377-UM
8Hood / HotteSRV560-175
9Log Set Assembly / Jeu de BûchesLOGS-8TRC
8Gasket Orifice / Orifice de Joint438-407
9Valve Bracket / Parenthèse de Valve
10Flex Ball Valve Assembly / Fléchir l'Assemblée de Soupape de Balle302-320A
11Valve Plate Gasket / Joint de Plat de Valve385-402
12Ground Strap / Courroie de Raison(Terre)2025-512
Transformer / Transformateur593-593A
Battery Pack / Paquet de Batterie(Pile)593-594A
DESCRIPTION
SERIAL #
/ N° DE SÉRIE
PRE 22099930
POST 22099930
PRE 002324001
POST 002324001
PRE 002324001
POST 002324001
PRE 002324001
POST 002324001
PART NUMBER
/ N° DE PIÈCE
477-301A
383-302A
385-510A
4021-025
385-511A
4021-026
385-169
2025-101
u
6
Service Parts
8000TRD
Standing Pilot Ignition
Valve Assembly
8
9
(NG, LP) Exploded Parts Diagram
(GN, PL) Vue éclatée des pièces
10
Beginning Manufacturing Date: 6-03
Ending Manufacturing Date: ______
7
6
5
4
14
2
3
1
ITEM /
PIÈCE
1ON/OFF Rocker Switch / Interrupteur à bascule MARCHE/ARRÊT060-521A
2Valve NG / Valve GN060-522
2Valve LP / Valve PL060-523
3Flexible Gas Connector / Tuyau à gaz flexible
4Valve Plate Gasket / Joint de Plat de Valve385-402
5Burner Neck Gasket / Joint de Cou de Brûleur438-407
6Pilot Bracket / Parenthèse Pilote530-164
7Pilot Assembly NG / Module de veilleuse GN485-510A
7Pilot Assembly LP / Module de veilleuse PL485-511A
8Flex Ball Valve Assembly / Fléchir l'Assemblée de Soupape de Balle302-320A
9Wire Assembly / Module de fil049-552A
10Piezo Ignitor / Allumeur piézo291-513
11Pilot Control Knob / Piloter le Bouton de Contrôle571-530
12Flame Control Knob / Flamber le Bouton de Contrôle571-531
13Control Panel / Tableau de commande avant385-154
14Valve Bracket / Parenthèse de Valve550-169
11
12
DESCRIPTION
13
SERIAL #
/ N° DE SÉRIE
PRE 22099930
POST 22099930
PART NUMBER
477-301A
383-302A
/ N° DE PIÈCE
7
1
Approvals and
Codes
Appliance Certification
The Heat-N-Glo fireplace models discussed in this Installers
Guide have been tested to certification standards and listed
by the applicable laboratories.
Certification
MODEL: 8000TRD
LABORATORY: Underwriters Laboratories
TYPE: Direct Vent Gas Fireplace
STANDARD:
ANSI Z21.50b-2000•CSA2.22b-2000•UL307B
Installation Codes
The fireplace installation must conform to local codes. Before
installing the fireplace, consult the local building code
agency to ensure that you are in compliance with all
applicable codes, including permits and inspections.
In the absence of local codes, the fireplace installation must
conform to the National Fuel Gas Code ANSI Z223.1 (in
the United States) or the CAN/CGA-B149 Installation Codes
(in Canada). The appliance must be electrically grounded
in accordance with local codes or, in the absence of local
codes with the National Electric Code ANSI/NFPA No. 70
(in the United States), or to the CSA C22.1 Canadian Electric
Code (in Canada).
High Altitude Installations
U.L. Listed gas appliances are tested and approved without requiring changes for elevations from 0 to 2,000 feet in
the U. S. A. and in Canada.
When installing this appliance at an elevation above 2,000
feet, it may be necessary to decrease the input rating by
changing the existing burner orifice to a smaller size. Input
rate should be reduced by 4% for each 1000 feet above a
2000 foot elevation in the U.S.A. or 10% for elevations
between 2000 and 4500 feet in Canada. If the heating value
of the gas has been reduced, these rules do not apply. To
identify the proper orifice size, check with the local gas
utility.
If installing this appliance at an elevation above 4,500 feet
(in Canada), check with local authorities.
These models may be installed in a bedroom or bed-sitting
room in the U.S.A. and Canada.
Heat-N-Glo Quality
Systems registered
by SGS ICS
8
2
Getting Started
Introducing the Heat-N-Glo Gas Fireplaces
Heat-N-Glo direct vent gas fireplaces are designed to operate with all combustion air siphoned from outside of the
building and all exhaust gases expelled to the outside.
The information contained in this Installers Guide, unless
noted otherwise, applies to all models and gas control
systems. Gas fireplace diagrams, including the dimensions,
are shown in this section.
Pre-install Preparation
This gas fireplace and its components are tested and safe
when installed in accordance with this Installers Guide.
Report to your dealer any parts damaged in shipment,
particularly the condition of the glass. Do not install any
unit with damaged, incomplete, or substitute parts.
The vent system components are shipped in separate
packages. The gas logs may be packaged separately and
must be field installed.
Read all of the instructions before starting the
installation. Follow these instructions carefully during
the installation to ensure maximum safety and benefit.
Failure to follow these instructions will void the
owner’s warranty and may present a fire hazard.
The Heat-N-Glo Warranty will be voided by, and Heat-N-Glo
disclaims any responsibility for, the following actions:
• Installation of any damaged fireplace or vent system
component.
• Modification of the fireplace or direct vent system.
• Installation other than as instructed by Heat-N-Glo.
• Improper positioning of the gas logs or the glass door.
• Installation and/or use of any component part not manufactured and approved by Heat-N-Glo, not withstanding
any independent testing laboratory or other party approval
of such component part or accessory.
ANY SUCH ACTION MAY POSSIBLY CAUSE A FIRE
HAZARD.
When planning a fireplace installation, it’s necessary to
determine:
• Where the unit is to be installed.
• The vent system configuration to be used.
• Gas supply piping.
• Electrical wiring.
• Framing and finishing details.
• Whether optional accessories—devices such as a fan,
wall switch, or remote control—are desired.
If the fireplace is to be installed on carpeting or tile, or on
any combustible material other than wood flooring, the
fireplace should be installed on a metal or wood panel that
extends the full width and depth of the fireplace.
9
8 3/8
(212mm)
3 1/2
(89mm)
29 1/8
(740mm)
Ø8(203mm)
ELECTRICAL
17 3/4 (450mm)
35 1/2 (902mm)
GAS LINE
ACCESS
Ø8 (203mm)
2 1/4
(56mm)
9 1/8
(233mm)
40 3/8
(1026mm)
21 1/2 (548mm)
11 3/4 (297mm)
ACCESS
36 3/4
(932mm)
26 7/8
(681mm)
43 (1091mm)
48 3/8 (1229mm)
TOP STANDOFFS
GAS CONTROLS
GAS LINE ACCESS
Figure 1. Diagram of the 8000TRD
TOP VENT
COLLARS
HOOD
RATING PLATE
AND LABELS
ELECTRICAL
ACCESS
10
1/2” MIN. (13mm)
1” MIN. (25mm)
B
Installing the Fireplace
3
Constructing the Fireplace Chase
A chase is a vertical box-like structure built to enclose the
gas fireplace and/or its vent system. Vertical vents that run
on the outside of a building may be, but are not required to
be, installed inside a chase.
CAUTION: TREATMENT OF FIRESTOP SPACERS AND
CONSTRUCTION OF THE CHASE MAY VARY WITH THE
TYPE OF BUILDING. THESE INSTRUCTIONS ARE NOT
SUBSTITUTES FOR THE REQUIREMENTS OF LOCAL
BUILDING CODES. THEREFORE, YOUR LOCAL BUILDING CODES MUST BE CHECKED TO DETERMINE THE
REQUIREMENTS FOR THESE STEPS.
Factory-built fireplace chases should be constructed in the
manner of all outside walls of the home to prevent cold air
drafting problems. The chase should not break the outside
building envelope in any manner.
This means that the walls, ceiling, base plate and cantilever
floor of the chase should be insulated. Vapor and air infiltration barriers should be installed in the chase as per regional
codes for the rest of the home. Additionally, Heat-N-Glo recommends that the inside surfaces be sheetrocked and taped
for maximum air tightness.
To further prevent drafts, the firestops should be caulked to
seal gaps. Gas line holes and other openings should be
caulked or stuffed with insulation. If the unit is being installed on a cement slab, we recommend that a layer of
plywood be placed underneath to prevent conducting cold
up into the room.
THE CHASE SHOULD BE CONSTRUCTED SO THA T ALL
CLEARANCES TO THE FIREPLACE ARE MAINTAINED
AS SPECIFIED WITHIN THIS INSTALLERS GUIDE.
A
E
C
VENTINGABCDE
Top49"22"39-1/2"56"79"
Rear49"22"43-1/2"62"87"
*
*NOTE: If venting with (2) 900 elbows off rear of unit
the dimensions C, D, and E, will change.
Figure 2. Fireplace Dimensions, Locations,
and Space Requirements
Minimum Clearances
from the Fireplace to Combustible Materials
Inchesmm
Glass Front ...................... 36....................914
* See Figure 3.
**The clearance to the ceiling is measured from the top
of the unit, excluding the standoffs (see Figure 38).
The distance from the unit to combustible con-
struction is to be measured from the unit outer
wrap surface to the combustible construction, NOT
from the screw heads that secure the unit together.
D
Step 1. Locating the Fireplace
The following diagram shows space and clearance requirements for locating a fireplace within a room.
Clearance Requirements
The top, back, and sides of the fireplace are defined by
stand-offs. The minimum clearance to a perpendicular wall
extending past the face of the fireplace is one inch (25 mm).
The back of the fireplace may be recessed 21 1/2 inches
(546 mm) into combustible construction.