3. Integrated blower/burner control board with built-in diagnostic capability permits on-site trouble shooting.
4. One-piece top over the indoor section with drip lip, drawn painted base pan, and 1" raised
flanges for supply/return air connections provides superior water management.
5. Convertible horizontal and vertical airflow design allows maximum field flexibility and minimizes inventory
requirements.
6. Standard full perimeter forkable 14 gauge baserail with lifting holes for easier maneuvering and installations.
7. Factory installed one-inch throw away filter with provisions for two-inch filter.
8. Direct drive blowers to accommodate a wide range of design conditions.
9. Easily removable filter, blower, gas heat, and compressor/control access panels permits prompt service.
10. Number and color coded wiring helps facilitate service and maintenance.
11. Common cabinet and components allows for installation flexibility and fewer parts to inventory.
12. Standard freezestat control offers evaporator coil freeze protection.
13. Optional field installed high and low pressure controls.
14. Externally mounted refrigerant gauge ports for easy service diagnostics.
15. Side and base electric power and gas connection entry helps minimize roof penetrations.
16. Quick assembly common roof curbs helps save field labor and maximize size flexibility.
17. Easy to install, plug-in, slip-in, 100% fully modulating economizers.
18. Quality powder paint finish offers long lasting protection against extreme weather conditions and is able to
withstand 1000 HR salt spray test.
These quality features are included in the
5
Heat Controller, Inc.
-5-
Heat Controller Package Gas Electric Unit
Evaporator Coil/Filter Access
• Return air filters, normally
provided, are removed in
this photo.
• Corrosion resistant
plastic condensate pan
INTRODUCTION
Tubular Heat Exchanger
• Aluminized steel
(viewed from supply
air side panel.)
• Stainless steel available
Control Box Access
Compressor Access
Blower Access
• Belt drive model shown.
(On 460 volt 3-phase 5 ton model only.)
Heating Compartment Access
SELECTION PROCEDURE EXAMPLE
6
Heat Controller, Inc.
-6-
1. Determine cooling and heating requirements at design conditions.
Example:
Total cooling capacity ........................43,600 BTUH
Since total cooling is within the range of 4 ton unit and
requires 13 SEER efficiency level, enter cooling performance from the
TGC048C at 95°F outdoor temperature, 63°F wbt
entering indoor air, and 1550 CFM:
Total capacity ....................................47,300 BTUH
Power input ........................................3.5 kW
And also, at 76°F db indoor entering air, and using the formula
at the bottom of the table:
In the general data tables, note that the heating capacity of the 4 ton
model with the 135,000 input heater can deliver 106,500
BTUH, which is suitable for this application.
4. Determine blower speed and power to meet the system
requirements.
At the given external static pressure of 0.6 in wg, the belt model must
be selected. Enter the belt drive blower performance data at 1580
CFM and 0.6 in wg ESP:
Watts........635
5. Calculate indoor blower BTUH heat effect.
BTUH = Watts x 3.413 = 2168
6. Calculate net cooling capacities.
Net total cooling = 47,300 – 2168 = 45,132 BTUH
Net sensible cooling = 41,708 – 2168 = 39,540 BTUH
Nominal CFM/ARI Rated CFM 1200/12001200/12001200/1200
ARI Net Cooling Capacity Btuh 360003600036000
Net Sensible Capacity Btuh 264002640026400
Net Latent Capacity Btuh960096009600
Net System Power kW 3.083.083.08
2
1
Heating Performance (Package Gas/Electric)
Heating Input Btuh 120000120000120000
Heating Output Btuh945009720097200
Temperature Rise ºF50-8050-8050-80
AFUE (%)808080
Steady State Efficiency (%)818181
Qty of Burners666
Qty of Stages111
Gas Connection Pipe Size, in. .5.5.5
Compressor
Qty/Type
Outdoor Sound Rating (dB) 787878Outdoor Coil—Fin Type
Tube Type RifledRifledRifled
Tube Size in. OD 0.3750.3750.375
Face Area sq. ft. 16.9116.9116.91
Rows / Fins per inch 1/221/221/22
Indoor Coil—Fin Type
Tube Type RifledRifledRifled
Tube Size in.0.3750.3750.375
Face Area sq. ft.5.175.175.17
Rows / Fins per inch 2/172/172/17
Refrigerant Control TXVTXVTXV
Drain Connection Qty/Size, in. 1/0.751/0.751/0.75
Outdoor Fan—Type
Qty Used/Diameter in. 1/241/241/24
Drive Type/Speeds Direct/1Direct/1Direct/1
CFM 368036803680
Qty Motors-HP 1-1/31-1/31-1/3
Motor RPM107510751075
Indoor Fan—Type
Qty Used/Diameter in. 1/10x101/10x101/10x10
Drive Type/Speeds Direct/3Direct/3Direct/3
Motor Qty 111
Motor HP 1/21/21/2
Motor RPM 107510751075
Motor Frame Size 484848
Filter—Type
Furnished YesYesYes
(Qty) Size Recommended in. (2)16x25x1(2)16x25x1(2)16x25x1
Refrigerant Charge Oz. 939393Weights
Net Weight lbs. 543543543
Ship Weight lbs. 550550550
Notes:
1. Cooling performance is rated at 95ºF ambient, 80ºF/67ºF entering dry bulb/wet bulb temperatures. Gross capacity does not include the effect of fan
motor heat. ARI capacity is net and includes the effect of fan motor heat. Units are suitable for operation to plus or minus 20% of nominal cfm. Units
are certified and rated per ARI Standard 210/240.
2. EER/SEER are rated ARI condition and accordance with DOE test procedures.
3. Heating performance limit settings and rating data were established and approved under laboratory test conditions using American National
Standard Institute standards. Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet, rating should be resuced 4% for each
1000 feet above sea level.
Nominal CFM/ARI Rated CFM 1400/14501400/14501400/1450
ARI Net Cooling Capacity Btuh 410004100041000
Net Sensible Capacity Btuh 300003000030000
Net Latent Capacity Btuh110001100011000
Net System Power kW 3.593.593.59
2
1
Heating Performance (Package Gas/Electric)
Heating Input Btuh 120000120000120000
Heating Output Btuh945009720097200
Temperature Rise ºF50-8050-8050-80
AFUE (%)808080
Steady State Efficiency (%)818181
Qty of Burners666
Qty of Stages111
Gas Connection Pipe Size, in. .5.5.5
Compressor
Qty/Type
Outdoor Sound Rating (dB) 787878Outdoor Coil—Fin Type
Tube Type RifledRifledRifled
Tube Size in. OD 0.3750.3750.375
Face Area sq. ft. 16.9116.9116.91
Rows / Fins per inch 1.53/221.53/221.53/22
Indoor Coil—Fin Type
Tube Type RifledRifledRifled
Tube Size in.0.3750.3750.375
Face Area sq. ft.5.175.175.17
Rows / Fins per inch 3/133/133/13
Refrigerant Control TXVTXVTXV
Drain Connection Qty/Size, in. 1/0.751/0.751/0.75
Outdoor Fan—Type
Qty Used/Diameter in. 1/241/241/24
Drive Type/Speeds Direct/1Direct/1Direct/1
CFM 368036803680
Qty Motors-HP 1-1/31-1/31-1/3
Motor RPM107510751075
Indoor Fan—Type
Qty Used/Diameter in. 1/10x101/10x101/10x10
Drive Type/Speeds Direct/3Direct/3Direct/3
Motor Qty 111
Motor HP 1/21/21/2
Motor RPM 172517251725
Motor Frame Size 484848
Filter—Type
Furnished YesYesYes
(Qty) Size Recommended in. (2)16x25x1(2)16x25x1(2)16x25x1
Refrigerant Charge Oz. 117117117Weights
Net Weight lbs. 579579579
Ship Weight lbs. 586586586
Notes:
1. Cooling performance is rated at 95ºF ambient, 80ºF/67ºF entering dry bulb/wet bulb temperatures. Gross capacity does not include the effect of fan
motor heat. ARI capacity is net and includes the effect of fan motor heat. Units are suitable for operation to plus or minus 20% of nominal cfm. Units
are certified and rated per ARI Standard 210/240.
2. EER/SEER are rated ARI condition and accordance with DOE test procedures.
3. Heating performance limit settings and rating data were established and approved under laboratory test conditions using American National
Standard Institute standards. Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet, rating should be resuced 4% for each
1000 feet above sea level.
Nominal CFM/ARI Rated CFM 1600/15501600/15501600/1550
ARI Net Cooling Capacity Btuh 470004700047000
Net Sensible Capacity Btuh 336003360033600
Net Latent Capacity Btuh134001340013400
Net System Power kW 4.154.154.15
2
1
Heating Performance (Package Gas/Electric)
Heating Input Btuh 135000135000135000
Heating Output Btuh106500109400109400
Temperature Rise ºF50-8050-8050-80
AFUE (%)808080
Steady State Efficiency (%)818181
Qty of Burners666
Qty of Stages111
Gas Connection Pipe Size, in. .5.5.5
Compressor
Qty/Type
Outdoor Sound Rating (dB) 787878Outdoor Coil—Fin Type
Tube Type RifledRifledRifled
Tube Size in. OD 0.3750.3750.375
Face Area sq. ft. 16.5616.5616.56
Rows / Fins per inch 2/222/222/22
Indoor Coil—Fin Type
Tube Type RifledRifledRifled
Tube Size in.0.3750.3750.375
Face Area sq. ft.5.175.175.17
Rows / Fins per inch 3/153/153/15
Refrigerant Control TXVTXVTXV
Drain Connection Qty/Size, in. 1/0.751/0.751/0.75
Outdoor Fan—Type
Qty Used/Diameter in. 1/241/241/24
Drive Type/Speeds Direct/1Direct/1Direct/1
CFM 368036803680
Qty Motors-HP 1-1/31-1/31-1/3
Motor RPM107510751075
Indoor Fan—Type
Qty Used/Diameter in. 1/10x101/10x101/10x10
Drive Type/Speeds Direct/3Direct/3Direct/3
Motor Qty 111
Motor HP 1/21/21/2
Motor RPM 107510751075
Motor Frame Size 484848
Filter—Type
Furnished YesYesYes
(Qty) Size Recommended in. (2)16x25x1(2)16x25x1(2)16x25x1
Refrigerant Charge Oz. 167167167Weights
Net Weight lbs. 585585585
Ship Weight lbs. 592592592
Notes:
1. Cooling performance is rated at 95ºF ambient, 80ºF/67ºF entering dry bulb/wet bulb temperatures. Gross capacity does not include the effect of fan
motor heat. ARI capacity is net and includes the effect of fan motor heat. Units are suitable for operation to plus or minus 20% of nominal cfm. Units
are certified and rated per ARI Standard 210/240.
2. EER/SEER are rated ARI condition and accordance with DOE test procedures.
3. Heating performance limit settings and rating data were established and approved under laboratory test conditions using American National
Standard Institute standards. Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet, rating should be resuced 4% for each
1000 feet above sea level.
Nominal CFM/ARI Rated CFM 2000/19002000/19002000/1900
ARI Net Cooling Capacity Btuh 580005800058000
Net Sensible Capacity Btuh 420004200042000
Net Latent Capacity Btuh160001600016000
Net System Power kW 555
2
1
Heating Performance (Package Gas/Electric)
Heating Input Btuh 135000135000135000
Heating Output Btuh106500109400109400
Temperature Rise ºF40-7040-7040-70
AFUE (%)808080
Steady State Efficiency (%)818181
Qty of Burners666
Qty of Stages111
Gas Connection Pipe Size, in. .5.5.5
Compressor
Qty/Type
Outdoor Sound Rating (dB) 837878Outdoor Coil—Fin Type
Tube Type RifledRifledRifled
Tube Size in. OD 0.3750.3750.375
Face Area sq. ft. 16.5616.5616.56
Rows / Fins per inch 2/222/222/22
Indoor Coil—Fin Type
Tube Type RifledRifledRifled
Tube Size in.0.3750.3750.375
Face Area sq. ft.5.175.175.17
Rows / Fins per inch 3/153/153/15
Refrigerant Control TXVTXVTXV
Drain Connection Qty/Size, in. 1/0.751/0.751/0.75
Outdoor Fan—Type
Qty Used/Diameter in. 1/241/241/24
Drive Type/Speeds Direct/1Direct/1Direct/1
CFM 393039303930
Qty Motors-HP 1-1/31-1/31-1/3
Motor RPM107510751075
Indoor Fan—Type
Qty Used/Diameter in. 1/10x101/10x101/10x10
Drive Type/Speeds Direct/3Direct/3Belt/Variable
Motor Qty 111
Motor HP 113/4
Motor RPM 107510751725
Motor Frame Size 484856
Filter—Type
Furnished YesYesYes
(Qty) Size Recommended in. (2)16x25x1(2)16x25x1(2)16x25x1
Refrigerant Charge Oz. 160160160Weights
Net Weight lbs. 597597597
Ship Weight lbs. 604604604
Notes:
1. Cooling performance is rated at 95ºF ambient, 80ºF/67ºF entering dry bulb/wet bulb temperatures. Gross capacity does not include the effect of fan
motor heat. ARI capacity is net and includes the effect of fan motor heat. Units are suitable for operation to plus or minus 20% of nominal cfm. Units
are certified and rated per ARI Standard 210/240.
2. EER/SEER are rated ARI condition and accordance with DOE test procedures.
3. Heating performance limit settings and rating data were established and approved under laboratory test conditions using American National
Standard Institute standards. Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet, rating should be resuced 4% for each
1000 feet above sea level.
TGC060C-1K-135TGC060C-3K-135TGC060C-4K-135
11.6/1311.6/1311.6/13
3
1/Copeland Scroll
Louvered
Corrugated
Propeller
Forward Curved Centrifugal
Disposable
DR —Depression ratio
dbE —Entering air dry bulb
wbE—Entering air wet bulb
Total —Total capacity x 1000 BTUH
Sens —Sensible capacity x 1000 BTUH
Power—KW input
NOTES: ➀ When the entering air dry bulb is other than 80°F [27°C], adjust the sensible
capacity from the table by adding [1.10 x CFM x (1 – DR) x (dbE – 80)].
The following minimum clearances are recommended
for proper unit performance and serviceability.
UNIT DIMENSIONS
20
Heat Controller, Inc.
-20-
3-5 Ton [10.6-17.6 kW]
Accessory
Economizer with Single Enthalapy70 [32]
Power Exhaust19 [9]
Fresh Air Damper (Manual)11 [5]9 [4]
Fresh Air Damper (Motorized)13 [6]
Roof Curb 14"92 [42]88 [40]
Roof Curb 24"108 [49]104 [47]
Concentric Diffuser 18" Flush37 [17]26 [12]
Concentric Diffuser 20" Flush54 [24]42 [19]
Side Discharge Concentric Diffuser RXRN-FA6035 [16]20 [9]
Side Discharge Concentric Diffuser RXRN-FA6555 [25]40 [18]
Recommended
Clearance in. [mm]
48 [1219]A - Front
18 [457]B - Condenser Coil
12 [305]C - Duct Side
36 [914]D - Evaporator End
60 [1524]E - Above
*Without Economizer. 57" [1448 mm] With Economizer
Location
NOTE: Supply duct may be installed
with “0” inch clearance to combustible
materials, provided 1"
minimum Fiberglass insulation is
applied either inside or on the outside
of the duct.
ShippingOperating
lbs [kg]lbs [kg]
60 [27]
16 [7]
11 [5]
Capacity Tons [kW]A in. [mm]B in. [mm]
381/4 [972]253/4 [654]3-5 [10.6-17.6]
Capacity Tons [kW]
3-5 [10.6-17.6]
Corner Weights by Percentage
ABCD
22%27%23%28%
ACCESSORIES
21
Heat Controller, Inc.
-21-
ACCESSORY EQUIPMENT-FIELD INSTALLED
Accessory
Description
Roofcurb 14"RXKG-BAD14
Roofcurb 24"RXKG-BAD24
Accessory
Model No.
3 to 5 Ton
Economizer with Single Enthalpy ➁
Dual Enthalpy KitRXRX-AV02
CO2Sensor OnlyRXRX-AR02
Power ExhaustRXRX-BFF04C
Fresh Air Damper ManualRXRF-FBA1
Fresh Air Damper MotorizedRXRF-FBB1
Rectangular to Round 18"
Duct Adapters for Concentric Diffuser
Rectangular to Round 20"
Duct Adapters for Concentric Diffuser
Concentric Diffuser 18" StepRXRN-FA60
Concentric Diffuser 18" FlushRXRN-FA70
Rectangular to Round 16" SideRXMC-BB01
Louver Kit (3 Sides)RXRX-AAD01B
Time DelayRXMD-B01
High PressureRXAB-A02
Low PressureRXAC-A02
NOTES: ➀ If a particular unit is to be converted to operate on LP (propane) for elevations above 2000 ft. in Canada, the existing Natural Gas to LP Conversion Kits for the
subject models already contain the necessary orifices and instructions to de-rate the input for 2000-4500 ft. Canadian applications.
➁ Economizer is designed for downflow or horizontal applications.
➀
RXRD-KECM3
RXMC-CB03
RXMC-CB04
RXGJ-EP84W
RXGJ-EP85H
RXRX-AH01
ACCESSORIES
22
Heat Controller, Inc.
-22-
ROOFCURBS (Full Perimeter)
■ This
roofcurb design can be utilized on
3 through 5 ton models.
■
Two available heights (14" and
24" for ALL models.
■
Quick assembly corners for simple and fast assembly.
■
Opening provided in bottom pan to match the
“Thru the Curb” electrical connection opening
provided on the unit base pan.
■
2" x 4" Nailer provided.
■
Insulating panels provided.
■
Sealing gasket 28" provided
with Roofcurb.
■
Packaged for easy field assembly.
Roofcurb ModelHeight of Curb
RXKG-BAD1414" [356 mm]
RXKG-BAD2424" [610 mm]
TYPICAL INSTALLATION
ROOFCURB FOR
TGC036C-TGC060C MODELS
ECONOMIZERS
ACCESSORIES
23
Heat Controller, Inc.
-23-
RXRD-KECM3—Single Enthalpy with Barometric Relief
RXRX-AV02—Dual Enthalpy Kit
RXRX-AR02—CO
■
Features Honeywell Analog Controls
■
Field installed accessory
■
Gear Driven Direct Drive Actuator
■
Fully Modulating (0-100%)
■
Low Leakage Dampers
■
Horizontal or Downflow Applications
■
Slip-In Design for Easy Installations
■
Plug-In Polarized 9-pin Electrical Connections
■
Pre-configuring—No Field Adjustments Necessary
■
Standard Barometric Relief Damper Provided
■
Single Enthalpy with Dual Enthalpy upgrade kit
■
CO2Input Sensor Available
■
Economizer slips in complete for downflow or
Sensor
2
horizontal duct applications
■
Field assembled hood ships with Economizer
■
Optional Remote minimum position
■
Field installed power exhaust available.
ACCESSORIES
24
Heat Controller, Inc.
-24-
INTEGRAL POWER EXHAUST FOR ECONOMIZER
RXRX-BFF04C—208/230V-1phase
■
For Honeywell economizer.
■
Downflow or horizontal applications.
■
Requires separate 208-230 volt – 1 PH power supply
with disconnect.
■
Adjustable switch on economizer, factory preset to energize
power exhaust at 95% outside air position.
■
Polarized plug connects power exhaust relay to economizer.
Illustration
ST-A0903-01
POWER EXHAUST KIT SPECIFICATIONS
Model No.No. of FansVoltsPhaseWatts (ea.)
RXRX-BFF04C1
➀ CFM is at 0" W.C. external static pressure.
208-230
12402600
FRESH AIR DAMPER
RKNA 3-5 Ton [10.6-17.6 kW] Models
RXRF-FBA1 (Manual)
RXRF-FBB1 (Motorized)
CFM ➀
High Speed
RPM
1700
FLA (ea.)LRA (ea.)
1.06
1.9
I319.DGN
FRESH AIR DAMPER
DUCT ADAPTERS
ACCESSORIES
25
Heat Controller, Inc.
-25-
RXMC-CB03 sizes available
18" fit all units.
Drops into and secures to
RXKG- Series Roofcurbs.
Single Stage Cool w/o EconomizerTwo Stage Cool w/Economizer
Maple Chase—Model #0970Honeywell—Model #T7300-A1005
Honeywell—Model #T8602CHoneywell—Model #T874D-1959
Maple Chase—Model #0960
White Rodgers—Model #1F91-59
Robertshaw—Model #CM64A-USAJ