1. BEFORE USE............................................................ 3
2. QUICK SET UP.......................................................... 4
3. INTRODUCTION........................................................ 5
4. SUGGESTIONS FOR USE ........................................ 5
5. SPECIFICATIONS...................................................... 6
6. PARTS & ACCESSORIES ......................................... 7
7. SAFETY ..................................................................... 8-9
8. INSTALLATION.......................................................... 10-11
9. OPERATION .............................................................. 12-17
10. DRAIN EXCESS CONDENSATE WATER ............................. 18
11. MAINTENANCE..................................................................... 19-20
12. TROUBLESHOOTING GUIDE............................................... 21
9.1 Control Panel................................................................
9.2 Remote Controller........................................................
9.3 Operation in Auto, Cool, Heat, Dry & Fan Mode........
9.4 Timer Setting Procedure..............................................
9.5 Air Flow Direction Control...........................................
12 13
14-15
16 17
13. WIRING DIAGRAM………………………………………………. 22
2
Heat Controller, Inc.
1900 Wellworth Avenue  Jackson, MI 49203
BEFORE USE
READ THIS ENTIRE INSTRUCTION MANUAL BEFORE USE
Keep your ORIGINAL purchase
receipt.
Your receipt is your proof of
purchase and may be necessary
for warranty service.
! A TTENTION !
This manual describes installation, operation, and maintenance of the portable air conditioner product.
If you need assistance, please call:
CUSTOMER SERVICE
1-517-787-2100
FOR FUTURE REFERENCE, PLEASE RECORD THE FOLLOWING:
Model No.:
Serial No.:_________________
Date of Purchase: _______________________________
________________________________________________
Heat Controller, Inc.
3
1900 Wellworth Avenue  Jackson, MI 49203
2.
QUICK SET UP
Unpack the unit:
Remove the foam cap.
With two people, lift and
remove the unit from the foam packing base without tilting the unit.
Remove the plastic bag.
Test LCDI Plug. (Ref. Section 7, Safety Rules).
Check to see if unit is complete including all parts and accessories (Ref. Section 6, Parts & Accessories).
Place the unit UPRIGHT to allow the refrigerant and oil to stabilize. Wait 3 hours before using. (Ref. Section 7, Safety).
Attach air inlet and air outlet hose. Follow instructions per Section 8, Installation.
Plug the unit into a properly grounded 15 Amp, 115V AC, circuit. (Ref. Section 7, Safety Rules).
Follow Section 9, Operation to set preferred function mode. When Water-Full indicator illuminates, empty the residual condensate water. (Ref. Section 10, Drain Excess Condensate Water).
Handle your unit with care. Move it gently. Always keep air filter clean. Do not cover air inlet grid and air outlet grid.
Heat Controller, Inc.
4
1900 Wellworth Avenue  Jackson, MI 49203
3.
This Portable Air Conditioner is designed for improving living and working comfort by adjusting the temperature and humidity in a room. Its mobility makes it easy to use in various rooms.
This unit is provided with one outside air inlet hose and one hot-air outlet hose to enhance cooling performance. This unit has an Auto Restart function. In case of power failure, the unit will restart in the last setting selected when power resumes.
To ensure the optimal efficiency of the air conditioner, keep doors and windows closed. In order to optimize the functioning of your air conditioner, close window coverings to minimize sun load in the room.
INTRODUCTION
This unit has a three-minute compressor delay protection circuit
4.
1. This unit is designed for use indoors only and is not intended for outdoor use.
2. Do not locate the unit where furniture or other objects can obstruct the cooling airflow on back or above unit.
3. Prevent any kink or sharp bend in the air inlet and hot-air outlet hoses.
4. Unit must always be used in an upright position.
5. After unpacking, place the unit upright to allow the refrigerant and oil to stabilize. Wait 3 hours before using.
6. Place the unit on the floor not on a table or other elevated surface.
7. Keep the filter clean.
SUGGESTIONS FOR USE
Heat Controller, Inc.
5
1900 Wellworth Avenue  Jackson, MI 49203
5.
SPECIFICATIONS
PE-91A / PE-121A
Electrical Supply 115V / 60 Hz
Cooling Capacity (BTUH) 9000 / 12000
Heating Capacity (BTUH) 3412 / 4265
Cooling Amps 10.0 / 11.5
Heating Amps 8.7 / 10.9
Dehumidifying Capacity (Pts/Hr) 2.5 / 2.8
Refrigerant R22
Fan Speeds Low / Med / Hi
Airflow (CFM) 210
Noise Level dB(A) 51 / 52
Net Weight (lb) 85.5 / 87.5
Product Dimension (in) 19.1(W) x 19.4(D) x 31.9(H)
Max. Length of Air Inlet and Outlet Hose (in) 71
Programming Timer (hr) 1 - 24
Heat Controller, Inc.
6
1900 Wellworth Avenue  Jackson, MI 49203
a.
6.
PARTS & ACCESSORIES
Upper drain port
Lower drain port (Rubber plug inside)
Heat Controller, Inc.
7
1900 Wellworth Avenue  Jackson, MI 49203
Loading...