IMPORTANT SAFETY INSTRUCTIONS
Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner. You'll find many answers to common problems in the chart of troubleshooting tips. If you review our chart of Troubleshooting Tips first, you may not need to call for service at all.
To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications.
This symbol indicates the possibility of death or serious injury.
Always do this.
Never do this.
CAUTION
This symbol indicates the possibility of injury or damage to property.
WARNING
WARNING
Plug in power plug properly.
Do not modify power cord length or share the outlet with other appliances.
Always ensure effective grounding.
Unplug the unit if strange sounds, smell, or smoke comes from it.
Keep firearms away.
Ventilate room before operating air conditioner if there is a gas leakage from another appliance.
Otherwise, it may cause electric shock or fire due to excess heat generation.
It may cause electric shock or fire due to heat generation.
Incorrect grounding may cause electric shock.
It may cause fire and electric shock.
It may cause fire.
It may cause explosion, fire and, burns.
It may cause electric shock or fire due to heat generation.
It may cause electric shock.
It may cause failure of machine or electric shock.
It may cause fire and electric shock.
It may cause fire and electric shock.
It may cause electric shock or fire. If the power cord is damaged, it must be replaced by the manufacturer or an authorised service centre or a similarly qualified per son in order to avoid a hazard.
This could damage your health.
Incorrect installation may cause fire and electric shock.
It may cause electric shock.
It may cause an explosion or fire.
It may cause failure and electric shock.
Do not operate or stop the unit by inserting or pulling out the power plug.
Do not operate with wet hands or in damp environment.
Do not allow water to run into electric parts.
Do not use the socket if it is loose or damaged.
Do not use the power cord close to heating appliances.
Do not damage or use an unspecified power cord.
Do not direct airflow at room occupants only.Always install circuit breaker and a dedicated power circuit.
Do not open the unit during operation.
Do not use the power cord near flammable gas
or combustibles, such as gasoline, benzene,
thinner, etc.
Do not disassemble or modify unit.
!
!
!
!
!
!
!
!
READ THIS MANUAL
Owner’s Manual Room Air Conditioner with R-410A Heat Controller
3
When the air filter is to be removed, do not touch the metal parts of the unit.
It may cause an injury.
Do not clean unit when power is on as it may c ause fi re an d el ectric sh ock, it may cause an injury.
Operation with windows opened may cause wetting of indoor and soaking of household furniture.
When the unit is to be cleaned, switch off, and turn off the circuit breaker.
Use caution when unpacking and installing. Sharp edges could cause injury.
Do not clean the air conditioner with water.
Water may enter the unit and degrade the insulation. It may cause an electric shock.
This could injure the pet or plant.
It may cause electric shock and damage.
Do not put a pet or house plant where it will be exposed to direct air flow.
Ventilate the room well when used together with a stove, etc.
An oxygen shortage may occur.
Do not use this air conditioner to preserve precision devices, food, pets, plants, and art objects.It may cause deterioration of quality, etc.
It may cause failure of product or fire.
Do not use for special purposes.
If water enters the unit, turn the unit off at the power outlet and switch off the circuit breaker. Isolate supply by taking the power-plug out and contact a qualified service technician.
!
!
!
!
It may cause failure of appliance or accident.
Appearance may be deteriorated due to change of product color or scratching of its surface.
If bracket is damaged, there is concern of damage due to falling of unit.
There is danger of fire or electric shock.
Operation without filters may cause failure.
It contains contaminants and could make you sick.
Stop operation and close the window in storm or hurricane.
!
Do not use strong detergent such as wax or thinner but use a soft cloth.
Ensure that the installation bracket of the outdoor appliance is not damaged due to prolonged exposure.
Hold the plug by the head of the power plug when taking it out.
!
Turn off the main power switch when not using the unit for a long time.
!
!
!
Always insert the filters securely. Clean filter once every t wo w eeks.
!
Do not place heavy object on the power cord and ensure that the cord is not compressed.
Do not drink water drained from air conditioner.
This appliance is not intended for use by persons (including children) with reduced physical ,sensory or mental capabilities or lack of experience and knowledge, unless t hey h ave b een gi ven supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
CAUTION
CAUTION
Do not place obstacles around air-inlets or inside of air-outlet.
The appliance shall be installed in accordance with national wiring regulations.
Do not operate your air conditioner in a wet room such as a bathroom or laundry room. The appliance with electric heater shall have at
l east 3 ft. s pace to th eco mbustible materials.
Contact the authorized service technician for
repair or maintenance of this unit.
Contact the authorized installer for installation
of this unit.
IMPORTANT SAFETY INSTRUCTIONS
Heat Controller Room Air Conditioner with R-410A Owner’s Manual
4
Do not, under any circumstances, cut, remove, or bypass the grounding prong.
Power supply cord with 3-prong grounding plug and current detection device
Grounding type wall receptacle
WARNING
NOTE:
The power supply cord with this air conditioner contains a current detection device designed to reduce the risk of fire. Please refer to the section Operation of Current Device for details.In the event that the power supply cord is damaged, it cannot be repaired-it must be replaced with a cord from the Product Manufacturer.
Avoid fire hazard or electric shock. Do not use an extension cord or an adaptor plug. Do not remove any prong from the power cord.
WARNING
For Your Safety
WARNING
Prevent Accidents
WARNING
Electrical Information
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
Operation of Current Device
(Applicable to the unit adopts current detection device only )
The power supply cord contains a current device that senses damage to the power cord. To test your power supply cord do the following:
1. Plug in the Air Conditioner.
2. The power supply cord will have TWO buttons on the plug head. Press the TEST button, you will notice a click as the RESET button pops out.
3. Press the RESET button, again you will notice a click as the button engages.
4. The power supply cord is now supplying electricity to the unit. (On some products this it also indicated by a light on the plug head.)
To reduce the risk of fire, electrical shock, or injury to persons when using your air conditioner, follow basic precautions, including the following: Be sure the electrical service is adequate for the model you have chosen. This information can be found on the serial plate, which is located on the side of the the cabinet and behind the grille. If the air conditioner is t o b e in stalled in a w indow, yo u w ill pr obably w ant to cl ean both sides of the g lass f irst. If th e w indowis a tri ple-track ty pe w ith a sc reen pa nel included, remove the screen completely before installation. Be sure the air c onditioner h as b een s ecurely a nd c orrectly in stalled a ccording to the installation instructions in this manual. Save this manual for possible future use in removing or installing this unit. When handling the air conditioner, be careful to avoid cuts f rom s harp m etal f ins on front and rear coils.
The complete electical rating of your new room air conditioner is stated on the serial plate. Refer to the rating when checking the electrical requirements. Be sure the air conditioner is properly grounded. To minimize shock and fire hazards, proper grounding is important. The power cord is equipped with a three-prong grounding plug for protection against shock hazards. Your air conditioner must be used in a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the proper receptacle. Ensure the receptacle is accessible after the unit installation. Do not run air conditioner without side protective cover in place.This could result in mechanical damage within the air conditioner. Do not use an extension cord or an adapter plug.
IMPORTANT SAFETY INSTRUCTIONS
Do not use this device to turn the unit on or off. Always make sure the RESET button is pushed in for correct operation. The power supply must be replaced if it fails reset when either the TEST button is pushed, or it cannot be reset. A new one can be obtained from the product manufacturer. If power supply cord is damaged, it cannot be repaired. It MUST be replaced by one obtained from the product manufacturer.
NOTE:
NOTE:This air conditioner is designed to be operated
under condition as follows:
Cooling operation
Outdoor temp:
Indoor temp:
Heating operation
Outdoor temp:
O
O
23-76 F/-5-24 C
Indoor temp:
O
O
32-80 F/0-27 C
OO OO
64-109 F/18-43 C (64-125 F/18-52 C for special tropical models)
O
O
62-90 F/17-32 C
Note: Performance may be reduced outside of these operating temperatures.
Owner’s Manual Room Air Conditioner with R-410A Heat Controller
5
1
/
2
1
/
2
1
/
2
1
/
2
1
/
2
1
/
2
1
/
2
1
/
2
INSTALLATION INSTRUCTIONS
Read these instructions completely and carefully.
IMPORTANT-
Save these
instructions for local inspector s use.
IMPORTANT-
Observe all
governing codes and ordinances.
Note to Consumer-
Keep these
instructions for future reference.
Note to Installer-
Be sure to leave these
instructions with the Consumer.
Completion time-
Approximately 1 hour.
Skill level-
Installation of this appliance
requires basic mechanical skills.
We recommend that two people install this product. Proper installation is the responsibility of the installer. Product failure due to improper installation is not covered under the Warranty. You MUST use all supplied parts and use proper installation procedures as described in these instructions when installing this air conditioner.
BEFORE YOU BEGIN
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.
CAUTION
Do not change the plug on the power cord of the air conditioner.
Aluminum house wiring may present special problems- consult a qualified electircian.
When handling unit, be careful to avoid cuts from sharp metal edges and aluminum fins on front and rear coils.
Save Carton and these Installation Instructions for future reference. The carton is the best way to store unit during winter, or when not in use.
NOTE:
Note that the air conditioner dimensions are: 24 inches
wide, 14 inches high, and 18 inches deep(without front).
Install Air Conditioner according to these installation instructions to achieve the best performance. Save these installation instructions for future reference. NOTE: Do not use any screws other than those specified here.
Do This First (for existing sleeve)
Items in Kit
You may not need all parts in the kit. Discard unused
parts.
Name
Spec.
Qty
Tapered Spacer Blocks
17 Long
2
Centering/Support Blocks
4 x3 x1
4
Plastic Divider
1/8 x4 x14
2
Stuffer Seal
1 x1 x84
1
Seal 1 x1 x25
1 x1 x14 1 x3/8 x25
Seal Seal Seal
1 x3/8 x14 1 x3/4 x14
Seal
3
3
2
2
2
Trim Frame(side legs)
Trim Frame(top & bottom legs) Ground Wire(green) Toothed Washer for grounding
screw
Grounding Screw Grille(plastic)
Grille Aluminum Nuts(plastic) Screw Washer Screw
2 2
1
2
1 1 1 4 4 4
Heat Controller Room Air Conditioner with R-410A Owner’s Manual
6
How to Install
1. Identify the wall-sleeve brand for your installation, from the chart below.
Bran d Wall Sle eve Dimensions (inc hes) Widt h Height Dept h
Whit e-Westinghouse Frigidaire Carrier(52F Series) General Electric/Hotpoint Whirlpool Fedders/Emerson Sears/Kenmore Carrier(51S Series) Emerson/Fedders Friedrich
1
/
2
25 15 16 ,17 or 22
1
/
2
1
/
4
26 15 15
7
/
8
5
/
8
7
/
8
25 16 17 or 23
1
/
8
1
/
2
3
/
4
27 16 16 or 19
3
/
4
3
/
4
3
/
4
25 16 18
5
/
8
7
/
8
3
/
4
26 15 15
3
/
4
/
27 16 16
3
4
3
/
4
NOTE: All wall sleeves used to mount the new Air Conditioner must be in sound structural condition and have a rear grille that securely attaches to sleeve, or rear flange that serves as a stop for the Air Conditioner.
CAUTION: When installation is complete, replacement unit MUST have a rearward slope as shown.
REAR
LEVEL
FRONT
UNIT
Wall Sleeve
1
/
4 to
5
/
16
2. Remove old Air Conditioner from wall sleeve and prepare wall sleeve as follows:
--- Clean interior (do not disturb seals).
--- Wall sleeve must be securely fastened in wall before installing Air Conditioner. Drive more nails or screws through sleeve, into wall, if needed.
--- Repair paint if needed.
3. If not existing, drill a 1/8 clearance hole for grounding screw through left side of wall sleeve, in a clear area about 3 inches maximum back from front edge of sleeve, using grounding screw and toothed washer. Pull loose end of ground wire out front of sleeve, and temporarily bend it down and around lower edge of sleeve.This ground wire will later be attached to frame of air conditioner once it is installed.
Wall sleeve to unit sleeve grounding
1
3 Max.
1/8 Hole
4. Prepare the wall sleeve for installation of the new unit per the following Brand instructions. #1 Em erson 15 Deep #2 Fe dders 19 Deep #3 Fe dders or Friedrich 16 De ep #4 General Electric/Hotpoint 16 Deep #5 Sears or Carrier(51S Series) 18 Deep #6 Wh irlpool 17 Deep #7 Wh irlpool 23 Deep #8 Wh ite-Westinghouse / 16 +17 De ep Frigidaire/Carrier(52F Series) #9 White-Westinghouse/Frigidaire 22 Deep
3
/4/
4
7
/8/
3
/
4/4
5
/8/
1
/
8
/
1
/
/
2
5. Identify your wall sleeve type and follow the instructions for that type in the following pages.
INSTALLATION INSTRUCTIONS
Owner’s Manual Room Air Conditioner with R-410A Heat Controller
7
This units increased performance characteristics result from having two rear air intakes. It is very important that these installation instructions are followed so your unit can operate at maximum efficiency. If this is an existing sleeve, and there is an existing rear grille, it needs to be replaced by one that has been shipped with the unit in the accessory kit.
FOR INCREASED EFFICIENCY,UTILIZE THE PROVIDED LOUVERED REAR PANEL
Installation of new grille provided with unit
1. Remove the existing grille.
2. Place the grille included with the new air conditioner towards the rear of the sleeve.
3. Mark through the hole positions.
4. Drill through the sleeves flanges with a 1/8 drill bit.
5. Attached the new grille with self-threading screws and washers.
6. It is VERY IMPORTANT that the grille is placed exactly as shown below.
7.Most decorative exterior grilles may be left in place as long as the proper interior air direction grille is installed.
INSTALLATION INSTRUCTIONS
IMPORTANT