HearthStone 8120 Owner's Manual And Installation Manual

Operate and maintain this gas heater according to this instruction manual.
g
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
Do not store or use gasoline or other flammable vapors and liquids near this or any other gas appliance.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch electrical switches; do not use the
phone in your building.
Immediately call your gas supplier from a neighbor’s phone. Follow your gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire department or 911.
A qualified installer, service agency or gas supplier must perform installation and service. In the Commonwealth of Massachusetts, all installation of gas lines and gas fitting must be done by a licensed gas fitter or licensed plumber.
Tudor (Model 8120)
GAS-FIRED, DIRECT-VENT HEATER
Owner’s Manual
Installation Guide
READ THIS OWNER’S MANUAL
AVERTISSEMENT: Assurez-vous de bien suivre les instructions donné dans cette notice pour réduire au minimum le risque d’incendie ou pour éviter tout dommage matéeriel, toute blessure ou la mort.
Ne pas entresposer ni utiliser d’essence ni d’autre vaperurs ou liquides inflammables dans le voisinage de cet apprareil ou de tout autre appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
Ne pas tenter d’allumer d’appareil.
Ne touchez à aucun interrupteur. Ne pas vous
servir des téléphones se trouvant dans le batiment où vous vous trouvez.
Appelez immédiatement votre fournisseur de gaz depuis un voisin. Suivez les instructions du fournisseur.
Si vous ne pouvez rejoindre le fournisseur de gaz, appelez le service dos incendies.
L’installation et service doit être exécuté par un qualifié installer, a fournisseur de gaz.
ence de service ou le
Tudor Model 8120
Manual: 6400-40453
Revised: 06/25/2008
Hearthstone Quality Home Heating Products, Inc. Tudor Model #8120
INFORMATION SHEET
Use this page to record all relevant information concerning the purchase, installation, and maintenance of your Tudor Gas-Fired Direct-Vent heater. This information will facilitate servicing, purchase of replacement parts, and warranty claims (if necessary). Keep your original receipt in a safe place as proof of purchase.
Serial Number:
Fuel type (check one)
Sold by:
Phone:
Installed by: Phone:
Gas Supplier: Phone:
Read this Owner’s Manual before installing or operating the Tudor. Retain this manual for future reference.
Natural Gas Liquid Propane
Date of Purchase:
Date of Installation:
SERVICE RECORD
Important - Verify proper operation after servicing!
Date Person Performing Work Work Performed Notes:
WHAT WHEN WHAT WHEN
Firebox Cleaning............. annually Door Gasket............... Replacement as
needed
Glass Cleaning................ as needed
2
Hearthstone Quality Home Heating Products, Inc. Tudor Model #8120
TABLE OF CONTENTS
INTRODUCTION ...........................................................3
SPECIFICATIONS:.........................................................5
OWNERS INFORMATION ..............................................6
INSTALLERS INFORMATION..........................................7
ITEMS REQUIRED FOR INSTALLATION ...........................7
UNPACKING AND INSPECTION.......................................7
CLEARANCE TO COMBUSTIBLES ....................................8
VENTING INFORMATION.............................................11
ELECTRICAL CONNECTIONS........................................15
GAS SUPPLY & CONNECTIONS....................................18
REFRACTORY PANEL INSTALLATION............................18
LOG SET INSTALLATION.............................................19
LIGHTING THE UNIT FOR THE FIRST TIME ..................21
INITIAL ADJUSTMENTS...............................................21
ROUTINE MAINTENANCE AND CARE............................24
PARTS LISTS .............................................................26
LIMITED WARRANTIES...............................................31
INTRODUCTION
Congratulations on your purchase of Hearthstone’s Tudor Gas-Fired Direct Vent heater. The Tudor incorporates the latest in balanced vent gas technology, which will provide you with clean, efficient heat for years to come. Combustion air comes directly from the outside of your home to the sealed firebox system, eliminating the potential for annoying back drafts or other problems associated with home depressurization.
The Tudor will provide you with years of practical and convenient service. However, as with any gas appliance, the unit must be properly and safely installed and maintained by qualified service personnel to ensure safe and trouble-free operation. It includes the new TEK Firelog technology, which is an amazing blend of realistic flames and glowing embers with incredible heating characteristics.
READ THIS OWNERS MANUAL
Operate and maintain this gas heater according to the instructions in this manual. For your safety, and years of trouble free operation, read this manual in its entirety. By following a few simple safety precautions and by performing minimal maintenance, the unit will remain appealing while providing years of quality performance.
WARNING! A qualified service technician should do installation, and repair. A qualified service technician must inspect the appliance before use, and at least annually. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, pets, etc. It is imperative that the control compartments, burners, and circulating air passages of the appliance are kept clean and free of obstructions.
(S’assurer que le brûleur et le compartiment des commandes sont propres. Voir les instructions d’installation et d’utilisation qui accompagnent l’appareil.)
WARNING: Do not operate this appliance with the glass, or any panel removed, cracked, or broken. Do not subject the door to abuse, such as striking or slamming shut. Replacement of the glass panel should be done by a licensed or qualified service person.
NEVER BURN PAPER, WOOD OR OTHER MATERIALS
This gas heater is designed to burn natural gas or liquid propane (LP). Never burn any fuel not intended for use with this unit.
HOT SURFACES
Certain exposed surfaces of the Tudor will reach high temperatures during normal operation. Clearances to combustibles must be maintained, as specified in the “Clearances To Combustibles” section of this manual.
Do not use this appliance if any part was under water. Immediately call a qualified service technician to inspect the heater and to replace any part of the control system and gas control that was under water. (
appareil s’il a été plongé dans l’eau, complétement ou en partie. Appeler un technicien qualifié pour inspector l’appareil et remplacer toute partie du systéme de contrôle et toute commande qui ont été plunges dans l’lau.)
Ne pas se servir de cet
3
Hearthstone Quality Home Heating Products, Inc. Tudor Model #8120
WARNING
This gas appliance must not be connected to a chimney flue serving a separate solid-fuel burning appliance.
ROOMS OR BUILDINGS
Masonry Conversions Kits are an acceptable venting option.
NEVER VENT THE GAS HEATER TO OTHER
.
Due to high temperatures the appliance should be located out of traffic and away from furniture, draperies, clothing and flammable materials. Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns to skin or clothing ignition. Young children should be carefully supervised when in the same room as the appliance. Clothing or other flammable material should not be placed on or near the appliance.
(Surveille les enfants.
Garder les vêtements, les meubles, l’essence ou autres liquides à vapeur inflammables lin de l’appareil.)
F
IRE HAZARD
Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this appliance. The Tudor should be located out of traffic and away from furniture, draperies, clothing, and flammable material.
Any shield, door, or safety screen component removed for servicing must be replaced prior to operating the unit.
Certified for use by:
Board of State Examiners of Plumbers and Gasfitters 100 Cambridge Street, Room 1511 Boston, Massachusetts 02202
4
Hearthstone Quality Home Heating Products, Inc. Tudor Model #8120
SPECIFICATIONS:
LISTED AS: Gas-Fired Direct-Vent Fireplace Heater Model: Tudor Direct-Vent Gas Fireplace Heater (8120) Testing Agency: OMNI-Test Laboratories, Inc. Tested to: ANSI Z21.88-B 2003, CSA 2.33-M02, CAN/CGA2.17-M91
Certified for Canada, CSA P.4.1 Approved for Mobile Home Installation
FUEL TYPE:
INPUT RATING (Btu/hr) 0-2000 ft 11,500 11,200 ORIFICE SIZE (DMS) 0-2000 ft 53 63 MANIFOLD PRESSURE - LO SETTING (in. W.c./kpa) 1.6/0.42 6.4/1.59 MANIFOLD PRESSURE - HI SETTING (in. W.c./kpa) 3.5/1.15 10.0/2.48 INLET PRESSURE - LO (in.w.c./kpa) 5.0/1.24 11.0/2.88 MINIMUMINPUT RATING (btu/hr) 7000 8500 MAXIMUMOUTPUT (btu/hr) 0-2000 ft 7652 7494
Figure 1 Tudor Dimensions
NG LP
5
Hearthstone Quality Home Heating Products, Inc. Tudor Model #8120
OWNERS INFORMATION
The installation must conform with local codes or, in the absences of local codes, the current National Fuel Gas Code, ANSI Z223.1 (NFPA 54) or CAN/CGA B149 Installation Code.
ou règlements locaux, ou, en l’absence de tels règlements, selon les Codes d’installation CAN/CGA­B149.)
Do not use this appliance if any part was under water. Immediately call a qualified service technician to inspect the heater and to replace any part of the control system and gas control that was under water. (Ne pas se servir de cet appareil s’il a été
plongé dans l’eau, complètement ou en partie. Appeler un technicien qualifié pour inspector l’appareil et remplacer toute partie du système de contrôle et toute commande qui ont été plongés dans l’lau.)
DAILY OPERATION
The Tudor is easily operated by the homeowner once installed and adjusted by qualified service personnel. The unit can be controlled via the wall­mounted thermostat during the heating season. Set the thermostat to the desired room temperature and the unit will cycle on and off as required. By adjusting the variable output control located on the gas control valve, the rate of heat output can be varied to meet the heating requirements of the season. Choosing a low flame setting will result in longer burn cycles at a reduced output, while choosing a high flame setting will result in a shorter, hotter burn cycle. Through trial and error, the homeowner can select the optimum flame size for their setting and application.
During the summer non-heating season, switch the wall thermostat to “OFF”, and turn off the pilot. This will improve the overall efficiency of the unit as the heat from the pilot is wasted. When putting the unit back into service, follow the lighting instructions described on page
When the unit is first lit, especially when cool, it is normal to experience some condensation on the inside of the window glass. This condensation will burn off within the first few minutes of operation. If continuous condensation on the window glass or dripping water from any part of the unit or venting system (chimney) is noted, immediately discontinue operation of the unit and contact qualified service personnel.
(Installer l’appareil selon les codes
22.
Clean the area around, under, and behind the unit on a regular basis to prevent the accumulation of dust and lint.
The Tudor requires minimal routine maintenance and care. It should always be cool and off when being cleaned, or serviced. Once a year, the unit, and venting system should be inspected by qualified service personnel to insure that they are clean, free of obstruction, safe, and in good working order. If service or maintenance is required, qualified service personnel should perform it.
SERVICE CAUTION
If you believe your Tudor is not, in any way, performing properly, immediately discontinue operation until the unit is inspected and approved by qualified service personnel. Prior to servicing the unit, turn the valve control knob clockwise to “OFF”. The unit should be cool prior to servicing and cleaning. Use of any components not supplied by Hearthstone on the stove voids all warranties. Do not substitute components.
6
Hearthstone Quality Home Heating Products, Inc. Tudor Model #8120
INSTALLERS INFORMATION
CODES
Adhere to all local codes or, in their absence, the latest edition of THE NATIONAL FUEL GAS CODE ANSI Z223.1 (NFPA 54) or CAN/CGA B149 Installation Code that can be obtained from:
AMERICAN NATIONAL STANDARDS
INSTITUTE, INC.
1430 BROADWAY
NEW YORK, NY 10018
OR
NATIONAL FIRE PROTECTION ASSOCIATION,
INC.
BATTERY MARCH PARK
QUINCY, MA 02269
A manufactured home (mobile) OEM installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (U.S.) or Standard for Manufactured Home Installation, ANSI/NCBCS A225.1 or Standard for Gas Equipped Recreational Vehicles and mobile Housing, CSA Z240.4.CAN/SCA Z240 MH (Canada).
(Installer l’appareil selon les codes ou règlements locaux, ou, en l’absence de tels règlements, selon les Codes d’installation CAN/CGA-B149.)
ITEMS REQUIRED FOR INSTALLATION
* External regulator (for propane/L.P.G. only) * Piping which complies with local codes * Pipe sealant approved for use with propane/L.P.G. (resistant to sulfur compounds) * Manual shutoff valve * Sediment trap (see page 18) * Tee joint * Pipe wrench * Phillips head screwdriver * Flat tip screwdriver * 7/16-inch wrench * Other parts as required by local code *Safety Glasses *Gloves
PACKING LIST
1-Tudor Gas-Fired Heater 1-TEK Burner 2-Decorative TEK Firelogs 4-Refractory Panels 1-Tudor top casting 1-Owner’s Manual
1-Thermostat 1-40’ Thermostat wire 1-Wall thimble Insulation Blanket 1-Warranty Validation Form
Note: Vent kits and components are supplied separately. specified by HearthStone QHHP, Inc. will void your warranty and could risk a fire.
Failure to use the venting components
UNPACKING AND INSPECTION
Unpack and Inspect for Damage
The Tudor is packaged by the manufacturer to withstand shipment without damage. However, damage can still occur during transit; so take care to inspect for damage when unpacking and installing the unit. If any damage or missing parts are detected, immediately contact your dealer.
Do not install, or put into service, a damaged or incomplete heater.
The Tudor requires a pilot shield. This shield is shipped with the unit. Make sure the sure the shield is installed over the pilot with the open end is to the right (when you are facing the front of the stove)
Inspect the Tudor for visible or concealed damage. The unit should appear to be square and true. The sheet metal parts should be smooth and free of bends and dents. The enameled cast iron should be free of chips or cracks. If visible or concealed damage is found or suspected, contact your dealer for instructions.
With the accessory box removed and set aside, take care not to mar or chip the enameled legs, if applicable. Have someone help lift the stove out of the shipping box and set it into place. The TEK Burner and TEK Firelogs supplied with the Tudor are contained in the accessory box. The inner refractory panels are wrapped and are in the firebox. Always use great care when handling the decorative fire logs and inner panels, as they are fragile and subject to damage and breakage if handled roughly. If a broken log or panel is encountered, contact your dealer for replacements. Otherwise, set the logs and panels aside until called for during the installation.
7
Hearthstone Quality Home Heating Products, Inc. Tudor Model #8120
INSTALLING THE TUDOR
A complete Tudor REQUIRES the purchase of one of the following panel kits;
91-8220010 Curio Matte (cast iron) 91-8220020 Curio Brown 91-8220059 Curio Blue/black
91-8220310 Keepsake Matte (grill + cast) 91-8220320 Keepsake Brown 91-8220359 Keepsake Blue/black
91-8220641 Heirloom Polished (stone) 91-8220653 Heirloom Brown
91-68200 Tile Insulation kit (Must be used
with self purchased tiles) do not paint, plaster or finish the tiles in any way. This may risk off­gassing or a fire.
HEARTH REQUIREMENT/FLOOR PROTECTION
The Tudor may be placed on any surface or wood
floor, carpeting, or vinyl tile, with or without legs. Installations must meet local codes.
Removing the Tudor’s legs
The Tudor has the unique possibility of having its legs removed, allowing for the unit to rest on its base. To do this, simply use two 7/16” wrenches or ratchets and loosen and remove the two centermost ¼-20 bolts and nuts holding the legs
on. These can be reached the easiest from behind the unit and should be removed prior to any other connections have been made. Once removed, lift the unit off the legs and set in the desired location.
C C
LEARANCE TO OMBUSTIBLES
Due to high surface temperatures, the unit should be located out of traffic and away from furniture and draperies. Clothing and other flammable material should not be placed on or near the heater. When positioning the unit always maintain adequate clearances around air openings into the combustion chamber and allow for adequate ventilation. Minimum clearances to combustibles must be maintained as shown in the illus
Clearances To Combustibles
the Be sure to consider the need for access to the gas
control valve access door on the front of the unit as well as fu servicing.
C
minimum
through testing in an independent laboratory to ANSI and CSA stand will prevent fire or spontaneous combustion. We do not control the combustible materials exposed to heat b this product; therefore, an assessment must be made by the installer to pre conseque flooring.
ll access for periodic cleaning and
aution: These clearances represent
distances in all cases, wh
ntial damage of walls and
section.
trations of
ich,
ards,
y
vent
8
Hearthstone Quality Home Heating Products, Inc. Tudor Model #8120
* For fully operational doors use a 3" corner
Clearance To Combustibles and
Alcove Dimensions.
Minimum Alcove height is 40"
clearance
Figure 2 Clearance to combustibles
Mantle clearance
Insulation blanket
Termination cap
Wall pass through
Minumum Venting Components
-Rear wall clearance = 0"
6" straight
Figure 3 Minimum vent clearances
9
Hearthstone Quality Home Heating Products, Inc. Tudor Model #8120
Acceptable Direct-Vent TERMINATION Cap locations.
Figure 4 Termination clearances
10
Loading...