Hearth Home TREKKER-MBK, TREKKER-PBK, TREKKER-PDB, TREKKER-PFT, TREKKER-PMH Installation Manual

...
R
Installation Manual
Installation and service of this appliance should be performed by qualified personnel. Hearth & Home Technologies recommends HHT Factory Trained or NFI certified professionals.
Installation & Appliance Set-Up
INSTALLER: Leave this manual with party responsible for use and operation. OWNER: Retain this manual for future reference.
NOTICE: DO NOT DISCARD THIS MANUAL
If the information in these instructions is
TREKKER FREE STANDING
PELLET APPLIANCE
MODEL(S):
TREKKER-MBK
TREKKER-PBK TREKKER-PDB
TREKKER-PMH
TREKKER-TWL
Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this or any other appliance.
Do not over re - If appliance or chimney connector
glows, you are over ring. Over ring will void
your warranty.
Comply with all minimum clearances to combustibles
as specied. Failure to comply may cause house re.
not followed exactly, a re could result
causing property damage, personal injury, or death.
WARNING
CAUTION
Check building codes prior to installation.
Installation MUST comply with local, regional, state and national codes and regulations.
Consult local building, re o󰀩cials or authorities having jurisdiction about restrictions, installation inspection, and permits.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during operation AND cool down. Hot glass will cause burns.
Do not touch glass until it is cooled
NEVER allow children to touch glass
Keep children away
CAREFULLY SUPERVISE children in same room
as replace.
Alert children and adults to hazards of high temperatures
High temperatures may ignite clothing or other
ammable materials.
Keep clothing, furniture, draperies and other
ammable materials away.
CAUTION
Tested and approved for wood pellets only. Burning of any other type of fuel voids your warranty.
1 01/217080-165J
NOTE: To obtain a French translation of this
manual, please contact your dealer or visit
www.quadrare.com
REMARQUE : Pour obtenir une traduction française de
ce manuel, s’il vous plaît contacter votre revendeur ou visitez www.quadrare.com
TREKKER
Safety Alert Key:
DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury.
WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury.
CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE: Indicates practices which may cause damage to the appliance or to property.
TABLE OF CONTENTS
1 Important Safety Information
A. Appliance Certication . . . . . . . . . . . . . . . . . . . . . . . . . .3
B. BTU & E󰀩ciency Specications ...................3
C. Glass Specications............................4
D. Electrical Rating...............................4
E. Mobile Home Approved .........................4
F. Non-Combustible Materials ......................4
G. Combustible Materials ..........................4
H. Sleeping Room ...............................4
I. California - Prop65..............................4
2 Getting Started
A. Design, Installation & Location Considerations .......5
B. Tools And Supplies Needed ......................6
C. Inspect Appliance and Components ...............6
D. Removal of Appliance from Shipping Materials .......6
E. Install Checklist ...............................7
3 Dimensions and Clearances
A. Appliance Dimensions ..........................8
B. Clearances to Combustibles (US & Canada)........10
C. Hearth Pad Requirements (UL & ULC) ............11
D. Alcove .....................................12
4 Vent Information
5 Venting Systems
A. Through The Wall.............................17
B. Vertical into Existing Class A Chimney.............18
C. Through The Wall & Vertical - Exterior.............18
D. Vertical - Interior - Typical Installation .............18
E. Masonry ....................................19
F. Alternate Masonry.............................19
6 Appliance Set-Up
A. Leg Leveling System ..........................20
B. Outside Air Kit Instructions .....................20
C. Top Vent Adapter Installation ....................21
D. Rear Vent & Rear Vent to Top Vent Adapter ........21
E. Optional Log Set Placement Instructions ..........22
F. Installation of User Interface .....................23
G. Power to Appliance and User Interface ............23
H. Location & Mounting User Interface...............23
7 Mobile Home Installation ......................24
8 Reference Materials
A. Service and Maintenance Log ...................25
B. Accessories List ..............................27
A. Venting Termination Minimum Requirements........13
B. Avoiding Smoke and Odors .....................14
C. Negative Pressure ............................15
D. Draft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
E. Chimney and Exhaust Connection................15
F. Equivalent Feet of Pipe.........................16
G. Pipe Selection Chart ..........................16
Quadra-Fire is a registered trademark of Hearth & Home Technologies.
2 01/217080-165J
= Contains updated information
TREKKER

1 Important Safety Information

A. Appliance Certication B. BTU & E󰀩ciency Specications
Model: Trekker Pellet Stove
Safety
Laboratory:
Report No: 061-S-83-2
Type:
Standard:
FCC:
OMNI Test Laboratories, Inc.
Solid Fuel Room Heater, Pellet Fuel
Burning Type
ASTM E1509-12, ULC S627-00 and (UM) 84-HUD, Mobile Home Approved.
Complies with Part 15 of FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired operation.
Emissions Report
Number:
EPA Certication
Number:
EPA Certied Emissions: 0.74 grams per hour
*LHV Tested E󰀩ciency: 83.2%
**HHV Tested E󰀩ciency: 77.9%
***EPA BTU Output: 12,700 to 39,400 / hr.
****BTU Input: 16,400 to 50,800 / hr.
Vent Size: 3” or 4” Type “L” or “PL”
Hopper Capacity: 80 lbs.
Fuel: Premium Wood Pellets
* Weighted average LHV (Low Heating Value) e󰀩ciency using data collected during EPA emissions tests.
**Weighted average HHV (High Heating Value) e󰀩ciency using data collected during EPA emissions tests.
*** A range of BTU outputs calculated using HHV
e󰀩ciency and the burn rates from the EPA tests.
**** Based on the maximum feed rate per hour multiplied
by approximately 8600 BTU’s which is the average BTU’s
from a pound of pellets.
‡ Grade of pellet fuel as certied by Pellet Fuels Institute
(PFI), ENPlus or CANplus.
0061PS094E
Number: 98-17
The Trekker is Certied to
comply with 2020 particulate
emission standards.
This pellet appliance needs periodic inspection and repair for proper operation. It is against federal regulations to operate this pellet appliance in a manner inconsistent with operating instructions in this manual.
NOTICE: This installation must conform with local codes. In the absence of local codes you must comply with the
ASTM E1509-04, ULC S627-00, (UM) 84-HUD and ULC/ORD-C-1482.
3 01/217080-165J
TREKKER
C. Glass Specications
This appliance is equipped with 5mm ceramic glass. Replace glass only with 5mm ceramic glass. Please
contact your dealer for replacement glass.

D. Electrical Rating

115 VAC, 60 Hz, Start 2.9 Amps, Run 2.45 Amps

E. Mobile Home Approved

This appliance is approved for mobile home installations when not installed in a sleeping room and when an outside combustion air inlet is provided.
The structural integrity of the mobile home oor, ceiling, and walls must be maintained.
The appliance must be properly grounded to the frame
of the mobile home and use only Listed pellet vent Class “L” or “PL” connector pipe.
Outside Air Kit, part OAK-3 must be installed in a mobile home installation.

F. Non-Combustible Materials

Material which will not ignite and burn, composed of any combination of the following:
- Steel
- Plaster
- Brick
- Iron
- Concrete
- Tile
- Glass
- Slate
Materials reported as passing ASTM E 136, Standard Test
Method for Behavior of Metals, in a Vertical Tube Furnace of 750° C.

G. Combustible Materials

Material made of/or surfaced with any of the following materials:
- Wood
- Compressed Paper
- Plant Fibers
- Plastic
- Plywood/OSB
- Sheet Rock (drywall) Any material that can ignite and burn: Flame proofed or not, plastered or non-plastered.

I. California - Prop65

WARNING
This product and the fuels used to operate this product (wood), and
the products of combustion of such fuels, can expose you to
chemicals including carbon black, which is known to the State of
California to cause cancer, and carbon monoxide, which is known to
the State of California to cause birth defects or other reproductive
harm. For more information go to: WWW.P65Warnings.ca.gov
WARNING
Fire Risk
Hearth & Home Technologies disclaims any
responsibility for, and the warranty will be voided by, the following actions:
Installation and use of any damaged appliance.
Modication of the appliance.
Installation other than as instructed by Hearth & Home Technologies.
Installation and/or use of any component part not
approved by Hearth & Home Technologies.
Operating appliance without fully assembling all components.
Operating appliance without legs attached (if
supplied with appliance).
Do NOT Over re - If appliance or chimney connector glows, you are over ring.
Any such action that may cause a re hazard.
Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.
For assistance or additional information, consult a qualied
installer, service agency or your dealer.
NOTE: Hearth & Home Technologies, manufacturer
of this appliance, reserves the right to alter
its products, their specications and/or price
without notice.

H. Sleeping Room

When installed in a sleeping room it is recommended that 3ft of vertical be installed prior to horizontally exiting the
room and a smoke/CO alarm be installed in the bedroom. The size of the room must be at least 50ft³ per 1,000 Btu/hr
stove input, if the stove exceeds the room size, out air must be installed.
4 01/217080-165J
TREKKER
Recommended
Location
Marginal Location
Location
Not
Recommended
Recommended
Location
Location NOT
Recommended
Multi-level Roofs
Windward
Leeward
Outside Air Kit Termination Cap

2 Getting Started

Install Guide

A. Design, Installation & Location Considerations

NOTICE: Check building codes prior to installation.
1. Appliance Location
Installation MUST comply with local, regional, state and national codes and regulations.
Consult insurance carrier, local building inspector,
re o󰀩cials or authorities having jurisdiction over
restrictions, installation inspection and permits.
It is a good idea to plan your installation on paper, using
exact measurements for clearances and oor protection, before actually beginning the installation. Location of the appliance and chimney will a󰀨ect performance.
Consideration must be given to:
Safety, convenience, tra󰀩c ow
Placement of the chimney and chimney connector and
to minimize the use of chimney o󰀨sets.
Place the appliance where there will be a clear passage for a Listed chimney through the ceiling and roof (vertical) or through exterior wall (horizontal).
Installing the required outside air kit will a󰀨ect the location of the vent termination.
When locating vent and venting termination, the ideal location is to vent above roof line when possible. This
minimizes the a󰀨ects of wind loading.
Since pellet exhaust can contain ash, soot or sparks, you
must consider the location of:
Windows
Air Intakes
Air Conditioner
Overhang, so󰀩ts, porch roofs, adjacent walls
Landscaping, vegetation
Horizontal or vertical vent termination
2. Floor Support
The supporting oor under the appliance must be able to
handle the weight of the appliance, fuel load and the weight of the chimney.
Ensure that your oor will support these weights prior to installation. Add su󰀩cient additional support to meet this
weight requirement prior to installation. The weight of the
appliance is 426 lbs with a full load of fuel the max weight
is 473 lbs.
WARNING
Risk of Fire.
Damaged parts could impair safe operation. Do NOT
install damaged, incomplete or substitute components.
Figure 5.1
5 01/217080-165J
TREKKER
WARNING
Risk of Fire!
Damaged parts could impair safe operation.
Do NOT install damaged, incomplete or substitute components.
WARNING
Hearth & Home Technologies disclaims any responsibility for, and the warranty will be voided by, the following actions:
Installation and use of any damaged appliance.
Modication of the appliance.
Installation other than as instructed by Hearth & Home Technologies.
Installation and/or use of any component part not
approved by Hearth & Home Technologies.
Operating appliance without fully assembling all components.
Operating appliance without legs attached (if
supplied with appliance).
Do NOT Over re
Or any such action that may cause a re hazard.

C. Inspect Appliance and Components

Open the appliance and remove all the parts and articles packed inside the Component Pack. Inspect all
the parts and glass for shipping damage.
Report to your dealer any parts damaged in shipment.
All labels have been removed from the glass door.
Plated surfaces have been wiped clean with a soft cloth, if applicable.
Read all the instructions before starting the installation. Follow these instructions carefully during the installation to ensure maximum safety
and benet.
Follow pipe manufacturer instructions for installation and air clearance requirements.
D. Removal of Appliance from Shipping
Materials
1. Remove box and 2x4 structural boards being careful not to damage product.
2. Using 3/8 socket or wrench remove both front bolts
from pallet mount brackets. Front pallet mount brackets
will slide outwards away from appliance (Figure 6.1).
3. Using 3/8 socket or wrench remove bolts from side
pallet mount brackets. Side pallet mount brackets will
slide downwards from appliance (Figure 6.2).
4. Carefully pull appliance o󰀨 of pallet and put in
desired location following Hearth Pad on page 11 and
Clearance to Combustibles on page 10.

B. Tools And Supplies Needed

Tools and building supplies normally required for installation, unless installing into an existing
masonry replace:
Reciprocating Saw
Channel Locks
Hammer
Phillips Screwdriver
Tape Measure
Plumb Line
1/4” Self-Tapping Screws
Framing Material
Hi-temp Caulking Material
Gloves
Safety Glasses
Framing Square
Electric Drill & Bits (1/4”)
Level
May also need:
Vent Support Straps
Venting Paint
Figure 6.1
Figure 6.2
6 01/217080-165J
TREKKER

E. Install Checklist

This standard work checklist is to be used by the installer in conjunction with, not instead of, the instructions contained in this installation manual.
ATTENTION INSTALLER:
Follow this Standard Work Checklist
Customer: Date Installed: Lot/Address: Location of Appliance: Installer: Dealer/Distributor Phone Number: Serial Number: Model Name:
WARNING! Risk of Fire or Explosion! Failure to install appliance to these instructions can lead to a fire or explosion.
Appliance Install
Verified clearance to combustibles. Appliance is leveled and connector is secured to appliance. Hearth extension size/height decided. Outside air kit installed. Floor protection requirements have been met. If appliance is connected to a masonry chimney, it should be cleaned and
inspected by a professional. If installed to a factory built metal chimney, the chimney must be installed according to the manufacturer’s instructions and clearances.
Venting/Chimney
Chimney configuration complies with diagrams. Chimney installed, locked and secured in place with proper clearance. Chimney meets recommended height requirements (5 feet minimum vertical). Roof flashing installed and sealed. Terminations installed and sealed.
__________________________________________________________________________
______________________________________________________________________
_______________________________________________________________________
________________________________________________________________
___________________________________________________________________________
________________________________________________________
______________________________________________________________________
_______________________________________________________________________
YES IF NO, WHY?
Electrical
120 VAC unswitched power provided to the appliance. Check outlet with multi-meter for proper polarity and voltage (115-120 VAC).
Record voltage reading: _____________
Clearances
Verified all clearances meet installation manual requirements. Mantels and wall projections comply with installation manual requirements. Floor protection and heart extensions installed per manual requirements.
Appliance Setup
All protective materials removed. All labels have been removed from the door. All packaging materials are removed from inside/under appliance. Manual bag and all of its contents are removed from inside/under the appliance
and given to the party responsible for use and operation. Started appliance and verified that all motors and blowers operate as they should.
Checked draft using a Manometer. Record readings: ______________________ Checked vacuum using a Manometer. Record readings: ____________________
Hearth & Home Technologies recommends the following:
Photographing the installation and copying this checklist for your file. That this checklist remain visible at all times on the appliance until the installation is complete.
Comments: Further description of the issues, who is responsible (Installer/Builder/Other Trades, ets.) and corrective action needed: Comments communicated to party responsible
__________________________ by ______________________ on ____________
(Builder/Gen. Contractor) (Installer) (Date)
7 01/217080-165J
TREKKER
3-3/4 in (97mm)
4-1/8 in
(104mm)
6-1/8 in
(155mm)
6-1/8 in
(155mm)
14 in (357mm)
qq
5-13/16 in (147mm)
2-9/16 in
(65mm)
3-13/16 in (97mm)
14-1/16 in
(357mm)
3-3/4 in (97mm)
3-3/4 in (97mm)
4-1/8 in
(104mm)
4-1/8 in
(104mm)
8-1/4 in
(208mm)
8-1/4 in
(208mm)
10-3/8 in (264mm)
10-3/8 in (264mm)
28-1/8 in (714mm)
32 in
(813mm)
11-3/4 in (297mm)
18-1/2 in (469mm)
28-7/16 in (722mm)

3 Dimensions and Clearances

A. Appliance Dimensions

3-5/8 in
3-5/8 in (93mm)
(93mm)
qq
Figure 8.1 - Top View Figure 8.4 - Top View with Top Vent Adapter (TPVNT-3) and
10-3/8 in
10-3/8 in (264mm)
(264mm)
O󰀨set Adapter (812-3570).
Figure 8.2 - Top View with Top Vent Adapter (TPVNT-3) and
O󰀨set Adapter (811-0720).
Figure 8.3 - Front View
Figure 8.5 - Top View with Top Vent Adapter (TPVNT-6) and
O󰀨set Adapter (811-0720).
8 01/217080-165J
TREKKER
31-1/16 in
(788mm)
29-3/16 in
(741mm)
25-3/8 in (646mm)
25-3/8 in (646mm)
27-1/8 in
(688mm)
27-1/8 in (688mm)
29 in
(738mm)
29 in
(738mm)
30-5/8 in (779mm)
30-5/8 in (779mm)
28-3/4 in (730mm)
26-7/8 in (683mm)
19-9/16 in (497mm)
20 in (508mm)
Figure 9.1 -Side View
Figure 9.2 - Side View with Top Vent Adapter (TPVNT-3) and
O󰀨set Adapter (812-3570).
Figure 9.4 - Side View with Top Vent Adapter (TPVNT-6) and
O󰀨set Adapter (811-0720).
Figure 9.3 - Side View with Top Vent Adapter (TPVNT-3) and
O󰀨set Adapter (811-0720).
9 01/217080-165J
Loading...