INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
NOTICE: DO NOT discard this manual!
Models:
LCOR-DV36IN
RCOR-DV36IN
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
• DO NOT store or use gasoline or other am-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Leave the building immediately.
- Immediately call your gas supplier from
a neighbor’s phone. Follow the gas supplier’s instructions.
- If you cannot reach your gas supplier, call
the re department.
• Installation and service must be performed
by a qualied installer, service agency, or the
gas supplier.
This appliance may be installed as an OEM
installation in manufactured home (USA
only) or mobile home and must be installed
in accordance with the manufacturer’s
instructions and the Manufactured Home
Construction and Safety Standard, Title 24
CFR, Part 3280 in the United States, or the
Standard for Installation in Mobile Homes,
CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s)
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certied kit is used.
Hearth & Home Technologies • LCOR-DV36IN, RCOR-DV36IN Installation Manual • 2486-980 Rev. F • 7/18
DANGER
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
A barrier designed to reduce the risk of
burns from the hot viewing glass is provided
with this appliance and shall be installed for
the protection of children and other at-risk
individuals.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas tter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
1
Safety Alert Key:
• DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury.
• WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury.
• CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
• NOTICE: Used to address practices not related to personal injury.
Table of Contents
Installation Standard Work Checklist ....................3
1 Product Specic and Important Safety Information
A. Appliance Certication ............................4
B. Glass Specications ..............................4
C. BTU Specications ...............................4
D. High Altitude Installations ..........................4
F. Install Fixed Glass Assembly ......................58
12 Reference Materials
A. Vent Components Diagrams ......................59
B. Accessories ................................... 70
6 Appliance Preparation
A. Vent Collar Preparation ..........................32
B. Securing and Leveling the Appliance ................34
C. Non-Combustible Material Installation ............... 35
2
Hearth & Home Technologies • LCOR-DV36IN, RCOR-DV36IN Installation Manual • 2486-980 Rev. F • 7/18
= Contains updated information.
Installation Standard Work Checklist
ATTENTION INSTALLER:
Follow this Standard Work Checklist
This standard work checklist is to be used by the installer in conjunction with, not instead of, the instructions contained in this
installation manual.
Customer:
Lot/Address:
Model (circle one): LCOR-DV36IN
RCOR-DV36IN
WARNING! Risk of Fire or Explosion! Failure to install appliance according to these instructions could
lead to a re or explosion.
Appliance Install YES IF NO, WHY?
Veri ed that the chase is insulated and sealed. (Pg. 12) ___________________________
Required non-combustible board is installed. (Pg. 35) ___________________________
Veri ed clearances to combustibles. (Pg. 10-12) ___________________________
Fireplace is leveled and secured. (Pg. 34) ___________________________
Venting/Chimney Section 7 (Pg 36-42)
Venting con guration complies to vent diagrams. ___________________________
Venting installed, locked and secured in place with proper clearance. ___________________________
Firestops installed. ___________________________
Attic insulation shield installed. ___________________________
Exterior wall/Roof ashing installed and sealed. ___________________________
Terminations installed and sealed. ___________________________
Date Installed:
Location of Fireplace:
Installer:
Dealer/Distributor Phone #
Serial #:
Electrical Section 8 (Pg 43-47)
Unswitched power (110-120 VAC) provided to the appliance. ___________________________
Switch wires properly installed. ___________________________
Gas Section 9 (Pg 48-49)
Proper appliance for fuel type. ___________________________
Was a conversion performed? ___________________________
Leak check performed and inlet pressure veri ed. ___________________________
Veri ed proper air shutter setting for installation type. ___________________________
Finishing Section 10 (Pg 50-51)
Combustible materials not installed in non-combustible areas. ___________________________
Veri ed all clearances meet installation manual requirements. ___________________________
Mantels and wall projections comply with installation manual requirements. ___________________________
Appliance Setup Section 11 (Pg 52-58)
All packaging and protective materials removed (inside & outside of appliance). ___________________________
Refractories, logs, media and embers installed correctly. ___________________________
Glass assembly installed and secured. ___________________________
Accessories installed properly. ___________________________
Mesh, doors, or decorative front properly installed. ___________________________
Manual bag and all of its contents are removed from inside/under
the appliance and given to party responsible for use and operation. ___________________________
Started appliance and veri ed no gas leaks exist. ___________________________
Hearth & Home Technologies recommends the following:
• Photographing the installation and copying this checklist for your le.
• That this checklist remain visible at all times on the appliance until the installation is complete.
Comments: Further description of the issues, who is responsible (Installer/ Builder/ Other Trades, etc) and corrective
action needed _____________________________________________________________________________________
_________________________________________________________________________________________________
_________________________________________________________________________________________________
Comments Communicated to party responsible ____________________ by ______________________on ___________
(Builder / Gen. Contractor/) (Installer) (Date)
= Contains updated information.
Hearth & Home Technologies • LCOR-DV36IN, RCOR-DV36IN Installation Manual • 2486-980 Rev. F • 7/18
2486-982 2/17
3
1
Product Specic and Important Safety Information
A. Appliance Certication
MODELS: LCOR-DV36IN, RCOR-DV36IN
LABORATORY: Underwriters Laboratories, Inc. (UL)
TYPE: Direct Vent Heater
STANDARD: ANSI Z21.88-2017 • CSA 2.33-2017
This product is listed to ANSI standards for “Vented Gas
Fireplace Heaters” and applicable sections of “Gas Burn-
ing Heating Appliances for Manufactured Homes and
Recreational Vehicles”, and “Gas Fired Appliances for
Use at High Altitudes”.
NOTICE: This installation must conform with local codes.
In the absence of local codes you must comply with the
National Fuel Gas Code, ANSI Z223.1-latest edition in
the U.S.A. and the CAN/CGA B149 Installation Codes in
Canada.
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemen-
tal room heat or as a decorative appliance. It should not be
factored as primary heat in residential heating calculations.
B. Glass Specications
Hearth & Home Technologies appliances manufactured
with tempered glass may be installed in hazardous locations such as bathtub enclosures as dened by the
Consumer Product Safety Commission (CPSC). The
tempered glass has been tested and certied to the re-
quirements of ANSI Z97.1 and CPSC 16 CFR 1202
(Safety Glazing Certication Council SGCC# 1595 and
1597. Architectural Testing, Inc. Reports 02-31919.01
and 02-31917.01).
This statement is in compliance with CPSC 16 CFR Sec-
tion 1201.5 “Certication and labeling requirements”
which refers to 15 U.S. Code (USC) 2063 stating “…Such
certicate shall accompany the product or shall otherwise
be furnished to any distributor or retailer to whom the
product is delivered.”
Some local building codes require the use of tempered
glass with permanent marking in such locations. Glass
meeting this requirement is available from the factory.
Please contact your dealer or distributor to order.
C. BTU Specications
(U.S. or Canada)
LCOR-DV36IN
(NG)
LCOR-DV36IN
(Propane)
RCOR-DV36IN
(NG)
RCOR-DV36IN
(Propane)
4
Models
(0-2000 FT)
(0-2000 FT)
(0-2000 FT)
(0-2000 FT)
Hearth & Home Technologies • LCOR-DV36IN, RCOR-DV36IN Installation Manual • 2486-980 Rev. F • 7/18
Maximum
Input
BTU/h
38,00021,00032
35,50020,00050
38,00021,00032
35,50020,00050
Minimum
Input BTU/h
Orice
Size
(DMS)
D. High Altitude Installations
NOTICE: If the heating value of the gas has been reduced,
these rules do not apply. Check with your local gas utility
or authorities having jurisdiction.
When installing above 2000 feet elevation:
• In the USA: Reduce input rate 4% for each 1000 feet
above 2000 feet.
• In CANADA: Input ratings are certied without a reduction
of input rate for elevations up to 4500 feet (1370 m)
above sea level. Please consult provincial and/or
local authorities having jurisdiction for installations at
elevations above 4500 feet (1370 m).
Check with your local gas utility to determine proper
orice size.
E. Non-Combustible Materials Specication
Material which will not ignite and burn. Such materials are
those consisting entirely of steel, iron, brick, tile, concrete,
slate, glass or plasters, or any combination thereof.
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in
a Vertical Tube Furnace at 750 ºC shall be considered
non-combustible materials.
F. Combustible Materials Specication
Materials made of or surfaced with wood, compressed pa-
per, plant bers, plastics, or other material that can ignite
and burn, whether ame proofed or not, or plastered or
unplastered shall be considered combustible materials.
G. Electrical Codes
NOTICE: This appliance must be electrically wired
and grounded in accordance with local codes or, in the
absence of local codes, with National Electric Code
ANSI/NFPA 70-latest edition or the Canadian Electric
Code CSA C22.1.
• A 110-120 VAC circuit for this product must be protected with ground-fault circuit-interrupter protection,
in compliance with the applicable electrical codes,
when it is installed in locations such as in bathrooms
or near sinks.
H. California
WARNING: This product and the fuels used to
operate this product (liquid propane or natural
gas), and the products of combustion of such fuels, can
expose you to chemicals including benzene, which is
known to the State of California to cause cancer and
reproductive harm. For more information go to: www.
P65Warnings.ca.gov.
Note: The following requirements reference various
Massachusetts and national codes not contained in this
document.
I. Requirements for the Commonwealth of
Massachusetts
For all side wall horizontally vented gas fueled equipment
installed in every dwelling, building or structure used in
whole or in part for residential purposes, including those
owned or operated by the Commonwealth and where the
side wall exhaust vent termination is less than seven (7)
feet above nished grade in the area of the venting, including but not limited to decks and porches, the following
requirements shall be satised:
Installation of Carbon Monoxide Detectors
At the time of installation of the side wall horizontal vented
gas fueled equipment, the installing plumber or gas tter
shall observe that a hard wired carbon monoxide detector
with an alarm and battery back-up is installed on the oor
level where the gas equipment is to be installed. In addition, the installing plumber or gas tter shall observe that
a battery operated or hard wired carbon monoxide detec-
tor with an alarm is installed on each additional level of
the dwelling, building or structure served by the side wall
horizontal vented gas fueled equipment. It shall be the
responsibility of the property owner to secure the services
of qualied licensed professionals for the installation of
hard wired carbon monoxide detectors.
In the event that the side wall horizontally vented gas fu-
eled equipment is installed in a crawl space or an attic,
the hard wired carbon monoxide detector with alarm and
battery back-up may be installed on the next adjacent
oor level.
In the event that the requirements of this subdivision can
not be met at the time of completion of installation, the
owner shall have a period of thirty (30) days to comply
with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon
monoxide detector with an alarm shall be installed.
Inspection
The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the
installation unless, upon inspection, the inspector ob-
serves carbon monoxide detectors and signage installed
in accordance with the provisions of 248 CMR 5.08(2)(a)1
through 4.
Exemptions
The following equipment is exempt from 248 CMR 5.08(2)
(a)1 through 4:
• The equipment listed in Chapter 10 entitled “Equipment
Not Required To Be Vented” in the most current edition
of NFPA 54 as adopted by the Board; and
• Product Approved side wall horizontally vented gas fu-
eled equipment installed in a room or structure separate
from the dwelling, building or structure used in whole or
in part for residential purposes.
MANUFACTURER REQUIREMENTS
Gas Equipment Venting System Provided
When the manufacturer of Product Approved side wall
horizontally vented gas equipment provides a venting
system design or venting system components with the
equipment, the instructions provided by the manufacturer
for installation of the equipment and the venting system
shall include:
• Detailed instructions for the installation of the venting
system design or the venting system components; and
• A complete parts list for the venting system design or
venting system.
Gas Equipment Venting System NOT Provided
When the manufacturer of a Product Approved side wall
horizontally vented gas fueled equipment does not provide the parts for venting the ue gases, but identies
“special venting systems”, the following requirements
shall be satised by the manufacturer:
Approved Carbon Monoxide Detectors
Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA
720 and be ANSI/UL 2034 listed and IAS certied.
Signage
A metal or plastic identication plate shall be permanently mounted to the exterior of the building at a minimum
height of eight (8) feet above grade directly in line with the
exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read,
in print size no less than one-half (1/2) in. in size, “GAS
VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”.
Hearth & Home Technologies • LCOR-DV36IN, RCOR-DV36IN Installation Manual • 2486-980 Rev. F • 7/18
• The referenced “special venting system” instructions
shall be included with the appliance or equipment installation instructions; and
• The “special venting systems” shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation
instructions.
A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equip-
ment, all venting instructions, all parts lists for venting
instructions, and/or all venting design instructions shall
remain with the appliance or equipment at the completion
of the installation.
See Gas Connection section for additional Commonwealth of Massachusetts requirements.
5
2
Getting Started
A. Design and Installation Considerations
Hearth & Home Technologies direct vent gas appliances
are designed to operate with all combustion air siphoned
from outside of the building and all exhaust gases expelled to the outside. No additional outside air source is
required.
Installation MUST comply with local, regional, state and
national codes and regulations. Consult insurance carrier,
local building inspector, re ofcials or authorities having
jurisdiction over restrictions, installation inspection and
permits.
Before installing, determine the following:
• Where the appliance is to be installed.
• The vent system conguration to be used.
• Gas supply piping requirements.
• Electrical wiring requirements.
• Framing and nishing details.
• Whether optional accessories—devices such as a fan,
wall switch, or remote control—are desired.
Installation and service of this appliance should be performed by
qualied personnel. Hearth & Home Technologies recommends
HHT Factory Trained or NFI certied professionals.
B. Good Faith Wall Surface/TV Guidelines
TO CEILING
90°F
90°F
FIREPL ACE
OPENIN G
110°F
120°F
18 in.
130°F
12 in.
6 in.
MEASUR EMENTS FROM
TOP EDGE O F THE OPENING
APPLIA NCE FRONT
Figure 2.1 Good Faith Wall Surface Temperatures Above Appliance
NOTICE: Temperatures listed above are taken with a
temperature measuring probe as prescribed by the test
standard used for appliance certication. Temperatures
on walls or mantels taken with an infrared thermometer
may yield increased temperatures of up to 30 degrees or
more depending on the thermometer settings and material
characteristics being measured.
100°F
24 in.
95°F
95°F
48 in.
42 in.
36 in.
30 in.
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. For
assistance or additional information, consult a qualied
service technician, service agency or your dealer.
C. Tools and Supplies Needed
Before beginning the installation be sure that the following
tools and building supplies are available.
Tape measure Framing material
Pliers Hammer
Phillips screwdriver Manometer
Gloves Framing square
Voltmeter Electric drill and bits (1/4 in.)
Plumb line Safety glasses
Level Reciprocating saw
Flat blade screwdriver
Non-corrosive leak check solution
1/2 - 3/4 in. length, #6 or #8 Self-drilling screws
Caulking material (300 ºF minimum continuous exposure
rating)
One 1/4 in. female connection (for optional fan).
6
Hearth & Home Technologies • LCOR-DV36IN, RCOR-DV36IN Installation Manual • 2486-980 Rev. F • 7/18
D. Inspect Appliance and Components
• Carefully remove the appliance and components from
the packaging.
• The vent system components and decorative doors and
fronts may be shipped in separate packages.
• If packaged separately, the log set and appliance grate
must be installed.
• Report to your dealer any parts damaged in shipment,
particularly the condition of the glass.
• Read all of the instructions before starting the installation. Follow these instructions carefully during the
installation to ensure maximum safety and benet.
WARNING! Risk of Fire or Explosion! Damaged parts
could impair safe operation. DO NOT install damaged, incomplete or substitute components. Keep appliance dry.
WARNING! Risk of Fire! DO NOT remove refractory.
Appliance could overheat!
DO NOT REMOVE REFRACTORY
Hearth & Home Technologies disclaims any responsibility for,
and the warranty will be voided by, the following actions:
• Installation and use of any damaged appliance or vent
system component.
• Modication of the appliance or vent system.
• Installation other than as instructed by Hearth & Home
Technologies.
• Improper positioning of the gas logs or the glass door.
• Installation and/or use of any component part not approved
by Hearth & Home Technologies.
Any such action may cause a re hazard.
WARNING! Risk of Fire, Explosion or Electric Shock!
DO NOT use this appliance if any part has been under
water. Call a qualied service technician to inspect the
appliance and to replace any part of the control system
and/or gas control which has been under water.
Figure 2.2 Do Not Remove Refractory
WARNING! Risk of Fire! DO NOT remove standoff.
Appliance could overheat!
DO NOT REMOVE STANDOFF
Figure 2.3 Do Not Remove Standoff
Hearth & Home Technologies • LCOR-DV36IN, RCOR-DV36IN Installation Manual • 2486-980 Rev. F • 7/18
7
3
Framing and Clearances
A. Appliance/Decorative Front Dimension Diagrams
Dimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to Section 5.
Hearth & Home Technologies • LCOR-DV36IN, RCOR-DV36IN Installation Manual • 2486-980 Rev. F • 7/18
DECORATIVE FRONT - COR-36BK
(Model: LCOR-DV36IN/RCOR-DV36IN)
A
B
C
D
DECORATIVE FRONT - COREP-36BK
(Model: LCOR-DV36IN/RCOR-DV36IN)
E
F
G
Location
A32-3/8822
B22-9/16573
C36-1/16916
D1-3/835
E6-7/8175
F32-1/16814
G33-7/16849
COR-36BK
InchesMillimeters
F
B
A
G
E
C
D
Figure 3.2 Decorative Front Dimensions - COR-36BK and COREP-36BK
Hearth & Home Technologies • LCOR-DV36IN, RCOR-DV36IN Installation Manual • 2486-980 Rev. F • 7/18
Location
A20-1/8511
B22-1/16560
C25-5/16643
D1-3/835
E6-7/8175
F32-1/16814
G33-7/16849
COREP-36BK
InchesMillimeters
9
B. Clearances to Combustibles
When selecting a location for the appliance it is important
to consider the required clearances to walls (see Figure
3.3 ).
WARNING! Risk of Fire or Burns! Provide adequate
clearance around air openings and for service access.
Due to high temperatures, the appliance should be lo-
cated out of trafc and away from furniture and draperies.
NOTICE: Illustrations reect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
NOTICE: This See-Through appliance is NOT designed
or approved for an indoor/outdoor application.
36 in.
914 mm
LCOR
36 in.
914 mm
Figure 3.3 Appliance Locations
10
Hearth & Home Technologies • LCOR-DV36IN, RCOR-DV36IN Installation Manual • 2486-980 Rev. F • 7/18
36 in.
914 mm
36 in.
914 mm
RCOR
NOTICE: Install appliance on hard metal or wood surfaces
extending full width and depth. DO NOT install directly
on carpeting, vinyl, tile or any combustible material other
than wood.
WARNING! Risk of Fire! Maintain specied air space
clearances to appliance and vent pipe:
• Insulation and other materials must be secured to prevent
accidental contact.
• The chase must be properly blocked to prevent blown
insulation or other combustibles from entering and
making contact with replace or chimney.
• Failure to maintain airspace may cause overheating and
a re.
NOTICE: Illustrations reect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
A
I
H
I
E
C
B
D
G
F
ABCDEFGHI
LCOR-DV36IN
RCOR-DV36IN
Inches
Millimeters
DVP Pipe SLP Pipe
Rough
Opening
(Width)
10938-1/8244034-1/800 1/236
25422996861010168670013914
Rough
Opening
(Width)
Rough
Opening
(Height)
DVP Pipe*
Rough
Opening
(Depth)
Rough
Opening
(Width)
Adjust framing dimensions for interior sheathing (such as sheetrock)
Figure 3.4 Clearances to Combustibles - LCOR-DV36IN, RCOR-DV36IN
Hearth & Home Technologies • LCOR-DV36IN, RCOR-DV36IN Installation Manual • 2486-980 Rev. F • 7/18
Clearance
to Ceiling
Combustible
Floor
Combustible
Flooring
Ends of
Appliance
Sides of
Appliance
11
FACTORY-INSTALLED
NON-COMBUSTIBLE BOARD
3-7/8 in.
= AIR SPACE REQUIRED
Figure 3.5 Non-Combustible Zone
C. Constructing the Appliance Chase
A chase is a vertical box-like structure built to enclose the
gas appliance and/or its vent system. In cooler climates
the vent should be enclosed inside the chase.
NOTICE: Treatment of ceiling restops and wall shield
restops and construction of the chase may vary with the
type of building. These instructions are not substitutes
for the requirements of local building codes. Therefore,
you MUST check local building codes to determine the
requirements to these steps.
NOTICE: When installing a sprinkler head in a replace
chase, it is recommended to use a sprinkler head with a
sprinkler activation temperature classied as Extra High.
Keep sprinkler head away from vent and chimney.
Chases should be constructed in the manner of all outside walls of the home to prevent cold air drafting prob-
lems. The chase should not break the outside building
envelope in any manner.
Walls, ceiling, base plate and cantilever oor of the chase
should be insulated. Vapor and air inltration barriers
should be installed in the chase as per regional codes for
the rest of the home. Additionally, in regions where cold
air inltration may be an issue, the inside surfaces may be
sheetrocked and taped (or an equivalent method may be
used) to achieve maximum air tightness.
To further prevent drafts, the wall shield and ceiling restops should be caulked with caulk with a minimum of
300 ºF continuous exposure rating to seal gaps. Gas
line holes and other openings should be caulked with
caulk with a minimum of 300 ºF continuous exposure rating
or stuffed with unfaced insulation. If the appliance is being
installed on a cement surface, a layer of plywood may be
placed underneath to prevent conducting cold up into the
room.
12
NOTICE: Install appliance on hard metal or wood surfaces
extending full width and depth. DO NOT install directly
on carpeting, vinyl, tile or any combustible material other
than wood.
WARNING! Risk of Fire! Maintain specied air space
clearances to appliance and vent pipe:
• Insulation and other materials must be secured to prevent
accidental contact.
• The chase must be properly blocked to prevent blown
insulation or other combustibles from entering and
making contact with replace or chimney.
• Failure to maintain airspace may cause overheating and
a re.
Hearth & Home Technologies • LCOR-DV36IN, RCOR-DV36IN Installation Manual • 2486-980 Rev. F • 7/18
4
AB
Termination Location and Vent Information
A. Vent Termination Minimum Clearances
Fire Risk.
Maintain vent clearance to combustibles as
specied.
• DO NOT pack air space with insulation or other
Failure to keep insulation or other materials away
from vent pipe could cause overheating and re.
2 FT.
MIN.
GAS DIRECT VENT
TERMINATION CAP
materials.
WARNING
HORIZONTAL
OVERHANG
20 INCHES MIN.
LOWEST
DISCHARGE
OPENING
H (MIN.) - MINIMUM HEIGHT FROM ROOF
TO LOWEST DISCHARGE OPENING
X
12
ROOF PITCH
IS X/ 12
VERTICAL
WALL
6 in. (minimum) up to 20 in.
152 mm/508 mm
20 in. and over0 in. minimum
18 in. minimum
457 mm
Gas, Wood or Fuel Oil
Termination Cap
B
A *
Gas
Termination
Cap **
If using decorative cap cover(s), this distance may need to be
*
increased. Refer to the installation instructions supplied with the
decorative cap cover.
In a staggered installation with both gas and wood or fuel oil
**
terminations, the wood or fuel oil termination cap must be
higher than the gas termination cap.
Roof Pitch H (Min.) Ft.
Flat to 6/12...........................................................1.0*
Over 6/12 to 7/12 .................................................1.25*
Over 7/12 to 8/12 .................................................1.5*
Over 8/12 to 9/12 .................................................2.0*
Over 9/12 to 10/12 ...............................................2.5*
Over 10/12 to 11/12 .............................................3.25
Over 11/12 to 12/12 .............................................4.0
Over 12/12 to 14/12 .............................................5.0
Over 14/12 to 16/12 .............................................6.0
Over 16/12 to 18/12 .............................................7.0
Over 18/12 to 20/12 .............................................7.5
Over 20/12 to 21/12 .............................................8.0
* H minimum may vary depending on regional snowfall.
Refer to local codes.
Figure 4.1 Minimum Height From Roof to Lowest Discharge
Opening
Figure 4.2 Staggered Termination Caps
Hearth & Home Technologies • LCOR-DV36IN, RCOR-DV36IN Installation Manual • 2486-980 Rev. F • 7/18
13
B. Chimney Diagram
C
V
B
J
V
V
= VENT TERMINAL
X
= AIR SUPPLY INLET
B
D
V
V
V
A
= AREA WHERE TERMINAL IS NOT PERMITTED
A = 12 inches.................clearances above grade, veranda,
porch, deck or balcony
B = 12 inches.................clearance to window or door that may
be opened, or to permanently closed
window
C = 18inches.................clearance below unventilated soft
30 inches .................clearance below vinyl soffits and
electrical service
D = 6 inches...................clearance to outside corner
E = 6 inches...................clearance to inside corner
F = 3 ft. (Canada) ..........not to be installed above a gas me-
ter/regulator assembly within 3 feet
horizontally from the center-line of the
regulator
G = 3 ft ...........................clearance to gas service regulator
vent outlet
H = 12 inches.................clearance to non-mechanical (unpow-
ered) air supply inlet, combustion air
inlet or direct-vent termination
i = 3 ft. (U.S.A.)
6 ft. (Canada) ...........clearance to a mechanical (powered)
air supply inlet
All mechanical air intakes within 10 feet of a termination cap
must be a minimum of 3 feet below termination.
J = 7 ft. ......................... On public property: clearance above
paved sidewalk or a paved driveway.
A vent shall not terminate directly above a sidewalk or paved
driveway which is located between two single family dwellings
and serves both dwellings.
F
B
G
O
N
P
R
Q
H or i
V
X
M
V
H
V
H
E
V
V
A
V
K
V
L
Electrical
Service
C
V
K
V
Covered Alcove Applications
(Spaces open only on one side and with an overhang)
N = 6 inches ........... non-vinyl sidewalls
12 inches ......... vinyl sidewalls
O = 18 inches ......... non-vinyl soft and overhang
42 inches ......... vinyl soft and overhang
P = 8 ft.
Q
MIN
1 cap3 feet 2 x Q
2 caps6 feet 1 x Q
3 caps9 feet2/3 x Q
4 caps12 feet1/2 x Q
Q
= # termination caps x 3 R
MIN
Measure vertical clearances from this surface.
Measure horizontal clearances from this surface.
= (2 / # termination caps) x Q
MAX
CLEARANCE = 6 IN.
R
MAX
ACTUAL
ACTUAL
ACTUAL
ACTUAL
ACTUAL
K = 6 inches................. clearance from sides of electrical
service
L = 12 inches................ clearance above electrical service
Location of the vent termination must not interfere with access to the
electrical service.
M = 18inches ....................clearance under veranda, porch, deck,
balcony or overhang
42 inches ................vinyl or composite overhang
Permitted when veranda, porch, deck or balcony is fully open
on a minimum of 2 sides beneath the oor.
Figure 4.3 Minimum Clearances for Termination
14
Hearth & Home Technologies • LCOR-DV36IN, RCOR-DV36IN Installation Manual • 2486-980 Rev. F • 7/18
CAUTION! Risk of Burns! Termination caps are HOT,
consider proximity to doors, trafc areas or where people
may pass or gather (sidewalk, deck, patio, etc.). Listed cap
shields available. Contact your dealer.
• Local codes or regulations may require different
clearances.
• Vent system termination is NOT permitted in screened
porches.
• Vent system termination is permitted in porch areas with
two or more sides open.
• Hearth & Home Technologies assumes no responsibility
for the improper performance of the appliance when the
venting system does not meet these requirements.
• Vinyl protection kits are suggested for use with vinyl siding.
C. Approved Pipe
This appliance is approved for use with Hearth & Home
Technologies DVP or SLP venting systems. Refer to Section 12.A for vent component information and dimensions.
DO NOT mix pipe, ttings or joining methods from different manufacturers.
The pipe is tested to be run inside an enclosed wall.
There is no requirement for inspection openings at each
joint within the wall.
WARNING! Risk of Fire or Asphyxiation. This appliance requires a separate vent. DO NOT vent to a pipe
serving a separate solid fuel burning appliance.
Hearth & Home Technologies • LCOR-DV36IN, RCOR-DV36IN Installation Manual • 2486-980 Rev. F • 7/18
15
D. Use of Elbows
Diagonal runs have both vertical and horizontal vent aspects when calculating the effects. Use the rise for the
vertical aspect and the run for the horizontal aspect. See
Figure 4.4.
Two 45º elbows may be used in place of one 90º elbow.
On 45º runs, one foot of diagonal is equal to 8-1/2 in. (216
mm) horizontal run and 8-1/2 in. (216 mm) vertical run. A
length of straight pipe is allowed between two 45º elbows.
See Figure 4.4.
Figure 4.5 shows the vertical and horizontal offsets for
DVP or SLP elbows.
Y
X
VERTICAL
RISE
SLP
Pipe
EFFECTIVE
LENGTH
RUN
HORIZONTAL
Effective LengthRise/Run
InchesMillimetersInchesMillimeters
SLP441022-3/470
SLP661524-1/4108
SLP12123058-1/2216
SLP242461017432
SLP363691425-1/2648
SLP4848121934864
SLP6A3 to 676 to 152
SLP12A3 to 1276 to 305
2-1/8-4-1/454-108
2-1/8-8-1/254-216
Vent
Type
InchesMillimetersInchesMillimeters
XY
DVP4-1/211417432
SLP512711-3/4298
X
X
Vent Type
InchesMillimeters
DVP16-1/4413
SLP11-1/4286
Figure 4.5 Vertical and Horizontal Offset for DVP and SLP Elbows
X
DVP
Pipe
Effective LengthRise/Run
InchesMillimetersInchesMillimeters
DVP441022-3/470
DVP661524-1/4108
DVP12123058-1/2216
DVP242461017432
DVP363691425-1/2648
DVP4848121934864
DVP6A3 to 676 to 152
DVP12A3 to 1276 to 305
Figure 4.4
16
Hearth & Home Technologies • LCOR-DV36IN, RCOR-DV36IN Installation Manual • 2486-980 Rev. F • 7/18
2-1/8-4-1/454-108
2-1/8-8-1/254-216
E. Measuring Standards
Vertical and horizontal measurements listed in the vent
diagrams were made using the following standards:
• Pipe measurements are shown using the effective length
of pipe. See Section 12.A (Figure 12.1 for DVP, Figure
12.8 for SLP) for information on effective length of pipe
components.
• Horizontal terminations are measured to the outside
mounting surface (ange of termination cap) (see Figure
4.6).
• Vertical terminations are measured to top of last section
of pipe. See Figure 4.7.
• Horizontal pipe installed level with no rise.
MEASURE TO SHADED SURFACE
(OUTSIDE MOUNTING SURFACE)
F. Vent Diagrams
To replace the rst starter elbow with two 45° elbows,
refer to Figure 4.8. All other 90° elbows can be replaced
with two 45° elbows.
General Rules:
• SUBTRACT 3 ft. from the total H measurement for each
90º elbow installed horizontally.
• SUBTRACT 1-1/2 ft. from the total H measurement for
each 45º elbow installed horizontally.
• A maximum of three 90º elbows (or six 45º elbows) may
be used in any vent conguration. Some elbows may be
installed horizontally.
• Elbows may be placed back to back anywhere in the
system.
• Any 90º elbow may be replaced with two back to back
45º elbows.
• When penetrating a combustible wall, a wall shield
restop must be installed.
• When penetrating a combustible ceiling, a ceiling restop
must be installed.
• Horizontal runs of vent do not require vertical rise;
horizontal runs may be level.
• Horizontal termination cap should have a 1/4 inch
downward slant to allow any moisture in cap to be
released. See Figure 4.8.
Figure 4.6 Measure to Outside Mounting Surface
Top Vent Horizontal Termination
Two 45° Elbows
Installation requirements to replace the rst 90° elbow
with two 45° elbows:
4 ft min.
(1.22 m)
1/4 in. max.
(6 mm)
16 ft max.
(4.87 m)
Note: Reference Figure 4.21 for
special instructions for use of 45º
elbow on rear vent appliances.
Figure 4.7. Measure to Top of Last Section of Pipe
Hearth & Home Technologies • LCOR-DV36IN, RCOR-DV36IN Installation Manual • 2486-980 Rev. F • 7/18
Figure 4.8
17
Note: The LCOR-DV36IN/RCOR-DV36IN can adapt
to SLP series vent pipe, if desired.
When venting off the top of the unit, use a DVP-2SL adapter
and a minimum 48 inch vertical section of SLP series vent pipe.
A DVP-SLP24 adapter may also be used with a 24 inch
vertical section of SLP series vent pipe.
After the 48 inch vertical section, the venting table rules
must be followed. The rst 48 inch vertical section is NOT
counted as part of the vertical components in the table. It is
still counted as part of the overall maximum run. All venting
table rules for the vent run must still be followed.
Example: DVP pipe 1 ft. min. vertical = 3 ft. max. horizontal
SLP pipe 5 ft. min. vertical = 3 ft. max. horizontal
(IDENTICAL VENT RUNS USING DVP AND SLP PIPE)
HORIZONTAL EXAMPLE
DVP PIPE
V1 = 1 ft. (305 mm)
H1 = 3 ft. (914 mm)
max.
SLP PIPE
V1 = 1 ft. (305 mm)
H1 = 3 ft. (914 mm)
max.
4 ft. SLP (1.2 m)
DVP-2SL
(IDENTICAL VENT RUNS USING DVP AND SLP PIPE)
3 ft (914 mm) min.
60 ft (18.3 m) max.
AND
OR
VERTICAL EXAMPLE
3 ft (914 mm) min.
56 ft (17 m) max.
2 ft. SLP
(305 mm)
2 ft. SLP (305 mm)
DVP-SLP24
18
DVP-SLP24
Adapter
DVP
SLP
Figure 4.9 Adapt DVP Pipe to SLP Using DVP-SLP24 & DVP-2SL
Hearth & Home Technologies • LCOR-DV36IN, RCOR-DV36IN Installation Manual • 2486-980 Rev. F • 7/18
OR
4 ft. SLP
AND
DVP-2SL
Top Vent - Horizontal Termination
One Elbow
Figure 4.10
H
V1 MinimumH1 Maximum
Elbow only1-1/2 ft.457 mm
6 in.152 mm2-1/2 ft.610 mm
1 ft.305 mm3 ft.914 mm
2 ft.610 mm6 ft1.8 m
3 ft.914 mm9 ft.2.7 m
4 ft.1.2 m12 ft.3.7 m
V
1
1
5 ft.1.5 m15 ft.4.6 m
6 ft.1.8 m18 ft.5.5 m
+ H1 = 50 ft. (15.2 m) Maximum
V
1
H1 = 18 ft. (5.5 m) Maximum
Two Elbows
H
V1 MinimumH1 + H2 Maximum
Elbow only6 in.152 mm
1 ft.305 mm2 ft.610 mm
2 ft.610 mm4 ft.1.2 m
3 ft.914 mm9 ft.2.7 m
4 ft1.2 m12 ft.3.7 m
5 ft.1.5 m15 ft.4.6 m
6 ft.1.8 m18 ft. 5.5 m
+ H1 + H2 = 50 ft. (15.2 m) Maximum
V
1
H1 + H2 = 18 ft. (5.5 m) Maximum
V
2
H
1
1
Figure 4.11
INSTALLED
HORIZONTALLY
Hearth & Home Technologies • LCOR-DV36IN, RCOR-DV36IN Installation Manual • 2486-980 Rev. F • 7/18