• Important operating
and maintenance
instructions included.
WARNING: If the information in these
instructions is not followed exactly, a re
or explosion may result causing property
damage, personal injury, or death.
• DO NOT store or use gasoline or other am-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s instructions.
- If you cannot reach your gas supplier, call
the re department.
• Read, understand and follow
these instructions for safe
installation and operation.
DO NOT
DISCARD
• Leave this manual with
party responsible for use
and operation.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• DO NOT touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
replace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other ammable
materials.
• Keep clothing, furniture, draperies and other ammable
materials away.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas tter.
A CO detector shall be installed in the room where the appliance
in installed.
• Installation and service must be performed
by a qualied installer, service agency, or the
gas supplier.
Installation and service of this appliance should be performed by
qualied personnel. Hearth & Home Technologies recommends
HHT Factory Trained or NFI certied professionals.
Hearth & Home Technologies • RBV4236/RBV4842 • 4048-210 • Rev AM • 02/211
Read this manual before installing or operating this appliance.
Please retain this owner’s manual for future reference.
A. Congratulations
Congratulations on selecting a Hearth & Home Technologies gas replace, an elegant and clean alternative to wood
burning replaces. The Hearth & Home Technologies gas
replace you have selected is designed to provide the utmost in safety, reliability, and eciency.
As the owner of a new replace, you’ll want to read and
carefully follow all of the instructions contained in this
owner’s manual. Pay special attention to all cautions and
warnings.
This owner’s manual should be retained for future reference.
We suggest that you keep it with your other important
documents and product manuals.
The information contained in this owner’s manual, unless
noted otherwise, applies to all models and gas control
systems.
Your new Hearth & Home Technologies gas replace will
give you years of durable use and trouble-free enjoyment.
Welcome to the Hearth & Home Technologies family of
replace products!
Homeowner Reference Information
We recommend that you record the following pertinent
information about your replace.
Model Name: ___________________________________________ Date purchased/installed: __________________
Serial Number: __________________________________________ Location on replace: _____________________
The model information regarding your specic replace can be found on
the rating plate usually located in the control area of the replace.
Serial #
XXXXXXXXX
Model #
Hearth & Home Technologies Inc
7571 215th Street West
Lakeville, MN 55044
ANSI Standard
Gas Type
SERIAL
NO. DE SÉRIE
MODEL MFG. DATE
MODÈLE DATE DE FAB.
GAS TYPE/TYPE DE GAZ NATURAL/NATUREL PROPANE
ALTITUDE 0-2000 2000-4000 FT/PI 0-2000 2000-4000 FT/PI
MAX INPUT/DÉBIT XX,XXX XX,XXX BTUH XX,XXX XX,XXX BTUH
MIN INPUT/DÉBIT XX,XXX XX,XXX BTUH XX,XXX XX,XXX BTUH
MANIFOLD PRESSURE/PRESSION TUBULAIRE
MAX. XX IN. W.C./C. D'EAU XX IN. W.C./C. D'EAU
MIN. XX IN. W.C./C. D'EAU XX IN. W.C./C. D'EAU
MIN. INLET PRESS. XX IN. W.C./C. D'EAU 1XX IN. W.C./C. D'EAU
FOR THE PURPOSE OF INPUT ADJUSTMENT
PRESS. MIN. D'ALIMENTATION
ORIFICE SIZE
DIAM. DE L'INJECTEUR XX/XX DIA. in./mm XX/XX DIA. in./mm
LESS THAN/MOINS DE 3 AMPÈRES., 115V., 60 Hz
DO NOT REMOVE OR COVER THIS LABEL.
VENTED GAS FIREPLACE - NOT FOR USE WITH SOLID FUEL.
FOYER À GAZ À ÉVACUATION - NE DOIT PAS ÊTRE UTILISÉ
AVEC UN COMBUSTIBLE SOLIDE.
XXXXXX
Hearth & Home Technologies • RBV4236/RBV4842 • 4048-210 • Rev AM • 02/212
CERTIFIÉ POUR LE
XXXX
CERTIFIED
FOR CANADA
CANADA
Orifice
Size
Safety Alert Key:
• DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury.
• WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury.
• CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
• NOTICE: Used to address practices not related to personal injury.
Table of Contents
A. Congratulations 2
►
B. Warranty 4
1 Listing and Code Approvals
A. Appliance Certication 6
B. Tempered Glass Specications 6
C. BTU Specications
D. High Altitude Installations 6
E. Non-Combustible Materials Specication 6
F. Combustible Materials Specication 6
G. Electrical Codes 6
User Guide
2 Operating Instructions
A. Gas Fireplace Safety 7
B. Your Fireplace 7
C. Clear Space 8
D. Decorative Doors and Fronts 8
E. Remote Controls, Wall Controls and Wall Switches 8
F. Outside Air (optional) 8
G. Before Lighting Fireplace 8
H. Lighting Instructions (IPI) 9
I. After Fireplace is Lit 10
J. Frequently Asked Questions 10
3 Maintenance and Service
A. Maintenance Tasks-Homeowner 11
B. Maintenance Tasks-Qualied Service Technician 12
Installer Guide
4 Getting Started
A. Typical Appliance System 13
B. Design and Installation Considerations 14
C. Tools and Supplies Needed 14
D. Inspect Appliance and Components 14
E. Negative Pressure 15
5 Framing and Clearances
A. Selecting Appliance Location 16
B. Constructing the Appliance Chase 17
C. Clearances 17
D. Mantel and Wall Projections 18
6 Termination Locations
A. Vent Termination Minimum Clearances 19
7 Vent Information and Diagrams
A. Vent Guidelines 20
B. Vent System Conguration 20
8 Vent Clearances and Framing
A. Pipe Clearances to Combustibles 21
B. Wall and Ceiling Penetration Framing 21
C. Vertical Penetration Framing 21
9 Appliance Preparation
A. Installing Outside Air Kit Damper Assembly 22
B. Gas and Electrical Connections 22
C. Securing and Leveling the Appliance 22
10 Installing Vent Pipe
A. Assembly of Vent Sections 23
B. Attaching Vent to Firebox 23
C. Securing Vent Sections 23
D. Install Attic Insulation Shield 23
11 Gas Information
A. Fuel Conversion 24
B. Gas Pressure 24
C. Gas Connection 24
D. High Altitude Installations 24
12 Electrical Information
A. Wiring Requirements 25
B. Intellire Ignition System Wiring 25
C. Optional Accessories Requirements 25
D. Electrical Service and Repair 26
E. Junction Box Installation 27
13 Finishing
A. Mantel and Wall Projections 28
B. Facing Material 29
14 Appliance Setup
A. Remove the Shipping Materials 30
B. Remove Shipping Supports 30
C. Clean the Appliance 30
D. Accessories 30
E. Install the Log Assembly 30
F. Place the Lava Rock & Vermiculite 33
G. Place the Rockwool 34
H. Glass Door Assembly 34
I. Install Hood 35
J. Air Shutter Setting 35
15 Troubleshooting
A. Intellire Ignition System 36
16 Reference Materials
A. Appliance Dimension Diagram 38
B. Service Parts List 39
►
C. Optional Components 43
D. Contact Information 45
= Contains updated information.
Hearth & Home Technologies • RBV4236/RBV4842 • 4048-210 • Rev AM • 02/213
recoverable under this Warranty is limited to the purchase price of the Product. This Warranty is transferable from the original purchaser
Component
Igniters, Auger Motors, Electronic Components, and
►
B. Warranty
Hearth & Home Technologies LLC
LIMITED LIFETIME WARRANTY
Hearth & Home Technologies LLC (“HHT”) extends the following warranty for HHT gas, wood, pellet and electric hearth appliances
(each a “Product” and collecvely, the “Product(s)”) and certain component parts set forth in the table below (“Component Part(s)”)
that are purchased from a HHT authorized dealer or distributor.
WARRANTY COVERAGE:
HHT warrants that the Products and their Component Parts will be free from defects in materials and workmanship for the applicable
period of Warranty coverage set forth in the table below (“Warranty Period”). If a Product or Component Parts are found to be
defecve in materials or workmanship during the applicable Warranty Period, HHT will, at its opon, repair the applicable Component
Part(s), replace the applicable Component Part(s), or refund the purchase price of the applicable Product(s). The maximum amount
to subsequent owners, but the Warranty Period will not be extended in duraon or expanded in coverage for any such transfer. This
Warranty is subject to condions, exclusions, and limitaons as described below.
WARRANTY PERIOD:
Warranty coverage begins at the date of installaon. In the case of new home construcons, Warranty coverage begins on the date of
rst occupancy of the dwelling or six months aer the sale of the Product(s) by an independent, authorized HHT dealer or distributor,
whichever occurs earlier. However, the Warranty coverage shall commence no later than 24 months following the date of Product
shipment from HHT, regardless of the installaon or occupancy date.
The term “Lifeme” in the table below is dened as: 20 years from the beginning date of warranty coverage for gas appliances, and 10
years from the beginning date of warranty coverage for wood and pellet appliances. These me periods reect the minimum expected
useful lives of the designated Component Parts under normal operang condions.
Warranty PeriodHHT Manufactured Appliances and Venting
Parts
5 years1 year
6 years3 yearsXCatalysts
7 years3 yearsXXManifold tubes, HHT Chimney and Terminations
LaborGas Pellet WoodElectricVentingComponent Parts Covered by this Warranty
All parts including handles, external enameled
components and other material except as covered by
2 Years
2 years
3 yearsX
X
XXMolded Refractory Panels, Glass Liners
XVent Free Burners, Vent Free Logs
X1 YearXXX
X
XX
XXCastings, Medallions and Baffles
Warranty Conditions, Warranty Exclusions, and
Warranty Limitations listed
All parts except as covered by Warranty Conditions,
Warranty Exclusions, and Warranty Limitations listed
Glass
Electrical components limited to modules, remotes/wall
harnesses, transformers and lights (excluding light bulbs)
Firepots, burnpots, mechanical feeders/auger
assemblies
10 years1 yearXBurners, logs and refractory
Limited
Lifetime
1 Year
4021-645L 10/20
3 yearsXXX
None
Firebox and heat exchanger, FlexBurn® System
(engine, inner cover, access cover and fireback)
XXXXXAll purchased replacement parts
Page 1 of 2
Hearth & Home Technologies • RBV4236/RBV4842 • 4048-210 • Rev AM • 02/214
Warranty (continued)
WARRANTY CONDITIONS:
• Because HHT cannot control the quality of any Products sold by unauthorized sellers, this Warranty only covers Products that are
purchased through an HHT authorized dealer or distributor unless otherwise prohibited by law; a list of HHT authorized dealers
is available on the HHT branded websites.
• This Warranty is only valid while the applicable Product remains at the site of original installaon.
• This Warranty is only valid in the country in which the HHT authorized dealer or distributor that sold the applicable Product is
authorized to sell applicable Product.
• Contact your installing distributor or dealer for Warranty service. If the installing dealer or distributor is unable to provide
necessary parts, contact the nearest HHT authorized dealer or supplier. Addional service fees may apply if you are seeking
Warranty service from a dealer other than the dealer from whom you originally purchased the applicable Product.
• No HHT consumer should bear cost of warranty service or costs incurred while servicing warranty claims (i.e., travel, gas, or
mileage) when the service is performed within the terms of this Warranty. Check with your dealer or distributor in advance for
any costs to you when arranging a warranty call. Travel and shipping charges for parts are not covered by this Warranty.
WARRANTY EXCLUSIONS:
This Warranty does not cover the following:
• Changes in surface nishes as a result of normal use. As a heang appliance, some changes in color of interior and exterior surface
nishes may occur. This is not a aw and is not covered under the Warranty.
• Damage to printed, plated, or enameled surfaces caused by ngerprints, accidents, misuse, scratches, melted items or other
external sources and residues le on the plated surfaces from the use of abrasive cleaners or polishes.
• Repair or replacement of parts that are subject to normal wear and tear during the Warranty Period are not covered. These parts
include: paint, wood and pellet gaskets, rebricks, grates, ame guides, baeries and the discoloraon of glass.
• Minor expansion, contracon, or movement of certain parts causing noise. These condions are normal and complaints related to
this noise are not covered by this Warranty.
• Damages resulng from: (1) failure to install, operate, or maintain the applicable Product in accordance with the installaon
instrucons, operang instrucons, and lisng agent idencaon label furnished with the applicable Product; (2) failure to
install the applicable Product in accordance with local building codes; (3) shipping or improper handling; (4) improper operaon,
abuse, misuse, connued operaon with damaged, corroded or failed components, accident, or improperly/incorrectly performed
repairs; (5) environmental condions, inadequate venlaon, negave pressure, or draing caused by ghtly sealed construcons,
insucient make-up air supply, or handling devices such as exhaust fans or forced air furnaces or other such causes; (6) use of fuels
other than those specied in the operaon instrucons; (7) installaon or use of components not supplied with the applicable
Product or any other components not expressly authorized and approved by HHT; (8) modicaon of the appliance not expressly
authorized and approved by HHT in wring; and/or (9) interrupons or uctuaons of electrical power supply to the applicable
Product.
• Non-HHT venng components, hearth connecons or other accessories used in conjuncon with the applicable Product.
• Any part of a pre-exisng replace system in which an insert or a decorave gas applicable Product is installed.
• HHT’s obligaon under this Warranty does not extend to the Product’s capability to heat the desired space. Informaon is provided
to assist the consumer and the dealer in selecng the proper Product for the applicaon. Consideraon must be given to the
Product locaon and conguraon, environmental condions, insulaon and air ghtness of the structure.
This warranty is void if:
• The applicable Product has been over-red, operated in atmospheres contaminated by chlorine, uorine, or other damaging
chemicals. Over-ring can be idened by, but not limited to, warped plates or tubes, deformaon/warping of interior cast iron
structure or components, rust colored cast iron, bubbling, cracking and discoloraon of steel or enamel nishes.
• The applicable Product is subjected to prolonged periods of dampness or condensaon.
• There is any damage to the applicable Product due to water or weather damage which is the result of, but not limited to, improper
chimney or venng installaon.
LIMITATIONS OF REMEDIES AND LIABILITY:
• EXCEPT TO THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED
HEREIN. The owner’s exclusive remedy and HHT’s sole obligaon under this Warranty or in contract, tort or otherwise, shall be
limited to replacement of the Component Part(s), repair of the Component Part(s), or refund of the original purchase price of the
applicable Product(s), as specied above; provided, however, that (i) if HHT is unable to provide replacement of the Component
Part(s) and repair of the Component Part(s) is not commercially praccable or cannot be mely made, or (ii) the customer is
willing to accept a refund of the purchase price of the applicable Product(s), HHT may discharge all such obligaons by refunding
the purchase price of the applicable Product. In no event will HHT be liable for any incidental or consequenal damages caused
by defects in the applicable Product. Some States do not allow the exclusion or limitaon of incidental or consequenal damages,
so the above limitaon or exclusion may not apply to you. This Warranty gives you specic legal rights and you may also have
other rights which vary from State to State. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE
EXPRESSED WARRANTY SPECIFIED ABOVE FOR THE APPLICABLE PRODUCT. Some States do not allow limitaons on how long an
implied warranty lasts, so the above limitaon may not apply to you.
4021-645L 10/20
Page 2 of 2
Hearth & Home Technologies • RBV4236/RBV4842 • 4048-210 • Rev AM • 02/215
1
Listing and Code Approvals
A. Appliance Certication
MODELS: RBV4236/RBV4842 Series
LABORATORY: Underwriters Laboratories, Inc. (UL)
TYPE: Vented Decorative Gas Appliances
STANDARD: ANSI Z21.50-2016/CSA 2.22-2016
NOTICE: This installation must conform with local codes
or, in the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and
Propane Installation Code, CSA B149.1.
VENTED DECORATIVE GAS APPLIANCE: NOT A SOURCE
OF HEAT; NOT FOR USE WITH SOLID FUEL.This appliance is
tested and approved as either supplemental room heat or as a
decorative appliance. It should not be factored as primary heat
in residential heating calculations.
B. Tempered Glass Specications
Hearth & Home Technologies appliances manufactured
with tempered glass may be installed in hazardous loca-
tions such as bathtub enclosures as dened by the Consumer Product Safety Commission (CPSC). The tempered
glass has been tested and certied to the requirements
of ANSI Z97.1 and CPSC 16 CFR 1202 (Safety Glazing
Certication Council SGCC# 1595 and 1597. Architectural
Testing, Inc. Reports 02-31919.01 and 02-31917.01).
This statement is in compliance with CPSC 16 CFR Section 1201.5 “Certication and labeling requirements” which
refers to 15 U.S. Code (USC) 2063 stating “…Such certicate shall accompany the product or shall otherwise be
furnished to any distributor or retailer to whom the product
is delivered.”
Some local building codes require the use of tempered
glass with permanent marking in such locations. Glass
meeting this requirement is available from the factory.
Please contact your dealer or distributor to order.
C. BTU Specications
Reveal SeriesRBV4236RBV4842
IPI
Input Rate (NG) 40,000 BTUH 43,000 BTUH
Orice Size (NG) #31/3.05 mm .12 5 i n . / 3 .18 mm
Input Rate
(PROPAN E38,000 BTUH 41,000 BTUH
Orice Size
(PROPAN E)#49/1.85 mm#48/1.93 mm
D. High Altitude Installations
NOTICE: If the heating value of the gas has been reduced,
these rules do not apply. Check with your local gas utility or
authorities having jurisdiction.
When installing above 2000 feet elevation:
• In the USA: Reduce input rate 4% for each 1000 feet
above 2000 feet.
• In CANADA: Reduce input rate 10% for elevations
between 2000 feet and 4500 feet. Above 4500 feet,
consult local gas utility.
Check with your local gas utility to determine proper
orice size.
E. Non-Combustible Materials Specication
Material which will not ignite and burn. Such materials are
those consisting entirely of steel, iron, brick, tile, concrete,
slate, glass or plasters, or any combination thereof.
Materials that are reported as passing ASTM E 136, Standard Test Method for Behavior of Materials in a Vertical
Tube Furnace at 750 ºC and UL763 shall be considered
non-combustible materials.
F. Combustible Materials Specication
Materials made of or surfaced with wood, compressed
paper, plant bers, plastics, or other material that can ignite and burn, whether ame proofed or not, or plastered
or unplastered shall be considered combustible materials.
WARNING: This product and the
fuels used to operate this product (liquid
propane or natural gas), and the products
of combustion of such fuels, can expose
you to chemicals including benzene, which
is known to the State of California to cause
cancer and reproductive harm. For more
information go to: www.P65Warnings.
ca.gov.
Hearth & Home Technologies • RBV4236/RBV4842 • 4048-210 • Rev AM • 02/216
G. Electrical Codes
NOTICE: This appliance must be electrically wired
and grounded in accordance with local codes or, in the
absence of local codes, with National Electric Code
ANSI/NFPA 70-latest edition or the Canadian Electric
Code CSA C22.1.
• A 110-120 VAC circuit for this product must be protected
with ground-fault circuit-interrupter protection, in
compliance with the applicable electrical codes, when
it is installed in locations such as in bathrooms or near
sinks.
User Guide
2
A. Gas Fireplace Safety
Operating Instructions
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• DO NOT touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
replace.
• Alert children and adults to hazards of high
temperatures.
High temperatures may ignite clothing or other ammable
materials.
• Keep clothing, furniture, draperies and other ammable
materials away.
• Install a switch lock or a wall/remote control with child
protection lockout feature.
• Keep remote controls out of reach of children.
• Never leave children alone near a hot replace, whether
operating or cooling down.
• Teach children to NEVER touch the replace.
• Consider not using the replace when children will be
present.
Contact your dealer for more information, or visit: www.
hpba.org/staysafe.
To prevent unintended operation when not using your
replace for an extended period of time (summer months,
vacation, trips, etc):
• Remove batteries from remote controls.
• Turn o wall controls.
• Unplug 3 volt adapter plug and remove batteries on IPI
models.
If you expect that small children or vulnerable adults may
come into contact with this replace, the following precautions are recommended:
• Install a physical barrier such as:
- A decorative rescreen.
- Adjustable safety gate.
Decorative Doors or Fronts
(not shown) Section 2.D.
Outside Air
UP - Closed
DOWN - Open
B. Your Fireplace
WARNING! DO NOT operate replace before reading
and understanding operating instructions. Failure
to operate replace according to operating instructions
could cause re or injury.
Mantel
Section 5.D.
Figure 2.1 General Operating Parts
Hearth & Home Technologies • RBV4236/RBV4842 • 4048-210 • Rev AM • 02/217
High Limit Switch
Clear Space
Section 2.C.
Hearth
(not required)
Remote Control
Section 2.E.
C. Clear Space
WARNING! DO NOT place combustible objects in
front of the replace or block louvers. High tempera-
tures may start a re. See Figure 2.2.
Avoid placing candles and other heat-sensitive objects on
mantel or hearth. Heat may damage these objects.
Clear Space
3 ft (0.91 m)
in front of
appliance
E. Remote Controls, Wall Controls and Wall
Switches
Follow the instructions supplied with the control installed
to operate your replace:
For safety:
• Install a switch lock or a wall/remote control with child
protection lockout feature.
• Keep remote controls out of reach of children.
See your dealer if you have questions.
F. Outside Air (optional)
The outside air kit supplies some fresh combustion air for
your replace. It may help reduce the eects of negative
air pressure. (See Section 9.A.)
• Refer to Figure 2.1 for location of control.
• Close the inlet to prevent cold drafts when the replace
is not being used.
CAUTION! Risk of Burns! The outside air control handle
is HOT when replace is in operation. Adjust BEFORE
lighting re.
Figure 2.2 Clear Space
D. Decorative Doors and Fronts
WARNING! Risk of Fire! Install ONLY doors or fronts
approved by Hearth & Home Technologies. Unapproved
doors or fronts may cause replace to overheat.
For more information refer to the instructions supplied
with your decorative door or front.
G. Before Lighting Fireplace
Before operating this replace for the rst time, have a
qualied service technician:
• Verify all shipping materials have been removed from
inside and/or underneath the rebox.
• Review proper placement of logs, ember material and/or
other decorative materials.
• Check the wiring.
• Check the air shutter adjustment.
• Ensure that there are no gas leaks.
WARNING! RISK OF Fire/Asphyxiation! DO NOT operate
replace with rescreen assembly removed.
Hearth & Home Technologies • RBV4236/RBV4842 • 4048-210 • Rev AM • 02/218
H. Lighting Instructions (IPI)
• For normal use, activate/deactivate your replace with the wall switch or remote control.
• The IPI system may be operated with two D-cell batteries. When using batteries, unplug the transformer. To prolong
battery life, remove them when using the transformer.
• If your replace must be deactivated for serviced or an extended period of time, follow the instructions below.
This appliance needs fresh air for safe operation
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or
explosion may result causing property damage, personal
injury or loss of life.
A. This appliance is equipped with an ignition device which
automatically lights the pilot. Do not try to light the pilot by hand.
B. BEFORE LIGHTING smell all around the appliance area for gas.
Be sure to smell next to the floor because some gas is heavier
than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in your
building.
• Immediately call your gas supplier from a neighbor's phone.
Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push in and move the gas control valve
or turn the gas control knob. Never use tools. If the lever or
knob will not move by hand, don't try to repair it, call a qualified
service technician. Force or attempted repair may result in a fire
or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and any
gas control which has been under water.
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information above on this label.
2. Turn wall switch to the "OFF" position to the lowest setting.
3. Turn off all electric power to the appliance.
4. This appliance is equipped with an ignition device which
automatically lights the pilot. Do NOT try to light the pilot by
hand.
5. Wait five minutes to clear out any gas. If you then smell gas, STOP!
Follow "B" in the safety information above on this label. If you don't smell
gas, go to the next step.
6. To turn on the burner, turn on all electric power to this appliance and turn
on the wall switch.
7. If the appliance will not operate, follow the instructions "TO TURN OFF
GAS TO APPLIANCE" and call your service technician or gas supplier.
TO TURN OFF GAS TO APPLIANCE
1. Turn off wall switch.
2. Turn off all electric power to the appliance if service is to be
performed.
WARNING: This product and the fuels used
to operate this product (liquid propane or
natural gas), and the products of combustion of such
fuels, can expose you to chemicals including
benzene, which is known to the State of California to
cause cancer and reproductive harm. For more
information go to: www. P65Warnings.ca.gov
Due to high surface temperatures, keep children, clothing and furniture away.
Keep burner and control compartment clean. See installation and operating instructions accompanying the appliance.
3. Push the gas control lever in and move to the "OFF" position or
push the gas control lever to the "OFF" position. Do not force.
4. Replace the control access panel.
For use with natural gas or propane. A conversion kit as supplied by
the manufacturer shall be used to convert this appliance to the
alternative fuel.
* Also certified for installation in a bedroom or
a bed-sitting room.
* For U.S. only!
33631G
and must be installed so there are provisions for
adequate combustion and ventilation air.
This appliance must be installed in accordance
with local codes, if any; if not, follow ANSI Z223.1
or, in Canada, current CAN/CGA-B149.
This appliance must be properly connected to a
venting system in accordance with the
manufacturer's installation instructions.
WARNING:
adjustment, alteration, service or maintenance can
cause injury or property damage. Refer to the
owner's information manual provided with the
appliance. For assistance or additional information
consult a qualified installer, service agency or the
gas supplier.
CAUTION:
not touch. Keep children, clothing, furniture,
gasoline and other liquids having flammable vapors
away.
Improper installation,
Hot while in operation. Do
WARNING RISK OF FIRE
This appliance is intended to burn a specified gas
fuel only. Do not attempt to use with solid wood fuel
or another type of fuel. Do not attempt to modify or
use any other type of gas burner system.
WARNING:
power before servicing. If for any reason the original
wire supplied with the appliance must be replaced, it
must be replaced with 105° C or its equivalent.
Disconnect the electric
NG
NG
NG
NG
Hearth & Home Technologies • RBV4236/RBV4842 • 4048-210 • Rev AM • 02/219
I. After Fireplace is Lit
Initial Break-in Procedure
• The fireplace should be run three to four hours
continuously on high.
• Turn the replace o and allow it to completely cool.
• Run continuously on high an additional 12 hours.
This cures the materials used to manufacture the replace.
NOTICE! Open windows for air circulation during replace
break-in.
• Some people may be sensitive to smoke and
odors.
• Smoke detectors may activate.
J. Frequently Asked Questions
ISSUESOLUTIONS
Condensation on the glassThis is a result of gas combustion and temperature variations. As the appliance warms, this
condensation will disappear.
Blue amesThis is a result of normal operation and the ames will begin to yellow as the appliance is allowed
to burn for 20 to 40 minutes.
Odor from applianceWhen rst operated, this appliance may release an odor for the rst several hours. This is
caused by the curing of materials from manufacturing. Odor may also be released from nishing
materials and adhesives used near the appliance. These circumstances may require additional
curing related to the installation environment.
Film on the glassThis is a normal result of the curing process of the paint and logs. Glass should be cleaned within
3 to 4 hours of initial burning. A non-abrasive cleaner such as gas appliance glass cleaner may
be necessary. See your dealer.
Metallic noiseNoise is caused by metal expanding and contracting as it heats up and cools down, similar to
the sound produced by a furnace or heating duct. This noise does not aect the operation or
longevity of the appliance.
Is it normal to see the pilot
ame burn continually?
In an IntelliFire ignition system (IPI), the pilot ame should turn o when appliance is turned o.
Some optional control systems available with IPI models may allow pilot ame to remain lit. In a
standing pilot system the pilot will always stay on.
Hearth & Home Technologies • RBV4236/RBV4842 • 4048-210 • Rev AM • 02/2110
3
Maintenance and Service
Any safety screen or guard removed for servicing must be
replaced prior to operating the replace.
When properly maintained, your replace will give you
many years of trouble-free service. We recommend an-
nual service by a qualied service technician.
A. Maintenance Tasks-Homeowner
Installation and repair should be done by a qualied service
technician only. The replace should be inspected before use
and at least annually by a professional service person.
The following tasks may be performed annually by the
homeowner. If you are uncomfortable performing any of
the listed tasks, please call your dealer for a service appointment.
More frequent cleaning may be required due to lint from
carpeting or other factors. Control compartment, burner
and circulating air passageway of the replace must be
kept clean.
CAUTION! Risk of Burns! The replace should be
turned o and cooled before servicing.
Doors, Surrounds, Fronts
Frequency: Annually
By: Homeowner
Tools needed: Protective gloves, stable work surface
• Assess condition of glass and replace as necessary.
• Inspect for scratches, dents or other damage and repair
as necessary.
• Vacuum and dust surfaces.
Remote Control
Frequency: Seasonally
By: Homeowner
Tools needed: Replacement batteries and remote control in-
structions.
• Locate remote control transmitter and receiver.
• Verify operation of remote. Refer to remote control
operation instructions for proper calibration and setup
procedure.
• Place batteries as needed in remote transmitters and
battery-powered receivers.
• Place remote control out of reach of children.
If not using your replace for an extended period of time
(summer months, vacations/trips, etc), to prevent unintended operation:
• Remove batteries from remote controls.
• Unplug 3 volt adapter plug on IPI models.
Venting
Frequency: Seasonally
By: Homeowner
Tools needed: Protective gloves and safety glasses.
• Inspect venting and termination cap for blockage or
obstruction such plants, bird nests, leaves, snow, debris,
etc.
• Verify termination cap clearance to subsequent
construction (building additions, decks, fences, or
sheds). See Section 6.
• Inspect for corrosion or separation.
• Verify weather stripping, sealing and ashing remains
intact.
• Inspect draft shield to verify it is not damaged or missing.
Hearth & Home Technologies • RBV4236/RBV4842 • 4048-210 • Rev AM • 02/2111
B. Maintenance Tasks-Qualied Service
Technician
The following tasks must be performed by a qualied
service technician.
Logs
Frequency: Annually
By: Qualied Service Technician
Tools needed: Protective gloves.
• Inspect for damaged or missing logs. Replace as
necessary. Refer to Section 14.D. for log placement
instructions.
• Verify correct log placement and no ame impingement
• Vacuum and wipe out dust, cobwebs, debris or pet hair.
Use caution when cleaning these areas. Screw tips that
have penetrated the sheet metal are sharp and should
be avoided.
broom, ashlight, voltmeter, indexed drill bit set, and a manometer.
• Verify burner is properly secured and aligned with
igniter.
• Clean o burner top, inspect for plugged ports, corrosion
or deterioration. Replace burner if necessary.
• Replace ember materials with new dime-size pieces.
DO NOT block ports or obstruct lighting paths. Refer to
Section 14 for proper ember placement.
• Verify batteries have been removed from battery backup IPI systems to prevent premature battery failure or
leaking.
• Check for smooth lighting and ignition carryover to all
ports. Verify that there is no ignition delay.
• Inspect for lifting or other ame problems.
• Verify air shutter setting is correct. See Section 14.J.
for required air shutter setting. Verify air shutter is clear
of dust and debris.
• Inspect orice for soot, dirt and corrosion. Verify orice
size is correct. See Service Parts List for proper orice
sizing.
• Verify manifold and inlet pressures. Adjust regulator as
required.
• Inspect pilot ame pattern and strength. See Figure 3.1
for proper pilot ame pattern. Clean or replace orice
spud as necessary.
• Inspect IPI ame sensing rod for soot, corrosion and
deterioration. Clean with emery cloth or replace as
required.
• Verify that there is not a short in ame sensing circuit
by checking continuity between pilot hood and ame
sensing rod. Replace pilot as necessary.
Figure 3.1 IPI Pilot Flame Patterns
Hearth & Home Technologies • RBV4236/RBV4842 • 4048-210 • Rev AM • 02/2112
4
A. Typical Appliance System
NOTICE: Illustrations and photos reect typical installations and are for design purposes only. Illustrations/diagrams are not
drawn to scale. Actual product may vary from pictures in manual
Getting Started
Vertical Termination Cap
Noncombustible roof
flashing maintains minimum
clearance around pipe
Storm Collar
Vent pipe penetrates roof,
preferably without affecting
roof rafters
Installer Guide
Listed B-Vent Pipe
Ceiling Firestop
on floor of attic
Framing/Header
(SECTION 5)
Attic insulation shield (not shown) must be used here to
keep insulation away from vent pipe if attic is insulated.
Framing Headed off
in Ceiling Joists
(SECTION 8)
Optional
Wall Switch
Mantel & Mantel Leg
(SECTION 13)
Surround
Hearth Extension
(not required)
Gas Line
(SECTION 11)
Figure 4.1 Typical System
Hearth & Home Technologies • RBV4236/RBV4842 • 4048-210 • Rev AM • 02/2113
B. Design and Installation Considerations
Hearth & Home Technologies B-type vent gas appliances
are designed to operate with all exhaust gases expelled
to the outside of the building, and combustion air pulled
from the room.
Installation MUST comply with local, regional, state and
national codes and regulations. Consult insurance carrier,
local building inspector, re ocials or authorities having
jurisdiction over restrictions, installation inspection and
permits.
Before installing, determine the following:
• Where the appliance is to be installed.
• The vent system conguration to be used.
• Gas supply piping.
• Electrical wiring requirements.
• Framing and nishing details.
• Whether optional accessories—devices such as a fan,
wall switch, or remote control—are desired.
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. For
assistance or additional information, consult a qualied
service technician, service agency or your dealer.
D. Inspect Appliance and Components
The following B-vent components are needed for installation.
• Fireplace Box
• Pipe Components
• Firestops
• Attic Insulation Shield
• Elbows
• Strapping
• Roof Flashing or Chase Top
• Termination Cap
• Storm Collar
• Carefully remove the appliance and components from
the packaging.
• The vent system components and decorative doors and
fronts may be shipped in separate packages.
• If packaged separately, the log set and appliance grate
must be installed.
• Report to your dealer any parts damaged in shipment,
particularly the condition of the glass.
• Read all of the instructions before starting the installation.
Follow these instructions carefully during the installation
to ensure maximum safety and benet.
C. Tools and Supplies Needed
Before beginning the installation be sure that the following tools and building supplies are available.
Tape measure Framing material
Pliers High temperature caulking
material
Hammer Phillips screwdriver
Gloves Framing square
Voltmeter Electric drill and bits (1/4 in.)
Plumb line Safety glasses
Level Reciprocating saw
Manometer Flat blade screwdriver
Noncorrosive leak check solution
1/2 - 3/4 in. length, #6 or #8 Self-drilling screws
WARNING! Risk of Fire or Explosion! Damaged parts
could impair safe operation. DO NOT install damaged,
incomplete or substitute components. Keep appliance dry.
Hearth & Home Technologies disclaims any responsibility for,
and the warranty will be voided by, the following actions:
• Installation and use of any damaged appliance or vent
system component.
• Modication of the appliance or vent system.
• Installation other than as instructed by Hearth & Home
Technologies.
• Improper positioning of the gas logs or the glass
door.
• Installation and/or use of any component part not
approved by Hearth & Home Technologies.
Any such action may cause a re hazard.
WARNING! Risk of Fire, Explosion or Electric Shock!
DO NOT use this appliance if any part has been under wa-
ter. Call a qualied service technician to inspect the appliance and to replace any part of the control system and/or
gas control which has been under water.
Hearth & Home Technologies • RBV4236/RBV4842 • 4048-210 • Rev AM • 02/2114