• Read, understand and follow
these instructions for safe
installation and operation.
1
• Important operating
and maintenance
instructions included.
Introduction
Table of Contents
1 Introduction
A. Introduction ....................................2
B. Approvals ...................................... 2
C. Operation ...................................... 2
D. Installation Guidelines ............................ 2
2 Framing
A. Framing .......................................7
B. Installing Vent Cap ...............................9
C. Connecting Insulated Flex Duct ....................13
3 Electrical Information
A. Wiring the Appliance for the Heat-Out-Primo ..........14
Installation of the HEAT-OUT-PRIMO may be done by a
qualied service technician only. Installation MUST comply with local, regional, state and national codes and regulations.
IMPORTANT: Failure to read and follow these instruc-
tions may create a possible hazard and will void the replace warranty.
These instructions must remain with the equipment.
1
Hearth & Home Technologies • HEAT-OUT-PRIMO Instructions • 2310-929 Rev. i • 1/19
DO NOT
DISCARD
• Leave this manual with
party responsible for use
and operation.
CAUTION! Risk of Cuts or Abrasions. Wear protective
gloves and safety glasses during installation. Sheet metal
edges are sharp.
CAUTION! Failure to install, operate, and maintain the
power venting system in accordance with manufacturer's
instructions will result in conditions which may produce
bodily injury and/or property damage.
NOTICE: The fan motors present in the HEAT-OUTPRIMO Powerow Heat Management System will generate sound during operation. The effects of the increased
sound level can be minimized with careful planning during
installation of the system.
WARNING! Risk of Fire! Either the HEAT-ZONE-PRIMO
or the HEAT-OUT-PRIMO Powerow Heat Management
system must remain ON during operation of the appliance. Overheating will occur. Appliance will shut down.
CAUTION! Risk of Shock! Disconnect electrical power from replace/power vent before performing any maintenance, repair, or electrical wiring.
A. Introduction
The HEAT-OUT-PRIMO PowerFlow Heat Management
system is designed to remove unwanted heat from your
home. The HEAT-OUT-PRIMO operates on 120VAC,
60Hz electrical services.
B. Approvals
The exible ducts used with the HEAT-OUT-PRIMO feature is manufactured and marked to the requirements of
UL-181, Class I air duct.
Note: Appliance will shut down if the HEAT-OUT-PRIMO
PowerFlow Heat Management system is not operating.
Contact your dealer if automatic shutdown occurs.
The Heat-Out feature is carefully engineered and must
be installed only as specied. If you modify it or any of its
components you will void the warranty, and you may possibly
cause a re hazard. Installation must be done according to
applicable local, state, provincial, and/or national codes.
D. Installation Guidelines
a. The exit termination of mechanical draft systems shall
not be less than seven feet above grade when located
adjacent to public walkways.
b.The bottom of the exterior cap must be a minimum of 12
in. (305mm) above nished grade.
c. The discharge outlet of the HEAT-OUT-PRIMO must be
directed down to prevent water inltration.
C. Operation
The HEAT-OUT-PRIMO accessory is tested and safe when
installed in accordance with this installation manual. It is
your responsibility to read all instructions before starting
installation and to follow these instructions carefully during
installation.
Installation of this kit MUST be performed by a qualied
service technician. After a qualied service technician has
installed the appliance, including the HEAT-OUT-PRIMO
PowerFlow Heat Management system, follow the instructions supplied with the appliance manual for operation.
Contact your dealer if you have questions.
Possible Air Duct Runs/Locations
Maximum Duct Run Length: 35 FT.
Minimum Duct Run Length: 36 IN.
Clearance to exible duct = 0
Other Duct Option
Metal Round And Oval Duct: A combination of 6" round
and 6" oval air duct can be used in the duct run. Metal
duct components may be purchased from an HVAC supplier.
Note: Support duct at intervals of no greater than 4 feet,
with no more than 1/2" sag between supports as required
by local code. Tape all seams with aluminum tape (1-1/4"
minimum width, or as specied by local codes).
*CAUTION! Risk of Overheating! Tape seams to pre-
vent overheating and shut down of appliance.
2
Hearth & Home Technologies • HEAT-OUT-PRIMO Instructions • 2310-929 Rev. i • 1/19
Preliminary Preparation
Contents of HEAT-OUT-PRIMO
CAUTION! Do not install damaged
components.
If any parts are missing or damaged, contact
your dealer before starting installation. DO NOT
install a damaged kit.
DESCRIPTIONSERVICE PART NO.QTY
6 in. Round Duct659-2001
Blower Base AssemblySRV4086-0211
Cover Assembly4086-0221
Unit Collar659-1251
Damper Assembly4086-3161
Wall Switch Plate2155-5111
Wall Switch2310-2101
**Vinyl Siding Shield4086-1401
*Fan AssemblyHEAT-OUT-UPG1
*Junction Box AssemblySRV2326-3041
*Included in Blower Base Assembly
**Not included with this kit.