Hearth & Home PRIMO72ST, PRIMO72, PRIMO60, PRIMO48ST, PRIMO60ST User Manual

...
For use on the following models:
PRIMO48 PRIMO48ST PRIMO60 PRIMO60ST PRIMO72 PRIMO72ST
HEAT-OUT-PRIMO
- Installation Instructions -
NOTICE
DO NOT DISCARD THIS MANUAL
• Read, understand and follow these instructions for safe installation and operation.
1
• Important operating and maintenance instructions included.
Introduction
Table of Contents
1 Introduction
A. Introduction ....................................2
B. Approvals ...................................... 2
C. Operation ...................................... 2
D. Installation Guidelines ............................ 2
2 Framing
A. Framing .......................................7
B. Installing Vent Cap ...............................9
C. Connecting Insulated Flex Duct ....................13
3 Electrical Information
A. Wiring the Appliance for the Heat-Out-Primo ..........14
Installation of the HEAT-OUT-PRIMO may be done by a qualied service technician only. Installation MUST com­ply with local, regional, state and national codes and reg­ulations.
IMPORTANT: Failure to read and follow these instruc-
tions may create a possible hazard and will void the re­place warranty.
These instructions must remain with the equipment.
1
Hearth & Home Technologies • HEAT-OUT-PRIMO Instructions • 2310-929 Rev. i • 1/19
DO NOT
DISCARD
CAUTION! Risk of Cuts or Abrasions. Wear protective gloves and safety glasses during installation. Sheet metal edges are sharp.
CAUTION! Failure to install, operate, and maintain the power venting system in accordance with manufacturer's instructions will result in conditions which may produce bodily injury and/or property damage.
NOTICE: The fan motors present in the HEAT-OUT­PRIMO Powerow Heat Management System will gener­ate sound during operation. The effects of the increased sound level can be minimized with careful planning during installation of the system.
WARNING! Risk of Fire! Either the HEAT-ZONE-PRIMO
or the HEAT-OUT-PRIMO Powerow Heat Management
system must remain ON during operation of the appli­ance. Overheating will occur. Appliance will shut down.
CAUTION! Risk of Shock! Disconnect electrical power from replace/power vent before performing any mainte­nance, repair, or electrical wiring.
A. Introduction
The HEAT-OUT-PRIMO PowerFlow Heat Management system is designed to remove unwanted heat from your home. The HEAT-OUT-PRIMO operates on 120VAC,
60Hz electrical services.
B. Approvals
The exible ducts used with the HEAT-OUT-PRIMO fea­ture is manufactured and marked to the requirements of
UL-181, Class I air duct.
Note: Appliance will shut down if the HEAT-OUT-PRIMO PowerFlow Heat Management system is not operating. Contact your dealer if automatic shutdown occurs.
The Heat-Out feature is carefully engineered and must
be installed only as specied. If you modify it or any of its
components you will void the warranty, and you may possibly
cause a re hazard. Installation must be done according to
applicable local, state, provincial, and/or national codes.
D. Installation Guidelines
a. The exit termination of mechanical draft systems shall
not be less than seven feet above grade when located adjacent to public walkways.
b.The bottom of the exterior cap must be a minimum of 12
in. (305mm) above nished grade.
c. The discharge outlet of the HEAT-OUT-PRIMO must be
directed down to prevent water inltration.
C. Operation
The HEAT-OUT-PRIMO accessory is tested and safe when installed in accordance with this installation manual. It is your responsibility to read all instructions before starting installation and to follow these instructions carefully during installation.
Installation of this kit MUST be performed by a qualied
service technician. After a qualied service technician has
installed the appliance, including the HEAT-OUT-PRIMO PowerFlow Heat Management system, follow the instruc­tions supplied with the appliance manual for operation. Contact your dealer if you have questions.
Possible Air Duct Runs/Locations
Maximum Duct Run Length: 35 FT. Minimum Duct Run Length: 36 IN.
Clearance to exible duct = 0
Other Duct Option
Metal Round And Oval Duct: A combination of 6" round
and 6" oval air duct can be used in the duct run. Metal duct components may be purchased from an HVAC sup­plier.
Note: Support duct at intervals of no greater than 4 feet,
with no more than 1/2" sag between supports as required by local code. Tape all seams with aluminum tape (1-1/4"
minimum width, or as specied by local codes).
*CAUTION! Risk of Overheating! Tape seams to pre- vent overheating and shut down of appliance.
2
Hearth & Home Technologies • HEAT-OUT-PRIMO Instructions • 2310-929 Rev. i • 1/19
Preliminary Preparation
Contents of HEAT-OUT-PRIMO
CAUTION! Do not install damaged components.
If any parts are missing or damaged, contact your dealer before starting installation. DO NOT install a damaged kit.
DESCRIPTION SERVICE PART NO. QTY
6 in. Round Duct 659-200 1
Blower Base Assembly SRV4086-021 1
Cover Assembly 4086-022 1
Unit Collar 659-125 1
Damper Assembly 4086-316 1
Wall Switch Plate 2155-511 1
Wall Switch 2310-210 1
**Vinyl Siding Shield 4086-140 1
*Fan Assembly HEAT-OUT-UPG 1
*Junction Box Assembly SRV2326-304 1
*Included in Blower Base Assembly **Not included with this kit.
659-200 6 Inch Round Duct
4086-022 Cover Assembly
SRV4086-021 Blower Base Assembly
Fan Assembly - Order HEAT-OUT-UPG
659-125 Unit Collar
SRV2326-304 Junction Box Assembly
2155-511 Wall Switch Plate4086-316 Damper Assembly
NOTICE: Install vinyl siding heat shield only with vinyl siding.
2310-210 Wall Switch
3
4086-140 Vinyl Siding Shield
Hearth & Home Technologies • HEAT-OUT-PRIMO Instructions • 2310-929 Rev. i • 1/19
*
Heat-Out-Primo
HEAT-OUT-PRIMO Feature - Configuration
* = Optional HEAT-OUT-PRIMO location
X = Not for HEAT-OUT-PRIMO
WARNING! Risk of Overheating! Damper MUST be installed with crimped side up. Damper will not function properly.
WARNING! Risk of Fire! Verify damper is opera­tional. Overheating will occur if damper does not open and close.
Heat-Out-Primo Only
**ATTACH WITH ZIP TIE AT DAMPER
Heat-Out-Primo
***DAMPER
*
Collar
LED Color Switch
*The Heat-Out-Primo may be installed in either position shown above.
*Note: Remove only one of the two Heat-Out seal plates if installing the HEAT-OUT-PRIMO. The other plate must remain installed.
** Use included zip ties to attach the flex duct to the damper. ***Verify damper is operational and no obstructions, such as screws, are present.
4
Hearth & Home Technologies • HEAT-OUT-PRIMO Instructions • 2310-929 Rev. i • 1/19
Heat-Zone-Primo
Heat-Out-Primo
***DAMPER
Heat-Zone-Primo CollarHeat-Zone-Primo Collar
Wall Switch
HEAT-ZONE-PRIMO & PowerFlow Heat Management Toggle
LED COLOR SWITCHES
**ATTACH WITH ZIP TIE AT DAMPER
Heat-Zone-Primo
HEAT-OUT COLLAR
*The Heat-Out-Primo may be installed in either position shown above.
** Use included zip ties to attach the flex duct to the damper. *** Verify damper is operational and no obstructions, such as screws, are present.
*Note: Remove only one of the two Heat-Out seal plates if installing the HEAT-OUT-PRIMO. The other plate must remain installed.
*
HEAT- O UT-PRIMO Incorporated with HEAT-ZONE-PRIMO
Heat-Out-Primo
*
* = Optional HEAT-OUT-PRIMO location
X = Not for HEAT-OUT-PRIMO
WARNING! Risk of Overheating! Damper MUST be installed with crimped side up. Damper will not function properly.
WARNING! Risk of Fire! Verify damper is opera­tional. Overheating will occur if damper does not open and close.
5
Hearth & Home Technologies • HEAT-OUT-PRIMO Instructions • 2310-929 Rev. i • 1/19
Power Vent Termination Clearances
PV = PVLP-SLP HO = HEAT-OUT-PRIMO
1/2 IN. MIN. TO SOFFIT
HO
HO
PV
PV
24 IN. MIN.24 IN. MIN.
HO
HOPV
6 IN. MIN.
HO
12 IN. MIN.
GRADE
6
Hearth & Home Technologies • HEAT-OUT-PRIMO Instructions • 2310-929 Rev. i • 1/19