Hearth Home PH-FRT-LINEAR, PH-SIDE-LINEAR, COSMO-IFT-B, RAVE-IFT-B, JADE-B Installation Manual

...
PH-FRT-LINEAR, PH-SIDE-LINEAR
Models: COSMO-IFT-B Series, RAVE-IFT-B Series, JADE-B, DVLINEAR36, B41IL-AU Series
Passive Heat Kit Installation Instructions
Leave this manual with party responsible for use and operation.
CAUTION! Risk of Cuts, Abrasions or Flying Debris.
CAUTION! Do not install damaged components.
If any parts are missing or damaged, contact your dealer before starting installation. DO NOT install a damaged kit.
DANGER
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and must be installed for the protection of children and other at-risk individuals.
Table of Contents
Introduction ....................................... 1
Preparation .......................................1
Kit Contents ....................................... 2
Clearances .......................................3
Good Faith TV Guidelines ............................4
Framing Dimensions- Passive Heat Front Discharge
(PH-FRT-LINEAR) ...............................5
Framing Dimensions - Passive Heat Side Discharge
(PH-SIDE-LINEAR) .............................. 6
Framing Dimensions - Passive Heat Open Top
Discharge (PH-FRT-LINEAR) .......................7
Adapter Installation - Front, Side and Open Top Discharge .. 8
Passive Heat Template - Front and Side Discharge ........ 8
Register Cover Installation - Side Discharge ............. 9
Finishing ........................................ 10
Mantel Projections ................................. 12
Installation of Passive Heat with Other Optional Heat
Management Systems ...........................12
Maintenance .....................................12
Introduction
The Passive Heat (PH-FRT-LINEAR, PH-SIDE-LINEAR) Heat Management System conveys warm air from the replace into the same room through either one front dis­charge slot, two side discharge heat registers or an open top discharge.
Installation of the Passive Heat kit must be done in con­junction with the appliance installation. Installation of this kit MUST be performed by a qualied service technician.
WARNING! Risk of Fire! DO NOT install the Passive Heat (PH-FRT-LINEAR or PH-SIDE-LINEAR) Heat Man­agement System with models that are not approved. Overheating will occur.
The Passive Heat Trim Kit is also available for installation with the Front Discharge Passive Heat systems and must be purchased separately. Contact your dealer to order the appropriate kit: PHTRIM-32LINEAR, PHTRIM-36LINEAR
or PHTRIM-42LINEAR.
Follow instructions included with the trim kit to complete installation of the Passive Heat system.
The Passive Heat kit is tested and safe when installed in accordance with this installation manual. It is your respon­sibility to read all instructions before starting installation and to follow these instructions carefully during installation.
The Passive Heat kit is carefully engineered and must
be installed only as specied. If you modify it or any of
its components you will void the warranty, and you may
possibly cause a re hazard. Installation must be done
according to applicable local, state, provincial, and/or national codes.
Preparation
Plan the location of the appliance.
Determine whether front, open top or side discharge is to be installed and follow instructions for the appropriate application.
CAUTION! Risk of Burns!
• The replace should be turned o and cooled before
kit is installed.
• Shut o gas supply.
Hearth & Home Technologies • PH-FRT-LINEAR, PH-SIDE-LINEAR Instructions • 2616-970 Rev. G • 3/21
1
Power Vent Option
If an optional power vent will be installed in conjunction with the Passive Heat Kit (PH-FRT-LINEAR or PH-SIDE­LINEAR), Hearth & Home Technologies recommends the PVLP-SLP power vent option. If the application does not allow for the PVLP-SLP to be used, the PVI-SLP-B may be used. The PVI-SLP-B must be mounted outside the chase due to the higher noise level created.
The Passive Heat Kit is not compatible with a Smart­Wall™ TV Kit , GFK-160A, GFK-240 or other fan.
For AU models, PVLP-SLP-AU is approved to be used in conjunction with the Passive Heat Kit.
Kit Contents
Verify and remove contents from packaging before beginning installation. See Figure 1 (Front or Open Top Discharge) or Figure 2 (Side Discharge).
Contents of Front/Open Top Discharge Kit
PH-FRT-LINEAR
FRONT/OPEN TOP DISCHARGE KIT
DESCRIPTION SERVICE PART NO. QTY
Passive Heat Adapter 2617-302 2
Screw 030-860/8 1
Passive Heat Template 2617-137 2
Contents of Side Discharge Kit
PH-SIDE-LINEAR
SIDE DISCHARGE KIT (PH-SIDE-LINEAR)
DESCRIPTION SERVICE PART NO. QTY
Register Cover 2560-120 2
Passive Heat Adapter 2617-302 2
Screw 030-860/8 1
Passive Heat Template 2617-137 4
030-860/8
Screw 2560-120 12 in. x 8 in. (305 mm x 203 mm) Register Cover (Quantity 2, Includes Screws)
2617-302 Passive Heat Adapter
030-860/8 Screw
2617-137 Passive Heat Template
Figure 1 Front/Open Top Discharge Passive Heat Kit Components
2
Hearth & Home Technologies • PH-FRT-LINEAR, PH-SIDE-LINEAR Instructions • 2616-970 Rev. G • 3/21
2617-302 Passive Heat Adapter
Figure 2 Side Discharge Passive Heat Kit Components
2617-137 Passive Heat Template
Clearances
Clearance - Sprinkler to Passive Heat
WARNING! Risk of Fire! Maintain clearances to
combustibles as specied.
Ensure all clearances are maintained.
• Maintain minimum distance from top of appliance
opening to the room ceiling. Refer to the gures in the
Framing section of this instruction.
• An open space, or “cavity,” is allowed up to three inches above the top of the passive heat discharge opening. A chase ceiling is required when the open space “cavity” exceeds three inches above the discharge opening. Construct the false ceiling from material such as metal, drywall or plywood.
Figure 3 references the clearances that must be adhered to when installing a sprinkler head near a passive heat discharge opening.
* If the distance from the top of the passive heat front
discharge opening to the ceiling is 36 in. (914 mm) or greater, then there is no 36 in. (914 mm) clearance requirement. This is for a ceiling sprinkler head installation only.
Note: When installing a sprinkler head near a heat
discharge opening, it is recommended to use a sprinkler head with an Extra High sprinkler activation temperature rating.
• When installing a sprinkler head exterior of the chase, maintain the following clearances to discharge openings (convection slots, passive heat registers, heat zone registers, etc.): 36 in. (914 mm) top, 18 in. (457 mm) sides and 6 in. (152 mm) bottom.
DO NOT install a sprinkler head inside a chase that is set up for passive heat.
PASSIVE HEAT FRONT DISCHARGE OPENING (Clearances for front and side discharge installations)
CEILING
36 IN.
(914 mm)
18 IN.
(457 mm)
*
36 IN.
(914 mm)
6 IN.
(15 mm)
INTERIOR WALL
18 IN.
(457 mm)
FIREPLACE
FLOOR
= SPRINKLER HEAD
PASSIVE HEAT OPEN TOP DISCHARGE OPENING
CEILING
36 IN.
(914 mm)
6 IN.
(15 mm)
INTERIOR WALL
Figure 3
Hearth & Home Technologies • PH-FRT-LINEAR, PH-SIDE-LINEAR Instructions • 2616-970 Rev. G • 3/21
3
Good Faith TV Guidelines
WARNING! Risk of Fire! Mesh screen required on bottom of discharge opening when discharge opening is greater than 3 in. (76 mm). Secure mesh to top of framing.
Good Faith Guidelines for TV Installations Above a Fireplace with Passive Heat Option
This diagram specific to these models:
COSMO32-IFT-B RAVE32-IFT-B JADE32IN-B COSMO36-IFT-B RAVE36-IFT-B JADE42IN-B COSMO42-IFT-B RAVE42-IFT-B JADE42IL-B DVLINEAR36 B41L-AU
ROOM CEILING
71-7/8 IN. (1826 mm) MIN. (Appliance may be installed off of floor)
77-3/8 IN. (1965 mm) MIN. (Appliance may be installed off of floor)
4 IN. MIN.
(102 mm)
SEE FIGURES 5, 6 and 7
(MINIMUM CLEAR ANCE TO
DISCHARGE OPENING)
TV
12 IN. MIN.
(305 mm)
1-1/2 IN. (2 X 4 FRAMING)
2 IN. MIN.
(51 mm)
1/2 IN. X 1/2 IN. (51 mm x 51 mm) WIRE MESH*
2 X 4 FRAMING
(90 x 35 mm for AU)
2 X 4 OR 2 X 6
(90 x 35 mm for AU)
FRAMING
(90 x 35 mm for AU)
CHASE CEILING - SEE FIGURES 5 and 6 (FRONT AND SIDE DISCHARGE ONLY)
WIRE MESH*
= PASSIVE HEAT DISCHARGE OPENING
FIREPLACE
OPENING
Figure 4
4
Measurement from top edge of opening to bottom of appliance = 25-7/8 IN. (657 mm)
* Wire mesh required for front discharge or open top discharge passive heat installations with discharge
opening of 3 in. (76 mm) or greater.
NOTE: The TV installation requirements are the same regardless of whether the Passive Heat kit is installed with a top discharge, side discharge or open top discharge.
Hearth & Home Technologies • PH-FRT-LINEAR, PH-SIDE-LINEAR Instructions • 2616-970 Rev. G • 3/21