Hearth and Home Technologies WTBC42DB, WTBC36BB, WTBC36DB, WTBC42BB User Manual

INSTALLATION INSTRUCTIONS
REFRACTORIES FOR CB & CD SERIES
WTBC36BB and WTBC42BB - B-vent Refractory WTBC36DB and WTBC42DB - Direct Vent Refractory
These refractories are intended for use with the Caliber CB Series B-Vent and CD Series Direct Vent gas appliances. Refer to the installa­tion instructions supplied with the appliance for the correct accessories to be used. If you encounter any problems regarding code approv­als or if you need clarifi cation of the instructions contained here, contact your local distributor/dealer or the Heatilator Technical Services Department, Hearth & Home Technologies Inc., 1915 W. Saunders Street, Mt. Pleasant, IA 52641, phone 1-800-927-6841.
CAUTION:
Install this refractory only after the appliance has cooled and the gas and electricity have been shut off.
Note: An arrow () found in the text signifi es change in content.
Wear gloves and safety glasses for protection.
CAUTION:
12/05 4040-227 Rev B 1
REFRACTORY - CB & CD SERIES INSTALLATION INSTRUCTIONS
1. Shut off the electricity to the appliance and turn the gas shutoff
valve to the closed position. See Figure 1. Remove the screen and glass from the appliance.
OFF
Figure 1 - Gas Shutoff Valve
2. Lift the two top logs off the log set. See Figure 2.
3. Remove the grate/log assembly by removing the two screws
as shown in Figure 2. Lift and pull the grate/log assembly from the front of the fi rebox.
Remove four screws securing the rear log. See Figure 3. Lift
rear log and remove from fi rebox.
Figure 3 - Remove Rear Log
4. Carefully install a side refractory. Tip the bottom edge into posi-
tion, and swing the top up. This will hold the back refractory in place. See Figure 4.
Figure 4 - Tip Side Refractory
5. To secure the side refractory in place, remove the screw in
the fi rebox side. Attach a refractory bracket (using the screw
Screws
removed) to the fi rebox side. Leave screw loose until Step 7 to allow for adjusting. See Figure 5.
Figure 2 - Loosen Grate
Figure 5 - Refractory Brackets
2 4040-227 Rev B 12/05
Loading...
+ 2 hidden pages