• Important operating
and maintenance
instructions included.
WARNING: If the information in these
instructions is not followed exactly, a fi re
or explosion may result causing property
damage, personal injury, or death.
• DO NOT store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency , or the
gas supplier.
This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must be
installed in accordance with the manufacturer’s instructions
and the manufactured home construction and safety standard,
Title 24 CFR, Part 3280 or Standard for Installation in Mobile
Homes, CAN/CSA Z240MH, in Canada.
This appliance is only for use with the type(s) of gas indicated
on the rating plate.
• Read, understand and follow
these instructions for safe
installation and operation.
DO NOT
DISCARD
• Leave this manual with
party responsible for use
and operation.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• DO NOT touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fi replace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other fl ammable
materials.
• Keep clothing, furniture, draperies and other fl ammable
materials away.
This appliance has been supplied with an integral barrier
to prevent direct contact with the fi xed glass panel. DO
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fi tter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
Installation and service of this appliance should be
performed by qualifi ed personnel. Hearth & Home
Technologies suggests NFI certifi ed or factory trained
professionals, or technicians supervised by an NFI
certifi ed professional.
Read this manual before installing or operating this appliance.
Please retain this owner’s manual for future reference.
A. Congratulations
Congratulations on selecting a Heat & Glo LifeStyle gas
fi replace, an elegant and clean alternative to wood burning
fi replaces. The Heat & Glo LifeStyle gas fi replace you
have selected is designed to provide the utmost in safety ,
reliability, and effi ciency.
As the owner of a new fi replace, you’ll want to read and
carefully follow all of the instructions contained in this
owner’s manual. Pay special attention to all cautions and
This owner’s manual should be retained for future
reference. We suggest that you keep it with your other
important documents and product manuals.
The information contained in this owner’s manual, unless
noted otherwise, applies to all models and gas control
systems.
Your new Heat & Glo LifeStyle gas fi replace will give you
years of durable use and trouble-free enjoyment. Welcome
to the Heat & Glo LifeStyle family of fi replace products!
warnings.
Homeowner Reference Information
We recommend that you record the following pertinent
information about your fi replace.
Model Name: ___________________________________________ Date purchased/installed: __________________
Serial Number: __________________________________________ Location on fi replace: _____________________
Dealership purchased from: _______________________________ Dealer Phone: __________________________
Notes: _______________________________________________________________________________________
_____________________________________________________________________________________________
Listing Label Information/Location
This product may be covered by one or more of the following patents: (Nos produits sont couverts par un ou plusieurs des brevets suivants): (United States)
4593510,4686807, 4766876, 4793322, 4811534, 5000162, 5016609, 5076254, 5113843, 5191877, 5218953, 5263471, 5328356,5341794, 5347983,5429495,
5452708,5542407, 5601073, 5613487, 5647340, 5688568, 5762062, 5775408, 5890485,5931661, 5941237,594711 2,5996575, 6006743, 6019099, 6048195,
6053165, 6145502, 6170481, 6237588, 6296474, 6374822, 6413079, 6439226, 6484712, 6543698, 6550687, 6601579, 6672860, 6688302B2, 6715724B2,
6729551, 6736133, 6748940, 6748942, D320652, D445174, D462436; (Canada)1297749, 2195264, 2225408; or other U.S. and foreign patents pending (ou
autresbrevetsamericainsetetrangersenattente).
Type of Gas
Not for use with solid fuel .
(Ne doit pas entre utilise avec un combustible solide).
Ty pe of Gas (Sorte De Gaz) :
NATURA L GAS
Gas and Electric
Information
Minimum Permissible Gas Supply for Purpos es of Input Adjustment .
Approved Minimum (De Gaz) Acceptabl e 0. 0 in w. c.(Po. Col. d’eau) Maximum Pressure (Pression) 0. 0 in w. c.(Po. Col. d’eau) Maximum Manifold Pressure (Pression) 0. 0 in w. c. (Po. Col. d’eau) Minimum Manifold Pressure (Pression) 0. 0 in w. c. (Po. Col. d’eau)
T o tal Electrical Requirements: 000V ac, 00Hz., less than 00 Ampere s
AL TI TUDE :0-0000 FT . 0000-0000FT .
MAX. INPU T BTUH: 00,000 00,000
MIN. INPU T BTUH: 00,000 00,000
ORIFICE SIZE: #XXXXX #XXXXX
The model information regarding your specifi c fi replace can be found on
the rating plate usually located in the control area of the fi replace.
He at & Gl o, a of Hearth & Ho me Te chnologies, Inc.
20802 Kensington Boulevard, Lakeville, MN 5504 4
This appliance must be installed in accordance with local codes, if any; if not, follow ANSI Z223.1
in the USA or CAN/CG A B149 installation codes. (Installer l’ appa re il selon les codes ou regl emen ts
lo caux ou , en l’absence de tels reglements, selon les codes d’in stallation CAN/CGA-B149.)
B. Limited Lifetime Warranty
Hearth & Home Technologies LIMITED WARRANTY
Hearth & Home Technologies (“HHT”) and its respective brands extends the following warranty for HHT gas, wood, pellet
and electric appliances purchased from an authorized HHT dealer and installed in the United States of America or Canada.
Warranty starts with date of purchase by the original owner (End User) except as noted for replacement parts.
Warranty PeriodHHT Manufactured Appliances and Venting
PartsLaborGasWoodPellet
1 YearXXXXXX
EPA
Wood
ElectricVenting
Components Covered
All Parts and Material Except as
covered by Conditions, Exclusion,
and Limitations listed
XX
2 years
3 yearsXFirepots
5 years3 yearsXXCastings & Baffl es
7 years3 yearsXXX
10 years1 yearXBurners, Logs & Refractory
Limited
Lifetime
1 yearXFirebox & Heat Exchanger
90 DaysXXXXXX All Replacement Parts
XXXXBlowers
XMolded Refractory Panels
Igniters, Electronic Components,
and Glass
Firebox, HHT Chimney,
Termination & Heat
Exchanger
See Conditions, Exclusions, and limitations. 9-01-08
CONDITIONS, EXCLUSIONS & LIMITATION OF LIABILITY
• This warranty applies to the original owner and is transferable up to two years from date of purchase to the new homeowner,
provided the purchase was made through an authorized dealer or distributor of HHT, and the appliance remains in its
original place of installation.
• The maximum amount recoverable under this warranty is limited to the purchase price of the product.
• In no event shall HHT be liable for any incidental or consequential damages caused by defects in the product.
• Adjustments, regular maintenance, cleaning and temporary repairs, or the failure to duplicate the problem in the home is
not covered under this warranty.
• This limited warranty does not extend to or include surface fi nish on the appliance or terminations, door gasketing, glass
gasketing, glass discoloration, fi rebrick, pellet logs, kaowool or other ceramic insulating materials. Rust and/or corrosion
on any of the metal surfaces, cast iron components, baffl es, fi repots, doors, or fi rebox area are not covered by this
warranty.
• Noise resulting from minor expansion, contraction, or movement of certain parts is normal and complaints related to this
noise are not covered by this warranty.
• HHT’s obligation under this warranty does not extend to damages resulting from: (1) installation, operation or maintenance
of the appliance not in accordance with the installation instructions; operating instructions and the listing agent identifi cation
label furnished with the appliance; (2) installation which does not comply with local building codes; (3) shipping, improper
handling, improper operation, abuse, misuse, accident or unworkmanlike repairs; (4) environmental conditions, inadequate
ventilation or drafting caused by tight sealing construction of the structure or handling devices such as exhaust fans or forced
air furnaces or other such causes; (5) use of fuels other than those specifi ed in the operating instructions; (6) installation
or use of components not supplied with the appliance or any other components not expressly authorized and approved
by HHT; and/or (7) modifi cation of the appliance not expressly authorized and approved by HHT in writing.
• This warranty does not apply to non-HHT venting components, hearth components or other accessories used in conjunction
with the installation of this product.
• This warranty is void if the appliance has been over-fi red or operated in atmospheres contaminated by chlorine, fl uorine,
or other damaging chemicals the appliance is subject to prolonged periods of dampness or condensation, or there is any
damage to the appliance or other components due to water or weather damage which is the result of, but not limited to,
improper chimney or venting installation.
• HHT’s liability under this warranty is limited to the replacement and repair of defective components or workmanship during
the applicable period. HHT may fully discharge all of its obligations under such warranties by repairing the defective
component(s) at HHT’s discretion. Shipping costs are not covered under this warranty.
• Some states do not allow exclusions or limitation of incidental or consequential damages, so those limitations may not
apply to you. This warranty gives you specifi c rights; you may also have other rights, which vary from state to state.
• EXCEPT TO THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE
WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF
THE WARRANTY SPECIFIED ABOVE.
This Limited Warranty is effective on all HHT appliances sold after September 01, 2008 and supersedes any and all
warranties currently in existence.
If warranty service is needed, you should contact your installing dealer. If the installing dealer is unable to provide necessary
parts or components, contact the nearest authorized HHT dealer or supplier.
MODEL: Twilight-II-B
LABORATORY: Underwriters Laboratories, Inc. (UL)
TYPE: Direct Vent Gas Appliance
STANDARD: ANSI Z21.50-2003 • CSA2.22-M03 • UL307B
This product is listed to ANSI standards for “Vented Gas
Appliance Heaters” and applicable sections of “Gas Burning Heating Appliances for Manufactured Homes and
Recreational Vehicles”, and “Gas Fired Appliances for
Use at High Altitudes”.
NOTICE: This installation must conform with local codes.
In the absence of local codes you must comply with the
National Fuel Gas Code, ANSI Z223.1-latest edition in
the U.S.A. and the CAN/CGA B149 Installation Codes in
Canada.
NOT INTENDED FOR USE AS A PRIMAR Y HEAT SOURCE.
This appliance is tested and approved as either supplemental room heat or as a decorative appliance. It should not be
factored as primary heat in residential heating calculations.
B. Tempered Glass Specifi cations
Hearth & Home Technologies appliances manufactured
with tempered glass may be installed in hazardous locations such as bathtub enclosures as defi ned by the Con-
sumer Product Safety Commission (CPSC). The tempered
glass has been tested and certifi ed to the requirements
of ANSI Z97.1 and CPSC 16 CFR 1202 (Safety Glazing
Certifi cation Council SGCC# 1595 and 1597. Architectur-
al Testing, Inc. Reports 02-31919.01 and 02-31917.01).
This statement is in compliance with CPSC 16 CFR Sec-tion 1201.5 “Certifi cation and labeling requirements”
which refers to 15 U.S. Code (USC) 2063 stating “…Such
certifi cate shall accompany the product or shall otherwise
be furnished to any distributor or retailer to whom the
product is delivered.”
Some local building codes require the use of tempered
glass with permanent marking in such locations. Glass
meeting this requirement is available from the factory.
Please contact your dealer or distributor to order.
D. Air Infi ltration, Water Resistance and
Structural Tests
he Hearth & Home Technologies Twilight-II-B Indoor/
T
Outdoor Appliance unit was tested to the following ASTM
standards at the Stork Twin City Testing laboratory.
Air infi ltration test ASTM:E283-(04). The sample was test-
ed at 1.57 psf (equivalent to a 25-mph windload). Water
resistance test ASTM:E331-00. The test specimen was
tested at the requested test pressures of 8.0 & 25.0 psf.
Structural test ASTM:E330-02. The unit was tested to a
design pressure of 50-psf, a test pressure of 75-psf.
NOTICE: If the heating value of the gas has been reduced,
these rules do not apply. Check with your local gas utility
or authorities having jurisdiction.
When installing above 2000 feet elevation:
• In the USA: Reduce input rate 4% for each 1000 feet
above 2000 feet.
• In CANADA: Reduce input rate 10% for elevations
between 2000 feet and 4500 feet. Above 4500 feet,
consult local gas utility.
Check with your local gas utility to determine proper
orifi ce size.
E. Non-Combustible Materials Specifi cation
Material which will not ignite and burn. Such materials are
those consisting entirely of steel, iron, brick, tile, concrete,
slate, glass or plasters, or any combination thereof.
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in a
Vertical Tube Furnace at 750 ºC and UL763 shall be
considered non-combustible materials.
F. Combustible Materials Specifi cation
Materials made of or surfaced with wood, compressed paper, plant fi bers, plastics, or other material that can ignite
and burn, whether fl ame proofed or not, or plastered or
unplastered shall be considered combustible materials.
G. Electrical Codes
NOTICE: This appliance must be electrically wired and
grounded in accordance with local codes or, in the absence
of local codes, with National Electric Code ANSI/NFPA
70-latest edition or the Canadian Electric Code CSA
C22.1.
• A 110-120 VAC circuit for this product must be protected
with ground-fault circuit-interrupter protection, in compliance
with the applicable electrical codes, when it is installed in
locations such as in bathrooms or near sinks.
Note: The following requirements reference various
Massachuset ts and national codes not contained in this
document.
H. Requirements for the Commonwealth of
Massachusetts
For all side wall horizontally vented gas fueled equipment
installed in every dwelling, building or structure used in
whole or in part for residential purposes, including those
owned or operated by the Commonwealth and where the
side wall exhaust vent termination is less than seven (7)
feet above fi nished grade in the area of the venting, in-
cluding but not limited to decks and porches, the following
requirements shall be satisfi ed:
Installation of Carbon Monoxide Detectors
At the time of installation of the side wall horizontal vented
gas fueled equipment, the installing plumber or gas fi tter
shall observe that a hard wired carbon monoxide detector
with an alarm and battery back-up is installed on the fl oor
level where the gas equipment is to be installed. In addition, the installing plumber or gas fi tter shall observe that
a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of
the dwelling, building or structure served by the side wall
horizontal vented gas fueled equipment. It shall be the
responsibility of the property owner to secure the services
of qualifi ed licensed professionals for the installation of
hard wired carbon monoxide detectors.
In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic,
the hard wired carbon monoxide detector with alarm and
battery back-up may be installed on the next adjacent
fl oor level.
In the event that the requirements of this subdivision can
not be met at the time of completion of installation, the
owner shall have a period of thirty (30) days to comply
with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon
monoxide detector with an alarm shall be installed.
Inspection
The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the
installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed
in accordance with the provisions of 248 CMR 5.08(2)(a)1
through 4.
Exemptions
The following equipment is exempt from 248 CMR
5.08(2)(a)1 through 4:
• The equipment listed in Chapter 10 entitled “Equipment
Not Required To Be Vented” in the most current edition
of NFPA 54 as adopted by the Board; and
• Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate
from the dwelling, building or structure used in whole or
in part for residential purposes.
MANUFACTURER REQUIREMENTS
Gas Equipment Venting System Provided
When the manufacturer of Product Approved side wall
horizontally vented gas equipment provides a venting
system design or venting system components with the
equipment, the instructions provided by the manufacturer
for installation of the equipment and the venting system
shall include:
• Detailed instructions for the installation of the venting
system design or the venting system components; and
• A complete parts list for the venting system design or
venting system.
Gas Equipment Venting System NOT Provided
When the manufacturer of a Product Approved side wall
horizontally vented gas fueled equipment does not provide the parts for venting the fl ue gases, but identifi es
“special venting systems”, the following requirements
shall be satisfi ed by the manufacturer:
Approved Carbon Monoxide Detectors
Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA
720 and be ANSI/UL 2034 listed and IAS certifi ed.
Signage
A metal or plastic identifi cation plate shall be permanent-
ly mounted to the exterior of the building at a minimum
height of eight (8) feet above grade directly in line with the
exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read,
in print size no less than one-half (1/2) in. in size, “GAS
VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”.
• The referenced “special venting system” instructions
shall be included with the appliance or equipment installation instructions; and
• The “special venting systems” shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation
instructions.
A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting
instructions, and/or all venting design instructions shall
remain with the appliance or equipment at the completion
of the installation.
See Gas Connection section for additional Commonwealth of Massachusetts requirements.
2
2
Operating Instructions
User Guide
A. Gas Fireplace Safety
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• DO NOT touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fi replace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other
fl ammable materials.
• Keep clothing, furniture, draperies and other fl ammable
materials away.
This appliance has been supplied with an integral barrier
to prevent direct contact with the fi xed glass panel. DO
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
If you expect that small children or vulnerable adults may
come into contact with this fi replace, the following precau-
tions are recommended:
• Install a physical barrier such as:
- A decorative fi rescreen.
- Adjustable safety gate.
• Install a switch lock or a wall/remote control with child
protection lockout feature.
• Keep remote controls out of reach of children.
• Never leave children alone near a hot fi replace, whether
operating or cooling down.
• Teach children to NEVER touch the fi replace.
• Consider not using the fi replace when children will be
present.
Contact your dealer for more information, or visit: www.
hpba.org/staysafe.
T o prevent unintended operation when not using your fi re-
place for an extended period of time (summer months,
vacations, trips, etc):
• Remove batteries from remote controls.
• Turn off wall controls.
• Unplug 3 volt adapter plug and remove batteries on IPI
models.
• Turn off gas controls valve on standing pilot models.
When lighting the pilot light on fi replaces with a standing
pilot, remove the fi xed glass assembly so you can de-
tect presence of residual gas build-up. See Standing Pilot
Lighting instructions and Maintenance Tasks.
B. Your Fireplace
WARNING! DO NOT operate fi replace before read-
ing and understanding operating instructions. Failure
to operate fi replace according to operating instructions
could cause fi re or injury.
If desired, a fan kit may be added. Contact your dealer to
order the correct fan kit.
D. Clear Space
WARNING! DO NOT place combustible objects in front
of the fi replace or block louvers. High temperatures may
start a fi re. See Figure 2.2.
A void placing candles and other heat-sensitive objects on
mantel or hearth. Heat may damage these objects.
3 FT. IN FRONT OF FIREPLACE
CLE
AR SPACE
Figure 2.2 Clear Space
E. Decorative Doors and Fronts
WARNING! Risk of Fire! Install ONLY doors or fronts
approved by Hearth & Home Technologies. Unapproved
doors or fronts may cause fi replace to overheat.
This fireplace has been supplied with an integral
barrier to prevent direct contact with the fi xed glass
panel. DO NOT operate the fi replace with the barrier
removed.
Contact your dealer or Hearth & Home Technologies if
the barrier is not present or help is needed to properly
install one.
F. Fixed Glass Assembly
See Section 11.G.
G. Remote Controls, Wall Controls and Wall
Switches
Follow the instructions supplied with the control installed
to operate your fi replace:
For safety:
• Install a switch lock or a wall/remote control with child
protection lockout feature.
• Keep remote controls out of reach of children.
See your dealer if you have questions.
H. Before Lighting Fireplace
Before operating this fi replace for the fi rst time, have a
qualifi ed service technician:
• Verify all shipping materials have been removed from
inside and/or underneath the fi rebox.
• Review proper placement of logs, ember material and/or
other decorative materials.
• Check the wiring.
• Check the air shutter adjustment.
• Ensure that there are no gas leaks.
• Ensure that the glass is sealed and in the proper position
and that the integral barrier is in place.
WARNING! Risk of Fire or Asphyxiation! DO NOT operate fi replace with fi xed glass assembly removed.
Determine if this fi replace has a standing pilot or an
Intellifi re ignition system. Ask your dealer or open control
access panel, look at gas valve assembly.
• An Intellifi re ignition system will not have a button.
For more information refer to the instructions supplied with
your decorative door or front.
The IPI system may be operated with two D-cell batteries. When using batteries, unplug the transformer. To prolong battery
life, remove them when using the transformer.
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fi re or explosion
may result causing property damage, personal injury or loss of life.
A. This appliance is equipped with an
intermittent pilot ignition (IPI) device
which automatically lights the burner. DO NOT try to light the burner by
hand.
B.BEFORE LIGHTING, smell all around
the appliance area for gas. Be sure to
smell next to the fl oor because some
gas is heavier than air and will settle
on the fl oor.
WHA T TO DO IF YOU SMELL GAS
• DO NOT try to light any appliance.
• DO NOT touch any electric switch; do
not use any phone in your building.
WARNING:
DO NOT CONNECT 110 VAC TO
THE CONTROL VALVE.
Improper installation, adjustment, alteration, service or maintenance can
cause injury or property damage. Refer to the owner’s information manual
provided with this appliance.
This appliance needs fresh air for
safe operation and must be installed
so there are provisions for adequate
combustion and ventilation air.
If not installed, operated, and maintained in accordance with the manufacturer’s instructions, this product
could expose you to substances in fuel
or fuel combustion which are known to
the State of California to cause cancer, birth defects, or other reproductive
harm.
Keep burner and control compartment
clean. See installation and operating
instructions accompanying appliance.
• Immediately call your gas supplier
from a neighbor’s phone. Follow the
gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fi re department.
C. DO NOT use this appliance if any
part has been under water. Immediately call a qualifi ed service tech-
nician to inspect the appliance and
to replace any part of the control
system and any gas control which
has been under water.
CAUTION:
Hot while in operation. DO NOT touch.
Keep children, clothing, furniture, gasoline and other liquids having fl ammable
vapors away.
DO NOT operate the appliance with
fi xed glass assembly removed, cracked
or broken. Replacement of the fi xed
glass assembly should be done by a
licensed or qualifi ed service person.
NOT FOR USE
WITH SOLID FUEL
For use with natural gas and propane.
A conversion kit, as supplied by the
manufacturer, shall be used to convert
this appliance to the alternate fuel.
Also Certifi ed for Installation in a
Bedroom or a Bedsitting Room.
For assistance or additional information, consult a qualifi ed installer, ser-
vice agency or the gas supplier.
LIGHTING
INSTRUCTIONS
(IPI)
1. Turn off all electric power to the appliance.
2. This appliance is equipped with an ignition
device which automatically lights the burner.
DO NOT try to light the burner by hand.
GAS
VALVE
3. Wait fi ve (5) minutes to clear out any gas.
Then smell for gas, including near the fl oor. If
you smell gas, STOP! Follow “B” in the Safety
Information located on the left side of this label. If you do not smell gas, go to next step.
4. Turn on all electric power to the appliance.
5. To light the burner, fl ip the ON/OFF switch to
the “ON” position. (The ON/OFF switch may
include a wall switch if so equipped).
6. If the appliance will not operate, follow the instructions “To Turn Off Gas to Appliance” and
call your service technician or gas supplier.
TO TURN OFF
GAS TO APPLIANCE
1. Turn wall control or ON/OFF switch to “OFF”.
2. Turn off all electric power to the appliance if
service is to be performed.
593-913F
Hearth & Home Technologies fi replace, please refer to www.fi replaces.com.
• The fi replace should be run three to four hours continu-
ously on high.
• Turn the fi replace off and allow it to completely cool.
• Remove fi xed glass assembly. See Section 11.G.
• Clean fi xed glass assembly. See Section 3.
• Replace the fi xed glass assembly and run continuously
on high an additional 12 hours.
This cures the materials used to manufacture the fi re-
place.
NOTICE! Open windows for air circulation during fi re-
place break-in.
• Some people may be sensitive to smoke and odors.
• Smoke detectors may activate.
K. Frequently Asked Questions
ISSUESOLUTIONS
Condensation on the glass
Blue fl ames
Odor from fi replace
Film on the glass
Metallic noise
This is a result of gas combustion and temperature variations. As the fi replace warms, this
condensation will disappear.
This is a result of normal operation and the fl ames will begin to yellow as the fi replace is al-
lowed to burn for 20 to 40 minutes.
When fi rst operated, this fi replace may release an odor for the fi rst several hours. This is
caused by the curing of materials from manufacturing. Odor may also be released from fi nish-
ing materials and adhesives used near the fi replace. These circumstances may require ad-
ditional curing related to the installation environment.
This is a normal result of the curing process of the paint and logs. Glass should be cleaned
within 3 to 4 hours of initial burning. A non-abrasive cleaner such as gas appliance glass
cleaner may be necessary. See your dealer.
Noise is caused by metal expanding and contracting as it heats up and cools down, similar to
the sound produced by a furnace or heating duct. This noise does not affect the operation or
longevity of the fi replace.
Any safety screen or guard removed for servicing must be
replaced prior to operating the fi replace.
When properly maintained, your fi replace will give you
many years of trouble-free service. We recommend annual service by a qualifi ed service technician.
A. Maintenance Tasks-Homeowner
Installation and repair should be done by a qualifi ed service
technician only. The fi replace should be inspected before
use and at least annually by a professional service person.
The following tasks may be performed annually by the
homeowner. If you are uncomfortable performing any of
the listed tasks, please call your dealer for a service appointment.
More frequent cleaning may be required due to lint from
carpeting or other factors. Control compartment, burner
and circulating air passageway of the fi replace must be
kept clean.
CAUTION! Risk of Burns! The fi replace should be turned
off and cooled before servicing.
• Inspect exhaust termination for blockage or obstruction
such plants, bird nests, leaves, snow, debris, etc.
• Verify exhaust termination clearance to subsequent construction (building additions, decks, fences, or sheds).
See Section 6.
By: Qualifi ed Service Technician
Tools needed: Protective gloves, vacuum cleaner, dust
cloths
• V acuum and wipe out dust, cobwebs, debris or pet hair.
Use caution when cleaning these areas. Screw tips that
have penetrated the sheet metal are sharp and should
be avoided.
• Remove all foreign objects.
• Verify unobstructed air circulation.
B. Maintenance Tasks-Qualifi ed Service
Technician
The following tasks must be performed by a qualifi ed ser-
vice technician.
Gasket Seal and Glass Assembly Inspection
Frequency: Annually
By: Qualifi ed Service Technician
T ools needed: Protective gloves, drop cloth and a stable
work surface.
• Inspect gasket seal and its condition.
• Inspect fi xed glass assembly for scratches and nicks that
can lead to breakage when exposed to heat.
• Confi rm there is no damage to glass or glass frame.
Replace as necessary.
• Verify that fi xed glass assembly is properly retained and
attachment components are intact and not damaged.
Replace as necessary.
Logs
Frequency: Annually
By: Qualifi ed Service Technician
Tools needed: Protective gloves.
• Inspect for damaged or missing logs. Replace as necessary . Refer to Section 11 for log placement instructions.
• Verify correct log placement and no fl ame impingement
causing sooting. Correct as necessary.
Firebox
Frequency: Annually
By: Qualifi ed Service Technician
Tools needed: Protective gloves, sandpaper, steel wool,
cloths, mineral spirits, primer and touch-up paint.
• Inspect for paint condition, warped surfaces, corrosion
or perforation. Sand and repaint as necessary.
• Replace fi replace if fi rebox has been perforated.
Burner Ignition and Operation
Frequency: Annually
By: Qualifi ed Service Technician
T ools needed: Protective gloves, vacuum cleaner, whisk
broom, fl ashlight, voltmeter, indexed drill bit set, and a
manometer.
• Verify burner is properly secured and aligned with pilot
or igniter.
• Clean off burner top, inspect for plugged ports, corrosion
or deterioration. Replace burner if necessary.
• Replace Glowing embers with new dime-size pieces.
DO NOT block ports or obstruct lighting paths. Refer to
Section 11 for proper ember placement.
• Verify batteries have been removed from battery backup IPI systems to prevent premature battery failure or
leaking.
• Check for smooth lighting and ignition carryover to all
ports. Verify that there is no ignition delay.
• Inspect for lifting or other fl ame problems.
• Verify air shutter setting is correct. See Section 11 for
required air shutter setting. Verify air shutter is clear of
dust and debris.
• Inspect orifi ce for soot, dirt and corrosion. Verify orifi ce
size is correct. See Service Parts List for proper orifi ce
sizing.
• Verify manifold and inlet pressures. Adjust regulator as
required.
• Inspect pilot fl ame pattern and strength. See Figure 3.2
and 3.3 for proper pilot fl ame pattern. Clean or replace
orifi ce spud as necessary.
• Inspect thermocouple/thermopile or IPI fl ame sensing rod
for soot, corrosion and deterioration. Clean with emery
cloth or replace as required.
• Verify that there is not a short in fl ame sense circuit by
checking continuity between pilot hood and fl ame sense
rod. Replace pilot as necessary. (IPI only)
Heat & Glo LifeStyle direct vent gas appliances are designed to operate with all combustion air siphoned from
outside of the building and all exhaust gases expelled to
the outside. No additional outside air source is required.
The Twilight-II-B has been carefully engineered to provide a unique fi replace experience. Since it is different
than any other product on the market, care must be taken
when installing this appliance so that our customer does
not experience undesirable performance or conditions.
1. Install the appliance according to this Owner’s Guide
paying particular attention to fl ashing and sealing in-
structions.
2. In the cold northern climates pay attention to exposures and prevailing wind conditions when locating the
appliance, the same as you would for locating exterior
windows and doors.
The Twilight-II-B has the thermal characteristics of a high
quality window system. T emperatures near the appliance will
be cooler than what is realized with a fully insulated wall.
Operation of the appliance will eliminate any cool drafts
and will provide the room with a comfortable ambiance.
Installation MUST comply with local, regional, state and
national codes and regulations. Consult insurance carrier,
local building inspector, fi re offi cials or authorities having
jurisdiction over restrictions, installation inspection and
permits.
Before installing, determine the following:
• Where the appliance is to be installed.
• Gas supply piping requirements.
• Electrical wiring requirements.
• Framing and fi nishing details.
• Whether optional accessories—devices such as a fan,
wall switch, or remote control—are desired.
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. For
assistance or additional information, consult a qualifi ed
service technician, service agency or your dealer.
B. Tools and Supplies Needed
Before beginning the installation be sure that the following
tools and building supplies are available.
Tape measure Framing material
Pliers High temperature caulking material
Hammer Phillips screwdriver
Gloves Framing square
Voltmeter Electric drill and bits (1/4 in.)
Plumb line Safety glasses
Level Reciprocating saw
Manometer Flat blade screwdriver
Non-corrosive leak check solution
1/2 - 3/4 in. length, #6 or #8 Self-drilling screws
One 1/4 in. female connection (for optional fan).
C. Inspect Appliance and Components
• Carefully remove the appliance and components from
the packaging.
• The vent system components and decorative doors and
fronts may be shipped in separate packages.
• If packaged separately, the log set and appliance grate
must be installed.
• Report to your dealer any parts damaged in shipment,
particularly the condition of the glass.
• Read all of the instructions before starting the instal-
lation. Follow these instructions carefully during the
installation to ensure maximum safety and benefi t.
WARNING! Risk of Fire or Explosion! Damaged parts
could impair safe operation. DO NOT install damaged, incomplete or substitute components. Keep appliance dry.
Hearth & Home T echnologies disclaims any responsibility for ,
and the warranty will be voided by, the following actions:
• Installation and use of any damaged appliance or vent
system component.
• Modifi cation of the appliance or vent system.
• Installation other than as instructed by Hearth & Home
Technologies.
• Improper positioning of the gas logs or the glass door.
• Installation and/or use of any component part not approved
by Hearth & Home Technologies.
Any such action may cause a fi re hazard.
WARNING! Risk of Fire, Explosion or Electric Shock!
DO NOT use this appliance if any part has been under
water. Call a qualifi ed service technician to inspect the
appliance and to replace any part of the control system
and/or gas control which has been under water.
When selecting a location for the appliance it is important to
consider the required clearances to walls (see Figure 5.1).
WARNING! Risk of Fire or Burns! Provide adequate
clearance around air openings and for service access.
Due to high temperatures, the appliance should be located out of traffi c and away from furniture and draperies.
GLASS
B
GLASS
A
NOTICE: Illustrations refl ect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
NOTICE: Install appliance on hard metal or wood surfaces
extending full width and depth. DO NOT install directly
on carpeting, vinyl, tile or any combustible material other
than wood.
WARNING! Risk of Fire! Do not install appliance against
vapor barriers or exposed insulation. Prevent contact with
sagging or loose insulation.
• Locate and install appliance to all clearance specifi cations
in manual.
• The chase must be properly blocked to prevent blown
insulation or other combustibles from entering and
making contact with fi replace.
• Failure to maintain airspace may cause overheating and
a fi re.
SIDING
OVERHANG
FINISHING MATERIALS
A
SIDING
A
B
A
SIDING
Note: Verify that tabs on insulation bracket are in an upright
position.
Note: Framing dimensions assume use of
1/2 inch thick wall covering materials on
exterior of framing only, and NO sheetrock
on interior of framing.
INTERIOR
FRAMING
C
A
B
VinylNon-vinyl
A36 in.12 in.
B64-5/16 in.35-5/16 in.
Figure 5.2 Exterior View - Minimum Clearances
From top of hood to
ceiling (interior) or
overhang (exterior).
WARNING! Risk of Fire! Comply with all minimum clearances as specifi ed. Framing or fi nishing material closer than
the minimums listed must be constructed entirely of noncombustible materials (i.e., steel studs, concrete board, etc).
Combustible and Non-combustible
Mantels- Indoor only
TOP VIEW
MEASURED
FROM CORNER
CEILING
NON-COMBUSTIBLE BOARD
(SUPPLIED ON APPLIANCE)
INDOOR SIDE ONLY
12
11
HOOD
10
9
8
7
6
11-5/8
10-5/8
9-5/8
8-5/8
7-5/8
35-3/4
13-5/8
12-5/8
Note: Measurements are in inches.
Figure 5.4 Clearances to a Combustible and/or Non-combustible
Indoor Mantel
FIREPLACE
1/2 IN.
HOOD
Figure 5.5 Clearances to a Combustible and/or Non-combustible
A = 0 in ........................clearances above grade, veran-
(See Note 1)
B
FP
F
FP
da, porch, deck or balcony
B* = 12 in. .....................clearances to window or door
that may be opened, or to permanently closed window.
D = 35-5/16 in. (
non-vinyl)
64-5/16 in. (vinyl) ......vertical clearance to ventilated
soffi t located above the hood
within a horizontal distance of 2
feet (60 cm) from the center-line
of the hood
E = 35-5/16 in.
(non-vinyl)
64-5/16 in. (vinyl).. ....clearance to unventilated soffi t
F = 9 in. ......................clearance to outside corner
G* = 12 in ......................clearance to inside corner
H = 3 ft. (Canada) ........not to be installed above a gas
meter/regulator assembly within
3 feet (90 cm) horizontally from
the center-line of the regulator
I = 3 ft. ........................clearance to service regulator
vent outlet and electric service
* 36 in. minimum for vinyl windows or vinyl siding.
** a appliance shall not open directly above a sidewalk or paved
driveway which is located between two single family dwellings
and serves both dwellings.
*** only permitted if veranda, porch, deck or balcony is fully open
on a minimum of 2 sides beneath the fl oor, or if the screened
porch guidelines are followed.
NOTE 1: Local codes or regulations may require different clearances.
NOTE 2: Termination in an alcove space (spaces open only on
one side and with an overhang) are permitted with the dimensions
specifi ed for vinyl or non-vinyl siding and soffi ts. 1. There must be 3
feet minimum between terminations or between the appliance and
termination. 2. All mechanical air intakes within 10 feet of a termination must be a minimum of 3 feet below the appliance hood. 3.
All gravity air intakes within 3 feet of the appliance hood must be a
minimum of 1 foot below the termination.
This appliance is approved for installation onto screened porches
with the following guidelines:
Figure 6.1 Minimum Clearances for Appliance Opening
= AIR SUPPLY INLET
X
H
= APPLIANCE OPENING
FP
M
I
FP
X
J or K
R
M
P
FP
Q
(See Note 2)
N
J = 9 in. (U.S.A.)
12 in. (Canada) .......clearance to non-mechani-
cal air supply inlet to building
or the combustion air inlet to
any other appliance
K = 3 ft. (U.S.A.)
6 ft. (Canada) ...........clearance to a mechanical
air supply inlet
L** = 54 in. .......................clearance above paved side-
(See Note 1)
walk or a paved driveway lo-
cated on public property
M***= 35-5/16 in. ...............clearance under veranda,
porch, deck, balcony or over-
hang
64-5/16 in. ..............vinyl
N = 12 in. ......................non-vinyl siding
36 in. ......................vinyl siding
P = 8 ft.
Q
Twilight-II-B10 feet2 x Q
1 additional termination capQ + 3 feet1 x Q
2 additional termination capsQ + 6 feet2/3 x Q
3 additional termination capsQ + 9 feet1/2 x Q
R
= (2 / # caps plus appliance) x Q
MAX
MIN
ACTUAL
R
MAX
ACTUAL
ACTUAL
ACTUAL
ACTUAL
Minimum porch area: 96 square feet
Minimum ceiling height: 92 inches
Minimum two walls must be screened
Minimum top of screen height, side walls: 6 ft. 8 in.
Minimum screen area: 64 square feet
NOTE: There may be some odor and small amounts of soot
associated with venting the Twilight-II-B onto a screened
porch. Ensuring good cross draft ventilation and routine
maintenance of the appliance will maximize comfort and
cleanliness.
The non-combustible assembly is located on right-hand
side of appliance (when looking from outdoor side of
appliance).
CAUTION
Handle with care.
• Non-combustible material may be damaged if dropped.
• Hold non-combustible pieces in place.
• Remove and save two screws from upper bracket.
• Remove non-combustible pieces.
• Remove and save three screws from lower bracket.
• Discard brackets.
• Replace screws in holes where brackets were attached
to appliance.
CAUTION
Handle with care.
• Avoid damaging protruding edges on outdoor side of appliance.
B. Securing and Leveling the Appliance
METAL HEARTH STRIP
UNDER EDGE OF
APPLIANCE
Figure 7.1 Positioning the Metal Hearth Strip
APPLIANCE
EXTERIOR
WARNING
Fire Risk.
• Prevent contact with sagging, loose
insulation.
• Do NOT install against vapor barriers or
exposed insulation.
Placing Metal Hearth Strip
The metal hearth strip (approximately 46 inches x 4 inches)
is used to provide added protection where appliance and
outer structure meet.
• Place a generous bead of silicone caulk into the corner
of the protective hearth strip.
• Place the metal strip onto the structure where the outer
edge of the appliance will sit (see Figure 7.1). It should
overlap building paper to prevent water infi ltration.
Place the appliance into position. Make sure fl ashing edges
on the outdoor surround fi t up tight to the framing.
The diagram shows how to properly position, level, and
secure the appliance (see Figure 7.2). Nailing tabs are provided to secure the appliance to the framing members.
• Caulk behind fl anges before securing to framing.
• Place the appliance into position.
• Level the appliance from side to side and front to
back.
• Shim the appliance as necessary. It is acceptable to
use wood shims.
• Keep nailing tabs fl ush with the framing.
• Secure the appliance to the framing by using nails or
screws through the nailing tabs.
APPLY HIGH
TEMPERATURE
SILICONE SEALANT
TO CORNER EDGES
FIREPLACE
FLANGE
BEND IN
FLANGE
Figure 7.3
Install outdoor fl ashing header (sheetmetal piece removed
from shipping pallet). Place over upper portion of shroud
fl ange. Line up holes on shroud sides (see Figure 7.4).
SECURE TO
FRAMING IN A MINIMUM
3 PLACES PER SIDE
APPLIANCE
EXTERIOR
SECURE TO
FRAMING
NOTE: The exterior side of the appliance can protrude
outward. It MUST NOT be recessed into the framing. Caulk
behind all fl anges before securing to the exterior.
Figure 7.2 Proper Positioning, Leveling and Securing of a Appliance
CAUTION
Do NOT notch into the framing around the appliance spacers.
Placing Flashing and Sheathing
Apply high temperature silicone sealant to corner edges
of fi replace fl ange (see Figure 7.3).
FLASHING
HEADER
(SLIDE DOWN)
FLASHING
HEADER
(INSTALLED)
Figure 7.4
Seal fl ashing to exterior of building using high tempera-
ture caulk. Attach to building using holes provided on the
top of the left and right sides of outdoor fl ashing (see Fig-
ure 7.4).
For placement of combustible housewrap or building paper and non-combustible sheathing for the outside wall
see Figures 7.5 and 7.6.
Special care should be taken when choosing building
materials for weather proofi ng (i.e. building wraps, seal-
ant tapes, liquid sealants, rubberized fl ashings, etc.).
All sealant materials or building wraps installed within 6
inches of the top and sides of the fi replace surround must
be approved to a minimum temperature of 225º F continuous exposure. Consult the material’s manufacturer to
ensure product compliance.
TOP OF SURROUND
METAL FLASHING
* NOTE: All fi nishing materials on top of exterior sheathing
must be non-combustible for a minimum of 12 inches
above and on both sides of the exterior face of the
appliance. This non-combustible fi nishing material can
be up to a maximum of 6 inches thick (6 inches maximum
horizontal overhang) to allow for brick and stone alcoves
(see Figure 8.5).
** NOTE: Combustible house wrap or building paper
MUST NOT extend over the outside of non-combustible
sheathing, and MAY extend over the fl ashing behind non-
combustible sheathing. Use high temp silicone or sealant
recommended by the manufacturer of the housewrap to
seal between combustible sheathing house wrap and noncombustible sheathing. The sealant material used within
6 inches of the top and sides of the fi replace surround
must be approved to a minimum temperature of 225º F
continuous exposure.
6 IN.
EDGE OF SURROUND
Figure 7.5 Outside View without Non-combustible Sheathing Shown
SHEATHING,
COMBUSTIBLE
WALL STUD
FIREPLACE
HEADER
HOUSEWRAP
(BUILDING
PAPER) OVERLAP
FLASHING 1 in.
6 IN.
**
Once the appliance is in place use enough high temperature silicone sealant or manufacturer specifi ed sealant
(approved to a minimum of 225º F) to make a water tight
seal between outdoor surround and exterior sheathing.
Face the perimeter of the appliance with non-combustible
sheathing over shroud fl anges and fl ashing. See Figure
7.7 for non-combustible zone.
= SHEATHING
= NON-COMBUSTIBLE ZONE
12 in.
2-3/4 in.
2-3/4 in.
HOUSEWRAP
INSULATION
FLASHING
HEADER
INSULATED
FRAMING
STANDOFF
Figure 7.6
NON-COMBUSTIBLE
SHEATHING
12 in.
FIREPLACE
TL-TRIM KIT
APPLIANCE
HOOD
*
TOP OF
16-5/16 in.
TOP HOOD
Figure 7.7 Non-combustible Zone (Exterior)
WARNING
Risk of Fire
• Non-combustible clearances must be maintained.
• Sheetrock, wood or other combustibles must
NOT be used as sheathing or facing in the noncombustible zone.
• See Sections 3 and 8 for proper clearances.
• See Section 1 for combustible /non-combus-
tible defi nitions.
• Gas line sizing requirements will be determined in ANSI
Z223.1 National Fuel Gas Code in the USA and CAN/
CGA B149 in Canada.
• Pressure requirements are:
Gas PressureNatural GasPropane
Minimum inlet pressure5.0 in. w.c.11.0 in. w.c.
Maximum inlet pressure14.0 in. w.c.14.0 in. w.c.
Manifold pressure3.5 in. w.c.10.0 in. w.c.
WARNING! Risk of Fire or Explosion! High pressure
will damage valve. Low pressure may cause explosion.
• Verify inlet pressures. Verify minimum pressures when
other household gas appliances are operating.
• Install regulator upstream of valve if line pressure is
greater than 1/2 psig.
WARNING
Fire Risk.
Explosion Hazard.
High pressure will damage valve.
• Disconnect gas supply piping BEFORE
pressure testing gas line at test pressures
above 1/2 psig.
• Close the manual shutoff valve BEFORE
pressure testing gas line at test pressures
equal to or less than 1/2 psig.
Note: Have the gas supply line installed in accordance with
local codes, if any. If not, follow ANSI 223.1. Installation
should be done by a qualifi ed installer approved and/or
licensed as required by the locality. (In the Commonwealth
of Massachusetts installation must be performed by a
licensed plumber or gas fi tter).
Note: A listed (and Commonwealth of Massachusetts approved) 1/2 in. (13 mm) T-handle manual shut-off valve
and fl exible gas connector are connected to the 1/2 in. (13
mm) control valve inlet.
• If substituting for these components, please consult
local codes for compliance.
C. Gas Connection
• Refer to Reference Section 13 for location of gas line
access in appliance.
• Gas line may be run through knockout(s) provided.
• The gap between supply piping and gas ac cess hole
may be caulked with high temperature caulk or stuf fe d
with non-combustible, unfaced insulation to prev ent cold
air infi ltration.
• Ensure that gas line does not come in contact with outer
wrap of the appliance. Follow local codes.
• Pipe incoming gas line into valve compartment.
• Connect incoming gas line to the 1/2 in. (13 mm)
connection on manual shutoff valve.
WARNING! Risk of Fire or Explosion! Support control
when attaching pipe to prevent bending gas line.
• A small amount of air will be in the gas supply lines.
WARNING! Risk of Fire or Explosion! Gas build-up dur ing line purge could ignite.
• Purge should be performed by qualified service
technician.
• Ensure adequate ventilation.
• Ensure there are no ignition sources such as sparks
or open fl ames.
Light the appliance. It will take a short time for air to purge
from lines. When purging is complete the appliance will
light and operate normally.
WARNING! Risk of Fire, Explosion or Asphyxiation!
Check all fi ttings and connections with a non-corrosive
commercially available leak-check solution. DO NOT use
open fl ame. Fittings and connections could have loos-
ened during shipping and handling.
WARNING! Risk of Fire! DO NOT change valve settings.
This valve has been preset at the factory.
D. High Altitude Installations
NOTICE: If the heating value of the gas has been reduced,
these rules do not apply. Check with your local gas utility
or authorities having jurisdiction.
When installing above 2000 feet elevation:
• In the USA: Reduce burner orifi ce 4% for each 1000 feet
above 2000 feet.
• In CANADA: Reduce burner orifi ce 10% for elevations
between 2000 feet and 4500 feet. Above 4500 feet,
consult local gas utility.
NOTICE: This appliance must be electrically wired
and grounded in accordance with local codes or, in the
absence of local codes, with National Electric Code
ANSI/NFPA 70-latest edition or the Canadian Electric
Code CSA C22.1.
• Wire the appliance junction box to 1 10-120 VAC. This is
required for proper operation of the appliance.
• A 1 10-120 V AC circuit for this product must be protected
with ground-fault circuit-interrupter protection, in
compliance with the applicable electrical codes, when
it is installed in locations such as in bathrooms or near
sinks.
• Low voltage and 110 VAC voltage cannot be shared
within the same wall box.
WARNING! Risk of Shock or Explosion! DO NOT wire
1 10V to the valve or to the appliance wall switch. Incorrect
wiring will damage controls.
NOTICE: Waterproof insulated wire should be used when
wiring the junction box.
B. Connecting to the Appliance
WARNING
Wire 110V to electrical junction box.
Do NOT wire 110V to valve.
Do NOT wire 110V to wall switch.
• Incorrect wiring will damage millivolt valves.
• Incorrect wiring will override IPI safety lockout
and may cause explosion.
• This appliance may be used with a wall switch, wall
mounted thermostat and/or a remote control.
• If using thermostat use one compatible with a millivolt
gas valve system.
• Follow parameters for locating thermostat (see individual
thermostat instructions) to ensure proper operation of
appliance.
• Keep wire lengths short as possible by removing any
excess wire length.
• Low voltage and 110 VAC voltage cannot be shared
within the same wall box.
• Wire the appliance junction box to 110 VAC for proper
operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.
• Refer to Figure 9.2, Intellifi re Pilot Ignition (IPI) Wiring
Diagram.
• This appliance is equipped with an Intellifi re control valve
which operates on a 3 volt system.
• Plug the 3-volt AC transformer into the appliance junction
box to supply power to the unit OR install two D cell
batteries (not included) into the battery pack before use.
NOTICE: Batteries should not be placed in the battery
pack while using the transformer. Remove batteries before
using the transformer, and unplug the transformer before
installing the batteries. Battery polarity must be correct or
module damage will occur.
3V TRANSFORMER
ON/OFF
WALL
SWITCH
VALVE
NEUTRAL
BLACK WIRE CAN BE
PLUGGED INTO ANY OF
#1 - #5 LOCATIONS
ON THE HOT SIDE
PLUG-IN
IGNITION
MODULE
(3V)
LOW VOLTAGE
GROUND
FLAME SPARKER/
SENSOR
SEE NOTE 1
REMOTE
CONTROL
WHITE WIRE
CAN BE
PLUGGED
INTO ANY
OF #1-#5
LOCATIONS
ON THE
NEUTRAL SIDE
HOT
IGNITION MODULE
3 VAC
TRANSFORMER
3 VAC
BRN
PIGGYBACK
ON/OFFSWITCH
BRN
I
S
GROUND TO
FIREPLACE
CHASSIS
INTERMITTENT
PILOT
IGNITOR
WHT
ORG
ORG
GRN
NOTE: 1. Ignition module, valve, pilot, and wall switch operate on 3 volts.
Uninterrupted 120 VAC is required at junction box unless equipped with battery back-up.
Figure 9.3 Intellifi re Pilot Ignition (IPI) Wiring Diagram
Optional fan and remote control kits require that 110-120
VAC be wired to the factory installed junction box before
the appliance is permanently installed (see Figure 9.3).
Fan Installation
To provide best airfl ow, we recommend positioning fan
on the left side (as viewed from appliance interior side
(see Figure 9.2). NOTE: It is recommended fan be installed prior to gas line installation.
Wall Switch
Position the wall switch in the desired position on a wall.
Run a maximum of 25 feet (7.8 m) or less length of 18
A.W.G. minimum wire and connect it to the appliance ON/
OFF switch pigtails.
FAN SPEED
CONTROL
(RHEOSTAT)
6 FT.
APPROX.
WIRE LEAD
1 MALE END
1 FEMALE END
APPLIANCE
INTERIOR
SIDE
FAN
DRIP
TRAY
Figure 9.2 Fan location
DETAIL A
PLUG AND WIRE
ASSEMBLY
Figure 9.3 Fan Wiring Diagram
FAN KIT
#GFK-160T
6 FT.
APPROX.
TEMPERATURE
SENSOR SWITCH
WIRE LEAD
2 FEMALE ENDS
JUNCTION BOX
SEE DETAIL A
NOTE: If any of the original wire as supplied
with the appliance must be replaced, it must be
replaced with the type 105oC rated wire.
If the box is being wired from the OUTSIDE of the
appliance:
• Install the Romex™ connector (not included with
appliance) in the side wrap.
• Loosen two screws on the Romex connector, feed
the necessary length of wire through the connector
and tighten the screws.
• Make all necessary wire connections.
If the box is being wired from the INSIDE of the
appliance:
• Remove the screw attaching the junction box to
the outer shell, rotate the junction box inward to
disengage it from the outer shell (see Figure 9.4).
• Pull the electrical wires from outside the appliance
through this opening into the valve compartment.
HEAT SHIELD
14/2WG
COPPER GROUND
WHT
BLK
BLK
WHT
ATTACHED TO GRN SCREW
WITH GRN WIRE
GREEN WIRE
INSIDE BOX
NOTE: Do NOT wire
110 VAC to wall switch.
Figure 9.4 Junction Box Detail
• Loosen the two screws on the Romex connector, feed the
necessary length of wire through the connector and tighten the
screws.
• Make all necessary wire connections to the receptacle and
assemble the receptacle and cover to the junction box.
F. Wall Switch Installation for Fan (Optional)
If the box is being wired to a wall mounted switch for use
with a fan (See Figure 9.5):
• The power supply for the appliance must be brought into
a switch box.
• The power can then be supplied from the switch box to the
appliance using a minimum of 14-3 with ground wire.
• At the switch box connect the black (hot) wire and red
(switch leg) wire to the wall switch as shown.
• At the appliance connect the black (hot), white (neutral)
and green (ground) wires to the junction box as shown.
• Add a 1/4 in. insulated female connector to the red (switch
leg) wire, route it through the knockout in the face of the
junction box, and connect to the top fan switch connector
(1/4 in. male) as shown.
Minimum 14-3 AWG
with Ground
Junction Box
Red
Figure 9.5 Junction Box Wired to Wall Switch or BC10
WARNING! Risk of Fire! Comply with all minimum clearances as specifi ed. Framing closer than the minimums list-
ed must be constructed entirely of noncombustible materials (i.e., steel studs, concrete board, etc.) Failure to comply
could cause fi re.
CEILING
NON-COMBUSTIBLE BOARD
(SUPPLIED ON APPLIANCE)
INDOOR SIDE ONLY
12
11
HOOD
10
9
8
7
6
11-5/8
10-5/8
9-5/8
8-5/8
7-5/8
35-3/4
13-5/8
12-5/8
B. Facing Material
Inside Facing Material
• May install combustible materials up to specified
clearances on top, front and sides of appliance.
• Seal joints between fi nished wall and appliance top and
sides with 300º F (140º C) minimum sealant.
• Leave space so bottom grille can be lowered for trim
door removal.
WARNING! Risk of Fire! DO NOT apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as specifi ed in
this manual. Overlapping materials could ignite and will
interfere with proper operation of doors and louvers.
NON-COMBUSTIBLE ZONE
41-7/8 in.
2-3/4 in.
Note: Measurements are in inches.
Figure 10.1 Clearances to a Combustible and/or Non-combustible
Indoor Mantel
TOP VIEW
MEASURED
FROM CORNER
1/2 IN.
FIREPLACE
HOOD
Figure 10.2 Clearances to a Combustible and/or Non-combustible
NOTE: All fi nishing materials on top of exterior
sheathing must be non-combustible for a minimum
of 12 inches above and on both sides of the exterior
face of the appliance. This non-combustible
fi nishing material can be up to a maximum of
6 inches thick (6 inches maximum horizontal
overhang) to allow for brick and stone alcoves
(see Figure 8.5).
NOTE: Combustible housewrap or building
paper MUST NOT extend over the outside of
non-combustible sheathing, and MAY extend
over the fl ashing header behind non-combustible
sheathing. Use hightemp caulk to seal between
combustible sheathing housewrap and noncombustible sheathing.
STUD WALL
FIREPLACE
HEADER
SOFFIT
SHEATHING,
COMBUSTIBLE
HOUSEWRAP
(BUILDING
PAPER) OVERLAP
FLASHING 1 in.
NON-COMBUSTIBLE
SHEATHING
CEILING OR OVERHANG
35-5/16 in.
MINIMUM CLEARANCE TO
NON-VINYL SOFFIT, MANTEL,
CEILING OR OVERHANG.
64-5/16 in.
MINIMUM CLEARANCE
TO VINYL SOFFIT,
CEILING OR OVERHANG.
Figure 10.6 Exterior View
HOUSEWRAP (BUILDING
PAPER) AND SHEA THING
DETAIL -
SEE FIGURE 8.5
INSULATION
HOUSEWRAP
INSULATION
FLASHING
HEADER
SIDING
INSULATED
FRAMING
STANDOFF
DRAIN PLANE
DETERMINED BY
LOCAL CODE
CLEARANCE TO VINYL SIDING
TOP OF
APPLIANCE
SOFFIT
SOFFIT, OVERHANG, MANTEL,
12 in.
MINIMUM CLEARANCE
TO NON-VINYL SIDING
36 in. MINIMUM
12 in.
APPLIANCE
HOOD
35-5/16 in.
MINIMUM CLEARANCE
TO NON-VINYL
64-5/16 in.
CLEARANCE TO VINYL
OR CEILING
TOP OF
FIREPLACE
TOP HOOD
APPLIANCE
HOOD
Figure 10.7 Exterior View with Non-combustible Facing Material
Remove shipping materials from inside or underneath the
fi rebox.
C. Clean the Appliance
Clean/vacuum any sawdust that may have accumulated
inside the fi rebox or underneath in the control cavity.
D. Accessories
Install approved accessories per instructions included
with accessories. Contact your dealer for a list of approved accessories.
WARNING! Risk of Fire and Electric Shock! Use ONLY
Hearth & Home Technologies-approved optional accessories with this appliance. Using non-listed accessories
could result in a safety hazard and will void the warranty.
E. Lava Rock and Ember Placement
WARNING! Risk of Explosion! Follow ember placement
instructions in manual. DO NOT place embers directly over
burner ports. Replace ember material annually . Improperly
placed embers interfere with proper burner operation.
Placing Lava Roch
Place lava rock on refractory support pan. Cover entire
support pan surface (see Figure 11.1).
Figure 11.1 Placement of Lava Rock
Placing the Ember Material
Ember material is shipped with this gas appliance. T o place
the ember material:
• Embers CANNOT be placed directly over ports.
• When placing Glowing Embers
should be taken so that the ports are not covered. Place
the dime-size ember pieces just in front of the port trail,
but not on or in between the ports (see Figure 11.2).
Failure to follow this procedure will likely cause lighting
and sooting problems.
®
onto the burner care
Figure 11.2 Placement of Ember Materials
• Save the remaining ember materials for use during
appliance servicing. The embers provided should be
enough for 3 to 5 applications.
CAUTION: Logs are fragile! Carefully remove the logs
from the packaging. Remove the cardboard support from
inside of fi replace.
INDENT
BOTTOM VIEW
INDENT
BACK VIEW
STEP 2. LOG #1 (SRV2005-701): Use the indent on the bottom side of the log to position the large end of the log onto
the grate bar as shown. Slide the log back until the indent engages the grate tine as shown above. Position the thin end of
log #1 one inch from port pattern as shown.
GRATE BAR CUTOUT
STEP 1. Before positioning the logs, refer to the installation
manual for electric ember set-up and ember placement.
GRATE TINE (HIDDEN)
1
GRATE
BAR
1-inch
1
2
PILOT
ASSEMBLY
CUTOUT
STEP 3. LOG #2 (SRV2005-700): Position log #2 on the left grate bar and the pilot assembly. Use the cut out notches
STEP 4. LOG #3 (SR V2005-702): Position log #3 as shown by leaning it against log # 2 and resting the other end on the
peak of the burner. DO NOT cover any port holes.
3/4 IN.
4
3
2
1
1
SHARP
NOTCH
STEP 5. LOG #4 (SRV2005-703): Locate the sharp notch on log #4 against the grate tine as shown. The smooth cutout
on the bottom of log #4 should rest on the burner surface. The side of Log #4 must be 3/4 inch from the nearest port hole
on the right side of log #4. DO NOT cover any port holes.
1
SHARP
NOTCH
3
2
2
GRATE
TINE
5
4
1
STEP 6. LOG #5 (SRV2005-704): Using the sharp notch on the heavy end of log #5, align it on the grate tine and set it
WARNING! Risk of Asphyxiation! Handle fi xed glass
assembly with care. Inspect the gasket to ensure it is
undamaged and inspect the glass for cracks, chips or
scratches.
• DO NOTstrike, slam or scratch glass.
• DO NOToperate fi replace with glass removed, cracked,
broken or scratched.
• Replace as a complete assembly.
Removing Fixed Glass Assembly
• Remove wing nuts and glass clips around glass door.
Remove glass door from the appliance.
Replacing Fixed Glass Assembly
• Replace the glass door on the appliance.
H. Install Trim and/or Surround
• Install optional trim kits and/or surrounds using the
instructions included with the accessory.
• Use non-combustible materials to cover the gap between
the sheet rock and the appliance (when applicable to the
model).
I. Air Shutter Setting
Air shutter settings should be adjusted by a qualifi ed ser-
vice technician at the time of installation. The air shutter
is set at the factory for minimum vertical vent run. Adjust
air shutter for longer vertical runs.
NOTICE: If sooting occurs, provide more air by opening
the air shutter.
With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do
experience a problem, this troubleshooting guide will assist a qualifi ed service technician in the diagnosis of a problem and
the corrective action to be taken. This troubleshooting guide can only be used by a qualifi ed service technician. Contact
your dealer to arrange a service call by a qualifi ed service technician.
A. Intellifi re Ignition System
SymptomPossible CauseCorrective Action
1. Pilot won’t light.
The ignitor/module
makes noise, but no
spark.
2. Pilot won’t light,
there is no noise or
spark.
A. Incorrect wiring.Verify “S” wire (white) for sensor and “I” wire (orange) for ignitor are
connected to correct terminals on module and pilot assembly.
B. Loose connections or electrical
shorts in the wiring.
C. Ignitor gap is too large.Verify gap of igniter to right side of pilot hood. The gap should be
D. Module.Turn ON/OFF rocker switch or wall switch to OFF position. Remove
A. No power or transformer installed
incorrectly.
B. A shorted or loose connection in
wiring confi guration or wiring har-
ness.
Verify no loose connections or electrical shorts in wiring from module to pilot assembly. Verify connections underneath pilot assembly are tight; also verify connections are not grounding out to metal
chassis, pilot burner, pilot enclosure, mesh screen if present, or any
other metal object.
approximately .17 in. or 1/8 in. (3 mm).
ignitor wire “I” from module. Place a grounded wire about 3/16 in. (5
mm) away from “I” terminal on module. Place ON/OFF rocker switch
or wall switch in ON position. If there is no spark at “I” terminal module
must be replaced. If there is a spark at “I” terminal, module is fi ne.
Inspect pilot assembly for shorted sparker wire or cracked insulator
around electrode. Replace pilot if necessary .
Verify that transformer is installed and plugged into module. Check
voltage of transformer under load at spade connection on module
with ON/OFF switch in ON position. Acceptable readings of a good
transformer are between 3.2 and 2.8 volts AC.
Remove and reinstall the wiring harness that plugs into module.
Verify there is a tight fi t. Verify pilot assembly wiring to module. Re-
move and verify continuity of each wire in wiring harness. Replace
any damaged components.
3. Pilot sparks, but
Pilot will not light.
C. Improper wall switch wiring.Verify that 110/VAC power is “ON” to junction box.
D. Module not grounded.Verify black ground wire from module wire harness is grounded to
metal chassis of appliance.
E. Module.Turn ON/OFF rocker switch or wall switch to OFF position. Remove
ignitor wire “I” from module. Place ON/OFF rocker switch or wall
switch in ON position. If there is no spark at “I” terminal module
must be replaced. If there is a spark at “I” terminal, module is fi ne.
Inspect pilot assembly for shorted sparker wire or cracked insulator
around electrode.
A. Gas supply.Verify that incoming gas line ball valve is “open”. Verify that inlet
pressure reading is within acceptable limits, inlet pressure must not
exceed 14 in. W.C.
B. Ignitor gap is too large.Verify gap of igniter to right side of pilot hood. The gap should be
approximately .17 in. or 1/8 in. (3 mm).
C. Module is not grounded.Verify module is securely grounded to metal chassis of appliance.
D. Module voltage output / Valve/Pilot
Verify battery voltage is at least 2.7 volts. Replace batteries if volt-
age is below 2.7.
Intellifi re Ignition System - (continued)
SymptomPossible CauseCorrective Action
4. Pilot lights but continues to spark, and main
burner will not ignite.
(If the pilot continues
to spark after the
pilot fl ame has been lit, fl ame rectifi cation has
not occurred.)
A. A shorted or loose connection in fl ame
sensing rod.
B. Poor fl ame rectifi cation or contaminated
fl ame sensing rod.
C. Module is not grounded.Verify module is securely grounded to metal chassis of ap-
D. Damaged pilot assembly or contami-
nated fl ame sensing rod.
E. Module.Turn ON/OFF rocker switch or wall switch to OFF position.
Verify all connections to wiring diagram in manual. Verify
connections underneath pilot assembly are tight. Verify connections are not grounding out to metal chassis, pilot burner, pilot enclosure or screen if present, or any other metal
object.
With fi xed glass assembly in place, verify that fl ame is en-
gulfi ng fl ame sensing rod on left side of pilot hood. Flame
sensing rod
rect pilot orifi ce is installed and gas inlet is set to pressure
specifi cations. Clean fl ame sensing rod with emery cloth to
remove any contaminants that may have accumulated on
fl ame sensing rod.
pliance. Verify that wire harness is fi rmly connected to the
module.
Verify that ceramic insulator around the fl ame sensing rod
is not cracked, damaged, or loose. Verify connection from
fl ame sensing rod to white sensor wire. Clean fl ame sensing
rod with emery cloth to remove any contaminants that may
have accumulated on fl ame sensing rod. Verify continuity
with a multimeter with ohms set at lowest range. Replace
pilot if any damage is detected.
Remove ignitor wire “I” from module. Place ON/OFF rocker
switch or wall switch in ON position. If there is no spark at “I”
terminal module must be replaced. If there is a spark at “I”
terminal, module is fi ne.
IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement
parts for your appliance please provide model number and serial number. All parts listed
in this manual may be ordered from an authorized dealer.
ITEMDESCRIPTIONCOMMENTSPART NUMBER
Log Set Assembly /Burner Assembly
Log Set Assembly
2086-024Y
Glass Latch Assembly386-122AY
Lava Rock Bag 2005-790
Mineral Wool 050-721
Non-Combustible Boards (set only)2108-030
Pilot Tube 446-301Y
Touch Up Paint TUP-GBK-12
Trim Kit, BlackTL-TRIM-BK
Cover Panel
Defl ector Panel
Flashing
Hood-Exterior Side
Outdoor Surround
Wind Screen Assembly
UPGRADE2-TWII
All Others
See service parts diagram
2086-149
2086-114MBK
2086-136MBK
2087-159
2086-113MBK
2086-130MBK
Conversion Kit NG NGK-TWIY
Conversion Kit LP LPK-TWIY
Pilot Orifi ce NG593-528Y
Pilot Orifi ce LP593-527Y
Regulator NGNGK-DXFY
Regulator LPLPK-DXFY
Additional service part numbers appear on following page.
IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement
parts for your appliance please provide model number and serial number. All parts listed
in this manual may be ordered from an authorized dealer.
ITEMDESCRIPTIONCOMMENTSPART NUMBER
1
Burner Orifi ce (NG) (#32C)582-832Y
Burner Orifi ce (LP) (#50C) 582-850Y
2Flexible Gas Connector 383-302AY
3Burner Neck Gasket 438-407
4Bracket, Pilot Support Assembly385-120
5
Pilot Assembly NG 2090-012Y
Pilot Assembly LP 2090-013Y
6Orifi ce Bracket Gasket 2087-110
8Valve Plate Gasket 2087-112
7Orifi ce Bracket 2087-109
9Valve L Bracket 674-168