Models:
GO24MTCH,GO30MTCH
GO35MTCH, GO40MTCH
Grand Oak Match Light
Gas Log Sets
Check with your local building code agency before you begin installation to ensure compliance with local codes, including
the need for permits and follow-up inspections. If you encounter any problems regarding code approvals, or if you need
clarication of any of the instructions contained here, contact the Technical Services Dept., Hearth & Home Technologies
Installation and service of this
appliance should be performed by
qualied personnel. Hearth & Home
Technologies suggests NFI certied
or factory-trained professionals,
o r t e c h n i c i an s
s u p e r v i s e d b y
an N FI c e r tif i ed
professional.
CAUTION
DO NOT DISCARD THIS MANUAL
•
• Im portan t operating
a n d m a i n te n an c e
instructions included.
•
Rea d , understand
an d fo l low th e se
instructions for safe
i ns t a l l a t i o n a n d
operation.
Leave this manual with
party responsible for
use and operation.
WARNING
If the information in these instructions is not followed exactly, a
re may result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other ammable vapors and liquids in the vicinity of
this or any other appliance.
• What to do if you smell gas:
- Do not try to light any appliance.
- Do not touch any electrical switch. Do not
use any phone in your building.
- Immediately call your gas supplier from
a neighbor’s phone. Follow the gas
supplier’s instructions.
- If you cannot reach your gas supplier, call
the re department.
• Installation and service must be performed
by a qualied installer, service agency, or
the gas supplier.
Note: An arrow () found in the text signies change
in content.
Hearth & Home Technologies • Grand Oak Match Light Gas Log Sets • 4004-300 Rev D • 05/08
WARNING
HOT! DO NOT TOUCH.
SEVERE BURNS MAY RESULT.
CLOTHING IGNITION MAY RESULT.
Glass and other surfaces are hot during
operation and cool down.
• Keep children away.
• CAREFULLY SUPERVISE children in same room as
appliance.
• Alert chil d r e n an d ad u l ts to haz a r d s of hig h
temperatures.
• Do NOT operate with protective barriers removed.
• Keep cl o t h i n g , furni t u r e , draperies and oth e r
combustibles away.
In the Commonwealth of Massachusetts:
• This appliance must be installed by a licensed plumber
or gas tter.
• The chimney ue damper, when used with gas logs, will
be welded open or completely removed.
• A CO detector shall be installed in the room where the
appliance is installed.
1
Read this manual before installing or operating this appliance.
Homeowner Reference Information
Model Name: Date purchased/installed:
Serial Number: Location on appliance:
Dealership purchased from: Dealer phone:
Notes:
We recommend that you record the following pertinent
information about your gas log set:
Please retain this owner’s manual for future reference.
Congratulations
Congratulations on selecting a Hearth & Home Technologies
gas log set—an elegant and clean alternative to burning
wood. The Hearth & Home Technologies gas log set you
have selected is designed to provide the utmost in safety,
reliability, and efciency.
As the owner of this new gas log set, you’ll want to read and
carefully follow all of the instructions contained in this owner’s
manual. Pay special attention to all cautions and warnings.
This owner’s manual should be retained for future reference.
We suggest you keep it with your other important documents
and product manuals.
The information contained in this owner’s manual, unless
noted otherwise, applies to all models and gas control
systems.
Your new gas log set will give you years of durable use and
trouble-free enjoyment. Welcome to the Hearth & Home
Technologies family of appliance products!
Listing Label Information/Location
The model information regarding your specic gas log set can be found on the rating plate.
Model #
Hearth & Home Technologies
Angier, NC 27501
Serial #
Gas Type
2
Hearth & Home Technologies • Grand Oak Match Light Gas Log Sets • 4004-300 Rev D • 05/08
WARNING
WARNING
Improper installation, adjustment, alteration, service
or maintenance can cause injury or property damage.
Refer to the owner’s information manual provided with
this appliance. For assistance or additional information
consult a qualied installer, service agency or the gas
supplier.
CAUTION
Sharp Edges
• We a r protective gloves
and safety glasses during
installation.
A. Design and Installation Considerations
The Gas Log Hearth Kit consists of the following:
• Log Set
• Burner/Pan Assembly
• Grate Assembly
• Rock Wool
• Sand
• Lava Rock
• Damper Stop
• Vermiculite
• Platinum Embers
B. Tools and Supplies Needed
Tools and supplies normally required for installation:
Pliers
Phillips screwdriver
Tape measure
Crescent wrenches
Gas shutoff valve
Non-corrosive leak check solution
3/4 in. wrench, 7/16 in. wrench
HOT! DO NOT TOUCH.
SEVERE BURNS MAY RESULT.
CLOTHING IGNITION MAY RESULT.
Glass and other surfaces are hot during
operation and cool down.
• Keep children away.
• CAREFULLY SUPERVISE children in same room as
appliance.
• Alert chil d r e n an d ad u l ts to haz a r d s of hig h
temperatures.
• Keep cl o t h i n g , furni t u r e , draperies and oth e r
combustibles away.
- Review proper placement of logs, rockwool, lava rock
and vermiculite.
- Check the wiring.
- Ensure there are no gas leaks.
- Ensure the ow of combustion and ventilation air is not
obstructed (front grilles and vent caps).
• Before installing into a solid fuel burning replace, the
chimney and rebox should be inspected and cleaned to
remove soot, creosote, ashes, paint, bird nests etc.
• Annual examination of the chimney must be performed
by a qualied agency to ensure proper ventilation of ue
gases created by this appliance.
WARNING
Fire Risk
Exhaust Fumes Risk
• Do NOT use this appliance as a “vent-free
heater.
The ue must be permanently open according
to Tables 1 and 2.
C. Important!
• Do not remove any of the attached metal plates, which
contain important safety and operating information.
• Keep the appliance area clear and free of all combustible
materials, gasoline and other ammable vapors and
liquids.
• Any safety screen or guard removed during servicing must
be replaced before operation.
• A qualied service technician must perform installation and repair. The appliance should be inspected and cleaned
annually by a qualied service technician. More frequent
cleaning may be required due to excessive lint, dust, pet
hair, etc. It is imperative that the control compartments,
burners and air passageways are unobstructed during
operation.
Hearth & Home Technologies • Grand Oak Match Light Gas Log Sets • 4004-300 Rev D • 05/08
• Have the chimney and adjacent structure inspected
and cleaned by qualied professionals. Hearth & Home
Technologies recommends that NFI or CSIA certied
professionals, or technicians under the direction of certied
professionals, conduct a minimum of an NFPA 211 Level 2
inspection of the chimney.
• Replace component parts of the chimney and replace as
specied by the professionals.
• Ensure all joints are properly engaged and the chimmney
is properly secured.
• Do not allow fans to blow directly into the replace. Avoid
any drafts that alter burner ame pattern.
• Do not use a blower insert, heat exchanger insert or other
accessories not approved for use with this appliance.
3
• This appliance must have a screen in place while the
appliance is in operation and, unless other provisions for
combustion air are provided, the screen shall have an
opening for introduction of combustion air.
• Solid fuels shall not be burned in a replace where a
decorative appliance is installed.
• If glass doors are present, the glass doors must be fully opened while appliance is in operation.
WARNING
WARNING
Fire Risk
Explosion Risk
Verify inlet pressures.
• Hi g h p r ess u re ma y ca u se o ver fir e
condition.
• Low pressure may cause explosion.
Install regulator upstream of valve if line
pressure is greater than 1/2 psig.
Do NOT use this appliance if any part has been under
water. Immediately call a qualied service technician
to inspect the appliance and to replace any part of the
control system and any gas control which has been
under water.
D. Appliance Certication
This appliance has been evaluated by Omni in accordance
with the requirements of Ansi Z21.84-2004 Standard for
Decorative Log Sets for Installation in Wood Burning Fireplaces. Installation and the provisions for combustion and
ventilation air must conform to the National Fuel Gas Code,
ANSI Z223.1/NFPA 54, or the CSA B149.1, Natural Gas
and Propane Installation Code.
E. Gas Supply Connection
A 3/8 in. ared tting has been installed on the gas valve
inlet at the factory. Ensure ttings are of the appropriate size
and type on the gas line connection. If the tubing has to be
cut to length be sure to use the proper cutting and aring
tool. Also, be careful not to crimp the tubing while bending. If
the tubing becomes crimped, do not use for installation.
Gas resistant pipe compound must be used on all threaded
male connections to ensure a tight seal.
F. Gas Pressure
Proper input pressures are required for optimum appliance
performance. Gas line sizing requirements need to be made
following NFPA51.
WARNING
Fire Risk
Explosion Risk
High pressure will damage valve.
• Disconnect gas supply piping BEFORE
pressure testing gas line at test pressures
above 1/2 psig.
• Close the manual shutoff valve BEFORE
pressure testing gas line at test pressures
equal to or less than 1/2 psig.
• Gas Supply Pressure: Minimum inlet gas supply pressure
must be 7.0 in. W.C. for natural gas. The gas line
supplying the appliance must be sufcient size to furnish
the appropriate supply pressure to the appliance while
operating in the “High” setting.
• Pressure tap screws must be closed before turning gas
on to the appliance.
• Gas Line Pressure Test: Perform pressure test according
to state and local code (if pressure exceeds 1/2 in. psi (3.5
kPa)) before appliance is connected. Be sure to release
air pressure from the gas line before connection is made
to the appliance. Excessive pressure will damage the gas
control and may cause a gas leak.
• Gas Leak Test: Make sure the gas connections are tight.
Turn on the gas and coat each joint with a non-corrosive
gas leak check solution. Air bubbles will form indicating
any leaks. DO NOT USE A FLAME OR ANY TYPE OF
IGNITION SOURCE TO CHECK FOR LEAKS. All leaks
must be corrected before proceeding with installation.
• The appliance must only be installed in a solid-fuel burning
replace with the ue damper clamped open according
to Tables 1 and 2. The replace must be constructed of
non-combustible material.
• The minimum permanent free opening (in square inches)
that must be provided by the replace chimney or damper
to vent the ue gases is provided in Tables 1 and 2. If the
free opening is smaller than the specied area, do not use
this appliance.
• The damper must be removed or xed in a manner in
which will secure it open. Some jurisdictions require the
damper to be removed or permanently welded fully open.
Check with state and local codes.
• Be sure that the chimney is completely unobstructed to
ensure proper ventilation of ue gases including carbon
monoxide (CO). CO (a poisonous gas) is tasteless,
odorless, colorless and undetectable without proper
equipment.
• Refer to Table 3 to determine minimum replace opening
requirements before proceeding.
4
Hearth & Home Technologies • Grand Oak Match Light Gas Log Sets • 4004-300 Rev D • 05/08
G. Negative Pressure
Negative pressure results from the imbalance of air avail-
able for the replace to operate properly. Causes for this
imbalance include:
• Exhaust fans (kitchen, bath, etc.).
• Range hoods.
• Combustion air requirements for furnaces, water heaters
and other combustion appliances.
• Clothes dryers.
• Loc a tio n of r e turn - air v ents to f urna c e or air
conditioning.
Free Opening Area (in square inches) of Chimney Damper for
Venting combustion Products from Decorative Appliances for
Installation in Solid Fuel Burning Fireplaces.
Chimney Ht.
(Feet)*GO 24 & 35GO 30 & 40
10not approvednot approved
1538.545.4
2031.237.4
2527.331.2
3024.628.3
3522.125.5
4020.423.8
WARNING
Asphyxiation Risk
This appliance produces carbon monoxide
(CO).
• The free opening areas (in square inches)
of the chimney damper as shown in the
following tables must be met.
• User must make sure damper is locked
open.
• The installer is responsible to ensure
proper ventilation of ue gases before
appliance is used.
Fire needs to draft properly fo r sa f e
operation.
Table 2 for Masonary Built Fireplaces
Free Opening Area (in square inches) of Chimney Damper for
Venting combustion Products from Decorative Appliances for
Installation in Solid Fuel Burning Fireplaces.
Chimney Ht.
(Feet)*GO 24 & 35GO 30 & 40
66471.4
859.766.9
1054.360.2
1548.854.1
2044.449.1
3040.344.5
* Height is measured from the hearth to the top of the chimney.
Minimum height is 6 ft.
Table 3 for Minimum Fireplace Dimensions
Log Set
GO2432 in.20 in.18 in.21 in.73,000
GO3038 in.20 in.18 in.27 in.80,000
GO3534 in.23 in.22 in.22 in.86,000
GO4040 in.23 in22 in.29 in.86,000
Front
OpeningDepthHeight
Rear
Width
Natural
BTU
Hearth & Home Technologies • Grand Oak Match Light Gas Log Sets • 4004-300 Rev D • 05/08
5
H. Inspect the Appliance and Components
• Remove the contents from the carton labeled “Burner”.
Attached to the burner are tags identifying the manufacturer
name, serial number, model number (including gas log
size), BTU ratings, gas type, etc.
• Review the attached tags before proceeding. Ensure
that all minimum replace dimension requirements are
achieved using Table 3. See Figure 1. Ensure the gas
type provided in the replace coincide with the gas type
marked on the tag.
Figure 1 Measure Firebox
I. For Natural Gas Installation
• Pour sand into the burner pans to the point where the
burner pipe is covered. See Figure 3. Level the sand from
right to left to ensure an even ame pattern. At this point
the pan should be half full.
Figure 3 Sand
.Pour vermiculite over the sand in the pans until they are
full. See Figure 4.
• The burner is assembled with the controls installed at the
factory and is designed to connect one end of the 3/8 in.
supply line before placing inside the replace. Ensure the
connection is tightened using a 3/4 in. wrench.
• Place the burner towards the rear and center of the
replace and connect to the gas line. Follow instructions
in “F. Gas Pressure” to check for gas leaks.
• Install the grate by placing the inserts (attached to the
grate) into the slots provided in the burner pan. Slide the
inserts into the slots (See Figure 2) and push the grate
as far as possible to the locked position.
Figure 2 Placing Grate
Figure 4 Placing Vermiculite
Note: For best results, do not pack down the rock wool.
The placement of rock wool can have an effect on ame
pattern and may need to be adjusted to achieve a desired
appearance.
6
Hearth & Home Technologies • Grand Oak Match Light Gas Log Sets • 4004-300 Rev D • 05/08
Figure 5 Placing Rock Wool
Damper
Stop Clamp
Damper
• Remove the Platinum Bright Embers™ from the package.
For optimum performance peel each piece apart in layers
and lightly place on top of the vermiculite and rock wool
where the ame is blue. This will achieve the desired
realism.
• The gas burns at the point of the least resistance. In
case of an uneven ame pattern it may be necessary to
adjust the materials in the pans (using an object such as
a screwdriver) to achieve the desired effect.
• Place desired amount of lava granules on the oor of the
replace. DO NOT ALLOW THE GRANULES TO COME
IN CONTACT WITH THE FLAMES. (Lava granules may
contain moisture which, when heating, may cause it to pop
out during installation and set-up.) Ensure the controls
and switches are unobstructed after the granules are
installed.
• Place logs. See Sections L Thru S.
• Place accent logs around burner on oor of replace.
J. Damper Stop Installation Instructions
Included in the burner assembly box is a damper stop clamp
which attaches to the damper as shown (Figure 6). Install
the clamp to the damper ensuring that the minimum requirements (Tables 1 and 2) are achieved. Use a 7/16 in. wrench
to secure the clamp to the damper. If the damper clamp pro-
vided does not t your application, other means of securing
the proper opening must be provided by the installer.
Figure 6 Damper Stop Clamp
WARNING
Fire Risk
Explosion Risk
Personal Injury Risk
Failure to position the parts in accordance
with the diagrams provided with the log
pa ckages or fail ure to use only parts
approved with this appliance may result in
property damage or personal injury.
Hearth & Home Technologies • Grand Oak Match Light Gas Log Sets • 4004-300 Rev D • 05/08
Note: The state of Massachuset ts requires that the
chimney ue damper, when used with gas logs, be welded
open or completely removed. In the Commonwealth of
Massachusetts this appliance must be installed by a
licensed plumber or gastter.
7
K. Inspect the Venting System
The replace venting system is designed and constructed to
develop a positive ow adequate to remove ue gases to the
outside atmosphere. See replace installation instructions.
A spillage test must be made before the installed
appliance is left with the consumer.
• Close all doors and windows in the home.
• Light the log set (see Lighting Instructions).
• After three minutes, test with a smoke match, smoke
candle, stick incense or cigarette 1 in. below the top of
the opening (lintel) moving across the full width. If spillage
(smoke down into the room) occurs, it will most likely be
near the top, outside corners.
Possible cures if spilling occurs:
• The damper needs to be opened further.
• The replace opening needs to be reduced by adding a
drop panel across the top under the lintel.
• The air supply from outdoors needs to be increased. Open
the outside air kit if the appliance is so equipped, or crack
open a door or window.
• If necessary, seek expert advice. Do not operate this
appliance.
Cleaning
• Periodic examination and cleaning of the venting system
of the replace should be done before initial use and at
least annually by a qualied agency.
8
Hearth & Home Technologies • Grand Oak Match Light Gas Log Sets • 4004-300 Rev D • 05/08