Hearth and Home Technologies GFK-160A User Manual

GFK-160A Blower System
PLATE
110-120 VAC
- Installation and Operating Instructions -
1.0 INTRODUCTION
The GFK-160A Blower has been designed to circulate room air through the fireplace to enhance heat output. The GFK160A blower system operates on 120 VAC, 60 Hz power. This is available through a receptacle in the factory installed junc­tion box. The junction box is located in the controls com­partment of the fireplace.
2.0 CHECK CONTENTS OF SHIPPING CARTON
Compare CONTENTS OF CARTON in Figure 1 with the ac­tual parts received. If any parts are missing or damaged, contact your dealer before starting installation. Do not in­stall a damaged blower kit.
BLOWER
CONTROL
KNOB
WARNING: DO NOT CONNECT 110-120 VAC WIRING TO THE GAS CONTROL VALVE OF THIS FIREPLACE.
4.0 INSTALLATION INSTRUCTIONS
4.1 INSTALLING ELECTRICAL SERVICE TO THE JUNCTION BOX
WARNING: TURN ELECTRICAL POWER OFF AT THE CIRCUIT BREAKER BEFORE BEGINNING THIS INSTAL­LATION.
1. Remove the electrical cover plate from the lower exterior
of the fireplace. Remove the knock-out from the plate and attach the Romex clamp (screws to the outside). (See Figure 2). NOTE: Some fireplace models have a round hole through which the service wires are fed and into which the Romex clamp is attached. These models do not have a cover plate.
GROUND
FIGURE 1
CLIP
CONTROL
NUT
SPEED
CONTROL
TEMP.
SENSOR
SWITCH
WING
NUT
3.0 INSTALLATION PRECAUTIONS
The GFK-160A Blower Kit is tested and safe when installed in accordance with this installation manual. It is your respon­sibility to read all instructions before starting installation and to follow these instructions carefully during installation to as­sure maximum benefit from, and safe operation of, the blower.
This blower is carefully engineered and must be installed only as specified. If you modify it or any of its components, you may cause a fire hazard and will void the WARRANTY. In addition, such action may void the coverage provided by the owner's home insurance.
CAUTION: All wiring should be done by a qualified electri­cian and shall be in compliance with local codes and with the National Electric Code ANSI/NFPA NO. 70-current (in the United States), or with the current CSA C22.1 Canadian Electric Code (in Canada).
LOWER GRILLE
FIGURE 2
COVER
2. Feed the 110-120 VAC electrical service wires through
the Romex clamp and secure the wires to the clamp. Reattach the cover plate to the outside of the fireplace.
3. Access the controls compartment of the fireplace to lo-
cate the Junction Box.
4. Using the wire nuts, attach the black wire to the black ser-
vice wire, the white wire to the white service wire, and the service ground wire to the ground stud of the junction box.
5. Attach the junction box to the side of the unit. Insert the
rear tab of the box into the rectangular slot in the outer wrap of the firebox. Push the front end of the box tightly against the side of the unit, and secure the box with a sheet metal screw (note the hole in the front end tab).
Printed in U.S.A. Copyright 2003 Hearth & Home Technologies Inc., 20802 Kensington Blvd., Lakeville, MN 55044
107-981K 5/03
4.2 INSTALLING THE BLOWER
RECEPTACLE
NOTE: SOME MODELS MAY HAVE
A SEPARATE MOUNTING LOCATION
FIREPLACE
1/8” TO 1/4”
WING
TEMPERATURE
SENSOR SWITCH
Position the blower all the way to the rear and center in the fireplace. Pull the blower forward 1/8" to 1/4" from the back wall of the fireplace (Figure 3). Plug the blower cord into the blower receptacle FAN on the junction box. Attach the ground wire to the bottom of the junction box or to a good accessible metal grounded source. Note: You can attach this to the firebox leg.
METAL STYLE JUNCTION BOX
BLOWER
ON THE BASE PAN OR VALVE
BRACKET FOR MOUNTING THIS
SPEED CONTROL
SENSOR
SWITCH
“FAN”
SPEED
CONTROL
4.3 INSTALLING THE SPEED CONTROL
AND SENSOR SWITCH
1. Remove the knob and locknut from the variable speed
control. Slide the control behind the fireplace wall, in the lower right front corner, with the stem sticking out of the pre-punched hole. Attach the locknut tightly and reat­tach the knob on the stem.
NOTE: Some models may have a separate mount­ing location on the base pan or valve bracket for mounting this speed control.
2. Slide the temperature sensor switch/bracket assembly
onto the weld stud on the outside of the combustion cham­ber. Secure the bracket assembly with the wing nut pro­vided. See Figure 4.
NOTE: The weld stud is located either on the lower right side or the bottom of the combustion box.
POWER STRIP STYLE JUNCTION BOX
BLOWER
SENSOR
SWITCH
“FAN”
RECEPTACLE
SPEED
CONTROL
WALL
BLOWER
NUT
SPEED
CONTROL
FIGURE 4
NOTE: THE SWITCH/BRACKET ASSEMBLY MUST BE
INSTALLED SO THAT THE SENSOR SWITCH IS TO­WARDS THE TOP OF THE UNIT .
3. Connect the variable speed control and the temperature
sensor switch to the junction box with the wires provided. See Figure 5 for the wiring diagram that matches the style of junction box on the fireplace.
4. Turn the 110-120 VAC service "ON" at the circuit breaker
and turn the speed control switch to the "ON" position.