GFK-160A Blower System
- Installation and Operating Instructions -
1.0 INTRODUCTION
The GFK-160A Blower has been designed to circulate room
air through the fireplace to enhance heat output. The GFK160A
blower system operates on 120 VAC, 60 Hz power. This is
available through a receptacle in the factory installed junction box. The junction box is located in the controls compartment of the fireplace.
A variable speed control is provided with the blower system
to provide quiet forced air flow at the desired speeds. A temperature sensor switch, which automatically turns the blower
ON/OFF, is also provided with this kit.
2.0 CHECK CONTENTS OF SHIPPING CARTON
Compare CONTENTS OF CARTON in Figure 1 with the actual parts received. If any parts are missing or damaged,
contact your dealer before starting installation. Do not install a damaged blower kit.
BLOWER
CONTROL
KNOB
WARNING: DO NOT CONNECT 110-120 VAC WIRING TO
THE GAS CONTROL VALVE OF THIS FIREPLACE.
4.0 INSTALLATION INSTRUCTIONS
4.1 INSTALLING ELECTRICAL SERVICE
TO THE JUNCTION BOX
WARNING: TURN ELECTRICAL POWER OFF AT THE
CIRCUIT BREAKER BEFORE BEGINNING THIS INSTALLATION.
1. Remove the electrical cover plate from the lower exterior
of the fireplace. Remove the knock-out from the plate
and attach the Romex clamp (screws to the outside).
(See Figure 2). NOTE: Some fireplace models have a
round hole through which the service wires are fed and
into which the Romex clamp is attached. These models
do not have a cover plate.
GROUND
FIGURE 1
CLIP
CONTROL
NUT
SPEED
CONTROL
TEMP.
SENSOR
SWITCH
WING
NUT
3.0 INSTALLATION PRECAUTIONS
The GFK-160A Blower Kit is tested and safe when installed
in accordance with this installation manual. It is your responsibility to read all instructions before starting installation and
to follow these instructions carefully during installation to assure maximum benefit from, and safe operation of, the blower.
This blower is carefully engineered and must be installed
only as specified. If you modify it or any of its components,
you may cause a fire hazard and will void the WARRANTY.
In addition, such action may void the coverage provided by
the owner's home insurance.
CAUTION: All wiring should be done by a qualified electrician and shall be in compliance with local codes and with
the National Electric Code ANSI/NFPA NO. 70-current (in
the United States), or with the current CSA C22.1 Canadian
Electric Code (in Canada).
LOWER
GRILLE
FIGURE 2
COVER
2. Feed the 110-120 VAC electrical service wires through
the Romex clamp and secure the wires to the clamp.
Reattach the cover plate to the outside of the fireplace.
3. Access the controls compartment of the fireplace to lo-
cate the Junction Box.
4. Using the wire nuts, attach the black wire to the black ser-
vice wire, the white wire to the white service wire, and the
service ground wire to the ground stud of the junction box.
5. Attach the junction box to the side of the unit. Insert the
rear tab of the box into the rectangular slot in the outer
wrap of the firebox. Push the front end of the box tightly
against the side of the unit, and secure the box with a
sheet metal screw (note the hole in the front end tab).
Printed in U.S.A. Copyright 2003
Hearth & Home Technologies Inc., 20802 Kensington Blvd., Lakeville, MN 55044
107-981K 5/03
4.2 INSTALLING THE BLOWER
NOTE: SOME MODELS MAY HAVE
A SEPARATE MOUNTING LOCATION
Position the blower all the way to the rear and center in the
fireplace. Pull the blower forward 1/8" to 1/4" from the back
wall of the fireplace (Figure 3). Plug the blower cord into the
blower receptacle FAN on the junction box. Attach the
ground wire to the bottom of the junction box or to a good
accessible metal grounded source. Note: You can attach
this to the firebox leg.
METAL
STYLE
JUNCTION
BOX
BLOWER
ON THE BASE PAN OR VALVE
BRACKET FOR MOUNTING THIS
SPEED CONTROL
SENSOR
SWITCH
“FAN”
SPEED
CONTROL
4.3 INSTALLING THE SPEED CONTROL
AND SENSOR SWITCH
1. Remove the knob and locknut from the variable speed
control. Slide the control behind the fireplace wall, in the
lower right front corner, with the stem sticking out of the
pre-punched hole. Attach the locknut tightly and reattach the knob on the stem.
NOTE: Some models may have a separate mounting location on the base pan or valve bracket for
mounting this speed control.
2. Slide the temperature sensor switch/bracket assembly
onto the weld stud on the outside of the combustion chamber. Secure the bracket assembly with the wing nut provided. See Figure 4.
NOTE: The weld stud is located either on the lower right
side or the bottom of the combustion box.
POWER STRIP
STYLE
JUNCTION
BOX
BLOWER
SENSOR
SWITCH
“FAN”
RECEPTACLE
SPEED
CONTROL
WALL
BLOWER
NUT
SPEED
CONTROL
FIGURE 4
NOTE: THE SWITCH/BRACKET ASSEMBLY MUST BE
INSTALLED SO THAT THE SENSOR SWITCH IS TOWARDS THE TOP OF THE UNIT .
3. Connect the variable speed control and the temperature
sensor switch to the junction box with the wires provided.
See Figure 5 for the wiring diagram that matches the
style of junction box on the fireplace.
4. Turn the 110-120 VAC service "ON" at the circuit breaker
and turn the speed control switch to the "ON" position.