Hearth and Home Technologies CB1200I-B User Manual

CB1200-I PELLET INSERT
OMNI-Test Laboratories, Inc.
R
Owner’s Manual
Installation and Operation
CB1200I-B
DO NOT DISCARD THIS MANUAL
• Important operating and maintenance instruc­tions included.
WARNING
Please read this entire manual before installation and use of this pellet fuel-burning room heater. Failure to follow these instructions could result in property damage, bodily injury or even death.
Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this or any other appliance.
• Do not overfire - If any external part starts to glow, you are overfiring. Reduce feed rate. Overfiring will void your warranty.
• Comply with all minimum clearances to com bustibles as specified. Failure to comply may cause house fire.
Read, understand and follow these instruc­tions for safe installa­tion and operation.
NOTICE
Hot glass will cause burns.
• Do not touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
• Alert children and adults to hazards of high
-
High temperatures may ignite clothing or other
• Keep clothing, furniture, draperies and other flammable
Leave this manual with party responsible for use and operation.
WARNING
fireplace.
temperatures.
flammable materials.
materials away.
Tested and
Listed by
O-T L
C
HOT SURFACES!
Glass and other surfaces are hot during operation AND cool down.
Portland
Oregon USA
US
DO NOT
DISCARD
Tested and approved for wood pellets and shelled field corn fuel only. Burning of any other type of fuel voids your warranty.
www.quadrafire.com
CAUTION
Check building codes prior to installation.
• Installation MUST comply with local, regional, state and national
• Consult local building, fire officials or authorities having jurisdic-
7014-083E
CAUTION
codes and regulations.
tion about restrictions, installation inspection, and permits.
September 1, 2008
CB1200-I Pellet Insert
CAUTION:
2
R
and Welcome to the Quadra-Fire Family!
Hearth & Home Technologies welcomes you to our tradition of excellence! In choosing a Quadra-Fire appliance, you have our assurance of commitment to quality, durability, and performance.
This commitment begins with our research of the market, including ‘Voice of the Customer’ contacts, ensuring we make products that will satisfy your needs. Our Research and Development facility then employs the world’s most advanced technology to achieve the optimum operation of
our stoves, inserts and fireplaces. And yet we are old-fash­ioned when it comes to craftsmanship. Each unit is meticu­lously fabricated and surfaces are hand-finished for lasting beauty and enjoyment. Our pledge to quality is completed as each model undergoes a quality control inspection. From design, to fabrication, to shipping:
We wish you and your family many years of enjoyment in the warmth and comfort of your hearth appliance. Thank you for choosing Quadra-Fire.
CLEARANCE TO COMBUSTIBLES LABEL LOCATED INSIDE HOPPER LID
SERIAL NUMBER & MANUFACTURE DATE LABEL LOCATED UNDER TOP ON INSIDE OF HOPPER BODY
HOT WHILE IN OPERATION DO NOT TOUCH. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS. SEE NAMEPLATE AND INSTRUCTIONS. Operate this unit with fuel hopper lid closed. Failure to do so may result in emissions products' combustion from the hopper under certain conditions. Maintain hopper seal in good condition. Do no over fill the hopper.
ATTENTION:
CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L'ESPACE DÉSIGNÉ DE L'INSTALLATION. LE CONTACT PEUT CAUSER DES BRÛLURES À LA PEAU. VOIR L'ÉTIQUETTE ET LES INSTRUCTIONS. Opérez cet appareil avec le couvercle de la trémie fermé. Le défaut de ne pas suivre les instructions peut résulter, sous certaines conditions, en une combustion des émissions des produits venant de la trémie. Ne pas remplir la trémie trop pleine.
Safety and clearance section located on inside of hopper lid./Serial Number section located under top on inside of hopper body.
La section se réfé dux distances et mescres de sécurité est située à l'intérieut du couvércle de la tré la bôitre à feu.
Tested and
O-T L
Listed by
C
OMNI-Test Laboratories, Inc.
Listed Solid Fuel Room Heater/Pellet Type Insert. Also suitable for Mobile Home Installation. This appliance has been tested and listed for use in Manufactured Homes in accordance with OAR 814-23-9000 through 814-23-909.
Tested to: ASTM E1509-95, UL127, ULC S628-93, ULC S610-M87, ULC/ORD C1482-M1990, Room Heating Pellet Burning Type, (UM) 84-HUD FOR USE
ONLY WITH PELLETIZED WOOD OR SHELLED FIELD CORN FUEL. Input Rating Maximum 5.5 lb fuel/hr. Electrical Rating: Route power cord away from unit. Do not route cord under or in front of appliance.
Risk of electrical shock. Disconnect power supply before
DANGER:
servicing. Replace glass only with 5mm ceramic available from your dealer. To start, set thermostat above room temperature, the stove will light automatically. To shutdown, set thermostat to below room temperature. For further instruction refer to owner's manual tightly closed during operation.
Portland
Oregon USA
US
115 VAC, 60 Hz, Start 4.1 Amps, Run 1.1 AMPS.
Report / Rapport #061-S-13-2
.
Keep viewing and ash removal doors
La section du numéro de série est située en dessous du couvercle à l'intérieur de la trémie.
1200-I Pellet Insert
Appareil de chauffage inséré de combustible solide/de type de boulettes. Accepté dans l'installation dans les maisons mobiles. Cet appareil a été testé et enregistré pour
'usage dans les Maisons Mobiles en accord avec OAR 814-23-9000 jusqu'à 814-23-909.
l
Testé à: ASTM E1509-95, UL127, ULC628-M93, ULC S610-M87, ULC/ORD C1482-M1990, Room Heating Pellet Burning Type, (UM) 84-HUD POUR USAGE AVEC LES BOULETTES DE BOIS OU DE COMBUSTIBLE DE MAIS ÉCOSSÉ DES CHAMPS. Consommahon maximale à l'entrée (sans pertes) 2.5 kg/h. Puissance Électrique: 115 VAC, 60 Hz, Début 4.1 Amps, Courir 1.1 Amps, Éloignez le fil électrique de l'appareil. Ne pas faire passer le fil électrique au dessus ou en dessous de l'appareil. DANGER: Il y a risque de décharge électrique. Déconnectez le fil électrique de la prise de contact avant le service. Remplacez la vitre seulement avec une vitre céramique de 5 mm disponible chez votre fournisseur. Pour allumer, monter la température du thermostat au dessus de la température de la pièce, le poêle s'allumera automatiquement. Pour éteindre, descendre la température du thermostat en dessous de la température de la pièce. Pour des instructions supplémentaires, référez vous au manuel du propriétaire. Gardez la porte d'ouverture et la porte des cendres fermées hermétiquement durant l'opération.
R
1445 Highway North, Colville, WA 99114
www.quadrafire.com
Test Lab & Report No.
Model Name
MANTEL
B
C
SIDE WALL
A
E
U.S. ENVIRONMENTAL PROTECTION AGENCY OMNI Test Laboratories, Inc., Beaverton, Or Report/Rapport 061-S-12-2
This model is exempt from EPA certification under 40 CFR 60.531 by definition [Wood Heater (A) "Air-to-Fuel Ratio"].
008 2009 2010 JAN FEB MAR APR MAY JUNE JULY AUG SEPT OCT NOV DEC
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ÉTIQUETTE
Page 2
D
Masonry or Zero Clearance Minimum Clearances to Combustible
Maçonnene ou zéro distance foyer distances minimales à tout matériel combustible.
A Louvers to combustible wall B Insert top to mantel C Front Facing
SAMPLE
D* Hearth Extension - Front E* Hearth Extension - Side
*See hearth protection note above
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ÉTIQUETTE
6” (152mm) 12” (305mm) 3” (76mm) 6" (152mm) 8” (203mm)
A Lucarne au mur combustible B Dessus de l'insert à la tablette de cheminée C Revêtement facial D* Protechion de sol - frontal E* Protechon ole sol - côté
*Voir les notes sur la protechion ole sol ci-dessus.
QUADRA-FIRE
1200-I PELLET INSERT
SERIAL NO.
7014-080C
/ NUMÉRO DU
152mm 305mm 76mm 152mm 203mm
007C
Made in China/Fait Aux Chine
7014-080C
7014-083E
Manufactured Date
Serial Number
September 1, 2008
R
CB1200-I Pellet Insert
TABLE OF CONTENTS
Section 1: Listing and Code Approvals
A. Appliance Certifications ...................... 4
B. Mobile Home Approved ......................4
C. Glass Specifications ............................4
D. Electrical Rating ..................................4
E. BTU & Efficiency Specifications .......... 4
A. Design, Installation & Location
Section 2: Getting Started
Considerations ....................................5
B. Fire Safety ..........................................5
C. Tools & Supplies Needed ...................6
D. Inspect Appliance, Components
and Pre-Check List .............................6
Section 3: Dimensions & Clearances
A. Appliance Dimensions ........................ 7
B. Clearances to Combustibles
As A Built-In, UL and ULC ..................8
C. Clearances to Combustibles,
Masonry & Zero Clearance ................. 9
D. Minimum Opening for Factory
Built Fireplace ..................................... 9
E. Masonry Minimum Opening ................10
F. Floor Protection ..................................10
G. Calculating Alternate Floor
Protection Material ..............................10
H. Removing Floor of Factory Built
Fireplace ............................................. 11
Section 8: Operating Instructions
A. Fuel Size & Material ............................ 25
B. General Operation Information ...........25
C. Before Your First Fire .........................26
D. Starting Your First Fire ........................26
E. Fire Characteristics .............................26
F. Feed Rate Adjustment .......................26
G. Ignition Cycles ....................................26
H. Frequently Asked Questions...............27
Section 9: Troubleshooting ............................28-30
Section 10: Maintaining & Servicing Appliance
A. Proper Shutdown Procedure ...............31
B. Quick Reference Maintanence Chart .. 31
C. General Maintenance & Cleaning .......31-34
D. High Ash Content Maintenance ..........35
E. Glass Replacement ............................. 36
F. Igniter Replacement ............................37
G. Baffle Removal ....................................37
Section 12: Reference Material
A. Component Functions.........................38-39
B. Component Locations .........................40
C. Exploded Drawings .............................41-42
D. Service Parts & Accessories...............43-45
E. Warranty Policy ...................................46-47
F. Contact Information ............................48
Section 4: Vent Information
A. Chimney & Exhaust Connections ........12
B. Venting Termination Requirements ....12
C. Equivalent Feet of Pipe.......................13
D. Pipe Selection Chart ...........................13
Section 5: Venting Systems
A. Direct Connect with Outside Air ..........14
B. Direct Connect without Outside Air ..... 14
C. Full Reline with Outside Air .................15
Section 6: Mobile Home .................................. 16
Section 7: Appliance Set-Up
A. Rear Shroud Installation .....................17-18
B. Outside Air Kit .....................................19
C. Adjustable Hopper Option...................19
D. Grille Installation .................................19
E. Adjustable Hearth Support..................20
F. Panel & Trim .......................................21-22
G. Brick Set Installation ...........................23
H. Brick Clip Installation ...........................23
I. Log Set Placement ..............................24
J. Thermostat Installation ........................24
Septemer 1, 2008
7014-083E
Page 3
CB1200-I Pellet Insert
Listing and Code Approvals
1
R
A. Appliance Certification
MODEL: 1200-I Pellet Insert
LABORATORY: OMNI Test Laboratories, Inc
REPORT NO. 061-S-13-2
TYPE: Solid Fuel Room Heater/Pellet Fuel
Burning Type Insert
STANDARD: ASTM E1509-95, ULC S628-93, ULC
S610-M87, ULC S628-M93 and ULC/ ORD-C1482-M1990 Room Heater Pellet Fuel Burning Type and (UM) 84-HUD, Mobile Home Approved
B. Mobile Home Approved
This appliance is approved for mobile home installations when not installed in a sleeping room and when an outside combustion air inlet is provided. The structural integrity of the mobile home floor, ceiling, and walls must be maintained.
The appliance must be properly grounded to the frame of the mobile home and use only listed pellet vent, Class “L” or “PL” connector pipe. A Quadra-Fire Outside Air Kit must be installed in a mobile home installation.
E. BTU & Efficiency Specifications
Emissions Rating: .9 grams/hr
*BTU Output: 14,000 - 40,000 / hr
Heating Capacity: up to 2,500 sq. ft. depending
on climate zone
Hopper Capacity: 60-75 lbs
Fuel: Wood Pellets or Shelled Corn
*BTU output will vary, depending on the brand of fuel you use in your appliance. Consult your Quadra-Fire dealer for best results.
NOTE: Hearth & Home Technologies, manufacturer of this appliance, reserves the right to alter its products, their specifications and/or price without notice.
C. Glass Specifications
This appliance is equipped with 5mm ceramic glass. Replace glass only with 5mm ceramic glass. Please contact your dealer for replacement glass.
NOTE: This installation must conform with local codes. In the absence of local codes you must comply with the ASTM
E1509-95, ULC S628-93, ULC S610-M87, ULC/ORD-C­1482-M1990, (UM) 84-HUD.
D. Electrical Rating
115 VAC, 60 Hz, Start 4.1 Amps, Run 1.1 Amps
Page 4
7014-083E
September 1, 2008
R
CB1200-I Pellet Insert
2
A
. Design, Installation & Location
Getting Started
Considerations
1. Appliance Location
Consideration must be given to safety, convenience, traffic flow, and the fact that the appliance will need a chimney and chimney connector. It is a good idea to plan your installation on paper, using exact measurements for clearances and floor protection, before actually beginning the installation.
If you are not using an existing chimney, place the appliance in a location to maintain a clear passage for the installation of any listed and approved pellet venting system. This appli­ance may be vented vertically or horizontally.
Maintain specified vent clearance to comubstible require­ments listed by the pellet manufactures venting instructions and all clearance to combustivles listed in this manual.
Check with your local building code agency before you begin your installation. Be sure local building codes do not super­sede UL specifications and always obtain a building permit so that insurance protection benefits cannot be unexpectedly cancelled. If any assistance is required during installation, please contact your local dealer.
We recommend that a qualified building inspector and your insurance company representative review your plans before and after installation.
2. Thermostat Location
The thermostat’s location will have some effect on the appliance’s operation. When the thermostat is located close to the appliance, it may require a slightly higher temperature setting to keep the rest of the house comfortable. If the thermostat location is in an adjacent room or on a different floor level, you will notice higher temperatures near the appliance.
B. Fire Safety
Maintain the designated clearances to combustibles. Insu­lation must not touch the chimney. You must maintain the designated air space clearance around the chimney. This space around a chimney is necessary to allow natural heat removal from the area. Insulation in this space will cause a heat buildup, which may ignite wood framing. NOTE:
Clearances may only be reduced by means approved by the regulatory authority having jurisdiction.
To provide reasonable fire safety, the following should be given serious consideration:
1. Install at least one smoke detector on each floor of your home to ensure your safety. They should be located away from the heating appliance and close to the sleeping areas. Follow the smoke detector manufacturer’s placement and installation instructions, and be sure to maintain regularly.
2. A conveniently located Class A fire extinguisher to contend with small fires resulting from burning embers.
3. A practiced evacuation plan, consisting of at least 2 escape routes.
4. A plan to deal with a hopper fire as follows:
In the event of a hopper fire:
a. Evacuate the house immediately. b. Notify fire department.
CAUTION
• Do NOT connect this unit to a chimney flue servicing another appliance.
• Do NOT connect to any air distribution duct or system.
Septemer 1, 2008
7014-083E
WARNING
Fire Risk.
• Do not operate appliance before reading and understanding operating instructions.
• Failure to operate appliance properly may cause a house fire.
Page 5
CB1200-I Pellet Insert
R
C. Tools And Supplies Needed
Tools and building supplies normally required for installation, unless installing into an existing masonry fireplace:
Reciprocating Saw Hammer Phillips Screw driver Tape Measure
Safety Glasses Framing Square Electric Drill & Bits (1/4”)
1/4” Self-Tapping Screws Plumb Line Level Framing Material Hi-temp Caulking Material
May also need:
Vent Support Straps
Venting Paint Gloves
WARNING
Inspect appliance and components for damage. Damaged parts may impair safe operation.
• Do NOT install damaged components.
• Do NOT install incomplete components.
• Do NOT install substitute components.
Report damaged parts to dealer.
WARNING
Fire Risk.
Hearth & Home Technologies disclaims any responsibility for, and the warranty will be voided by, the following actions:
• Installation and use of any damaged appliance.
• Modification of the appliance.
• Installation other than as instructed by Hearth & Home Technologies.
• Installation and/or use of any component part not approved by Hearth & Home Technologies.
• Operating appliance without fully assembling all components.
• Do NOT Overfire.
Or any such action that may cause a fire hazard.
D. Inspect Appliance & Components and
Pre-Use Check List
1. Place the appliance in a location near the final installation area and follow the proce­dures below:
2. Open the appliance and remove all the parts and articles packed inside the Component Pack. Inspect all the parts and glass for ship­ping damage. Contact your dealer if any irregu­larities are noticed.
3. All safety warnings have been read and fol­lowed.
4. This Owner’s Manual has been read.
5. Floor protection requirements have been met.
6. Venting is properly installed.
7. The proper clearances from the appliance and chimney to combustible materials have been met.
8. The masonry chimney is inspected by a profes­sional and is clean, or the factory built metal chimney is installed according to the manufac­turer’s instructions and clearances.
9. The chimney meets the required minimum height.
10.
11. Plated surfaces have been wiped clean, if
12. Thermostat or remote has been installed.
13. A power outlet is available nearby.
All labels have been removed from the glass door.
applicable.
Page 6
7014-083E
September 1, 2008
R
Dimensions and Clearances
3
A. Appliance Dimensions
40" (1016mm)
29-1/4" (743mm)
22" (559mm)
8-3/4"
(222mm)
CB1200-I Pellet Insert
B
10-3/4"
(273mm)
Figure 7.1 - Top View
13" (330mm)
A
12" (305mm)
28-1/2" (724mm)
Figure 7.2 - Front View
Panel A B
Standard 30 inches (762mm) 40 inches (1016mm)
Large 33 inches (838mm) 50 inches (1270mm)
12"
(305mm)
13"
(330mm)
10-3/4"
(273mm)
Figure 7.3 - Side View
Septemer 1, 2008
30" (762mm)
22" (559mm)
(Hopper Up)
19-1/2" (495mm)
(Hopper Down)
11"
(279mm)
7014-083E
25-1/2"
(648mm)
11"
(279mm)
Page 7
CB1200-I Pellet Insert
B. Clearance To Combustibles, UL and ULC
AS A BUILT-IN
Rear Shroud Kit, Part 811-0680 is Required for Built-In Installation
(see pages 17-18 for installation instructions)
R
A
B
C
D
C
0 INCH (0mm) CLEARANCE TO EXPOSED SECTION AND FACE TRIM
Figure 8.1
Inches Millime-
A Top of Shroud Top Vent 3.0 76
Rear Vent 0 0
B Sides of Inside Shroud Top or Rear Vent 0 0
C Back of Inside Shroud Top Vent 2.5 64
Rear Vent 0 0
D Vent Pipe to Combustible Top or Rear Vent 3.0 76
E From Outside Edge of
Panel Set to Combustibles
B
E
0 0
INSTALLED AS A BUILT-IN UNIT
Shown with Rear Vent and Optional Outside Air
Combustible Mantel
Shown with Hopper Extended
12 in
Rear Shroud
Figure 8.2
6 in
Optional Outside Air
WARNING
Fire Risk. Comply with all minimum clear-
ances to combustibles as speci­fied.
Failure to comply may cause house fire.
NOTE:
Illustrations reflect typical installations
and are FOR DESIGN PURPOSES ONLY.
Illustrations/diagrams are not drawn to
scale.
Actual installation may vary due to
individual design preference.
Page 8
7014-083E
September 1, 2008
R
C. Minimum Clearances To Combustibles for
Masonry and Zero Clearance Fireplaces
MANTEL
Face Trim
B
C
SIDE WALL
A
CB1200-I Pellet Insert
Inches Millimeters
A Louvers to combustible
side wall
B Insert top to mantel 12 305
C Top to Face Trim 3 76
D Hearth Extension - Front 6 153
E Hearth Extension - Sides 8 203
6 153
E
D
Figure 9.1
D. Minimum Opening for Masonry and Zero
Clearance Fireplaces for Built-In Using Rear Shroud
NOTE: A Quadra-Fire floor protector (Part 811-0730) is
available through your dealer to be used as a floor protector for the section under the insert body only. Floor protection to front and sides of insert unit must be supplied in addition to this part.
Inches Millimeters
A Rear Width 22 558
B Depth 15-1/2 393
Height - Top Vent 25-1/2 647
C
*
Height - Rear Vent 22-1/2 571
D Front Width 29-1/4 743
Figure 9.2
Septemer 1, 2008
B
C
A
*The size of your floor protector choice must be
added to this dimension. If using Quadra-Fire floor protector, Part 811-0730, allow 1-1/2” (38mm).
D
7014-083E
Page 9
CB1200-I Pellet Insert
R
E. Masonry Minimum Opening
B
D
Location Inches Millimeters
A Rear Width 22 558
B Depth 13 330
C Height - Top Vent 19-1/2 495
D Front Width 29-1/4 743
C
A
F. Floor Protection
1. Zero Clearance Installations*
It is necessary to install a floor protection of non-combus­tible material with a R value of 3.0 (1 inch [25mm] minimum thickness with a “k” value of 0.58) or a 1 inch (25mm) air space between insert base and hearth.
2. Non-Zero Clearance Installations*
A non-combustible floor protector is required with a mini­mum R value of 3.0 (1 inch [25mm] minimum thickness with a “k” value of 0.58) extending 6 inches (153mm) in front of the insert and 8 inches (203mm) to each side of the door opening.
* See alternate floor protection worksheet.
G. Calculating Alternate Floor Protection Material
Thermal Conductivity: k value
The k value indicates the amount of heat (in BTU’s) that will flow in 1 hour through 1 square foot of a uniform material 1 inch thick for each degree (F) of temperature difference from one side of the material to the other. The LOWER the k factor means less heat is being conducted through the non-combustible material to the combustible material beneath it. The k value of a material must be equal or smaller then the required k value to be accept­able. (BTU) (inch) (foot
Thermal Resistance: R value
The R value is a measure of a material’s resistance to heat transfer. R value is convenient when more than one materi­al is used since you can add the R values together, whereas you can not do this for k value. The HIGHER the R factor means less heat is being conducted through the non-com­bustible material to the combustible material beneath it. The R value of a material must be equal or larger then the re­quired R value to be acceptable.
Converting k to R:
Divide 1 by k and multiply the results times the thickness in inch­es of the material.
R = 1/k x inches of thickness
Converting R to k:
Divide the inches of thickness by R.
k = inches of thickness/R
Calculations:
Example: Floor protection requires k value of 0.84 and 3/4 inch thick.
Alternative material has a k value of 0.6 and is 3/4 inch thick.
Divide 0.6 by .75 = k value of 0.80. This k value is smaller than
0.84 and therefore is acceptable.
2
(hour) (oF)
Page 10
7014-083E
September 1, 2008
R
H. Removing Metal Floor of Factory-Built
Firebox
• The firebrick (refractory), glass doors, screen rails, screen mesh and log grates can be removed from a factory-built firebox in order to gain minimum insert opening requirements.
• Any smoke shelves, shields and baffles may be removed from a factory-built firebox if attached with mechanical fasteners.
• The metal floor of the factory-built firebox may be removed to facilitate the installation of the insert only when a 1 inch (25mm) airspace is provided between the insert and the floor of outer wrap.
• If the floor is made of thin metal, we recommend using a Quarda-Fire floor protector, Part 811-0730, which is available through your dealer.
CB1200-I Pellet Insert
Keep sharp edge of metal floor away from power cord
Figure 11.3. Place the insert into the fac­tory-built firebox. Ensure that the power cord can not be damaged by the sharp metal edge. You may need to cut out a notch to accommodate the cord.
Starter hole
Mark area of floor to cut
Figure 11.1. Measure and mark the metal floor for cutting. With a drill, make a starter hole in each corner.
Figure 11.2. Using a saws-all, cut out the floor.
Septemer 1, 2008
7014-083E
Page 11
CB1200-I Pellet Insert
Vent Information
4
A. Chimney and Exhaust Connection
1. Chimney & Connector: Use 3 or 4 inch (76-102mm)
diameter type "L" or "PL" venting system. It can be vented vertically or horizontally.
2. Mobile Home: Approved for all Listed pellet vent. Use
Listed double wall flue connector. A Quadra-Fire Outside Air Kit must be used with manufactured home installa­tions.
3. Residential: Use 24 gauge single wall flue connector or
Listed double wall flue connector to Class A Listed metal chimneys, or masonry chimneys meeting national and/or local codes for solid fuel appliances.
4. INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER.
5.
Secure exhaust venting system to the appliance with at least 3 screws. Also secure all connector pipe joints with at least 3 screws through each joint.
NOTE: All pipe must be welded seam pipe whenever pos­sible. Seal pipe joints with high temperature silicone (500°F [260°C] minimum rated only).
NOTE: If burning shelled field corn, you must use approved venting specifically designed for corn. Follow the instruc­tions from the venting manufacturer.
WARNING
Fire Risk.
• Only LISTED venting components may be used.
• NO OTHER vent components may be used. Substitute or damaged vent components may impair safe operation.
WARNING
Vent surfaces get HOT, can cause burns if touched. Non-combustible shielding or guards may be required
B. Venting Termination Requirements
CAUTION
Do not terminate vent in any enclosed or semi-enclosed
area such as a carport, garage, attic, crawl space, under a sun deck or porch, narrow walkway or closely fenced area, or any location that can build up a concentration of fumes such as a stairwell, covered breezeway, etc.
1. Termination must exhaust above air inlet elevation. It is
recommended that at least 60 inches (1524mm) of verti­cal pipe be installed when appliance is vented directly through a wall. This will create a natural draft, which will help prevent the possibility of smoke or odor venting into the home during a power outage. It will also keep exhaust from causing a nuisance or hazard by exposing people or shrubs to high temperatures. The safest and preferred venting method is to extend the vent vertically through the roof.
2. Distance from doors and opening windows, or gravity or
ventilation air inlets into building:
a. Not less than 48 inches (1219mm) below; b. Not less than 48 inches (1219mm) horizontally
from;
c. Not less than 12 inches (305mm) above.
3. Distance from permanently closed windows:
a. Not less than 12 inches (305mm) below, horizontally
from or above.
4. Distance between bottom of termination and grade
should be 12 inches (305mm) minimum. This is con­ditional upon plants in the area, and nature of grade surface. The grade surface must be a non-combustible material (i.e., rock, dirt). The grade surface must not be lawn. Distance between bottom of termination and public walkway should be 84 inches (2134mm) minimum.
5. Distance to combustible materials must be 24 inches
(610mm) minimum. This includes adjacent buildings, fences, protruding parts of the structure, roof overhang, plants and shrubs, etc.
6. Termination Cap Location (Home Electrical Service)
• Side-to-side clearance is to be the same as minimum clearance to vinyl inside corners.
Clearance of a termination cap below electrical service shall be the same as minimum clearance to vinyl soffits.
• Clearance of a termination cap above electrical service will be 12 inches (305mm) minimum.
• Location of the vent termination must not obstruct or interfere with access to the electrical service.
R
Page 12
7014-083E
September 1, 2008
R
CB1200-I Pellet Insert
C. Equivalent Feet of Pipe
The table below can help you calculate the equivalent feet of pipe which is a method used to determine pellet vent size. See
Figure 13.1.
Example of 3 Elbow-Rear Vent Termination Calculation
Pellet Venting
Component
90o Elbow or Tee
45o Elbow
Horizontal Pipe
Vertical Pipe
3 ft.
Figure 13.1
2 ft.
2 ft.
2 ft.
D. Pipe Selection Chart
The chart will help you in determing proper venting size according to the equivalent feet of pipe calcuated above and the altitude above sea level of this installa­tion. See Figure 13.2.
Locate the calculated equivalent feet of pipe on the vertical left side of the chart. Move to the right horizontally on the chart until you reach your altitude above sea level.
If you fall below the diagonal line, 3 or 4 inch (76 to 102mm) pipe may be used. If it is anywhere above the diagonal line, a 4 inch (102mm) diameter pipe is requried.
The chart reveals that a 90° elbow is 5 times as restrictive to the flow of exhaust gases under positive pressure as 1 foot of horizontal pipe, and a foot of horizontal pipe is twice as restrictive as a foot of vertical pipe.
Example 1
Equivalent Pipe
Length In Feet
Example 2
Figure 13.2
Example 1: If the equivalent length of pipe is 23 feet with altitude of
8,000 feet you must use 4 inch (102mm) diameter type “L” or “PL” vent.
Example 2: If the equivalent length of pipe is 12 feet with altitude of 6,000 feet you may use 3 or 4 inch (76 to 102mm) diameter type “L” or “PL” vent
WARNING
Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appli­ance. For assistance or additional information consult a qualified installer, service agency or your dealer.
# of
Elbows
Feet of
3X5 15
Note: This is a generic example and is not intended to represent any specific fuel type.
30
20
10
3 in. or 4 in. (76mm or 102mm) Diameter Pipe
0
1 2 3 4 5 6 7 8 9 10
MultipliedByEquivalent
Pipe
X 3
7X 1 7
2X 0.5 1
Total Equivalent Feet 23
4 in. (102mm) Diameter Pipe Only
Feet
Components
Equivalent Feet
ALTITUDE IN THOUSANDS OF FEET
Septemer 1, 2008
WARNING
Fire Risk.
Do NOT pack insulation or other combustibles between firestops.
• ALWAYS maintain specified clearances around venting and firestop systems.
• Install firestops as specified.
Failure to keep insulation or other material away from vent pipe may cause fire.
7014-083E
Page 13
CB1200-I Pellet Insert
Venting Systems
5
A. Direct Connect With Outside Air
NOTE: In Canada, only a full reline is
allowed per ULC S-628, ORD ULC C1482.
B.
NOTE; Use metal plate
around exhaust vent pipe and seal all edges with non-flammable insulation such as fiberglass, mineral wool or ceramic material.
Do not use high tempera­ture caulking materials to seal any edge to prevent future serviceability.
R
Direct Connect Without Outside Air
Outside Air through Rear Wall
Figure 14.1
NOTE:
Illustrations reflect typical installations and are FOR
DESIGN PURPOSES ONLY.
Illustrations/diagrams are not drawn to scale.
Actual installation may vary due to individual design
preference.
CAUTION
Never draw outside combustion air from:
• Wall, floor or ceiling cavity
• Enclosed space such as an attic or garage
Figure 14.2
WARNING
Fire Risk. Inspection of Chimney:
• Masonry chimney must be in good condition.
• Meets minimum standard of NFPA 211 Factory-built chimney must be 6 inch (152mm)
UL103 HT.
NOTE:
In Canada, where passage through a wall or partition of combustible construction is desired, the installation shall conform to CAN/CSA-B365.
Page 14
7014-083E
September 1, 2008
R
C. Full Reline With Outside Air
12” (305mm) min. above
12” (305mm) min. below
NOTE; Use metal plate around exhaust vent pipe and seal all edges with non-flammable insulation such as fiberglass, mineral wool or ceramic.
CB1200-I Pellet Insert
NOTE: Check clearances carefully for this
type of installation to ensure adequate room for outside air venting.
NOTE: In Canada, only a full reline is allowed per ULC S-628, ORD ULC C1482.
CAUTION
Check building codes prior to installation.
• Installation MUST comply with local, regional, state and national codes and regulations.
• Consult local building, fire officials or authorities having jurisdiction about restrictions, installa­tion inspection, and permits.
Do not use high temperature caulk­ing materials to seal any edge to prevent future serviceability
Outside Air Termination
at
Chimney Top
Figure 15.1
Septemer 1, 2008
Exit through the
Ash Clean-Out of
Masonry Chimney
Outside Air through Rear Wall
7014-083E
Page 15
Loading...