Hearth and Home Technologies BC36C User Manual

INSTALLATION & OPERATING
INSTRUCTIONS
BC36C, BC36R
WOODBURNING FIREPLACE
WARNING!
Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information, consult a qualified installer, service agency or the gas supplier.
08/04 34962 Rev G 1
BC36C/BC36R INSTALLATION INSTRUCTIONS
Table of Contents
Safety Precautions .......................................................................................................................................................... 2
Design and Installation Considerations ........................................................................................................................... 3
A. Listings and Code Approvals ........................................................................................................................................... 4
B. Description of the Fireplace System ................................................................................................................................ 4
C. System Components ....................................................................................................................................................... 5
D. Pre-Installation Preparation ........................................................................................................................................... 10
E. Chimney Requirements ................................................................................................................................................. 12
F. Installation of Fireplace ................................................................................................................................................. 15
G. Constructing a Chase .................................................................................................................................................... 22
H. Operating Instructions ................................................................................................................................................... 25
I. Maintenance Instructions .............................................................................................................................................. 29
Index .............................................................................................................................................................................. 31
Warranty ........................................................................................................................................................................ 32
CAUTION:
Do not expose the fireplace to the elements (i.e. rain, etc.) and keep the fireplace dry at all times. Wet insula­tion will produce an odor when the fireplace is used.
WARNING!
This fireplace is tested and listed for use only with the optional accessories listed in these instructions. Use of optional accessories not specifically tested for this appliance could void the warranty and/or result in a safety hazard.
Safety Precautions
1. Please read these installation instructions completely before beginning installation procedures. Failure to follow
them could cause a fireplace malfunction resulting in serious injury and/or property damage.
2. Always check your local building codes prior to installation. The installation must comply with all local, regional,
state and national codes and regulations.
3. An adequate supply of replacement combustion air from outside the house must be available to the fire for the
fireplace to operate properly. To achieve this, the use of the optional outside air kit is highly recommended.
In the event the home is unusually tightly sealed, the optional combustion air kit may not provide all the air required to support combustion. Hearth & Home Technologies is not responsible for any smoking or related problems that may result from the lack of adequate combustion air. It is the responsibility of the builder/contractor to ensure that adequate combustion air has been provided for the fireplace.
4. The fireplace must be installed with the Hearth & Home Technologies SL Series Chimney System.
The chimney system must always terminate outside the building. Be sure to follow all chimney specifications given in these installation instructions.
5. NEVER leave children unattended when there is a fire burning in the fireplace.
6. This fireplace is built for solid fuel only. NEVER use gasoline, gasoline type lantern fuel, kerosene, charcoal light
fluid, or similar liquids in this fireplace. Keep any flammable liquids a safe distance from the fireplace.
7. DO NOT use chimney cleaners or flame colorants in your fireplace.
8. The flue damper must be open at all times when the fireplace is in use.
9. While servicing this fireplace, always shut off any electricity or gas to the fireplace. This will prevent possible electric
shock or burns. Also, make sure the fireplace is completely cooled before servicing.
10. To ensure a safe fireplace system and to prevent the build up of soot and creosote, inspect and clean the fireplace
and chimney prior to use and periodically during the burning season. See “Maintenance Instructions” in this manual for cleaning instructions.
2 34962 Rev G 08/04
BC36C/BC36R INSTALLATION INSTRUCTIONS
DESIGN AND INSTALLATION CONSIDERATIONS
When selecting a location for your woodburning fireplace, it is important to evaluate a number of considerations. Modern construction techniques can create conditions that may not allow your chimney to draft properly. This may result in smoke spillage from your fireplace, as well as cause other combustion appliances to operate incorrectly.
Tightly sealed construction is important for energy efficiency. Unfortunately, a great deal of effort has been directed to tightening up sidewall construction, while considerably less attention has been paid to tightening upper portions of the warm air envelope (insulated ceilings). This has increased the “Stack Effect”, a condition that increases the negative pressure generated by the structure. This negative pressure will directly affect the drafting performance of a fireplace chimney. To minimize the negative pressure generated by stack effect, make certain that all ductwork installed in the attic spaces is sealed airtight. Minimize the number of recessed light fixtures installed in the insulated ceiling, and use sealed recessed light fixtures. Finally, make certain the whole house fans and attic access panels are tightly sealed. These are important design considerations that must be observed during the design and construction stage of the home.
If you desire to put a fireplace in your basement, we recommend that you consider a direct vent gas fireplace. Basements always have a significant negative air pressure that causes the fireplace system to be more susceptible to smoke spillage and cold flue backdrafting. Since direct vent gas fireplaces are sealed, they are not affected by the negative pressure that exists in basements.
Finally, woodburning fireplaces perform best when their chimney (roof termination) is located on the upper half of the roof, especially when cathedral ceilings are present. Chimneys that are located on the lower half of the roof realize what is known as “lazy flue” and will not draft as well as a chimney that is located in the upper portion of the roof. The reason for this is that the stack effect generated by the overall height of the living spaces inside the house will exceed the draft generated by the chimney system. If you desire to place a woodburning fireplace in a location where the termination cap would be located on the lower half of a roof, such as on an outside wall at the base of a cathedral ceiling, we recommend that you consider using a direct vent gas fireplace. This will assure the homeowner a fireplace that operates correctly.
These properties do not affect just your woodburning factory-built fireplace. They can cause any woodburning fireplace as well as any conventionally vented (B-vent) gas appliance to operate improperly. Careful planning at this stage of your project will ensure satisfaction with the operation of your fireplace once it is completed.
08/04 34962 Rev G 3
BC36C/BC36R INSTALLATION INSTRUCTIONS
A. LISTINGS AND CODE APPROVALS
This fireplace system has been tested and listed in accordance with UL 127 standards, and has been listed by Underwriters Laboratories Inc. for installation and operation in the United States.
This fireplace has been tested and listed for use with the optional components listed on page 5. These optional components may be purchased separately and installed at a later date. However, installation of an outside air kit will require significant reconstruction, and should be installed at the time of the initial fireplace installation.
Check with your local building code agency prior to installing this fireplace to ensure compliance with local codes, including the need for permits and follow-up inspections. If you need assistance during installation, please contact your local dealer or the Technical Services Department, Hearth & Home Technologies Inc., 1-800-927-6841 or 1-888-427-3973.
WARNING!
This fireplace and its components are designed to be installed and operated as a system. Any alteration to or substitution for items in this system, unless allowed by these installation instructions, will void the Underwrit­ers Laboratories listing and may void the product warranty. It may also create a hazardous installation. Read through these instructions thoroughly before starting your installation and follow them carefully throughout your project.
B. DESCRIPTION OF THE FIREPLACE SYSTEM
1. The Hearth Technologies fireplace system consists of the following:
a. Fireplace/Integral Grate b. Refractory c. Chimney Termination Cap d. Chimney System e. Hearth Extension
2. Optional Components Include:
a. Glass Doors b. Chimney Air Kit c. Outside Combustion Air System d. Fan Kit (BC36C only)
Note: Illustrations used throughout these instructions
reflect “typical installations” and are for design purposes only. Actual installation may vary slightly due to indi­vidual design preferences. However, minimum and maxi­mum clearances must be maintained at all times.
The illustrations and diagrams used throughout these installation instructions are not drawn to scale.
Figure 1 - Typical Fireplace System
4 34962 Rev G 08/04
BC36C/BC36R INSTALLATION INSTRUCTIONS
C. SYSTEM COMPONENTS
1. Fireplace Components
Catalog # Description:
BC36C Circulating Fireplace with Integral Grate and Hearth Protection Strips
BC36R Radiant Fireplace with Integral Grate and Hearth Protection Strips
DM1036 Glass Doors - Bi-fold, Clear-View - Black
DM1036B Glass Doors - Bi-fold, Clear-View - Polished Brass
DM1036S Glass Doors - Bi-fold, Clear-View - Stainless Steel
FK22 Fan Kit with Electrical Junction Box (BC36C only)
BC10 Fan Motor Rheostat Control (BC36C only)
JK9 Electrical Junction Box (BC36C only)
HX3 Hearth Extension
GR16 Integral Grate (included with Fireplace)
AK22 Outside Air Kit
*The JK9 junction box must be installed at the time of initial fireplace installation or considerable reconstruction may be required. Refer to the installation instructions included with the JK9 and FK22 for proper installation.
GR16 - Grate
FK22 - Fan Kit with
Electrical Junction Box (for
BC36C only)
Bi-Fold Glass Doors
HX3 - Hearth Extension
BC10
(for BC36C only)
08/04 34962 Rev G 5
BC36C/BC36R INSTALLATION INSTRUCTIONS
Fireplace Dimensions
(BC36C shown, same as BC36R)
AK22 - Outside Air Kit
6 34962 Rev G 08/04
BC36C/BC36R INSTALLATION INSTRUCTIONS
2. Chimney Components
The following pictures show only those chimney components which may be safely used with this fireplace.
Catalog # Description:
CAK4A Chimney Air Kit
ID 4 Insulat e d Duc t/Outsi d e A i r
UD4 Uninsulated Duct/Outside Air
SL306 Chimney Section - 6 in. long
SL312 Chimney Section - 12 in. long
SL318 Chimney Section - 18 in. long
SL324 Chimney Section - 24 in. long
SL336 Chimney Section - 36 in. long
SL348 Chimney Section - 48 in. long
SL3 Chimney Stabilizer
SL315 Chimney Offset/Return - 15-degree
SL330 Chimney Offset/Return - 30-degree
FS338
FS339 Firestop - 15-degree
FS340 Firestop - 30-degree
AS8 SL300 Straight Attic Insulation Shield, 24 in.
JB877 Chimney Joint Band
CB876 Chimney Bracket
RF370 Roof Flashing - Flat to 6/12 Pitch
RF371 Roof Flashing - 6/12 to 12/12 Pitch
TR344 Round Termination Cap
TR342 Round Telescoping Termination Cap
ST375 Square Termination Cap
TS345 Square Termination Cap
TS345P Square Termination Cap - Painted
TCT375 Terra Cotta Termination Cap
CT35 Chase Top
LDS33 Decorative Shroud - 3 ft x 3 ft
LDS46 Decorative Shroud - 4 ft x 6 ft
Firestop - Straight
08/04 34962 Rev G 7
Chimney Sections
Catalog # A B
SL306 6 in. 4-3/4 in.
SL312 12 in. 10-3/4 in.
SL318 18 in. 16-3/4 in.
SL324 24 in. 22-3/4 in.
SL336 36 in. 34-3/4 in.
SL348 48 in. 46-3/4 in.
A = Actual length B = Effective length (length of
chimney part after it has been snapped to another)
BC36C/BC36R INSTALLATION INSTRUCTIONS
SL3 - Chimney Stabilizer Offset/Return
Firestop Spacer
RF370 - Roof Flashing
Flat to 6/12 Pitch
RF371 - Roof Flashing
6/12 to 12/12 Pitch
Catalog # A B
FS338 0-deg. 14-1/2 in.
FS339 15-deg. 18-3/8 in.
FS340 30-deg. 23 in.
CB876
Chimney Bracket
8 34962 Rev G 08/04
JB877
Joint Band
AS8
Straight Attic
Insulation Shield
BC36C/BC36R INSTALLATION INSTRUCTIONS
Square Termina-
TCT375
Terra Cotta
Termination Cap
TS345/TS345P
tion Cap
Square Termination Cap
ST375
TR344
Round Termina-
tion Cap
TR342
Round Telescoping
Termination Cap
CT35
Chase Top
LDS33 (3 ft x 3 ft) LDS46 (4 ft x 6 ft)
Decorative Shroud
08/04 34962 Rev G 9
BC36C/BC36R INSTALLATION INSTRUCTIONS
D. PRE-INSTALLATION PREPARATION
1. Fireplace Locations and Space Requirements
Several options are available to you when choosing a location for your fireplace. This fireplace may be used as a room divider, installed along a wall, across a corner or used in an exterior chase. See Figure 2.
Locating the fireplace in a basement, near frequently opened doors, central heat outlets or returns, or other locations of considerable air movement can affect the performance and cause intermittent smoke spillage from the front of the fireplace. Consideration should be given to these factors before deciding on a location.
CLEARANCES!
A minimum 1 in. air clear­ance must be maintained at the back and sides of the fire­place assembly except at the nailing flange where the clearance is 1/2 in.
Chimney sections at any level require a 2in. minimum air space clearance between the framing and chimney section.
Figure 2 - Fireplace Locations
Figures 3 and 4 show two typical installations assuming an outside air kit is being used. Therefore, an allowance must be made for 90-deg bends. Less space is required when ducting goes directly outside without forming elbows.
These are
rough
framing
dimensions
only.
Installation Along a Wall or an Exterior Chase
Figure 3
Figure 4
Corner Installation
WARNING!
Do not draw outside air from garage spaces. Exhaust products of gasoline engines are hazardous. Do not install outside air ducts such that the air may be drawn from attic spaces, basements or above the
roofing where other heating appliances or fans and chimneys exhaust or utilize air. These precautions will reduce the possibility of fireplace smoking or air flow reversal.
WARNING!
To prevent contact with sagging or loose insulation, the fireplace must not be installed against vapor barriers or exposed insulation. Localized overheating could occur and a fire could result.
10 34962 Rev G 08/04
Loading...