RITIES HAVING JURISDICTION (BUILDING DEPARTMENT or FIRE
OFFICIALS) ABOUT PERMITS REQUIRED, RESTRICTIONS AND INSTALLATION INSPECTION
Non-Catalytic Wood Stove (8040)
OWNER'S MANUAL
INSTALLATION AND OPERATING INSTRUCTIONS
PLEASE READ THIS ENTIRE OWNER’S MANUAL BEFORE YOU INSTALL AND USE
YOUR NEW Tribute WOOD STOVE. To reduce the risk of fire, follow the installation
instructions. Failure to follow these instructions may result in property damage, bodily injury, or
even death.
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE!
CONTACT LOCAL AUTHO
Tribute Model# 8040
04-28-04
TABLE OF CONTENTS
INTRODUCING YOUR TRIBUTE WOOD STOVE...........................................................................2
HearthStone Quality Home Heating Products Inc ® Tribute Model 8040
1
Introducing Your
Tribute Wood Stove
Congratulations! You have just invested in a most unique
wood burning stove – the Tribute Wood Burning Stove
from HearthStone Quality Home Heating Products Inc®.
The Tribute Model –8040 is a clean burning EPA
certified, non-catalytic wood burning stove. At 1.1 cubic
feet capacity and 2.97 grams per hour particulate you can
be proud to join the Hear thStone family with our Premier
Soap Stone Wood Burning Stove. The front door, along
with the generous depth allow for loading of wood up to
16 inches long!
Your purchase insures years of clean, comfortable heat
with minimal maintenance. You will receive the benefits
of the most advanced technology in wood burning without
the cost and maintenance requirements of a catalytic
stove. The Tribute blends modern technology with the
unique beauty and heating qualities of soapstone, long
known for its even heat production and long heatretaining ability. We trust that you will appreciate the
quality of our handcrafted product.
Please read this manual in its entirety. Its purpose is to
familiarize you with your stove's safe installation, proper
break-in, operation and maintenance. It contains
information that will be useful to you now, and in years to
come, so keep it handy and refer to it as needed.
Use these instructions as well as national, state, and local
building codes to install your stove. Be sure to maintain
the designated stovepipe and stove clearances to walls,
ceilings, hearth, and other combustible surfaces. This will
help reduce the risk of fire. Failure to follow these
instructions can result in property damage, bodily injury,
and even death.
Locate your stove in a safe, convenient, open area; away
from traffic flow, doors, and hallways; and near a
chimney and chimney connector. Review the proper
clearance measurements from combustible surfaces. You
can safely reduce required clearances in most cases by
using the, optional, rear heat shield, and also with a
special connector pipe and special wall coverings as
specified by this manual, the NFPA 211 codes, and your
local authorities having jurisdiction.
Keep furniture, drapes, curtains, wood, paper, and other
combustibles far away from the stove. Never install the
stove in a location where gasoline, kerosene, charcoal
lighter fluid or other flammable liquids are used or stored.
HearthStone Quality Home Heating Products Inc ® Tribute Model 8040
Locate the stove centrally in your living area to allow the
heat to travel naturally to distant rooms. We recommend
that you do not locate your stove in an uninsulated
basement. The amount of radiant energy required to heat
concrete basement walls is so great that most of the usable
heat is absorbed by them and lost .
SAFETY NOTICE:
A HOUSE FIRE MAY RESULT IF THIS
STOVE IS NOT INSTALLED PROPERLY.
FOR YOUR SAFETY, CAREFULLY
FOLLOW THE INSTALLATION
DIRECTIONS. CONTACT LOCAL
BUILDING OR FIRE OFFICIALS ABOUT
RESTRICTIONS AND INSTALLATION
INSPECTION IN YOUR AREA.
The performance of your stove depends on many
variables. Since all installations are unique, the general
information and operating procedures presented here can
only serve as useful guidelines rather than hard and fast
rules. Should you have any questions, do not hesitate to
contact your dealer for additional information.
Validate your warranty - return your warranty registration
card to HearthStone within 30 days of purchase. Once
your warranty has been validated by returning your
warranty card, contact your dealer for any necessary
warranty service.
When you install your Tribute wood stove, it is
im perative that you adhere to all local codes, which can
be obtained from either of the following two National
sources:
American National Standards Institute, Inc. (ANSI)
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc. (NFPA)
Battery March Park
Quincy, MA 02269
If you are installing your Tribute in a mobile home,
follow the guidelines described in the Manufactured
Home Construction and Safety Standard, Title 24 CFR,
Part 3280 (United States).
SAFETY INFORMATION
Read and understand this Owner's Manual
thoroughly before installing and using this stove.
Make sure to install your stove:
q According to the manufacturer's recommendations.
q In accordance with all applicable codes.
q With the proper sized chimney.
When using your st ove:
q Warn children and others unfamiliar with woodstoves
of the danger of touching hot, radiating surfaces of
your stove. For your additional safety, obtain hearth
and stove guards through your local dealer.
q Follow recommended break -in procedure as outlined
in this manual.
q Burn natural wood only. Higher efficiencies and
lower emissions result when burning air-dried,
seasoned wood, as compared to green or freshly cut
wood.
q Use caution when loading firewood into a hot stove.
q Keep the door closed at all times except when
loading wood.
q Inspect the stovepipe, chimney connector and
chimney, as recommended.
HearthStone Quality Home Heating Products Inc ® Tribute Model 8040
Follow these safety precautions:
q Never modify this stove in any way, especially the
primary air control system.
q Never burn kiln dried wood, painted or treated wood,
solvents, trash, plywood, colored or glossy paper,
artificial logs, cardboard, coal, garbage or driftwood.
Especially, do not burn coal in this stove.
q Never use gasoline type fuel, kerosene, charcoal
lighter fluid, or other liquid fuels or solid fire starters
to start or invigorate the fire. These fuels can
possibly generate carbon monoxide, which can
deplete the supply of oxygen. Keep all such
materials away from the stove.
q Never use a wood grate or other device to elevate the
fire.
q Do Not allow logs to rest against or otherwise come
in contact with the glass when the door is closed.
q Do Not slam the door or use the door to force wood
in to the stove.
q Never over -fire your stove. (See page 18)
q Never put ar ticles of clothing or candles on a hot
stove.
q Do Not connect the stove to a flue that is serving
another appliance.
WARNING: FIREPLACE STOVES EQUIPPED
WITH DOORS SHOULD BE OPERATED ONLY
WITH DOORS FULLY OPEN OR DOORS FULLY
CLOSED. IF DOORS ARE LEFT PARTLY OPEN,
GAS AND FLAME MAY BE DRAWN OUT OF THE
FIREPLACE STOVE OPENING, CREATING
RISKS FROM BOTH FIRE AND SMOKE.
Other safety guidelines
q Keep all combustible items such as furniture, drapes,
clothing, and other items, at least 36" (0.92 m) from
the stove (See page 7)
q Install a smoke detector, preferably in an area away
from your wood stove.
q Keep a fire extinguisher handy. We recommend the
type rated "A B C."
q Dispose of ashes properly. (See page 19)
q Keep children and pets away from the stove; they
could be burned by touching a hot stove.
3
q Clean your chimney system as needed. (See page 19)
PERIODIC CHECKLIST
Perform each of these tasks at the specified intervals.
At the End of Every Week:
• Empty ashes from the firebox sooner if the firebox
begins to fill up.
At the Beginning of Every Other Month:
• A visual inspection of the chimney connector and
chimney for creosote is recommended depending
upon your use of the stove. (Please see page 19)
• Check door seals using the "dollar bill test." - When
the fire is out and the stove is cool, shut the door on a
dollar bill. If the bill pulls out without any resistance,
then your stove’s door isn't sealed properly. To
tighten the seal, change the door gasket. (Refer to
page 20.)
At the End of Every Season:
• Dismantle the chimney connector and clean it
thoroughly. Replace any pieces that show signs of
rust or deterioration.
• Inspect and, if necessary, clean your chimney.
• Thoroughly clean out the inside of the stove.
• Inspect all door gasket material and replace if worn,
frayed, cracked or extremely hard.
EMERGENCY PROCEDURES
If you have a stovepipe or chimney fire, follow these
instructions:
1. If the fire is too threatening, leave the area and call
the fire department immediately! If not, perform the
next three steps.
2. Close the primary air control.
3. Close the stovepipe damper (if present).
4. Keep the stove door closed!
¦ WARNING
DO NOT ATTEMPT TO PUT OUT A STOVEPIPE
OR CHIMNEY FIRE BY THROWING WATER
ONTO THE STOVE, STOVEPIPE, OR
CHIMNEY. THE EXTREMELY HIGH
HearthStone Quality Home Heating Products Inc ® Tribute Model 8040
4
TEMPERATURE ASSOCIATED WITH SUCH
FIRES CAN CAUSE INSTANTANEOUS STEAM
AND SERIOUS BODILY HARM.
Once the chimney fire has expired, leave the primary air
control closed and let the fire in the stove die out
completely. The stove should not be fired again until the
stove, stovepipe, and chimney are all thoroughly
inspected for any sign of damage. You must correct any
damage before using your stove again.
SPECIFICATIONS
Maximum Heat Output. 36,000 BTUs per hour of
cordwood (based on
independent laboratory test
results).
Size Of Heated Area . 1,300 square feet.
Firebox Capacity. 1.2 cubic feet (.031 cubic
meters) or 22 pounds of wood
(The amount and weight of
wood contained per cubic foot
of firebox volume can vary
from 15 to 36 lbs. per cubic
foot depending on type of
wood, moisture content,
packing density and other
factors. As a constant for
comparison and test pur poses,
we are assuming 20 lbs. of
seasoned hardwood per cubic
foot of firebox volume).
Outside Air Kit 90-53400
Blower 90-57210
Screen 90-69400
Soapstone Finish1 Polished Gray Soapstone
Castings Finish Painted Matte; and Porcelain
Enamel (Brown, Sea-foam, Blue-black
and Black)
1
Polished gray soapstone is a natural product and will vary from
stone to stone. Various amounts of gray, charcoal, blue and green
will be evident according to the natural composition of the stone.
HearthStone Quality Home Heating Products Inc ® Tribute Model 8040
5
UNPACKING
HearthStone Stoves packages your Tribute stove with the
greatest care, so that it ships safely. Under certain
circumstances, however, damage can occur during transit
and handling. When you receive your stove, unpack it
carefully, inspecting your stove and all parts for damage.
Also, make sure that all parts are included in the box. If
any parts are damaged or missing, please contact your
dealer immediately.
INSTALLING YOUR STOVE
First, you must decide where your stove will reside. After
choosing an appropriate spot, inspect this location to
make sure that the stove will have enough clearance to
combustible materials that would surround the stove.
These combustibles can include walls, floor, ceiling,
fireplace, and chimney. You must carefully consider the
clearances to all of these combustibles before actually
connecting your stove. When considering these
clearances, also decide the kind of floor the stove will rest
on.
Please use this section to plan how to locate your stove in
your particular location. Consider both the clearances of
the stovepipe and the stove itself to the surrounding
combustibles.
The soapstone walls of the Tribute soapstone stove
produce and even, radiant heat. Locate the stove centrally
in your living area to allow the heat to travel naturally to
distant rooms. It is not recommended that you locate your
stove in an uninsulated basement. The amount of radiant
energy required to heat concrete basement walls is so
great that most of the usable heat is absorbed by them and
lost.
Read this chapter to obtain a sound understanding of how
to properly install your stove.
If you use a close clearance connector pipe, it must be
tested to UL standards and listed. Check the listing of
your pipe for actual clearances. The diagrams in this
manual represent typical installations, but are specific to
the Simpson Dura-Vent DVL brand. Clearances cannot
be reduced without the use of close clearance connector
pipe and/or by protecting the surfaces per NFPA 211
standards.
Setting Up Your Tribute
Wood Stove
Minimum Hearth Pad Clearances
Clearances To NFPA 211 Protected Surfaces
You can reduce the clearances to combustible surfaces by
using any National Fire Protection Agency (NFPA)
approved wall protection system. Please refer to NFPA
211 for specifications and complete details. You can
obtain this information directly from NFPA.
National Fire Protection Agency
Batterymarch Park
Quincy, MA 02269
1-800-344-3555
1-617-770-3000
HEARTH REQUIREMENTS AND FLOOR
PROTECTION
Combustible flooring must be protected with a UL listed
hearth pad, or in the absence of fabricate one with an Rvalue of 0.6 (slate, marble tiles, or other noncombustible
material can be used for this purpose). The floor
protection must extend beyond the bod y of the stove at
the minimum as follows:
• SIDES 3-1/2” (20 cm Canada)
• REAR 0” (20 cm Canada)
• FRONT 16” (45 cm Canada)
When installing the Tribute with a rear exit, the minimum
area to be covered by floor protection is under the
chimney connector and 2” (51 mm) beyond each side.
Note: Dimensions shown in figure above are measured
from the body of the stove unless otherwise stated.
HearthStone Quality Home Heating Products Inc ® Tribute Model 8040
6
Floor protector’s come with various types of
specifications. To convert a floor protector’s specification
to an R-value, do one of the following:
• If the R-value is given, use that value—no
conversion is needed.
• If a k-factor is given with a required thickness
(T) in inches, use this formula: R-value = 1/k x T
• If a C-factor is given, use the formula: R-value =
1/C
To determine the R-value of the proposed alternate floor
protector:
• Use either the k-factor or the C-factor formula
explained above to convert specifications not
expressed as R-values.
• For multiple layers of floor protectors, simply
add the R-values of each layer to deter mine the
overall R-value of the layers.
If the overall R-value of your setup is greater than the
R-value of the specified floor protector, then your setup is
acceptable.
Noncombustible Material Thickness R-value
Gypsum or plaster board1
Wallboard, Wonderboard, or
Durock1
Ceramic board (Fiberfrax or Micor)
Nominal solid clay brick1
Ceramic wall or floor tile1
Mineral wool insulation2
Cement mortar2
Horizontal still air2 *
1
/2″
1
/2″
1
1
/2″
1″
1
/4″
1″
1″
1
/8″
0.45
0.20
1.10
0.20
0.01
3.12
0.20
0.92
Handle Assembly
Locate the handle, bolt, and washers enclosed in the
envelope with the owner’s manual. Place the washers on
the bolt and then push it through the handle so that the
bolt threads extend through the bottom of the handle.
Using a slotted screwdriver, turn the bolt
into the chrome latch on the door, until snug.
Handle Operation
Front Door – when closed, the handle will
be in the 7 o’clock position. To open the
front door, rotate the latch clockwise to
approximately the 10 o’clock position.
Code Compliant Masonry Fireplace
OUTSIDE AIR SUPPLY
(Kit # 90-53400)
10-1/2"
HANDLE CRANK
(ATTACHED TO STOVE)
WOOD HANDLE
WASHER
BOLT
stove performance in a particularly airtight house.
The outside air kit for this stove allows for the direct
connection of the stove's air intake to a minimum 3" (76
mm) diameter duct (supplied by others) which leads to the
outside of the house. When considering placement of the
duct from the outside of the house to the hearth, keep in
mind the need to avoid structural members of the house.
The outside air kit will attach to the back of the stove.
The termination of the duct on the outside wall of the
stove should be located in such a manner so as to preclude
the possibility of obstruction by snow, leaves or other
material and should be screened against animals and
insects. The termination should be screened using
¼” x ¼” mesh rodent screen and be covered with a
rain/wind proof hood (flex pipe, outside termination,
mesh, and hood supplied by others) Contact your dealer
for availability).
or Listed ZC Fireplace
18
An outside air source may
be connected directly to this
stove using an optional
outside air kit. The
advantage of providing
outside air directly to the
stove is that the air used by
the st ove for combustion is
taken from outside of the
residence rather than from
within the room where the
stove is located. With
outside air supplied directly
to the stove, drafts within
the room and air infiltration
within the building are
reduced. Use of the outside
air kit may also improve
Mantle
10" max.
6"
Lental
2" max.
1
According to Intertek Testing Services, Inc.
2
According to ASHRAE Handbook of
9
Fundamentals 1977
HearthStone Quality Home Heating Products Inc ® Tribute Model 8040
7
Stove 2" Maximum out of Fireplace - if stove is
more than 2" out, refer to alcove clearances.
CLEARANCES TO COMBUSTIBLES
Clearances may only be reduced by means approved by the regulatory authority.
It is very important to follow minimum clearances for chimney connectors to combustibles such as walls
and ceilings when installing the stove near non-combustible surfaces.
B
D
A
E
G
C
Tribute Clearances
Clearances (inches) A B C D E
Single wall stove pipe without heat shield 16.5 19 21 24
Parallel
27.5 13 17
K
I
H
Corner
G H
I J K
25.5 28.5 68.25
H
J
Single wall stove pipe with heat shield 16.5 14.5 16.5 19.5 27.5 13 11 19.5 22.5 59.75
Double wall stove pipe with heat shield 16.5 8 10
HearthStone Quality Home Heating Products Inc ® Tribute Model 8040
13
27.5 13 7
8
15.5 18.5
54
Loading...
+ 20 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.