Display messages
T801 T802 T803
5
51
52
53
Elevat
ion
Check
incline
sensor or
motor.
Err 51,Err
52,Err 53
happen
during self
test or
calibration.
Turn off and on the power.
Push Stop + Slow together ,
and you are in setup mode.
Push Stop + Fast together in
setup mode, and you are in
Diagnostic mode.
Using fast, slow key to select L
Er (clear last error) and push
Start to clear the error.
Select tESt (Self test mode)in
disgnostic and push Start to
test the treadmill. Then
elevation goes up to max and
go down to min, please check
the right side LED.
It should be more than 200
when elevation in max, and it
should be less than 50 when
the elevation is min.
Check the error message. Error
51, Error 52, Error 53 or no
message. Check the elevation
motor runs or not, when you
test it ?
Warning : Do not step on the
treadmill, it is very dangerous.
If no error message, Please
send the value that is displayed
of right side LED during self
test to Healthstream R&D
center. You have to do
calibration again, if you want to
use the elevation function.
(Diagnostic mode)
Turn off and on the power.
Push Stop + Slow together, and
you are in setup mode. Push
Stop + Fast together in setup
mode, and you are in
Diagnostic mode.
Using fast, slow key to select
CLEAR (clear last error) and
push Start to clear the error.
Then you are in stop mode.
You have to execute diagnostic
mode again.
Select TEST (Self test mode) in
disgnostic and push Start to
test the treadmill. Then
elevation goes up to max and
go down to min, please check
the center LED.
It should be more than 200
when elevation in max, and it
should be less than 50 when
the elevation is min.
Check the error message. Error
51, Error 52, Error 53 or no
message. Check the elevation
motor runs or not, when you
test it?
Warning : Do not step on the
treadmill, it is very dangerous.
If no error message, Please
send the value that is displayed
of center LED during self test to
Healthstream R&D center. You
have to do calibration again, if
you want to use the elevation
function.(Diagnostic mode)
Turn off and on the power.
Push Stop + Slow together, and
you are in setup mode. Push
Stop + Fast together in setup
mode, and you are in
Diagnostic mode.
Using fast, slow key to select
"LAST ERROR : "(clear last
error) and push Start to clear
the error.
Select "SELF TEST READY"
(Self test mode)in disgnostic
and push Start to test the
treadmill. Then elevation goes
up to max and go down to min,
please check the center LCD
module.
It should be more than 200
when elevation in max, and it
should be less than 50 when
the elevation is min.
Check the error message. Error
51, Error 52, Error 53 or no
message. Check the elevation
motor runs or not, when you
test it?
Warning : Do not step on the
treadmill, it is very dangerous.
If no error message, Please
send the value that is displayed
of center LCD module during
self test to Healthstream R&D
center. You have to do
calibration again, if you want to
use the elevation
function.(Diagnostic mode)