HealthSmart 40-686-000 Instruction Manual

Instruction Manual
Model: 40-686-000
Instructions for Use
Please read these instructions carefully and keep them for future reference.
HealthSm art
TM
Cosmo Mist™ Ultrasonic Cool Mist Humidier
KEY TO SYMBOLS
1) Mist Outlet Nozzle
2) Handle
3) Water Tank
4) Transducer
5) Reservoir
6) Base
7) Tank Cap
8) Power Indicator
9) Mist-adjustment/Power Knob
10) Transducer Cleaning Brush
2
1
7
8
9
10
6
5
3
4
Important Safety Instructions
- For any issues with the equipment, refer to the troubleshooting section of this manual, page 6. After removing all packaging materials, ensure that the humidier has not been damaged during transport.
- Do not leave any packaging materials (plastic bags, cardboard boxes, etc.) within the reach of children.
- Before connecting the equipment, ensure that the rated voltage (100-120 V, 50-60Hz) corresponds to the main voltage supply of the electrical outlet.
- To avoid the risk of re, shock or injury, do not use additional power strip adapters and/or extension cords.
- Do not touch the ultrasonic transducer with your hands or tools while the unit is plugged in.
- Do not operate humidier when there is no water in the tank.
- Do not move, tilt or tip the humidier during use. Doing so may cause water leakage.
- Do not disassemble the base.
- Do not replace the power cord.
- If the supply cord is damaged, it must be replaced by the manufacturer in order to avoid a hazard.
- Always disconnect the equipment from the power outlet when it is left unattended or is not in use.
- The product is not a toy. Keep out of reach of children.
- Before performing any cleaning or maintenance, disconnect the equipment from the power outlet.
- Only place the humidier on at, stable surfaces.
- Store and use equipment away from the heat sources like stoves
- Never touch the equipment with wet or damp hands.
- If the equipment is damaged and/or not working properly, turn the unit o
by disconnecting the plug from the power outlet.
- Do not touch the equipment if it falls into water.
- Dispose of any worn accessories and/or equipment at an appropriate collection point as required by state regulation(s).
- Do not direct the vapor ow toward furniture or electrical appliances.
How to Prepare and Use the Equipment
- Check that the equipment is completely clean, the power knob is in the OFF position
and the power cord is not connected to the power outlet.
- Gently remove the water tank from the base.
- Unscrew the cap and ll the water tank. (Puried or distilled water is best.)
- Screw the cap back on and place the water tank on the base securely.
- Place the mist outlet nozzle on top of the water tank, making sure it is correctly
positioned.
- Connect the equipment to a power outlet.
- Choose the desired mist volume by rotating the mist adjustment knob.
- The power indicator light illuminates green when the unit is ON, the vapor will begin
to release.
- To turn the unit OFF, turn the knob counter-clockwise until the unit clicks at which the
indicator light will also turn o.
- When the indicator light is Red, the humidier will not function because the water
level is too low.
- If the water tank is lifted during humidier use, operation will cease. When the tank is
returned securely to the base, operation will resume.
Note: When the tank is full, it is recommended that you carry the tank with both
hands.
Important Safety Instructions (continued)
CAUTION!
- Before cleaning the equipment, always turn the humidier OFF and disconnect the plug from the power outlet.
- Do not place the humidier directly under running water.
- Do not wet the power cable or air outlet.
- Do not scrape the ultrasonic transducer with metallic or sharp objects.
- Do not leave water in the tank when it is not in use.
- Dry all parts thoroughly before storage.
- Do not use abrasive products, alcohol, solvents or similar products that may cause permanent damage to surfaces.
- Never submerge the equipment in water or any other liquid.
Cleaning and Maintenance
Base cleaning:
- Weekly cleaning is recommended.
- Wipe away any debris in the base and its components with a clean, soft cloth or brush.
Transducer cleaning:
1. Apply a vinegar solution (50/50 mix of white vinegar and water) or detergent (small
amount) to the surface of the transducer and leave it on for two to ve minutes.
2. After 2-5 minutes, wash out solution.
3. Wipe away any debris with a clean, soft cloth or brush (included with unit).
Water tank cleaning:
1. Apply a 1/4 cup of vinegar or a small amount of dish detergent into the water tank.
2. Fill the tank half way with clean water.
3. Tighten the cap securely and shake the tank a few times, then empty contents.
5. Rell with clean water, shake again and empty contents.