CAUTIONS AND WARNINGS
INTENDED USE
This Health o meter® Professional platform scale is intended to be used in a professional medical environment
by trained medical staff. This product was designed to weigh patients who are safely positioned and standing
on the platform. Do not modify the product or use it for anything other than its intended purpose.
To prevent patient/caregiver injury or damage to your scale, please follow the instructions in this
user manual very carefully.
Do not exceed the weight capacity specified for this scale.
For accurate weighing, this scale must be placed on a flat, stable surface.
For accurate weighing, verify before each use the proper operation according to the procedure
described in this manual.
Do not use in the presence of flammable or explosive materials.
If the scale becomes damaged, it should not be operated until properly serviced.
Do not wheel or pull the scale down stairs, doing so may damage internal parts.
Ensure that the AC adapter and scale do not come in contact with liquids, excessive temperature,
or excessive humidity.
Patient/caregiver safety
This scale is designed for static weighing of patients only. No scale should be used for patient
transfer.
To prevent patient injury, the patient must be attended throughout the entire weighing event.
Caregivers should ensure that the patient is stable and provide support as needed when getting
onto and off of the scale.
Patient should wear socks or other form of lightweight foot covering during weighing event.
When operating the scale with the AC adapter:
Operate this scale exclusively with the AC adapter that is provided (ADPT30). Use of an
unspecified adapter will void the warranty, and can pose a serious safety hazard.
Prior to using this scale, inspect the AC adapter cord for cracking / fraying, or for broken / bent
plug prongs.
Prior to using this scale, ensure that the AC adapter is plugged into an outlet with the rated
voltage appropriate for operation.
Ensure that the AC adapter outlet is wired to a circuit breaker or other protected power source.
Unplug the AC adapter, and carefully store both the adapter and adapter cord before moving the
scale.
Operating this scale at voltages and frequencies other than specified can damage the equipment
and will void the warranty.
When operating the scale with batteries:
If the scale’s battery icon indicates that the batteries are low replace the batteries or switch to the
AC adapter as soon as possible.
When replacing / inserting batteries, be sure to use all new batteries.
This equipment has been tested and found to comply with the EMC limits for the Medical Device Directive
93/42/EEC (EN 55011 Class A and EN 60601-1-2). These limits are designed to provide reasonable
protection against harmful interference in a typical medical installation. The equipment generates, uses
and may radiate radio frequency energy and, if not installed and used in accordance with these
instructions, may cause harmful interference to other devices in the vicinity. There is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful interference with
other devices, which can be determined by turning the equipment off and on, the user is encouraged to try
to eliminate the interference by one or more of the following measures:
Reorient or relocate the receiving device.
Increase the separation between the equipment.
Connect the equipment into an outlet on a circuit different from that to which the other device(s) is
connected.
Consult Customer Service or a field service technician for help.
In no event whatsoever shall Pelstar, LLC be liable for damages or injuries whatsoever arising out
of or connected with the assembly, use, or misuse of its products.
P/N UM1100KL_1100KG_REV20181128
3
Capacity and
Resolution
1100KL: 1000 lb x 0.2 lb (454 kg x 0.1 kg)
1100KG: 454 kg x 0.1 kg
Power Requirements
100-240V AC, 50-60Hz to 9V DC Adapter (Type: UE15WCP1 9 VDC @ 500
mA), Item # ADPT30 (included) or 6 D batteries (not included)
Environmental
Operating temperatures: 50°F to 95°F (10°C to 35°C)
Storage temperatures: 30°F to 125°F (0°C to 50°C)
Maximum Humidity: 85% RH
Do not dispose of this device in
the domestic waste stream.
SPECIFICATIONS
General
This scale uses highly sophisticated microprocessor technology. Each precision scale is
designed to provide accurate, reliable and repeatable weight measurements. This scale
uses motion-sensing weighing technology to determine the actual weight of a moving
patient.
The 1100KL displays weight in pounds (lb) or kilograms (kg). Refer to Page 11 to learn
more about configuring the weight measuring unit setting. The 1100KG displays weight
in kilograms only.
The scale can be powered using an AC adapter (ADPT30 included), or by 6 D batteries
(not included).
Scale Specifications
Scale information can be found by pressing and selecting “Scale Info” in the submenu. This
screen provides model number, capacity, calibration weight, the most recent field calibration date,
number of field calibrations and software version.
DEFINITION OF SYMBOLS
The scale surface, along with the height rod, (if provided) are the Type B applied parts.
P/N UM1100KL_1100KG_REV20181128
4
CERTIFICATIONS / CONNECTIVITY / DISPOSAL
Pelstar, LLC has been officially certified as the manufacturer
of Health o meter® Professional medical devices. The Pelstar,
LLC quality assurance system covers the development,
production, sales and service of medical scales and
measuring systems.
Products carrying this symbol meet the requirements of:
Directive governing medical devices 93/42/EEC
E112697
0459
Certification
All Health o meter® Professional scales are manufactured in FDA-registered factories.
Connectivity Information
To enable reliable transmission of weight, height, and Body Mass Index (BMI) data, this
scale is designed to connect to a computer, monitor, or other electronic device via USB
or Pelstar wireless technology. This connectivity helps minimize a source of potential
medical errors caused by incorrectly copying and then recording patient data. For more
information regarding how to connect the scale to other electronic devices, please
contact Health o meter® Professional Scales Technical Support, available during normal
business hours at 1-800-638-3722.
Scale Disposal
This Health o meter® Professional scale must be disposed of properly as electronic
waste. Follow the national, regional or local regulations which apply to you for disposal
of electronic waste or batteries. Do not dispose of this device in the domestic waste
stream.
P/N UM1100KL_1100KG_REV20181128
5
ASSEMBLY INSTRUCTIONS
Brown Box Contents
White Box Contents
Hardware Detail
A B C
D E F
Side Handrail
Side Handrail
Center Handrail
Platform/Base
Before Assembly
Carefully inspect the carton for shipping damage before unpacking. If damage is found, contact
your shipper or a Health o meter® Professional representative immediately at 1-800-815-6615.
Claims must be filed with the shipper as soon as possible after receipt of the package. The
following information details what you will find inside the main carton as you unpack the parts for
assembly.
To prevent scratching any components, carefully remove each assembly from the carton and
unwrap the packing materials. Set the carton aside for storage. To avoid damaging the scale
parts when unpacking, do not use a box cutter, knife, scissors, or any sharp object to open the
protective inner packaging.
Parts List
(2) Side handrails
(1) Center handrail
(1) Scale platform/base
(1) Phillips head screwdriver
(1) Brown box containing:
(1) Box containing the AC adapter
(1) Display Head
(1) User Information
(1) White box containing:
o (4) Feet
o (1) AC adapter holder
o (1) 5mm Allen wrench
o (1) 8mm Allen wrench
o (1) Plastic bracket cover
o Hardware for assembly:
A - M10 1.5 x 40mm bolts, Qty.4
B - M8 1.25 x 20mm bolts, Qty. 4
C - M4 0.7 x 10mm screws, Qty.6 for assembly, 1 spare
D - #8 ½” sheet metal screws, Qty. 2
E - M8 washers, Qty. 4
F – Display support covers, Qty. 2
Tools Required
Phillips head screwdriver (included), Allen wrenches (included)
P/N UM1100KL_1100KG_REV20181128
6
ASSEMBLY INSTRUCTIONS (CONT.)
1. Remove the scale platform/base from
the carton and place on a flat, level, and
dry surface with the Health o meter
Professional logo facing you. Locate the
center handrail and the load cell cable
protruding from the bottom of the right
side. Feed the load cell cable into the
handrail support on the right side of the
scale platform. Feed the cable through
the support and out through the hole
behind the wheel on the underside of
the platform. Ensure that the cable is fed
through the hole towards the top of the
wheel, not through the channel next to
wheel.
2. Grasp the load cell cable protruding from
the bottom of the platform and feed it
through the protective metal shield.
3. Plug the load cell cable into the load cell
port located on the bottom of the
platform.
4. Position the center handrail onto the left
and right handrail supports on the scale
platform. Be sure not to pinch the cable.
Place the four M8 washers (Part E) onto
the four M8 1.25 x 20mm bolts (Part B)
and insert into the mounting holes on the
handrails and into the handrail support.
Lightly tighten using the included 5mm
Allen wrench. Do not over-tighten.
Health o meter® Professional Scales recommends that assembly be performed by
two people.
Warning: Do not drop scale, as this can permanently damage the load cells.
Caution: Do not insert the batteries into the display head until it is mounted onto
the scale.
P/N UM1100KL_1100KG_REV20181128
7
ASSEMBLY INSTRUCTIONS (CONT.)
5. Align the left and right side handrails
with the mounting holes in the center
handrail. Insert the four M10 1.5 x
40mm bolts (Part A) through the side
handrails into the mounting holes in the
center handrail. Lightly tighten using the
8mm Allen wrench.
6. Facing the scale, pull the side handrails
toward you to tip the scale and gently
place it face down on the floor. Thread
the four feet into the underside of the
platform. Each foot should be completely
hand tightened then back the feet out 1½ full turns. This allows for proper load
cell operation.
7. Carefully tilt the scale back to an upright
position on the floor. Warning: Do not
drop scale, as this can permanently
damage the load cells. Adjust the feet
to level the scale. Be certain that the feet
are not completely tightened into the
platform. Pull the excess cable through
the top of the center handrail.
8. Obtain the display head and align the
four holes on the back of the display
head with the four mounting holes on
the silver display support. Using the four
included M4 0.7 x 10mm screws (Part
C), fasten the display head onto the
display support using a Phillips head
screwdriver to tighten the screws.
Ensure that the
spacer spring is on
the bolt of the foot
before inserting into
the platform.