English

1 Technical Details 4.........................................
1.1 General Information 4........................................
1.1.1 Overview 4.................................................
1.1.2 Characteristics 4.............................................
1.1.3 Applications 5...............................................
1.1.4 Quality 6...................................................
1.1.5 Accessories 6...............................................
1.2 General Specifications 7......................................
2 Sensor Installation 8........................................
2.1 List of Materials 8............................................
2.2 Preparing the Structure 8.....................................
2.3 Placing the Sensor 12.........................................
2.4 Concreting 15................................................
3 Sensor Configuration 17.....................................
3.1 Sensor Calibration Sheet 17....................................
3.1.1 General Information 18........................................
3.1.2 Calibration Data 18...........................................
3.1.3 Temperature Computation 18..................................
FS63 A4261-3.2 HBM: public 3
Technical Details

1 Technical Details

1.1 General Information

This installation guide applies to the following products:
Part Number Description
K-FS63-50-11-302 FS63 – Embedded Temperature Sensor • Outdoor • FC/APC
K-FS63-50-13-302 FS63 – Embedded Temperature Sensor • Outdoor • SC/APC
K-FS63-50-10-302 FS63 – Embedded Temperature Sensor • Outdoor • NC
1.1.1 Overview
The FS63 - Embedded Temperature Sensors are Fiber Bragg Grating (FBG) based sensors, designed to be directly cast into concrete wet mix.
1.1.2 Characteristics
: Robustness
Long-term reliability ensured by innovative sensor design, careful selection of materials and IP68 packag ing.
: Completely passive
Inherent immunity to all electromagnetic effects (EMI, RFI, sparks, etc.) and safe operation in hazardous envi ronments.
4 A4261-3.2 HBM: public FS63
Technical Details
: High multiplexing capability
Connection of a large number of sensors to a single opti cal fiber, reducing network and installation complexity.
: Remote sensing
Large distance between sensors and interrogator (sev eral kilometers).
: Compatible with most interrogators
Provided with calibration sheet, allowing easy and accu rate configuration.
: Self-referenced
Based on the measurement of an absolute parameter ­the Bragg wavelength - independent of power fluctua tions.
1.1.3 Applications
HBM FiberSensing temperature sensors can be used in several temperature measuring applications. They are particularly suited for temperature mapping in large struc tures (SHM).
: Industry : Civil Engineering : Energy : R&D
FS63 A4261-3.2 HBM: public 5
Technical Details
1.1.4 Quality
All HBM FiberSensing's processes are strictly controlled from development to production. Each product is sub jected to high standard performance and endurance tests, individually calibrated and checked before ship ping.
HBM FiberSensing, S.A. concentrates all optical sensing activity of HBM and is an ISO 9001:2008 certified com pany.
1.1.5 Accessories
The implementation of complex sensing networks in large structures is made simpler with HBM FiberSensing accessories. These include cables especially designed to resist harsh environments as in civil engineering, not only during construction, but also during the lifetime of the structure (humidity, corrosion, etc.).
For the installation of weldable temperature sensors in severe environments, an optional metallic protection cover is available.
6 A4261-3.2 HBM: public FS63
Loading...