Hayward Pools SP32202EC, SP3210EC, SP3215EC, SP32152EC, SP32102EC User Manual

...
OWNER’S MANUAL
Pipe Size
[mm]
Flow Rate
GPM [L PM]
Suction Pipe
Length *
Pipe Size
[mm]
Flow Rate
GPM [L PM]
Suction Pipe
Length *
Pipe Size
[mm]
Flow Rate
GPM [L PM]
Suction Pipe
Length *
1 [32]
20 [75]
5
1 ½ [50]
45 [170]
7 ½
2 ½ [75]
110 [415]
12 ½
1 ¼ [40]
30 [110]
6 ¼
2 [63]
80 [300]
10
3 [90]
160 [600]
15
M otor Rated Hor sepower
1.13 (0.84)
0.50 (0.37)
208 - 230 / 115
5.3 - 4. 9 / 9.8
14
1.39 (1.04)
0.75 (0.56)
208 - 230 / 115
7.0 - 6. 2 / 12.4
14
1.85 (1.38)
1.00 (0.75)
208 - 230 / 115
8.5 - 7. 4 / 14.8
14 / 12
2.40 (1.79)
1.50 (1.12)
208 - 230 / 115
11.2 - 10.2 / 20.4
14 / 10
2.70 (2.01)
2.00 (1.49)
208 - 230
11.8 - 11.0
14
15
3.60 (2.69)
3.00 (2.24)
208 - 230
16.0 - 14.8
12
20
3.60 (2.69) *
3.00 (2.24) *
208 - 230 / 460 *
9.6 - 9. 4 / 4.7 *
14 *
1.85 / 0.22 (1.38 / 0.16)
1.00 / 0.12 (0.75 / 0.09)
208 - 230
8.6 - 8. 2
14
2.40 / 0.28 (1.79 / 0.21)
1.50 / 0.18 (1.12 / 0.13)
208 - 230
11.4 - 10.4
14
2.70 / 0.33 (2.01 / 0.25)
2.00 / 0.25 (1.49 / 0.19)
208 - 230
12.4 - 11.2
14
0.94 (0.70)
0.75 (0.56)
5.4 / 10.8
14
1.25 (0.93)
1.00 (0.75)
230 / 115
7.0 / 14.0
14
1.65 (1.23)
1.50 (1.12)
230 / 115
7.7 / 15.4
14 / 12
2.20 (1.64)
2.00 (1.49)
230 / 115
10.8 / 21.6
14 / 10
2.60 (1.94)
2.50 (1.86)
230
11.5
14
15
3.45 (2.57)
3.00 (2.24)
230
13.5
14
15
1.85 / 0.22 (1.38 / 0.16)
1.50 / 0.18 (1.12 / 0.13)
208 - 230
8.6 - 8. 2
14
15
2.40 / 0.28 (1.79 / 0.21)
2.00 / 0.25 (1.49 / 0.19)
208 - 230
11.4 - 10.4
14
15
2.70 / 0.33 (2.01 / 0.25)
2.50 / 0.31 (1.86 / 0.23)
208 - 230
12.4 - 11.2
14
15
,
- - -
- -
INSTALLATION, OPERATION, & PARTS
P/N-IS3200-HC-07
®
TriStar Pump Series
The Hayward TriStar Pump is Specifically Engineered for the demanding requirements of today’s in-ground swimming pool/spa that is equipped with large capacity filters, heaters, and pool cleaning equipment. The TriStar is a self-priming pump that incorporates an improved seal and impeller design that will provide many years of efficient, dependable, corrosion-free service. The advanced design provides superior performance while reducing maintenance requirements. NOTE - To prevent potential injury and to avoid unnecessary service calls, read this manual carefully and completely.
IMPORTANT - READ CAREFULLY
NOTE - The TriStar is a high performance, high efficiency
pump. When replacing most existing pumps, you can use a TriStar pump with a lower horsepower rating than the existing pump. Required: 2” Plumbing minimum.
WWW.HAYWARDCANADA.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
SAVE THIS INSTRUCTION MANUAL
HAYWARD POOL PRODUCTS CANADA INC.
2880 Plymouth Drive, Oakville, ON L6H 5R4 TEL: (905) 829-2880
TriStar Pump Series Page 2 of 8
Pipe Size
[mm]
Flow Rate
GPM [L PM]
Suction Pipe
Length *
Pipe Size
[mm]
Flow Rate
GPM [L PM]
Suction Pipe
Length *
Pipe Size
[mm]
Flow Rate
GPM [L PM]
Suction Pipe
Length *
1 [32]
20 [75]
5
1 ½ [50]
45 [170]
7 ½
2 ½ [75]
110 [415]
12 ½
1 ¼ [40]
30 [110]
6 ¼
2 [63]
80 [300]
10
3 [90]
160 [600]
15
M otor Rated Hor sepower
1.13 (0.84)
0.50 (0.37)
208 - 230 / 115
5.3 - 4. 9 / 9.8
14
1.39 (1.04)
0.75 (0.56)
208 - 230 / 115
7.0 - 6. 2 / 12.4
14
1.85 (1.38)
1.00 (0.75)
208 - 230 / 115
8.5 - 7. 4 / 14.8
14 / 12
2.40 (1.79)
1.50 (1.12)
208 - 230 / 115
11.2 - 10.2 / 20.4
14 / 10
2.70 (2.01)
2.00 (1.49)
208 - 230
11.8 - 11.0
14
15
3.60 (2.69)
3.00 (2.24)
208 - 230
16.0 - 14.8
12
20
3.60 (2.69) *
3.00 (2.24) *
208 - 230 / 460 *
9.6 - 9. 4 / 4.7 *
14 *
1.85 / 0.22 (1.38 / 0.16)
1.00 / 0.12 (0.75 / 0.09)
208 - 230
8.6 - 8. 2
14
2.40 / 0.28 (1.79 / 0.21)
1.50 / 0.18 (1.12 / 0.13)
208 - 230
11.4 - 10.4
14
2.70 / 0.33 (2.01 / 0.25)
2.00 / 0.25 (1.49 / 0.19)
208 - 230
12.4 - 11.2
14
0.94 (0.70)
0.75 (0.56)
5.4 / 10.8
14
1.25 (0.93)
1.00 (0.75)
230 / 115
7.0 / 14.0
14
1.65 (1.23)
1.50 (1.12)
230 / 115
7.7 / 15.4
14 / 12
2.20 (1.64)
2.00 (1.49)
230 / 115
10.8 / 21.6
14 / 10
2.60 (1.94)
2.50 (1.86)
230
11.5
14
15
3.45 (2.57)
3.00 (2.24)
230
13.5
14
15
1.85 / 0.22 (1.38 / 0.16)
1.50 / 0.18 (1.12 / 0.13)
208 - 230
8.6 - 8. 2
14
15
2.40 / 0.28 (1.79 / 0.21)
2.00 / 0.25 (1.49 / 0.19)
208 - 230
11.4 - 10.4
14
15
2.70 / 0.33 (2.01 / 0.25)
2.50 / 0.31 (1.86 / 0.23)
208 - 230
12.4 - 11.2
14
15
,
- - -
- -
WARNING -- This product should be installed and serviced only by a qualified professional.
CAUTION -- A Licensed electrician MUST complete, in full, all electrical installations noted in this manual.
Use of non-Hayward replacement parts voids warranty.
ATTENTION INSTALLER - THIS MANUAL CONTAINS IMPORTANT INFORMATION ABOUT THE INSTALLATION,
OPERATION, AND SAFE USE OF THIS PUMP THAT MUST BE FURNISHED TO THE END USER OF THIS PRODUCT.
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS COULD RESULT IN SERIOUS INJURY.
WARNING - Read and follow all instructions in this
owner’s manual and on the equipment. Failure to follow instructions can cause severe injury and/or death.
IMPORTANT SAFETY INSTRUCTIONS
Before installing or servicing this electrical equipment, turn power supply OFF.
Basic safety percautions should always be followed, including the following: Failure to follow instructions may result in injury.
This is the safety-alert symbol. When you see this symbol on your pump or in this manual, look for one of the following signal words and be alert to the potential for personal injury.
DANGER warns about hazards that will cause serious potential injury, death or major property damage and if
ignored presents an imminent hazard.
WARNING warns about hazards that could cause serious personal injury, death or major property damage and if
ignored presents a potential hazard.
CAUTION warns about hazards that will or can cause minor or moderate personal injury and/or property damage
and if ignored presents a potential hazard. It can also make consumers aware of actions that are unpredictable and unsafe.
The NOTICE label indicated special instructions that are important but not related to hazards.
WARNING - To reduce risk of injury, do not permit children to use or climb on this product. Closely supervise
children at all times. Components such as the filtration system, pumps, and heaters must be positioned to prevent children from using them as means of access to the pool.
CAUTION - This pump is intended for use on permanently installed swimming pools and may also be used with
hot tubs and spas if so marked. Do NOT use with storable pools. A permanently installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage. A storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity. Though this product is designed for outdoor use, it is strongly advised to protect the electrical components from the weather. Select a well-drained area, one that will not flood when it rains. It requires free circulation of air for cooling. Do not install in a damp or non-ventilated location. If installed within an outer enclosure or beneath a skirt of a hot tub or spa, adequate ventilation and free circulation of air must be provided to prevent overheating of the motor.
WARNING - Pool and spa components have a finite life. All components should be inspected frequently and
replaced at least every ten years, or if found to be damaged, broken, cracked, missing, or not securely attached.
WWW.HAYWARDCANADA.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
TriStar Pump Series Page 3 of 8
Pipe Size
[mm]
Flow Rate
GPM [L PM]
Suction Pipe
Length *
Pipe Size
[mm]
Flow Rate
GPM [L PM]
Suction Pipe
Length *
Pipe Size
[mm]
Flow Rate
GPM [L PM]
Suction Pipe
Length *
1 [32]
20 [75]
5
1 ½ [50]
45 [170]
7 ½
2 ½ [75]
110 [415]
12 ½
1 ¼ [40]
30 [110]
6 ¼
2 [63]
80 [300]
10
3 [90]
160 [600]
15
M otor Rated Hor sepower
1.13 (0.84)
0.50 (0.37)
208 - 230 / 115
5.3 - 4. 9 / 9.8
14
1.39 (1.04)
0.75 (0.56)
208 - 230 / 115
7.0 - 6. 2 / 12.4
14
1.85 (1.38)
1.00 (0.75)
208 - 230 / 115
8.5 - 7. 4 / 14.8
14 / 12
2.40 (1.79)
1.50 (1.12)
208 - 230 / 115
11.2 - 10.2 / 20.4
14 / 10
2.70 (2.01)
2.00 (1.49)
208 - 230
11.8 - 11.0
14
15
3.60 (2.69)
3.00 (2.24)
208 - 230
16.0 - 14.8
12
20
3.60 (2.69) *
3.00 (2.24) *
208 - 230 / 460 *
9.6 - 9. 4 / 4.7 *
14 *
1.85 / 0.22 (1.38 / 0.16)
1.00 / 0.12 (0.75 / 0.09)
208 - 230
8.6 - 8. 2
14
2.40 / 0.28 (1.79 / 0.21)
1.50 / 0.18 (1.12 / 0.13)
208 - 230
11.4 - 10.4
14
2.70 / 0.33 (2.01 / 0.25)
2.00 / 0.25 (1.49 / 0.19)
208 - 230
12.4 - 11.2
14
0.94 (0.70)
0.75 (0.56)
5.4 / 10.8
14
1.25 (0.93)
1.00 (0.75)
230 / 115
7.0 / 14.0
14
1.65 (1.23)
1.50 (1.12)
230 / 115
7.7 / 15.4
14 / 12
2.20 (1.64)
2.00 (1.49)
230 / 115
10.8 / 21.6
14 / 10
2.60 (1.94)
2.50 (1.86)
230
11.5
14
15
3.45 (2.57)
3.00 (2.24)
230
13.5
14
15
1.85 / 0.22 (1.38 / 0.16)
1.50 / 0.18 (1.12 / 0.13)
208 - 230
8.6 - 8. 2
14
15
2.40 / 0.28 (1.79 / 0.21)
2.00 / 0.25 (1.49 / 0.19)
208 - 230
11.4 - 10.4
14
15
2.70 / 0.33 (2.01 / 0.25)
2.50 / 0.31 (1.86 / 0.23)
208 - 230
12.4 - 11.2
14
15
,
- - -
- -
WARNING - Risk of Electrical Shock. It is required that licensed electricians do all the
electrical wiring. Hazardous voltage. Can shock, burn, or cause death. To reduce the risk of electrical shock, do NOT use an extension cord to connect unit to electric supply. Provide properly located outlet. All electrical wiring MUST be in conformance with applicable local and national codes and regulations. Before working on pump or motor, disconnect motor wiring.
WARNING - To reduce the risk of electrical shock replace damaged cord immediately. Do NOT bury cord. Locate cord to
prevent abuse from lawn mowers, hedge trimmers and other equipment.
WARNING - Connect only to a grounding type receptacle protected by a Ground Fault Circuit Interrupter (GFCI).
Contact a licensed electrician if you cannot verify that the receptacle is protected by a GFCI.
WARNING - Failure to bond pump to pool structure will increase risk of electrocution and could result in injury or death. To
reduce the risk of electrical shock, see installation instructions and consult a professional electrician on how to bond pump. Also, contact a licensed electrician for information on local electrical codes for bonding requirements.
Use a solid copper conductor, size 6 or larger. Run continuous wire from external bonding lug to reinforcing rod or mesh. Connect a No. 6 AWG solid copper bonding wire to the pressure wire connector provided on the motor housing and to all metal parts of swimming pool, spa, or hot tub, and to all the electrical equipment, metal piping (except gas piping), and conduit within 5 ft. (1.5 m) of inside walls of swimming pool, spa, or hot tub. IMPORTANT - Reference Canadian Electrical Codes for all wiring standards including, but not limited to grounding, bonding and other general wiring procedures.
WARNING -
Suction Entrapment Hazard.
Suction in suction outlets and/or suction outlet covers which are damaged, broken, cracked, missing, or unsecured cause sever injury and/or death due to the following entrapment hazards:
Hair Entrapment - Hair can become entangled in suction outlet cover. Limb Entrapment - A limb inserted into an opening of a section outlet sump or suction outlet cover that is
damaged, broken, cracked, missing, or not securely attached can result in a medical bind or swelling of the limb.
Body Suction Entrapment - A differential pressure applied to a large portion of the body or limbs can result in an entrapment. Evisceration/Disembowelment - A negative pressure applied directly to the intestines through an unprotected suction outlet
sump or suction outlet cover which is damaged, broken, cracked, missing, or unsecured can result in evisceration/disembowelment. Mechanical Entrapment - There is potential for jewelry, swimsuits, hair decorations, fingers, toes, or knuckles to be caught in an opening of a suction outlet cover resulting in mechanical entrapment.
- The maximum system flow rate shall not exceed the values shown in the “Pipe Sizing Chart” found at the bottom of page 4 of this manual
- Never use pool or spa if any suction outlet component is damaged, broken, cracked, missing, or not securely attached.
- Replace damaged, broken, cracked, missing, or not securely attached suction outlet components immediately.
- In addition to two or more suction outlets per pump installed in accordance with the latest IAF (formerly NSPI) standards and CPSC guidelines, follow all national, state, and local codes applicable.
- Installation of a vacuum release or vent system, which relieves entrapping suction, is recommended.
WWW.HAYWARDCANADA.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
WARNING
- When outlets are small enough to be blocked by a person, a minimum of two functioning suction outlets per pump must be installed. Suction outlets in the same place (i.e. floor or wall), must be installed a minimum of three feet (3’) [0.91 meter] apart, as measured from near point to near point.
- Dual suction fittings shall be placed in such locations and distanced to avoid “dual blockage” by a user.
- Dual suction fittings shall not be located on seating areas or on the backrest for such seating areas.
-
To Reduce the risk of Entrapment Hazards:
Loading...
+ 5 hidden pages