Hayward Ultra-Pro LX, Ultra-Pro LX SP2290, Ultra-Pro LX SP2290T, Ultra-Pro LX SP-2295, Ultra-Pro LX SP-2295T Installation And Operating Instructions Manual

...
IS-2290-02-HC
HAYWARD Hi-Performance SELF-PRIMING PUMPS
INSTALLATION AND OPERATING INSTRUCTIONS
GENERAL TIPS ON PUMP INSTALLATION
For best pump performance, locate the system below the pool water line and as close to the pool as possible.
If you own an above ground pool please see Note: NSPI­4 Article V, for safe and proper installation of the equipment package. Make sure suction joints are tight.
Suction pipe should be as large or larger than discharge pipe.
Damp, non-ventilated locations should be avoided. Motors require free circulation of air to aid in cooling.
Insure that the electrical supply available agrees with the motor's voltage, phase and cycle, and that wire size is adequate for the HP/KW rating and distance from the power source. Motor must always be properly grounded. If cord connected, use only a properly grounded outlet. Electrical circuits should be protected by proper size ground fault circuit interrupter (GFCI). All electrical wiring should be performed by qualified personnel and must conform to local codes and regulations.
STARTING AND PRIMING INSTRUCTIONS
Fill strainer/housing completely with water. Never operate the pump without water. Water acts as a coolant and lubricant for the mechanical shaft seal.
Open all suction and discharge lines and valves, as well as air bleed (if available) on filter. (The air that is to be displaced from the suction line must have some place to go).
Turn on power and allow a reasonable time for priming. Priming time depends on suction lift and length of suction piping. If pump will not start, or will not prime, see TROUBLE SHOOTING GUIDE on back page.
Note: NSPI-4 Article V, standard for above ground and on ground pools, advises that components such as the filtration system, pumps and heater be positioned so as to prevent their being used as a means of access to the pool by young children.
Your Hayward Ultra-Pro LX pump has been quality-built and engineered to give you many years of efficient, dependable service. The non-conductive, corrosion-proof motor housing provides protection from the elements and insulates the electrical motor parts from outside contact.
The advanced design reduces operation and maintenance to simple, common-sense procedures.
MAINTENANCE
1. Clean strainer basket regularly. Do not strike basket to clean. Inspect strainer cover gasket regularly and replace as necessary.
2. Hayward pumps have self-lubricating motor bearings and shaft seals. No lubrication is necessary.
3. Keep motor housing clean. Insure air vents are free from obstructions, debris, etc.
4. Occasionally, shaft seals must be replaced, due to wear or damage. See instructions
STORAGE/WINTERIZING
Pump and motor must be protected from freezing. Shut off all electric power. Disconnect cord/electrical connections and plumbing connections. Drain thoroughly and clean out any debris. Store pump and motor in a dry, well ventilated room.
HAYWARD POOL PRODUCTS CANADA, INC.
2880 PLYMOUTH DRIVE, OAKVILLE, ONTARIO L6H 5R4 • (905) 829-2880
® Hayward Pool Products Canada, Inc. – Licensee
PART NUMBER
Ref. DESCRIPTION No. MODEL MODEL
No. Req'd SP2290 (T) SP-2295 (T) (ET)
1 Strainer Cover 1 SP1500D2A SP1500D2A 2 Strainer Cover w/O-ring 1 SP1500P SP1500P 3 Basket 1 SP1500LX SP1500LX 4 Strainer Housing 1 SP1500CP SP1500CP 5 Drain Plug (optional) SP1700FG SP1700FG 6 Drain Plug w/Gasket 1 SP1700FG SP1700FG 7 O-ring 1 SP1500W SP1500W 8 Bolt, No.10-24 Hex. Head 8 SP1500N2 SP1500N2
9 Housing Cover 1 SP1580BP SP1580BP 10 Housing O-ring 1 SP1580Z1 SP1580Z1 11 Impeller 1 SP1500E SP1500F 12 Seal Assembly 1 SP1500KA SP1500KA 13 Pump Housing 1 SP1580AAP SP1580AAP 14 Nut, No. 10-24 Hex. 8 SP1500Y2 SP1500Y2 15 Shaft Sleeve 1 SP1500Q2 SP1500Q2 16 Motor 1 SP1509ZIUF SP1514ZIUF 17 Shroud 1 SP2090B SP2090B 18 Motor Housing 1 SP2090A SP2090A
19a Timer End Cover (Mechanical) (T) 1 SP1500TI SP1500TI 19b Timer End Cover (Electronic) (ET) Optional SP2090CET
20 Motor-To-Housing Bolt 4 To order, specify manufacturer, HP and Model No. 21 Elevated Mounting Base Optional SP2601C SP2601C 22 Motor End Cover Optional SP2090C SP2090C 23 Switch Assembly Optional EC1325 EC1325 24 Power Cord 1 SP1550WA7C SP1550WA7C