Hayward SwimPro SWP120551, SwimPro SWP121051, SwimPro SWP121551, SwimPro SWP120751 Owner's Manual

CENTRIFUGAL PUMPS
SwimPro®
OWNERS MANUAL
SAVE THIS OWNERS MANUAL
WARNING: Electrical Hazard. Failure to follow
instructions can result in serious injury or death.
FOR USE WITH SWIMMING POOLS
WARNING Disconnect the pump from the main power supply completely before servicing the pump or filter.
WARNING All electrical connections must be done by a qualified electrician according to local electrical regulations
WARNING This Product should be installed and serviced only by a qualified professional.
WARNING Read and follow all instructions in this owners manual and on the equipment. Failure to follow
instructions can cause serious injury or death. This document should be given to the owner of the swimming pool and must be kept by the owner in a safe place.
WARNING Be certain the pump is only plugged into a 230 V ± 10% outlet that is supplied through a Residual Current
Device (RCD or Safety Switch) with a residual operating current not exceeding 30mA or supplied by an isolating transformer.
WARNING Use a motor bonding lug to connect motor with other bonded parts using the appropriate size conductor
as required by electrical codes.
WARNING If the supply cord is damaged it must be replaced by the manufacturer, service agent, or similarly qualified
persons in order to avoid a hazard.
WARNING Do not operate the swimming pool pump if the power cord or the housing of the motor connection box is
damaged. This can cause an electric shock. A damaged power cord or motor connection box must be replaced by a service agent or a similarly qualified person immediately in order to avoid a hazard.
WARNING The appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
WARNING
objects away from openings and moving parts.
WARNING Cleaning and user maintenance shall not be made by children without supervision.
and AS/NZS 3000 Wiring Rules .
WARNING The pump is intended for continuous operation at Maximum Water temperature 35°C.
WARNING Use Only Genuine Hayward Replacement Parts.
WARNING This pump is equipped with Automatic Thermal Overload Protection. The motor will automatically shut-
off under normal conditions, before heat damage build-up, due to improper operating condition, can occur. The motor will automatically restart when a safe heat level is reached.
WARNING This pool motor is NOT equipped with a Safety Vacuum Release System (SVRS). SVRS helps prevent
drowning due to body entrapment on underwater drains. In some pool configuration, if a persons body covers the drain, the person can be trapped by suction. Depending on your pool configuration, a SVRS may be required to meet local requirements.
Zone 1 or 2 ok
ZONE 0
GENERAL
Install the pump at a convenient distance from the edge of the pool to minimize the distance between the suction point and the pump so as to avoid pointless and excessive load losses in the hydraulic circuit. This pump can be mount in swimming pool zone 1 or further away as per the conditions of AS/NZS 3000 Wiring Rules.
Install the pump in a ventilated, dry and well drained area that will not flood when it rains. The motor requires air to flow freely around it to provide natural ventilation for cooling. If installed within an outer enclose or beneath the skirt of a hot tub or spa, adequate ventilation and free circulation of air must be provided to prevent overheating of the motor.
The pump has to be installed, so that the plug and the wall socket outlet is easily visible and accessible.
The pump must be permanently mounted to a concrete base using lag screws suitable for concrete where pilot holes have
been drilled. Locking washers must be supplied to prevent loosening of the mounting lag screws over time. If the pump is
to be mounted to a wooden deck then lag screws suitable for wood must be used - with lock washers to prevent loosening over time.
The acoustic level of the Hayward pumps is lower than 70 dB (A).
ELECTRICAL CONNECTION
Make sure that the power supply voltage required by the motor corresponds to that of the distribution network and that the power supply cables matches the power and current of the pump as in accordance with AS/NZS 3000 Wiring Rules. Any changes to or installation of power outlets must be done by a qualified electrical contractor. The supply power is to be supplied by an isolating transformer or supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30 mA.
The single phase motors fitted to our pumps are provided with thermal protection. This protection operates on an overload or in the event of abnormal heating of the motor coil and is reset automatically when the winding temperature drops which allows the pump to automatically restart without warning.