Hayward SwimClear™, SwimClear C2030, SwimClear C3030, SwimClear C4030, SwimClear C5030 Owner's Manual

...
ISC2031 REV A
SwimClear
by
Owner’s Manual
Models C2030 C3030 C4030 C5030 C7030
FT2 M2 GPM LPM
C2030 225 20.9 84 318
C3030 325 30.2 122 462
C4030 425 39.5 150 568
C5030 525 48.8 150 568
C7030 680 63.2 150 568
MAXIMUM WORKING PRESSURE FOR ALL MODELS 50 PSI (3.45 BAR)
ATTENTION INSTALLER: THIS MANUAL CONTAINS IMPORTANT INFORMATION ON THE OPERATION, AND
THIS MANUAL IS INTENDED FOR THE END USER OF THIS PRODUCT
TOP MANIFOLD CARTRIDGE FILTERS
DESIGN FLOW RATE
Residential Commercial
SAFE USE OF THIS EQUIPMENT.
Hayward Pool Products
620 Division Street, Elizabeth, NJ 07207
Phone: (908) 351.5400 www.haywardnet.com
This is the safety-alert symbol. When you see this symbol on your equipment or in this manual, look for one of
the following signal words and be alert to the potential for personal injury or death.
WARNING Warns about hazards that could cause serious personal injury or, death, and or major property
damage and if ignored presents a potential hazard.
CAUTION Warns about hazards that will or can cause minor or moderate personal injury and/or property damage and if ignored presents a potential hazard. It can also make consumers aware of actions that are unpredictable and unsafe.
The NOTICE label indicates special instructions that are important but not related to hazards.
READ, UNDERSTAND, AND FOLLOW ALL SAFETY AND OPERATION INSTRUCTIONS.
FAILURE TO FOLLOW SAFETY AND OPERATION INSTRUCTIONS CAN RESULT IN SEVERE PERSONAL INJURY OR DEATH.
CAUTION To reduce risk of injury, do not permit children to use or climb on this product. Closely
supervise children at all times. The ANSI/NSPI-4 Standard (above-ground and on-ground pools) advises that components such as the filtration system, pumps, and heaters be positioned to prevent their being used as a means of access to the pool by young children
.
WARNING COMPONENT SEPARATION HAZARD
Pool and spa water circulation systems operate under hazardous pressure during start up, normal operation, and possibly after pump shut off. Pressure in system can cause explosive component separation of the upper filter body if safety and operation instructions are not followed. Severe personal injury or death can result.
This product should be installed and serviced only by a qualified pool professional.
TO AVOID COMPONENT SEPARATION
Follow all safety and operation instructions.
Do not operate water circulation system if a system component is assembled improperly, damaged,
missing, or not a genuine Hayward component.
Before performing maintenance on the water circulation system, verify all system and pump controls
are in OFF position and filter manual air relief valve is in the OPEN position.
Use ONLY Hayward clamp system components: DEX2421JKIT clamp assembly, DEX2421J2 nut/bolt
assembly, and a DEX2422Z2 metal reinforced seal. Non-Hayward components may fail in use and cause explosive separation.
Never rely on hand tightening the clamp nut to the clamp bolt. Using a ¾” socket on a torque wrench,
torque clamp nut and clamp bolt to 150 inch-lbs.
Before starting system pump, insure filter manual air relief valve body is in LOCK position in filter
upper body.
Before starting the system pump, verify that all system valves are set in a position to allow water from
the filter to return back to the pool.
Before starting the system pump, the manual air relief valve must be in the OPEN position.
When starting pump, do not stand over or near filter.
If water leakage appears in the area of the filter tank clamp, immediately turn off all system circulation
pumps and electrical power. Do not return to the filter until all water flow has stopped. Reassemble the clamp system per the instructions in this owner’s manual to stop the leak.
Return to filter to close manual air relief valve only when a steady stream of water (Not air or air and
water mix) is discharged from the manual air relief valve.
Do not change filter control valve position while system pump is running.
WARNING EXCESS PRESSURE HAZARD
Pressure testing of the pump and filter system in excess of the 50 PSI can cause explosive separation of the components. Component separation can result in severe personal injury or death.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Page 2 of 12 SWIMCLEAR CARTRIDGE FILTER ISC2031 REV A
WARNING ELECTROCUTION HAZARD
High Voltage electricity is present in the pool and spa equipment. High voltage electricity can
cause shock and electrocution. Shock and electrocution can result in severe personal injury or death.
All electrical wiring MUST be in conformance with applicable local codes, regulations and the
National Electrical Code (NEC).
Before performing any service or maintenance on electrical equipment turn off all electrical power.
Contact a licensed electrician or building inspector for information on local electrical codes for
bonding requirements.
Verify water discharge from the filter manual air relief valve is directed away from electrical devices.
Do not locate pump controls over or near filter.
WARNING – SUCTION ENTRAPMENT HAZARD.
Suction in suction outlets and/or suction outlet covers that are, damaged, broken, cracked, missing, or unsecured can cause severe injury and/or death due to the following entrapment hazards:
Hair Entrapment- Hair can become entangled in suction outlet cover. Limb Entrapment- A limb inserted into an opening of a suction outlet sump or suction outlet cover that is damaged, broken, cracked, missing, or not securely attached can result in a mechanical bind or swelling of the limb. Body Suction Entrapment- A negative pressure applied to a large portion of the body or limbs can result in an entrapment. Evisceration/ Disembowelment Entrapment- A negative pressure applied directly to the intestines through an unprotected suction outlet sump or suction outlet cover that is, damaged, broken, cracked, missing, or unsecured can result in evisceration/ disembowelment entrapment. Mechanical Entrapment- There is potential for jewelry, swimsuit, hair decorations, finger, toe or knuckle to be caught in an opening of a suction outlet cover resulting in mechanical entrapment.
TO REDUCE THE RISK OF ENTRAPMENT HAZARDS:
A minimum of two functioning suction outlets per pump must be installed. Suction outlets in the
same plane (i.e. floor or wall), must be installed a minimum of three feet (3’) [1 meter] apart, as measured from near point to near point.
Dual suction outlets shall be placed in such locations and distances to avoid “dual blockage” by a
user.
Dual suction outlets shall not be located on seating areas or on the backrest for such seating areas.
The pool or spa circulation system shall be designed to comply with ANSI/APSP-7 2006.
Suction outlet covers shall conform to ANSI/ASME A112.19.8
Never use Pool or Spa if any suction outlet component (cover/grate) is damaged, broken, cracked,
missing, or not securely attached.
Immediately replace damaged, broken, cracked, missing, or not securely attached suction outlet
components.
The CPSP as well as the ICC
specifies the installation of a safety vacuum release system conforming to ASME A112.19.17, or an approved gravity drain system.
Failure to remove pressure test plugs and/or plugs used in winterization of the pool/spa from the
suction outlets can result in an increased potential for suction entrapment.
Failure to keep suction outlet components clear of debris, such as leaves, dirt, hair, paper and other
material can result in an increased potential for suction entrapment.
International Residential Code
Part IX, Appendix G, Section AG106
Suction outlet covers and grates have a finite life. They should be inspected frequently and
replaced within specified life.
SAVE THESE INSTRUCTIONS
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Page 3 of 12 SWIMCLEAR CARTRIDGE FILTER ISC2031 REV A
GENERAL INFORMATION
Your Hayward SwimClearTM cartridge filter combines superior water filtration with ease of operation and totally corrosion-resistant construction. With filtration ratings to 9000 gallons (34,000 liters) per hour, they are designed for continuous or intermittent operation, for installation above or below the pool water line, for fresh or salt water swimming pools or spas. SwimClear™ filters utilize multiple reusable, reinforced polyester filter cartridge elements to provide a high degree of water clarity and long filter cycles with minimum care.
C2030 32.5 83 18 46 15 38 C3030 34.5 88 18 46 16 41 C4030 40.5 103 18 46 18 46 C5030 46.5 118 18 46 22 56 C7030 52.5 133 18 46 28 71
A
IN CM IN CM IN CM
REQUIRED CLEARANCE
“B” SIDE “C” ABOVE
INSTALLATION
WARNING
B
6. Connect the pump discharge (pump OUTLET) to the top port of the filter (filter INLET).
7. Connect the bottom filter port (filter OUTLET) to the pool return plumbing lines.
8. Do not locate pump controls over or near filter.
9. Verify water discharge from the manual air relief valve(MAR) is directed away from electrical devices.
This product should be installed and
serviced only by a qualified pool professional.
1. The filter system should be
installed on a other rigid base. Select a well drained and vented area, one that does not flood when it rains. Position the filter so that the piping connections, and winter drain are convenient and accessible for operation, service, maintenance and winterizing.
2. Position filter body such that all
operation and safety labels are visible.
3. Position filter so the filter will drain
by gravity.
4. If practical, place pump and filter in
the shade to shield it from continuous, direct heat from the sun.
5. Connect the pool suction plumbing
between the skimmer, pool suction outlet (from the pool) and the pump.
level concrete slab or
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS