Hayward SwimClear, SWIMCLEAR C2025, SWIMCLEAR C3025, SWIMCLEAR C4025, SWIMCLEAR C5025 Owner's Manual

...
INSTALLATION, OPERATION, & PARTS
ISC2028 Rev C
Models C2025 C3025 C4025 C5025 C7000
SWIMCLEAR™ CARTRIDGE FILTERS
FT2 M C2025 225 20.9 84 318 C3025 325 30.2 122 462 C4025 425 39.5 150 568 C5025 525 48.8 150 568 C7000 680 63.2 150 568
MAXIMUM WORKING PRESSURE FOR ALL MODELS 50 PSI (3.45 BAR)
EFFECTIVE FILTRATION
RATE
2
GPM LPM
DESIGN FLOW RATE
Residential Commercial
ATTENTION INSTALLER: THIS MANUAL CONTAINS IMPORTANT INFORMATION
ON THE OPERATION, AND SAFE USE OF THIS EQUIPMENT.
THIS MANUAL IS INTENDED FOR THE END USER OF THIS PRODUCT
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Page 2 of 12 SWIMCLEAR CARTRIDGE FILTER ISC2028 REV C
This is the safety-alert symbol. When you see this symbol on your equipment or in this manual, look fo r one of the
following signal words and be alert to the potential for personal injury or death.
WARNING Warns about hazards that could cause serious personal injury or, death, and or major property
damage and if ignored presents a potential hazard.
CAUTION Warns about hazards that will or can cause minor or moderate personal injury and/or property damage
and if ignored presents a potential hazard. It can also make consumers aware of actions that are unpr edictable and unsafe. The NOTICE label indicates special instructions that are important but not related to hazards.
READ, UNDERSTAND, AND FOLLOW ALL SAFETY AND OPERATION
INSTRUCTIONS. FAILURE TO FOLLOW SAFETY AND OPERATION INSTRUCTIONS CAN RESULT
IN SEVERE PERSONAL INJURY OR DEATH.
CAUTION To reduce risk of injury, do not permit children to use or climb on this product. Closely
supervise children at all times. The ANSI/NSPI-4 Standard (above-ground and on-ground poo l s) advises that components such as the filtration system, pumps, and heaters be positioned to prevent their being used as a means of access to the pool by young children.
WARNING COMPONENT SEPARATION HAZARD
Pool and spa water circulation systems operate under hazardous pressure during start up, normal operation, and possibly after pump shut off. Pressure in system can cause explosive component separation of the upper filter body if safety and operation instructions are not followed. Severe personal injury or death can result.
This product should be installed and serviced only by a qualified pool professional.
TO AVOID COMPONENT SEPARATION
Follow all safety and operation instructions.
Do not operate water circulation system if a system component is assembled improperly, damaged, missing, or not a
genuine Hayward component.
Before performing maintenance on the water circulation system, verify all system and pump controls are in OFF position and filter manual air relief valve is in the OPEN position.
Use ONLY Hayward clamp system components: DEX2421JKIT clamp assembly, DEX2421J2 nut/bolt assembl y, and a DEX2422Z2 metal reinforced seal. Non-Hayward components may fail in use and cause explosive separatio n.
Never rely on hand tightening the clamp nut to the clamp bolt. Using a ¾” socket on a torque wrench, torque clamp nut and clamp bolt to 150 inch-lbs.
Before starting system pump, insure filter manual air relief valve body is in LOCK position in filter upper body.
Before starting the system pump, verify that all system valves are set in a position to allow water from the filter to return
back to the pool.
Before starting the system pump, the manual air relief valve must be in the OPEN position.
When starting pump, do not stand over or near filter.
If water leakage appears in the area of the filter tank clamp, immediately turn off all system circulation pumps and
electrical power. Do not return to the filter until all water flow has stopped. Reassemble the clamp system per the instructions in this owner’s manual to stop the leak.
Return to filter to close manual air relief valve only when a steady stream of water (Not air or air and water mix) is discharged from the manual air relief valve.
Do not change filter control valve position while system pump is running.
WARNING EXCESS PRESSURE HAZARD
Pressure testing of the pump and filter system in excess of the 50 PSI can cause explosive separation of the components. Component separation can result in severe personal injury or death.
WARNING ELECTROCUTION HAZARD
High Voltage electricity is present in the pool and spa equipment. High voltage electricity can cause shock and electrocution. Shock and electrocution can result in severe personal injury or death.
All electrical wiring MUST be in conformance with applicable local codes, regulations and the National Electrical Code (NEC).
Before performing any service or maintenance on electrical equipment turn off all electrical power.
Contact a licensed electrician or building inspector for information on local electrical c odes for bonding requirements.
Verify water discharge from the filter manual air relief valve is directed away from electrical devices.
Do not locate pump controls over or near filter.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Page 3 of 12 SWIMCLEAR CARTRIDGE FILTER ISC2028 REV C
WARNINGSUCTION ENTRAPMENT HAZARD.
Suction in suction outlets and/or suction outlet covers that are, damaged, broken, cracked, missing, or unsecured can cause severe injury and/or death due to the following entrapment hazards:
Hair Entrapment- Hair can become entangled in suction outlet cover. Limb Entrapment- A limb inserted into an opening of a suction outlet sump or suction outlet
cover that is damaged, broken, cracked, missing, or not securely attached can result in a mechanical bind or swelling of the limb. Body Suction Entrapment- A negative pressure applied to a large portion of the body or limbs can result in an entrapment. Evisceration/ Disembowelment Entrapment- A negative pressure applied directly to the intestines through an unprotected suction outlet sump or suction outlet cover that is, damaged, broken, cracked, missing, or unsecured can result in evisceration/ disembowelment entrapment. Mechanical Entrapment- There is potential for jewelry, swimsuit, hair decorations, finger, toe or knuckle to be caught in an opening of a suction outlet cover resulting in mechanical entrapment.
TO REDUCE THE RISK OF ENTRAPMENT HAZARDS:
A minimum of two functioning suction outlets per pump must be installed. Suction outlets in the same plane (i.e. floor or wall), must be installed a minimum of three feet (3’) [1 meter] apart, as measured from near point to near point.
Dual suction outlets shall be placed in such locations and distances to avoid “dual blockage” by a user.
Dual suction outlets shall not be located on seating areas or on the backrest for such seating areas.
The pool or spa circulation system shall be designed to comply with ANSI/APSP-7 2006.
Suction outlet covers shall conform to ANSI/ASME A112.19.8
Never use Pool or Spa if any suction outlet component (cover/grate) is damaged, broken,
cracked, missing, or not securely attached.
Immediately replace damaged, broken, cracked, missing, or not securely attached suction outlet components.
The CPSP as well as the ICC International Residential Code Part IX, Appendix G, Section
AG106 specifies the installation of a safety vacuum release system conforming to ASME A112.19.17, or an approved gravity drain system.
Failure to remove pressure test plugs and/or plugs used in winterization of the pool/spa
from the suction outlets can result in an increased potential for suction entrapment.
Failure to keep suction outlet components clear of debris, such as leaves, dirt, hair, paper
and other material can result in an increased potential for suction entrapment.
Suction outlet covers and grates have a finite life. They should be inspected frequently
and replaced within specified life.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Page 4 of 12 SWIMCLEAR CARTRIDGE FILTER ISC2028 REV C
GENERAL INFORMATION
Your Hayward SwimClearTM cartridge filter combines superior water filtration with ease of operation and totally corrosion-free construction. With filtration ratings to 9000 gallons (34,000 liters) per hour, they are designed for continuous or intermittent operation, for installation above or below the pool water line, for fresh or salt water swimming pools or spas. SwimClear™ filters utilize multiple reusable, reinforced polyester filter cartridge elements to provide a high degree of water clarity and long filter cycles with minimum care.
C2025 32.5 83 18 46 15 38 C3025 34.5 88 18 46 16 41 C4025 40.5 103 18 46 18 46 C5025 46.5 118 18 46 22 56 C7000 52.5 133 18 46 28 71
A
IN CM IN CM IN CM
REQUIRED CLEARANCE
“B” SIDE “C” ABOVE
INSTALLATION
WARNING
This product should be installed and
serviced only by a qualified pool professional.
B
1. The filter system should be installed on a level concrete slab or other rigid base. Select a well drained and vented area, one that does not flood when it rains. Position the filter so that the piping connections, and winter drain are convenient and accessible for operation, service, maintenance and winterizing.
2. Position filter body such that all operation and safety labels are visible.
3. Position filter so the filter will drain by gravity.
4. If practical, place pump and filter in the shade to shield it from continuous, direct heat from the sun.
5. Connect the pool suction plumbing between the skimmer, pool outlet (from the pool) and the pump.
6. Install the plumbing from the filter to the pool (return to the pool).
7. Do not locate pump controls over or near filter.
8. Verify water discharge from the manual air relief valve(MAR) is directed away from electrical devices.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS