MAXIMUM WORKING PRESSURE FOR ALL MODELS 50 PSI (3.45 BAR)
ATTENTION INSTALLER: THIS MANUAL CONTAINS IMPORTANT INFORMATION ON THE OPERATION, AND
THIS MANUAL IS INTENDED FOR THE END USER OF THIS PRODUCT
TOP MANIFOLD CARTRIDGE FILTERS
DESIGN FLOW RATE
Residential Commercial
SAFE USE OF THIS EQUIPMENT.
Hayward Pool Products
620 Division Street, Elizabeth, NJ 07207
Phone: (908) 351.5400
www.haywardnet.com
This is the safety-alert symbol. When you see this symbol on your equipment or in this manual, look for one of
the following signal words and be alert to the potential for personal injury or death.
WARNING Warns about hazards that could cause serious personal injury or, death, and or major property
damage and if ignored presents a potential hazard.
CAUTION Warns about hazards that will or can cause minor or moderate personal injury and/or property
damage and if ignored presents a potential hazard. It can also make consumers aware of actions that are
unpredictable and unsafe.
The NOTICE label indicates special instructions that are important but not related to hazards.
READ, UNDERSTAND, AND FOLLOW ALL SAFETY AND OPERATION INSTRUCTIONS.
FAILURE TO FOLLOW SAFETY AND OPERATION INSTRUCTIONS CAN RESULT IN SEVERE PERSONAL INJURY
OR DEATH.
CAUTIONTo reduce risk of injury, do not permit children to use or climb on this product. Closely
supervise children at all times. The ANSI/NSPI-4 Standard (above-ground and on-ground pools) advises
that components such as the filtration system, pumps, and heaters be positioned to prevent their being
used as a means of access to the pool by young children
.
WARNINGCOMPONENT SEPARATION HAZARD
Pool and spa water circulation systems operate under hazardous pressure during start up, normal
operation, and possibly after pump shut off. Pressure in system can cause explosive component
separation of the upper filter body if safety and operation instructions are not followed. Severe
personal injury or death can result.
This product should be installed and serviced only by a qualified pool professional.
TO AVOID COMPONENT SEPARATION
• Follow all safety and operation instructions.
• Do not operate water circulation system if a system component is assembled improperly, damaged,
missing, or not a genuine Hayward component.
• Before performing maintenance on the water circulation system, verify all system and pump controls
are in OFF position and filter manual air relief valve is in the OPEN position.
• Use ONLY Hayward clamp system components: DEX2421JKIT clamp assembly, DEX2421J2 nut/bolt
assembly, and a DEX2422Z2 metal reinforced seal.
Non-Hayward components may fail in use and cause explosive separation.
• Never rely on hand tightening the clamp nut to the clamp bolt. Using a ¾” socket on a torque wrench,
torque clamp nut and clamp bolt to 150 inch-lbs.
• Before starting system pump, insure filter manual air relief valve body is in LOCK position in filter
upper body.
• Before starting the system pump, verify that all system valves are set in a position to allow water from
the filter to return back to the pool.
• Before starting the system pump, the manual air relief valve must be in the OPEN position.
• When starting pump, do not stand over or near filter.
• If water leakage appears in the area of the filter tank clamp, immediately turn off all system circulation
pumps and electrical power. Do not return to the filter until all water flow has stopped. Reassemble
the clamp system per the instructions in this owner’s manual to stop the leak.
• Return to filter to close manual air relief valve only when a steady stream of water (Not air or air and
water mix) is discharged from the manual air relief valve.
•Do not change filter control valve position while system pump is running.
WARNINGEXCESS PRESSURE HAZARD
Pressure testing of the pump and filter system in excess of the 50 PSI can cause explosive separation of
the components. Component separation can result in severe personal injury or death.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Page 2 of 12 SWIMCLEAR™ CARTRIDGE FILTER ISC2031 REV A
WARNING ELECTROCUTION HAZARD
High Voltage electricity is present in the pool and spa equipment. High voltage electricity can
cause shock and electrocution. Shock and electrocution can result in severe personal injury or
death.
• All electrical wiring MUST be in conformance with applicable local codes, regulations and the
National Electrical Code (NEC).
• Before performing any service or maintenance on electrical equipment turn off all electrical power.
• Contact a licensed electrician or building inspector for information on local electrical codes for
bonding requirements.
• Verify water discharge from the filter manual air relief valve is directed away from electrical devices.
Do not locate pump controls over or near filter.
WARNING – SUCTION ENTRAPMENT HAZARD.
Suction in suction outlets and/or suction outlet covers that are, damaged, broken, cracked, missing, or
unsecured can cause severe injury and/or death due to the following entrapment hazards:
Hair Entrapment- Hair can become entangled in suction outlet cover.
Limb Entrapment- A limb inserted into an opening of a suction outlet sump or suction outlet cover that
is damaged, broken, cracked, missing, or not securely attached can result in a mechanical bind or
swelling of the limb.
Body Suction Entrapment- A negative pressure applied to a large portion of the body or limbs can
result in an entrapment.
Evisceration/ Disembowelment Entrapment- A negative pressure applied directly to the intestines
through an unprotected suction outlet sump or suction outlet cover that is, damaged, broken, cracked,
missing, or unsecured can result in evisceration/ disembowelment entrapment.
Mechanical Entrapment- There is potential for jewelry, swimsuit, hair decorations, finger, toe or
knuckle to be caught in an opening of a suction outlet cover resulting in mechanical entrapment.
TO REDUCE THE RISK OF ENTRAPMENT HAZARDS:
• A minimum of two functioning suction outlets per pump must be installed. Suction outlets in the
same plane (i.e. floor or wall), must be installed a minimum of three feet (3’)
[1 meter] apart, as measured from near point to near point.
• Dual suction outlets shall be placed in such locations and distances to avoid “dual blockage” by a
user.
• Dual suction outlets shall not be located on seating areas or on the backrest for such seating areas.
• The pool or spa circulation system shall be designed to comply with ANSI/APSP-7 2006.
• Suction outlet covers shall conform to ANSI/ASME A112.19.8
• Never use Pool or Spa if any suction outlet component (cover/grate) is damaged, broken, cracked,
missing, or not securely attached.
• Immediately replace damaged, broken, cracked, missing, or not securely attached suction outlet
components.
• The CPSP as well as the ICC
specifies the installation of a safety vacuum release system conforming to ASME A112.19.17, or an
approved gravity drain system.
• Failure to remove pressure test plugs and/or plugs used in winterization of the pool/spa from the
suction outlets can result in an increased potential for suction entrapment.
• Failure to keep suction outlet components clear of debris, such as leaves, dirt, hair, paper and other
material can result in an increased potential for suction entrapment.
International Residential Code
Part IX, Appendix G, Section AG106
Suction outlet covers and grates have a finite life. They should be inspected frequently and
replaced within specified life.
SAVE THESE INSTRUCTIONS
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Page 3 of 12 SWIMCLEAR™ CARTRIDGE FILTER ISC2031 REV A
GENERAL INFORMATION
Your Hayward SwimClearTM cartridge filter combines superior water filtration with ease of operation and totally
corrosion-resistant construction. With filtration ratings to 9000 gallons (34,000 liters) per hour, they are
designed for continuous or intermittent operation, for installation above or below the pool water line, for fresh
or salt water swimming pools or spas. SwimClear™ filters utilize multiple reusable, reinforced polyester filter
cartridge elements to provide a high degree of water clarity and long filter cycles with minimum care.
6. Connect the pump discharge (pump OUTLET) to the top port of the filter (filter INLET).
7. Connect the bottom filter port (filter OUTLET) to the pool return plumbing lines.
8. Do not locate pump controls over or near filter.
9. Verify water discharge from the manual air relief valve(MAR) is directed away from electrical devices.
This product should be installed and
serviced only by a qualified pool
professional.
1. The filter system should be
installed on a
other rigid base. Select a well
drained and vented area, one that
does not flood when it rains.
Position the filter so that the piping
connections, and winter drain are
convenient and accessible for
operation, service, maintenance
and winterizing.
2. Position filter body such that all
operation and safety labels are
visible.
3. Position filter so the filter will drain
by gravity.
4. If practical, place pump and filter in
the shade to shield it from
continuous, direct heat from the
sun.
5. Connect the pool suction plumbing
between the skimmer, pool suction
outlet (from the pool) and the
pump.
level concrete slab or
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Page 4 of 12 SWIMCLEAR™ CARTRIDGE FILTER ISC2031 REV A