HAYWARD SP2600X5, SP2605X7, SP2607X10, SP2610X15, SP2615X20 User Manual

...
P/N: ISSPSERIES
REV. A
__________________________________________________________________________________________
OWNER’S MANUAL
*50HZ Models are not UL or CSA Listed.
Super Pump
The Hayward Super PumpTM is specifically engineered for the demanding requirements of today’s in-ground swimming pool/spa that is equipped with large capacity filters, heaters, and pool cleaning equipment. The Super is a self-priming pump that incorporates an improved seal and impeller design that will provide many years of efficient, dependable, corrosion-free service. The advanced design provides superior performance while reducing maintenance requirements.
To prevent potential injury and to avoid unnecessary service calls, read this manual carefully and completely.
Series
WARNING This product should be installed and serviced only by a qualified professional. CAUTION A licensed electrician MUST complete, in full, all electrical installations noted in this manual.
SAVE THIS INSTRUCTION MANUAL
Use of non-Hayward replacement parts voids warranty.
ATTENTION INSTALLATION, OPERATION, AND SAFE USE OF THIS PUMP THAT MUST BE FURNISHED TO THE END USER OF THIS PRODUCT. FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS COULD RESULT IN SERIOUS INJURY.
INSTALLER THIS MANUAL CONTAINS IMPORTANT INFORMATION ABOUT THE
HAYWARD POOL PRODUCTS, INC.
620 DIVISION STREET ELIZABETH, NJ 07207 (908) 351-5400
WWW.HAYWARDPOOL.COM
WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Super Pump ™ Series ____ ____ _____ _ Page 2 of 15
WARNING – Read and follow all instructions in this
owner’s manual and on the equipment. Failure to follow instructions can cause severe injury and/or death.
IMPORTANT SAFETY INSTRUCTIONS
Basic safety precautions should always be followed, including the following: Failure to follow instructions may result in injury.
This is the safety-alert symbol. When you see this symbol on your pump or in this manual, look for one of the
following signal words and are alert to the potential for personal injury.
WARNING warns about hazards that could cause serious personal injury, death or major property
damage and if ignored presents a potential hazard.
CAUTION warns about hazards that will or can cause minor or moderate personal injury and/or property
damage and if ignored presents a potential hazard. It can also make consumers aware of actions that are unpredictable and unsafe.
The NOTICE label indicates special instructions that are important but not related to hazards.
WARNINGTo reduce risk of injury, do not permit children to use or climb on this product. Closely supervise children
at all times. Components such as the filtration system, pumps, and heaters must be positioned to prevent children from using them as a means of access to the pool.
Before installing or servicing this electrical equipment, turn power supply OFF.
CAUTIONThis pump is intended for use on permanently installed swimming pools and may also be used with hot tubs
and spas if so marked. Do NOT use with storable pools. A permanently installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage. A storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity.
Though this product is designed for outdoor use, it is strongly advised to protect the electrical components from the weather. Select a well-drained area, one that will not flood when it rains. It requires free circulation of air for cooling. Do not install in a damp or non­ventilated location. If installed within an outer enclosure or beneath the skirt of a hot tub or spa, adequate ventilation and free circulation of air must be provided to prevent overheating of the motor.
WARNINGPool and spa components have a finite life. All components should be inspected frequently and replaced at
least every ten years, or if found to be damaged, broken, cracked, missing, or not securely attached.
WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Super Pump™ Series _____ _____ _____
_____
_____________________Pag
e 3 of 15
WARNING – It is required that licensed electricians do all electrical wiring. Risk of
Electric Shock. Hazardous voltage can shock, burn, cause death or serious property damage. To reduce
the risk of electric shock, do NOT use an extension cord to connect unit to electric supply. Provide a properly located outlet. All electrical wiring MUST be in conformance with applicable local and national codes and regulations. Before working on pump or motor, turn off power supply to the pump.
WARNING To reduce the risk of electric shock replace damaged wiring immediately. Locate conduit to prevent abuse
from lawn mowers, hedge trimmers and other equipment.
WARNINGA licensed electrician must install a Ground Fault Circuit Interrupter (GFCI) in circuit. For size of GFCI
required and test procedures for GFCI, see manufacturer’s instructions. Pump MUST be permanently connected to GFCI.
WARNINGFailure to bond pump to pool structure will increase risk for electrocution and could result in injury or
death. To reduce the risk of electric shock, the electrician must comply with installation instructions and must bond the pump accordingly. In addition, the licensed electrician must also conform to local electrical codes for bonding requirements.
Notes to the electrician:
Use a solid copper conductor, size 8 or larger. Run a continuous wire from external bonding lug to reinforcing rod or mesh. Connect a No. 8 AWG (8.4 mm parts of swimming pool, spa, or hot tub, and to all electrical equipment, metal piping (except gas piping), and conduit within 5 ft. (1.5 m) of inside walls of swimming pool, spa, or hot tub. IMPORTANT - Reference NEC codes for all wiring standards including, but not limited to, grounding, bonding and other general wiring procedures. NOTE - The National Electrical Code (NEC) permits use of a cord with a maximum 3 ft. (1 m) length. If your pump is equipped with a cord complying with the NEC, the preceding four (4) hazards apply.
2
) solid copper bonding wire to the pressure wire connector provided on the motor housing and to all metal
WARNINGSuction Entrapment Hazard.
Suction in suction outlets and/or suction outlet covers, which are damaged, broken, cracked, missing, or unsecured cause severe injury and/or death due to the following entrapment hazards:
Hair Entrapment- Hair can become entangled in suction outlet cover. Limb Entrapment- A limb inserted into an opening of a suction outlet sump or suction outlet cover that
is damaged, broken, cracked, missing, or not securely attached can result in a mechanical bind or swelling of the limb.
Body Suction Entrapment- A pressure applied to a large portion of the body or limbs can result in an entrapment. Evisceration/ Disembowelment- A negative pressure applied directly to the intestines through an unprotected suction outlet
sump or suction outlet cover which is damaged, broken, cracked, missing, or unsecured can result in evisceration/disembowelment. Mechanical Entrapment- There is potential for jewelry, swimsuits, hair decorations, fingers, toes, or knuckles to be caught in an opening of a suction outlet cover resulting in mechanical entrapment.
WARNING - To Reduce the risk of Entrapment Hazards:
- When outlets are small enough to be blocked by a person, a minimum of two functioning suction outlets per pump must be installed. Suction outlets in the same plane (i.e. floor or wall), must be installed a minimum of three feet (3’) [0.91 meter] apart, as measured from near point to near point.
- Dual suction fittings shall be placed in such locations and distances to avoid “dual blockage” by a user.
- Dual suction fittings shall not be located on seating areas or on the backrest for such seating areas.
- The maximum system flow rate shall not exceed the values shown in the “Pipe Sizing Chart” found at the bottom of page 5 of this manual.
- Never use pool or spa if any suction outlet component is damaged, broken, cracked, missing, or not securely attached.
- Replace damaged, broken, cracked, missing, or not securely attached suction outlet components immediately.
- In addition to two or more suction outlets per pump installed in accordance with latest IAF (formerly NSPI) standards and CPSC guidelines, follow all national, state, and local codes applicable.
- Installation of a vacuum release or vent system, which relieves entrapping suction, is recommended.
WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Super Pump™ Pump Series __________ _____ ________________________ Page 4 of 15
WARNINGHazardous Pressure. Pool and spa water circulation systems operate under
hazardous pressure during start-up, normal operation, and after pump shut-off. Stand clear of circulation system equipment during pump start-up. Failure to follow safety and operation instructions could result in violent separation of the pump housing and cover due to pressure in the system, which could cause property damage, severe personal injury, or death. Before servicing pool and spa water circulation system, all system and pump controls must be in off position and filter manual air relief valve must be in open position. Before starting system pump, all system valves must be set in a position to allow system water to
return back to the pool. Do not change filter control valve position while system pump is running. Before starting system pump, fully open filter manual air relief valve. Do not close filter manual air relief valve until a steady stream of water (not air or air and water) is discharged. All suction and discharge valves MUST be OPEN when starting the circulation system. Failure to do so could result in severe personal injury and/or property damage.
WARNING Separation Hazard. Failure to follow safety and operation instructions could
result in violent separation of pump components. Strainer cover must be properly secured to pump housing
with strainer cover lock ring. Before servicing pool and spa circulation system, all system and pump
controls must be in off position and filter manual air relief valve must be in open position. Do not operate
pool and spa circulation system if a system component is not assembled properly, damaged, or missing. Do
not operate pool and spa circulation system unless filter air relief valve body is in locked position in filter
upper body. All suction and discharge valves MUST be OPEN when starting the circulation system.
Failure to do so could result in severe personal injury and/or property damage.
WARNINGThis pump is not designed to be pressure tested. However, the remainder of the circulation system shall
not be tested or operated at any higher pressure than 50 psi.
WARNINGFire and burn hazard. Motors operate at high temperatures and if they are not properly isolated from
any flammable structures or foreign debris they can cause fires, which may cause severe personal injury or death. It is also necessary to allow the motor to cool for at least 20 minutes prior to maintenance to minimize the risk for burns.
WARNINGFailure to install according to all defined instructions may result in severe personal injury or death.
General Information
Introduction
This manual contains information for the proper installation and operation of the Hayward Super PumpTM Series. The instructions in this manual MUST be followed precisely. Failure to install according to defined instructions will void
warranty.
Product Benefits
Super-sized 110 cubic-inch basket has extra leaf-holding capacity and extends time between cleanings. Rigid
construction with load extender ribbing assures free flowing operation for heavy debris loads.
Exclusive swing-aside hand knobs make strainer cover removal simple and easy. Lexan see-thru strainer cover lets you see when the basket needs cleaning. All components molded of corrosion-proof PermaGlass XL™ for extra durability and long life. Uni-bracket mounting base provides stable, stress-free support, plus versatility for any installation requirement. Adapts
to 48 and 56 frame motors.
Heat resistant, industrial size ceramic seal. Rugged, one-piece housing, with full-flow ports, assures rapid priming and continuous operation. Service-ease design gives simple access to all internal parts. Motor and entire drive group assembly can be removed,
without disturbing pipe or mounting connections, by disengaging just four (4) bolts.
WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Super Pump ™ Series__________ _____ ______________________________Page 5 of 15
Product Specifications
DIMENSION "A" TABLE
PUMP PART
NUMBER SP2600X5 13 3/8" SP2605X7 14"
SP2607X10 14 3/8" SP2610X15 15 1/2" SP2615X20 16 1/2"
SP2621X25 16 1/2" SP2607X102S 17" SP2610X152S 17 1/2" SP2615X202S 18 1/2"
DIMENSION
A
Installation Instructions
WARNING This product should be installed and serviced only by a qualified professional.
Pump Location
Locate pump as close to pool as practical and run suction lines as direct as possible to reduce friction loss. Suction lines should have continuous slope upward from lowest point in line. Joints must be tight (but not over-tightened). Suction line diameter must equal or be larger than the discharge line diameter.
Though the pump is designed for outdoor use, it is strongly advised to protect the electrical components
from the weather. Select a well-drained area, one that will not flood when it rains. Do NOT install pump in a damp or
non-ventilated location. Keep motor clean. Pump motors require free circulation of air for cooling.
Pump Mounting
Install pump on a firm, level base or pad to meet all local and national codes. Fasten pump to base or pad with screws or bolts to further reduce vibration and stress on pipe or hose joints. The base MUST be solid, level, rigid, and vibration free.
Pump mount must:
Allow pump inlet height to be as close to water level as possible. Allow use of short, direct suction pipe (to reduce friction losses). Allow for gate valves in suction and discharge piping. Be protected from excess moisture and flooding.
Pipe Sizing Chart
Allow adequate access for servicing pump and piping.
MAXIMUM RECOMMENDED SYSTEM FLOW RATE BY PIPE SIZE
Pipe Size Flow rate Water Velocity Pipe Size Flow rate Water Velocity
[mm] GPM [Liter/Min] ft/sec [meters/sec] [mm] GPM [Liter/Min] ft/sec [meters/sec]
1 ½” 50.76 8 2 ½” 119.40 8
[50] [192] [2.44] [75] [452] [2.44]
2” 83.65 8 3” 184.32 8
[63] [317] [2.44] [90] [698] [2.44]
IMPORTANT NOTES – No system should allow any higher than 8-ft/sec [2.44 meters/sec] water velocity. It is recommended that a minimum length of piping, equivalent to 10 pipe diameters, be used between the pump suction inlet and any plumbing fittings.
WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS