HAYWARD SP1030 User Manual

IS1030-99A
FRAMES AND GRATES
HAYWARD POOL PRODUCTS, INC.
900 FAIRMOUNT AVENUE, ELIZABETH, NEW JERSEY 07207 / Phone: (908) 351-5400
OWNER’S GUIDE
SP1062
SP1030
SP1030AV
Tested in accordance with ASTM/ANSI Standard A112.19.8M.
MINIMUM DISTANCE
FROM
GRATE TO PIPE
FRAME
SIZE
OUTLET
PIPE SIZE
MODEL NO.
GRATE
SIZE
U.L. FLOW
RATING
NUMBER OF
SECURING
SCREWS
OPEN AREA
REFERENCE
FIGURE
GRATE
PART NO.
SP1062 SP1031 SP1032 SP1033* SP1030 SP1030AV
9” x 9”
9” x 9” 12” x 12” 18” x 18”
7-3/4” 7-3/4”
** ** ** **
252 GPM 252 GPM 252 GPM 252 GPM 148 GPM 108 GPM
4 4 4
16
2 2
44 44 68
176
13
7
sq. in. sq. in. sq. in. sq. in. sq. in. sq. in.
A B B B C D
SP1031B SP1031B SP1032B SP1031B(4) SP1053B SP1048E
3” 3” 3”
3” 1-1/2” or 2” 1-1/2” or 2”
8” 8” 8” 8” 3” 3”
10.47
10.47
13.34
19.38
7.75
7.75
sq. in. sq. in. sq. in. sq. in. sq. in. dia. sq. in. dia.
*Four compartment, heavily Ribbed Frame receives Four (4) 9” x 9” Grates.
**Maximum flow rating obtainable with current U.L. Equipment.
SAFETY INSTRUCTIONS
Please read the following Important Safety Information
Never operate a pool without all main drain covers SECURELY in place.
FAILURE to ensure main drain covers are SECURELY attached could result in SERIOUS BODILY INJURY or DEATH.
Use ONLY the correct Hayward stainless steel screws to secure cover. If screws are lost, order replacements from your supplier.
Building codes require TWO functioning pool drain/suction outlets.
The pool shall not be operated if the suction outlet cover is missing, broken or secured in such a way that it can be removed without the use of tools.
If the suction outlet system, such as a filtration system, booster system, automatic cleaning system, solar system, etc., has a single suction outlet, or multiple suction outlets which can be isolated by valves, each suction outlet shall protect against bather entrapment by either:
A) An antivortex cover, B) A twelve inch by twelve inch (12” x 12”) or larger grate, C) Other means. CAUTION: All drains must be installed according to applicable
codes and standards in effect at time of installation. The open area of the grate must be at least four (4) times the area
of the pipe, or provide sufficient area so the maximum velocity of the water passing through the grate will not exceed two feet (2’) per second. With anti-vortex type outlets, entrance velocities may be increased to six feet (6’) per second.
INSTALLATION INSTRUCTIONS
A sump must be formed for the frame and grate models listed above. (Except for Model SP1062 (Diagram A above) which is provided with a complete main drain sump). This sump must be formed to accept the frame size indicated and be plumbed with the pipe size indicated. The dimension between the top surface of the grate and the center line of the outlet pipe must be, at minimum, the dimension indicated above.
Main Drains for concrete and gunite pools are designed to be plastered flush with edge of grate.
Visit our website at: www.haywardnet.com
Rev. 8/99 B
© 1999 Hayward Printed in U.S.A.
INSTRUCTIONS CONTAIN IMPORTANT SAFETY INFORMATION WHICH MUST BE
FURNISHED TO THE ULTIMATE CONSUMER.