STANDARD INPUTS:
Master Control Panel
Spa-Side Control Panel
Service Control Panel
Air Temperature Sensor
Water Temperature Sensor
3
IMPORTANT WATER SAFETY INSTRUCTIONS
When installing and using these Control Systems, basic safety precautions should always be followed,
including those listed below:
READ AND FOLLOW ALL INSTRUCTIONS
1. WARNING - Risk of Accidental Drowning. Extreme caution must be exercised to prevent unauthorized
access by children. To avoid accidents, ensure that children cannot use the spa or pool to which this Control
System is connected unless they are closely supervised at all times.
2. DANGER - To reduce the risk of drowning from hair or body entrapment, assure that the suction fittings,
skimmers and main drains in the spa or pool connected to this Control System are approved for the
application.
3. DANGER - To reduce the risk of injury, do not remove the suction fittings or main drain covers. Never operate
the spa or pool if these covers are broken or missing.
4. WARNING - To reduce the risk of injury:
A. The water in a spa to which the Control System is connected should never exceed 104°F (40°C). Water
temperatures between 100°F (38°C) and 104°F (40°C) are considered safe for a healthy adult. Lower
water temperatures are recommended for young children and when spa use exceeds 10 minutes.
B. Since excessive water temperatures have high potential for causing fetal damage during the early months
of pregnancy, pregnant or possibly pregnant women should limit spa water temperatures to 100°F (38°C).
C. Before entering a spa, the user should measure the water temperature with an accurate thermometer
since the tolerance of water temperature-regulating devices vary.
D. Prolonged immersion in water hotter than 104°F (40°C) may cause hyperthermia. Hyperthermia occurs
when the internal body temperature reaches a level several degrees above normal body temperature of
98.6°F (37°C). The symptoms of hyperthermia include dizziness, fainting, drowsiness, lethargy, and an
increase in the internal temperature of the body. The effects of hyperthermia include:
E. The use of alcohol, drugs, or medication can greatly increase the risk of fatal hyperthermia.
F. Leave the spa immediately if nausea, dizziness or headaches occur. Immediately cool the body by taking
a cool shower or by applying cold towels or ice packs. If the symptoms persist, seek medical attention.
G. The use of alcohol, drugs, or medication before or during spa use may lead to unconsciousness with the
possibility of drowning.
H. Obese persons and persons with a history of heart disease, low or high blood pressure, circulatory system
problems, or diabetes should consult a physician before using a spa.
I. Persons using medication should consult a physician before using a spa since some medication may
induce drowsiness or may affect heart rate, blood pressure, and circulation.
5. Occasional users of the spa should be made aware of these important Safety Instructions.
6. WARNING - People with infectious diseases should not use a spa or pool.
7. WARNING - To avoid injury, exercise care when entering and exiting a spa or pool.
8. WARNING - Do not use a spa immediately following strenuous exercise.
9. CAUTION - Maintain water chemistry to provide safe bathing environment.
SAVE THESE INSTRUCTIONS
1. Unawareness of impending hazard.
2. Failure to perceive heat.
3. Failure to recognize the need to exit
the spa.
4. Physical inability to exit the spa.
5. Fetal damage in pregnant women.
6. Unconsciousness resulting in a danger of
drowning.
ELECTRICAL SPECIFICATIONS
POWER SUPPLY:
BASIC 50A MAX.
SYSTEM:
-240 vac, 3 wire plus
ground, 20-50A max.
EXPANDER
CIRCUIT BOARDS:
-120 vac and/or 240
vac, 2 wire plus
ground
Power Supply must be
60Hz.
OPTIONAL INPUTS:
2nd Master Control Panel
pH Sensor
ORP Sensor
Solar Sensor (future)
R.F. Remote Control Panels
for Pool and Spa
OUTPUTS:
BASIC 20-50A MAX. SYSTEM
4 - Motorized Diverter Valves- 24 vac
1 - Gas Heater - 120/240 vac, max amperage 1.5A
1 - Filter Pump - 240 vac, max amperage 14.8A
1 - Cleaner Pump - 240 vac, max amperage 6.2A
1 - Spa Jet Pump - 240 vac, max amperage 11.8A
1 - Pool Lighting Option - 120 vac, max amperage 1.6A
1 - Underwater Lighting System- 120 vac, max
amperage 10.3A
1 - Aux. Lighting System - yard lights,120 vac, max
amperage 10.3A
1 - Fill Valve 24 vac, max amperage 0.3A
EXPANDER CIRCUIT BOARD:
2 - Auxiliary Circuits -120/240 vac, max amperage 16A
each circuit