Hayward Max Flo XL User Manual [it]

IS3200E - Rev I
GUIDE DE L’UTILISATEUR
USER’S GUIDE
MANUAL DEL USUARIO
MANUAL DO UTILIZADOR
ANWENDERHANDBUCH
GEBRUIKERSHANDLEIDING
MANUALE D’USO
ANVÄNDARHANDBOK
HAYWARD POOL EUROPE - 1070 Allée des Chênes - CS 20054 Saint Vulbas - 01154 Lagnieu Cedex - France
POMPE CENTRIFUGE
GUIDE DE L'UTILISATEUR
CONSERVEZ CE MANUEL POUR UNE CONSULTATION ULTÉRIEURE
HAYWARD POOL EUROPE - 1070 Allée des Chênes - CS 20054 Saint Vulbas - 01154 Lagnieu Cedex - France
ATTENTION: Danger Électrique. Le non respect des
instructions suivantes risque de vous exposer à
 
des blessures graves, voire un danger de mort.
APPAREIL DESTINÉ AUX PISCINES
ATTENTION – Débranchez totalement la pompe de l’alimentation secteur avant d’ouvrir le couvercle et de nettoyer le
filtre.
ATTENTION – Toute installation électrique de pompe de piscine nécessite d’être réalisée dans les règles de l’art et
conformément aux normes en vigueur:
F NF C 15-100 GB BS7671:1992 D DIN VDE 0100-702 EW EVHS-HD 384-7-702 A ÖVE 8001-4-702 H MSZ 2364-702:1994 / MSZ 10-533 1/1990 E UNE 20460-7-702 1993, REBT ITC-BT-31 2002 M MSA HD 384-7-702.S2
IRL IS HD 384-7-702 PL PN-IEC 60364-7-702:1999
I CEI 64-8/7 CZ CSN 33 2000 7-702
LUX 384-7.702 S2 SK STN 33 2000-7-702
NL NEN 1010-7-702 SLO SIST HD 384-7-702.S2
P RSIUEE TR TS IEC 60364-7-702
ATTENTION – Vérifiez que la machine est branchée sur une prise 230 V protégée contre les courts-circuits. La pompe
doit également être alimentée par l’intermédiaire d’un transformateur d’isolement ou d’un appareil de courant résiduel (RCD) dont le courant résiduel nominal de fonctionnement ne dépasse pas 30 mA.
ATTENTION – Veillez à ce que les enfants ne puissent pas jouer avec l’appareil. Veillez à placer vos doigts loin des
ouvertures et des parties mobiles, et à empêcher tout objet étranger de pénétrer dans l’appareil.
ATTENTION – Le moteur doit être convenablement relié à la terre. Branchez le conducteur de mise à la terre sur la vis
de mise à la terre, de couleur verte, et utilisez une prise de courant à contact de mise à la terre appropriée pour les appareils à connexion par câbles.
ATTENTION – Utilisez une patte de raccordement pour raccorder le moteur aux autres parties liées à la masse, en
utilisant un conducteur de dimensions appropriées, conformément au code de l’électricité.
ATTENTION – Pendant l’établissement des connexions électriques, consultez le diagramme qui se trouve sous le
couvercle du boîtier de connexions du moteur. Assurez-vous que les connexions électriques sont étanches et imperméables avant de mettre l’appareil en marche. Remettez tous les couvercles en place avant d’utiliser l’appareil.
ATTENTION – Vérifiez que la tension d’alimentation requise pour le moteur correspond bien à celle du réseau de
distribution et que les câbles d’alimentation sont adaptés à la puissance et au courant de la pompe.
ATTENTION – Lire attentivement les instructions de ce manuel et celles figurant sur l’appareil. Le non respect des
consignes pourrait être à l’origine de blessures. Ce document doit être remis à tout utilisateur de piscine qui le conservera en lieu sûr.
ATTENTION – L’utilisation, le nettoyage ou la maintenance de l’appareil par des enfants d’au moins huit ans ou
par des personnes aux aptitudes physiques, sensorielles ou mentales réduites ou un manque d’expérience ou de savoir­faire, devra se faire uniquement après avoir reçu des instructions appropriées et sous la supervision adéquate d’un adulte responsable afin d‘assurer une manipulation en toute sécurité et d’éviter tout risque de danger. Cet appareil doit rester hors de portée des enfants.
ATTENTION – La pompe est prévue pour un fonctionnement continu à une température d’eau maximale de 35°C.ATTENTION – N’utilisez que des pièces détachées d’origine Hayward.ATTENTION – Si le câble d’alimentation est endommagé, il doit être remplacé par le fabricant, son service après vente
ou des personnes de qualification similaire, afin d’éviter un danger.
ATTENTION – Pour débrancher la pompe de l’alimentation secteur, un interrupteur extérieur avec une séparation de
contact sur tous les pôles assurant une déconnexion totale en cas de surtension, catégorie III, doit être intégré dans le boîtier fixe, conformément aux règles applicables aux câblages.
ATTENTION – La pompe de la piscine ne doit jamais être mise en marche si le cordon d’alimentation ou le carter du
boîtier de commande du moteur est endommagé, sous peine de provoquer un choc électrique. Un cordon d’alimentation ou un boîtier de commande du moteur endommagé doit immédiatement être remplacé par un technicien agréé ou une personne qualifiée afin d’écarter tout danger.
ATTENTION – Ce moteur n’est PAS équipé d’un SVRS (Système de Sécurité Antiplaquage). Le SVRS aide à empêcher
les noyades, lorsque des personnes se trouvent plaquées sur les bouches d’évacuations, sous la surface de l’eau. Dans certaines configurations de piscine, si le corps d’une personne bouche l’évacuation, cette personne risque d’être prise au piège par l’aspiration. Selon la configuration de votre piscine, la réglementation locale peut exiger l’installation d’un SVRS.
N’UTILISEZ QUE DES PIÈCES DÉTACHÉES D’ORIGINE HAYWARD
Page 2 sur 6 Pompe Rev. I
ENREGISTREMENT
Hayward vous remercie vivement pour l'achat de ce produit. Ce manuel contient des informations importantes relatives au fonctionnement et à l'entretien de votre produit. Le conserver pour vous y reportez ultérieurement.
POUR ENREGISTRER VOTRE PRODUIT, RENDEZ-VOUS SUR:
www.hayward.fr/fr/espace-services/enregistrez-votre-produit
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Pour votre information
Enregistrer les informations suivantes pour référence ultérieure, le cas échéant :
1) Date d'achat___________________________________________________________
2) Nom_________________________________________________________________
3) Adresse _____________________________________________________________
4) Code postal___________________________________________________________
5) Courriel______________________________________________________________
6) Numéro partie____________________Numéro de série________________________
7) Distributeur___________________________________________________________
8) Adresse______________________________________________________________
9) Code postal____________________Pays___________________________________
Remarque
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
N’UTILISEZ QUE DES PIÈCES DÉTACHÉES D’ORIGINE HAYWARD
Page 3 sur 6 Pompe Rev. I
GÉNÉRALITÉS
Installer la pompe a bonne distance du bassin pour réduire le plus possible la liaison entre l’aspiration et la pompe, ceci afin de limiter les pertes de charges inutiles et excessives sur le circuit hydraulique. Il faut toutefois impérativement respecter une distance de sécurité demandée par la norme d’installation en vigueur (3.5 mètres minimum pour respecter la norme NF C 15-100). Installer et utiliser le produit à une altitude inférieur à 2000m
3,5 m
1,50 m
OK
ZONE 2 ZONE 2
2,50 m
1,50 m
2,00 m
ZONE 1
ZONE 0
2,50 m
1,50 m
2,00 m
OK
1,50 m
ZONE 0
Installer la pompe dans un local ventilé et sec, le moteur exige que l’air circule librement autour de celle-ci pour permettre sa ventilation naturelle. Vérifier régulièrement que des objets, des feuilles ou tout autre encombrant ne viennent pas obstruer le refroidissement du moteur. La pompe doit être installée de manière que l’interrupteur extérieur de déconnexion qui est intégré dans le boîtier fixe soit visible et facilement accessible. L’interrupteur doit être situé près de la pompe. La pompe doit être installée en permanence sur un socle en béton grâce à des tire-fonds de Ø 8 mm adaptés au béton, vissés aux emplacements où des trous d’implantation ont été réalisés. Des rondelles d’arrêt doivent être prévues pour empêcher tout desserrement des tire-fonds de montage avec le temps. Si la pompe doit être montée sur un plancher en bois, des vis à bois à tête hexagonale de Ø 8 mm adaptées pour le bois doivent être utilisées – ainsi que des rondelles freins destinées à empêcher tout desserrement dans le temps. La pression acoustique des pompes Hayward est inférieure à 70 dB ( A ).
Dispositions nécessaires:
• Raccorder la pompe à la terre : Ne jamais faire fonctionner la pompe sans que celle-ci soit raccordée à la terre.
• Raccorder la pompe avec un câble souple 3G1mm² de type H07RN-F de diamètre de gaine extérieur maxi 7,8 mm.
• Prévoir un dispositif de protection différentiel 30 mA, destiné à protéger les personnes contre les chocs électriques provoqués par une éventuelle rupture de l’isolation électrique de l’équipement.
• Prévoir une protection contre les courts circuits (la définition du calibre est faite en fonction de la valeur relevée sur la plaque du moteur).
• Prévoir un moyen de déconnexion du réseau d’alimentation ayant une distance d’ouverture des contacts de tous les pôles assurant une coupure complète dans les conditions de catégorie de surtension III.
Moteur électrique Monophasé :
Les moteurs électriques monophasés qui équipent nos pompes sont pourvues d’une protection thermique, cette protection réagit lors d’une surcharge ou échauffement anormal du bobinage moteur. Cette protection se réarme automatiquement lorsque la température du bobinage baisse.
Moteur électrique Triphasé :
Sur les moteurs triphasés, la protection thermique interne (bornier à vis commande du contacteur de puissance de la pompe.
) est à raccorder en série dans la ligne de
Vérifier le sens de rotation du moteur avant le raccordement définitif du moteur de pompe. (une étiquette est prévue à cet effet et apposée sur le corps du moteur, celle ci mentionnant le sens de rotation du moteur) Si la réglementation l’impose et quel que soit le type de moteur utilisé, il faut en plus des dispositifs énumérés ci dessus, installer une protection magnéto-thermique qui doit être calibrée selon les indications de la plaque moteur. Le tableau en page 108 donne les différentes caractéristiques des moteurs qui équipent nos pompes.
N’UTILISEZ QUE DES PIÈCES DÉTACHÉES D’ORIGINE HAYWARD
Page 4 sur 6 Pompe Rev. I
Raccordement électrique :
S’assurer que la tension d’alimentation exigée par le moteur correspond à celle du réseau de distribution et que la section et longueur du câble d’alimentation sont adaptées à la puissance et a l’intensité de la pompe. L’ensemble des raccordements électriques de la pompe ainsi que l’éventuel changement du câble d’alimentation doivent être réalisés par un professionnel qualifié afin d’éviter tout danger. Pour réaliser ces raccordements électriques, se reporter au schéma qui figure sous le couvercle de la plaque a bornes du moteur. Bien vérifier le serrage et l’étanchéité des connexions électriques avant la mise sous tension. Le pré-câblage éventuel qui équipe certaines de nos pompes doit être retiré lors du raccordement définitif de la pompe à l’alimentation électrique. En effet ce pré équipement n’est utilisé que pour les tests en usine pendant les phases de fabrication.
INSTALLATION
Installer la pompe de la piscine en limitant au maximum les pertes de charges tout en respectant les conditions d’éloignement, 3,5 m minimum entre celle-ci et la piscine comme précisé dans la norme d’installation NF C 15-100. La conduite d’aspiration doit être installée avec une faible pente ascendante vers l’axe de la pompe. S’assurer que les raccords soient bien serrés et étanches. Toutefois, éviter de bloquer ces tuyauteries d’une façon exagérée. Pour les matières plastiques, assurer l’étanchéité avec du Téflon uniquement. Le tuyau d’aspiration aura un diamètre plus grand ou au moins égal a celui du refoulement. Éviter des emplacements non ventilés ou humides. Le moteur exige que l’air de refroidissement puisse circuler librement.
IMPORTANT : Vérifier le sens de rotation avant le raccordement définitif du moteur.
INSTRUCTIONS DE DÉMARRAGE ET D’AMORÇAGE : Remplir d’eau le corps du pré-filtre jusqu’au niveau du tuyau
d’aspiration. Ne jamais faire fonctionner la pompe sans eau, cette eau étant nécessaire au refroidissement et a la lubrification de l’obturateur mécanique. Ouvrir toutes les vannes des conduites d’aspiration et de refoulement, de même que la purge d’air du filtre s’il en est pourvu. (Toute présence d’air dans les conduites d’aspiration devra être éliminée). Démarrer le groupe et attendre un temps raisonnable pour l’amorçage. Cinq minutes n’est pas un laps de temps exagéré pour amorcer (cet amorçage dépend de la hauteur d’aspiration et de la longueur du tuyau d’aspiration). Si la pompe ne démarre pas ou ne s’amorce pas voir le guide de recherche des pannes.
ENTRETIEN
1. Débranchez totalement la pompe de l’alimentation secteur avant d’ouvrir le couvercle et de nettoyer le pré-filtre. Nettoyer le panier du pré-filtre régulièrement, ne pas frapper sur le panier pour le nettoyer. Vérifier le joint du couvercle du pré-filtre et le remplacer si nécessaire.
2. L’axe de moteur est monté sur roulements auto-lubrifiants qui ne nécessitent aucune lubrification ultérieure.
3. Garder le moteur propre et sec et s’assurer que les orifices de ventilation soient libres de toute obstruction.
4. Occasionnellement l’obturateur mécanique peut accuser une fuite et devra alors être remplacé.
5. A l’exception du nettoyage de la piscine, toutes les opérations de réparation, d’entretien ou de maintenance doivent être impérativement effectuées par un agent agréé par Hayward ou une personne qualifiée.
HIVERNAGE
1. Vider la pompe en enlevant tous les bouchons de vidange et les conserver dans le panier du pré-filtre.
2. Déconnecter la pompe, enlever les raccords de tuyauteries et conserver le groupe complet dans un endroit sec et aéré ou au moins prendre la précaution suivante: déconnecter la pompe, enlever les boulons de fixation du corps de pompe au support du moteur et conserver l’ensemble dans un endroit sec et aéré. Protéger ensuite le corps de pompe et de pré-filtre en les couvrant.
NOTE : Avant de remettre la pompe en service, nettoyer toutes les parties internes en enlevant la poussière, le tartre, etc.
N’UTILISEZ QUE DES PIÈCES DÉTACHÉES D’ORIGINE HAYWARD
Page 5 sur 6 Pompe Rev. I
PANNES POSSIBLES ET SOLUTIONS
A) Le moteur ne démarre pas
1. Vérifier les raccordements électriques, les interrupteurs ou relais, de même que les coupe-circuit ou fusibles.
2. S’assurer manuellement de la libre rotation du moteur.
B) Le moteur s’arrête, vérifier
1. Les câbles, connections, relais, etc.
2. La chute de tension au moteur (fréquemment causée par des câbles trop faibles).
3. Qu’il n’apparaît aucun grippage ou surcharge (par lecture de l’ampérage absorbé).
NOTE : Le moteur de votre pompe est équipé d’une protection thermique qui, en cas de surcharge, coupera automatiquement le circuit et évitera que le moteur ne se détériore. Ce déclenchement est causé par des conditions anormales d’utilisation qu’il est nécessaire de vérifier et de corriger. Le moteur redémarrera sans aucune intervention des que les conditions normales de fonctionnement seront rétablies.
C) Le moteur grogne mais ne démarre pas, vérifier si : une phase n’est pas coupée, le condensateur n’est pas détérioré.
D) La pompe ne s’amorce pas
1. S’assurer que le corps du pré-filtre est bien rempli d’eau, que le joint du couvercle est propre et bien positionné et qu’aucune entrée d’air n’est possible. Au besoin, resserrer les vis de blocage de couvercle.
2. S’assurer que toutes les vannes d’aspiration et de refoulement sont ouvertes et non obstruées, et que toutes les bouches d’aspiration de la piscine sont entièrement immergées.
3. Vérifier si la pompe aspire en dégageant l’aspiration le plus près possible de la pompe:
a) si la pompe n’aspire pas malgré un remplissage suffisant en eau d’amorçage
1. Resserrer les boulons et accessoires de tuyauterie du côté aspiration.
2. Vérifier la tension pour s’assurer que la pompe tourne à la bonne vitesse.
3. Ouvrir la pompe et vérifier que rien n’obstrue à l’intérieur,
4. Remplacer l’obturateur mécanique. b) Si la pompe aspire normalement, vérifier la conduite d’aspiration et le pré-filtre qui pourraient être bouchés ou
occasionner des prises d’air.
E) Chutes de débit, généralement vérifier :
1. Si aucun engorgement ou restriction n’apparaît dans les conduites d’aspiration ou dans le préfiltre et si le diamètre des conduites n’est pas insuffisant.
2. Si aucun engorgement ou restriction n’apparaît dans les conduites de refoulement ou dans les filtres (dans ce cas, le manomètre de refoulement accusera une très forte hausse de pression).
3. Si aucune prise d’air n’existe a l’aspiration (dans ce cas, vérifier l’absence de bulles d’air au refoulement ou au travers du couvercle du préfiltre).
4. Si la pompe fonctionne a trop faible vitesse (chute de tension).
F) Pompe bruyante, vérifier
1. Si aucune entrée ou présence d’air a l’aspiration ne provoque de crépitements sourds dans la pompe.
2. S’il n’apparaît aucune cavitation causée par un diamètre insuffisant ou une restriction de la conduite d’aspiration. De même une conduite sur-dimensionnée au refoulement peut causer cette cavitation. Utiliser des tuyauteries correctes ou purger les conduites, si nécessaire.
3. S’il n’apparaît aucune vibration causée par un montage incorrect.
4. Si aucun corps étranger ne se trouve dans le corps de la pompe.
5. Si les roulements du moteur ne sont pas grippés par un jeu trop important, par la rouille ou par une surchauffe prolongée.
N’UTILISEZ QUE DES PIÈCES DÉTACHÉES D’ORIGINE HAYWARD
Page 6 sur 6 Pompe Rev. I
CENTRIFUGAL PUMP
USER GUIDE
KEEP THIS MANUAL FOR FUTURE REFERENCE
HAYWARD POOL EUROPE - 1070 Allée des Chênes - CS 20054 Saint Vulbas - 01154 Lagnieu Cedex - France
WARNING: Electrical Hazard. Failure to follow
 
instructions can result in serious injury or death.
FOR USE WITH SWIMMING POOLS
WARNING – Disconnect the pump from the main power supply completely before servicing the pump or filter.WARNING – All electrical connections must be done by a qualified electrician according to local electrical standard.
F NF C 15-100 GB BS7671:1992
D DIN VDE 0100-702 EW EVHS-HD 384-7-702
A ÖVE 8001-4-702 H MSZ 2364-702:1994 / MSZ 10-533 1/1990
E UNE 20460-7-702 1993, REBT ITC-BT-31 2002 M MSA HD 384-7-702.S2
IRL IS HD 384-7-702 PL PN-IEC 60364-7-702:1999
I CEI 64-8/7 CZ CSN 33 2000 7-702
LUX 384-7.702 S2 SK STN 33 2000-7-702
NL NEN 1010-7-702 SLO SIST HD 384-7-702.S2
P RSIUEE TR TS IEC 60364-7-702
WARNING – Be certain the machine is only plugged into a protected 230 Voutlet that is protected from short-circuits.
The pump is to be supplied by an isolating transformer or supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30 mA.
WARNING – Children should be supervised to ensure that they do not play with the appliance. Keep ngers and foreign
objects away from openings and moving parts.
WARNING – Motor must be suitably grounded. Connect ground wire to green grounding screw and for cord connected
units use properly grounded outlet.
WARNING – Use a motor bonding lug to connect motor with other bonded parts using the appropriate size conductor
as required by electrical codes.
WARNING – When making these electrical connections, refer to the diagram given under the lid of the motor terminal
box. Be sure to check the electric connections are tight and sealed before powering up. Replace all covers before operation.
WARNING – Make sure that the power supply voltage required by the motor corresponds to that of the distribution
network and that the power supply cables matches the power and current of the pump.
WARNING – Read and follow all instructions in this owner’s manual and on the equipment. Failure to follow
instructions can cause serious injury or death. This document should be given to the owner of the swimming pool and must be kept by the owner in a safe place.
WARNING – The appliance can be used by children aged from 8 years and above and persons with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
WARNING – Cleaning and user maintenance shall not be made by children without supervision.WARNING – The pump is intended for continuous operation at Maximum Water temperature 35°C.WARNING – Use Only Genuine Hayward Replacement Parts.WARNING – If the supply cord is damaged it must be replaced by the manufacturer, service agent, or similarly qualified
persons in order to avoid a hazard.
WARNING – For disconnection from main power supply an external switch having a contact separation in all poles that
provide a full disconnection under overvoltage category III conditions must be incorporated in the fixed wiring in accordance with the wiring rules.
WARNING – Do not operate the swimming pool pump if the power cord or the housing of the motor connection box is
damaged. This can cause an electric shock. A damaged power cord or motor connection box must be replaced by a service agent or a similarly qualified person immediately in order to avoid a hazard.
WARNING – This pool motor is NOT equipped with a Safety Vacuum Release System (SVRS). SVRS helps prevent
drowning due to body entrapment on underwater drains. In some pool configuration, if a person’s body covers the drain, the person can be trapped by suction. Depending on your pool configuration, a SVRS may be required to meet local requirements.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Page 2 of 6 Pump Rev. I
REGISTRATION
Hayward thanks you for buying this product. This manual contains important information regarding the operation and maintenance of your product. Keep it carefully for future reference.
TO REGISTER YOUR PRODUCT, GO TO:
http://www.hayward.fr/en/services/register-your-product
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
For your information
Record the following information future reference, if necessary:
1) Date of purchase_______________________________________________________
2) Name________________________________________________________________
3) Address ______________________________________________________________
4) Post Code_____________________________________________________________
5) Email ________________________________________________________________
6) Part number_______________________Serial number_________________________
7) Dealer _______________________________________________________________
8) Address ______________________________________________________________
9) Post code ____________________Country__________________________________
Note
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Page 3 of 6 Pump Rev. I
GENERAL POINTS
Install the pump at a suitable distance from the pool to reduce the distance between the suction point and the pump as much as possible to avoid pointless excessive pressure drops on the hydraulic circuit. However, it is essential to comply with the safety distance required by the current installation standard (3.5 metres minimum). Install and use the product at an altitude less than 2000m
3.5 m
1,50 m
OK
ZONE 2 ZONE 2
2,50 m
1,50 m
2,00 m
ZONE 1
ZONE 0
2,50 m
1,50 m
2,00 m
OK
1,50 m
ZONE 0
Install the pump in a dry, well-ventilated place. The motor requires the air to circulate freely around it to allow natural ventilation. Check regularly that no objects, leaves or other debris are blocking the motor cooling system. The pump must be installed to ensure that the external disconnection switch incorporated into the fixed unit is visible and easily accessible. The switch must be located near to the pump. The pump must be permanently installed on a concrete base using 8mm lag screws suitable for concrete, screwed into drilled implantation holes. Lock washers must be used to prevent the installation lag screws working loose over time. If the pump has to be mounted on a wooden board, Ø 8mm hexagonal wood screws must be used combined with lock washers to prevent the screws working loose over time. The acoustic pressure of Hayward pumps is less than 70dB (A).
Necessary measures:
• Connect the pump to the earth: Never operate the pump unless it is connected to the earth.
• Connect the pump with a H07RN-F 3G1mm² type cable (D max 7,8mm)
• Include a 30mA differential protection to protect people against electric shocks which may be caused by a breach of the equipment's electrical insulation.
• Include short-circuit protection (the rating is determined according to the value given on the nameplate on the motor).
• Include a means of disconnection from the power supply having an opening distance on the contacts of all the poles ensuring the power supply is completely cut off under the conditions of a category III overvoltage.
Single phase electric motor:
The single phase motors fitted to our pumps are provided with thermal protection. This protection operates on an overload or in the event of abnormal heating of the motor coil and is reset automatically when the winding temperature drops.
Three phase electric motor:
On three phased motors the internal heat protection (screw terminal blocks power contactor command line.
) is to be connected serially in the pump’s
Check the running direction of the pump motor (a label is provided on the motor housing to indicate the motor running direction). If so required by regulations and whatever the motor type, in addition to the devices mentioned above, it is also necessary to install a thereto-magnetic protective device calibrated in accordance with the indications on the motor name-plate. The table on page 108 indicates the various characteristics of the motors fitted to our pumps.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Page 4 of 6 Pump Rev. I
Electrical connection: Make sure that the power supply voltage required by the motor corresponds to that of the distribution network and that the power supply cables matches the power and current of the pump. All the electric connections of the pump and the possible change of power supply cable must be hand-led by a qualified professional so as to avoid all possible danger. When making these electrical connections, refer to the diagram given under the lid of the motor terminal box. Be sure to check the electric connections are tight and sealed before powering up. The pre-wiring that might be included on some of the pumps must be removed for final connection of the pump to the electric power supply. This pre-equipment is only used for works testing during the manufacturing phases.
INSTALLATION
Install the pool pump so as to reduce pressure drops to a minimum whilst complying with the distances specified in the installation standard, namely 3.5m minimum between the pump and the pool. The suction pipe must be installed with a slight uphill incline towards the pump axis. Ensure that the connections are correctly tightened and watertight. However, avoid excessively tightening the pipes. For plastic materials, use Teflon only to ensure watertightness. The diameter of the suction pipe shall depend on that of the discharge pipe. Avoid damp or non-ventilated locations. The motor requires the cooling air to circulate freely.
IMPORTANT: Check the direction of rotation before permanently connecting the motor.
INSTRUCTIONS FOR START-UP AND PRIMING: Fill the body of the strainer with water up to the level of the suction pipe.
Never run the pump without water, as the water is necessary for cooling and lubrication of the mechanical shutter. Open all the suction and discharge pipe valves, and the filter air purge valve if there is one. (Any air in the suction pipes must be eliminated). Start up the generator and wait a reasonable time for priming. Five minutes is not excessive for priming (this time depends on the suction head and the length of the suction pipe). If the pump does not start or does not prime, please refer to the troubleshooting guide.
MAINTENANCE
1. Completely disconnect the pump from the mains power supply before opening the cover and cleaning the strainer. Clean the strainer basket regularly. Do not bang on the basket to clean it. Check the seal on the cover of the strainer and replace it if necessary.
2. The motor shaft is mounted on self-lubricating bearings which do not require any subsequent lubrication.
3. Keep the motor clean and dry and ensure the ventilation openings are not blocked.
4. The mechanical shutter occasionally starts to leak and must then be changed.
5. Apart from cleaning the pool, all repairs, servicing and maintenance must be carried out by a Hayward-approved agent or a qualified person.
WINTERING
1. Empty the pump by removing all the drain plugs and store them in the strainer basket.
2. Disconnect the pump, remove the pipe connectors and store the entire unit in a dry, well-ventilated place or at least take the following precaution: disconnect the pump, remove the 4 bolts attaching the pump housing to the motor bracket and store the unit in a dry, well-ventilated place. Then cover the pump housing and strainer to protect them.
N.B.: Before recommissioning the pump, clean all the internal parts to remove dust, lime scale etc.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Page 5 of 6 Pump Rev. I
TROUBLESHOOTING
A) The motor does not start
1. Check the electrical connections, switches or relays, and the circuit breaker or fuses.
2. Ensure that the motor turns freely by hand.
B) The motor stops, check
1. The cables, connections, relays etc.
2. Voltage drop on motor (frequently caused by cables that are too small).
3. That there is no seizing or overheating (by reading the absorbed current).
N.B.: The motor on your pump is fitted with a thermal protection which, in the case of overload, will automatically cut the circuit and avoid the motor being damaged. This triggering is caused by abnormal usage conditions which need to be checked and corrected. The motor will restart without any intervention as soon as normal operating conditions are restored.
C) The motor growls but does not start, check that a phase is not cut, the capacitor is not damaged.
D) The pump does not prime
1. Ensure the strainer housing is filled with water, that the cover seal is clean and correctly positioned and that no air can enter. If necessary, tighten the cover lock screws.
2. Ensure that all the suction and discharge valves are open and not blocked and that the suction outlets in the pool are fully submerged.
3. Check that the pump draws by freeing the suction as close as possible to the pump:
a) if the pump does not draw despite being sufficiently full of priming water
1. Tighten the bolts and pipe accessories on the suction side.
2. Check the voltage to ensure that the pump is rotating at the correct speed.
3. Open the pump and check that nothing is blocking it inside,
4. Replace the mechanical shutter. b) If the pump is drawing normally, check the suction pipe and strainer which may be blocked or be allowing air to enter.
E) Low flow - Generally, Check for :
1. Clogged or restricted strainer or suction line; undersized pool piping.
2. Plugged or restricted discharge line of filter (high discharge gauge reading).
3. Air leak in suction (bubbles issuing from return fittings).
4. Pump operating under speed (low voltage).
5. Plugged or restricted impeller.
F) Noisy pump, check
1. That no air is entering the suction side and causing dull crackling in the pump.
2. That there is no cavitation caused by insufficient diameter or a restriction in the suction tube. An over-sized discharge pipe can also cause cavitation. Use pipes of the correct size or purge the pipes if necessary.
3. That no vibration is occurring due to incorrect fitting.
4. That there are no foreign bodies in the pump housing.
5. That the motor bearings have not seized due to excessive clearance, rust or prolonged overheating.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Page 6 of 6 Pump Rev. I
BOMBA CENTRÍFUGA
MANUAL DEL USUARIO
CONSERVE ESTE MANUAL PARA CONSULTARLO POSTERIORMENTE
HAYWARD POOL EUROPE - 1070 Allée des Chênes - CS 20054 Saint Vulbas - 01154 Lagnieu Cedex - France
ADVERTENCIA: Peligro eléctrico. Un fallo en el
seguimiento de las instrucciones puede dar como
 
resultado una herida seria o la muerte.
PARA USO EN PISCINAS
ADVERTENCIA – Antes de abrir la tapa para la limpieza del filtro, desconectar la bomba completamente del suministro
de alimentación eléctrica.
ADVERTENCIA – Todas las conexiones eléctricas deben ser efectuadas por un electricista profesional autorizado
cualificado y según las normas vigentes en el país de instalación:
F NF C 15-100 GB BS7671:1992
D DIN VDE 0100-702 EW EVHS-HD 384-7-702
A ÖVE 8001-4-702 H MSZ 2364-702:1994 / MSZ 10-533 1/1990
E UNE 20460-7-702 1993, REBT ITC-BT-31 2002 M MSA HD 384-7-702.S2
IRL IS HD 384-7-702 PL PN-IEC 60364-7-702:1999
I CEI 64-8/7 CZ CSN 33 2000 7-702
LUX 384-7.702 S2 SK STN 33 2000-7-702
NL NEN 1010-7-702 SLO SIST HD 384-7-702.S2
P RSIUEE TR TS IEC 60364-7-702
ADVERTENCIA – Asegúrese de que la máquina solamente se conecta a una toma de 230 V protegida contra
cortocircuitos. La bomba se alimentará por medio de un transformador aislante o a través de un dispositivo de corriente residual (DCR) con una corriente de funcionamiento residual nominal que no exceda de 30 mA.
ADVERTENCIA – Asegúrese de que los niños no jueguen con este aparato. Mantenga los dedos y objetos extraños
lejos de las aberturas y las partes móviles.
ADVERTENCIA – El motor debe estar situado en el suelo adecuadamente. Conecte el cable de tierra al tornillo verde
de la base y para las unidades conectadas con cable use correctamente la salida de tierra.
ADVERTENCIA – Utilice una agarradera de conexión al motor para conectar el motor con otras partes de conexión
usando el conductor del tamaño apropiado como se especifica en los códigos eléctricos.
ADVERTENCIA – Cuando realice dichas conexiones eléctricas, revise el diagrama de debajo de la tapa de la caja del
terminal del motor. Asegúrese de comprobar que las conexiones eléctricas están apretadas y selladas antes de conectarlas a la corriente. Retire todas las cubiertas antes de poner en funcionamiento.
ADVERTENCIA – Asegúrese que el voltaje del suministro eléctrico requerido por el motor corresponde al de la red de
distribución y que los cables de suministro eléctrico corresponden a la potencia y la corriente de la bomba.
ADVERTENCIA – Leer y seguir todas las instrucciones contenidas en este manual del propietario e indicadas en el
equipo. La inobservancia de las instrucciones puede causar lesiones corporales. Este documento debe entregarse al propietario de la piscina, el cual deberá conservarlo en un lugar seguro.
ADVERTENCIA – Los niños mayores de 8 años y personas sin el conocimiento o la experiencia necesarios o con
discapacidades físicas, mentales o sensoriales pueden utilizar este aparato si han recibido las instrucciones apropiadas y comprenden los peligros que conlleva su uso. Los niños no deben jugar con el aparato. La limpieza y el mantenimiento del usuario no deberán ser realizados por niños, salvo que sean mayores de 8 años y estén supervisados. Mantenga el aparato y el cable fuera del alcance de niños menores de 8 años.
ADVERTENCIA – La bomba está diseñada para un funcionamiento continuo a temperatura de agua máxima de 35°C.ADVERTENCIA – Use solo piezas de repuesto originales de Hayward.ADVERTENCIA – Si el cable de alimentación está dañado, debe ser sustituido por el fabricante, su concesionario o
personas cualificadas de forma similar, para evitar que se produzcan peligros.
ADVERTENCIA – Debe instalarse un interruptor externo con una separación de contactos en todos los polos que
proporcione una desconexión completa en condiciones de sobretensión de categoría III en el cableado fijo que cumpla con las reglas de cableado para la desconexión del suministro de alimentación eléctrica.
ADVERTENCIA – No operar la bomba de la piscina si el cable de conexión o la carcasa de la caja de conexión del
motor está averiada. Esto puede provocar una descarga eléctrica. Un cable de alimentación o una caja de conexión del motor dañados deben ser sustituidos por un técnico o una persona igualmente cualificada inmediatamente para evitar un peligro.
ADVERTENCIA – Este motor de piscina NO está equipado con un Sistema de seguridad de liberación del vacío
(SSLV). El SSLV ayuda a prevenir ahogamientos a causa de atrapamientos del cuerpo en los drenajes sumergidos. En algunas configuraciones de piscinas, si el cuerpo de una persona cubre el drenaje, la persona puede quedar atrapada por succión. Dependiendo de la configuración de su piscina, puede ser necesario un SSLV para cumplir los requisitos de la normativa local.
USE SOLO PIEZAS DE REPUESTO ORIGINALES DE HAYWARD
Página 2 de 6 Bomba Rev. I
REGISTRO
Hayward le da las gracias encarecidamente por haber comprado este producto Este manual contiene informaciones importantes relativas al funcionamiento y al mantenimiento de su producto. Conservarlo para consultarlo ulteriormente.
PARA REGISTRAR SU PRODUCTO, CONÉCTESE A:
http://www.hayward.fr/es/servicios/registrar-su-producto
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Para su información
Registrar las siguientes informaciones para referencia ulterior, cuando proceda:
1) Date d'achat___________________________________________________________
2) Nombre_______________________________________________________________
3) Dirección _____________________________________________________________
4) Código postal__________________________________________________________
5) Courriel_______________________________________________________________
6) Número parte____________________Número de serie_________________________
7) Distribuidor____________________________________________________________
8) Dirección______________________________________________________________
9) Código postal____________________País __________________________________
Advertencia
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
USE SOLO PIEZAS DE REPUESTO ORIGINALES DE HAYWARD
Página 3 de 6 Bomba Rev. I
GENERALIDADES:
Instalar la bomba a buena distancia de la piscina para reducir al máximo en enlace entre la aspiración y la bomba, esto con el fin de limitar las pérdidas de cargas inútiles y excesivas en el circuito hidráulico. No obstante, deberá respetarse imperativamente una distancia de seguridad exigida por la norma de instalación vigente (3.5 metros como mínimo). Instale y use el producto a una altitud inferior a 2.000 m
3,5 m
1,50 m
OK
ZONA 2 ZONA 2
2,50 m
1,50 m
2,00 m
ZONA 1
ZONA 0
2,50 m
1,50 m
2,00 m
OK
1,50 m
ZONA 0
Instalar la bomba en un local ventilado y seco, el motor exige que el aire circule libremente alrededor de la bomba para que se ventile naturalmente. Comprobar regularmente que no haya objetos, hojas o cualquier otro obstáculo que pudiese obstruir la refrigeración del motor. La bomba debe instalarse de modo que el interruptor exterior de desconexión que está integrado en la caja fija sea visible y fácilmente accesible. El interruptor debe estar situado cerca de la bomba. La bomba debe instalarse permanentemente sobre un zócalo de hormigón con grapones de Ø 8 mm. adaptados al hormigón, atornillados en los emplazamientos donde se realizaron agujeros de implantación. Deben preverse arandelas de retención para impedir que se aflojen los grapones de montaje con el paso del tiempo. Si la bomba debe montarse sobre un suelo de madera, deben utilizarse tornillos de madera hexagonales de Ø 8 mm. adaptados a la madera - así como arandelas freno destinadas a impedir cualquier aflojamiento con el paso del tiempo. La presión acústica de las bombas Hayward es inferior a 70 dB (a).
Disposiciones necesarias:
• Conectar la bomba a la tierra: No hacer nunca funcionar la bomba si no está conectada a la tierra.
• Conecte la bomba con un cable H07RN-F 3G1mm² (D max 7,8mm)
• Prever un dispositivo de protección diferencial 30 mA, destinado a proteger a las personas contra los choques eléctricos provocados por una eventual ruptura del aislamiento eléctrico del equipamiento.
• Prever una protección contra los cortocircuitos (la definición del calibre se hace en función del valor observado en la placa del motor).
• Prever un medio de desconexión de la red de alimentación que tenga una distancia de apertura de los contactos de todos los polos que garantice un corte completo en las condiciones de categoría de sobretensión III.
Motor eléctrico monofásicos:
Los motores eléctricos monofásicos instalados en nuestras bombas constan de una protección térmica, esta protección reacciona durante una sobrecarga o un calentamiento anormal del bobinado motor, esta protección se rearma automáticamente cuando la temperatura del bobinado baja.
Motor eléctrico Trifásico:
En los motores trifásicos, la protección térmica interna (regletas de terminales de tornillo a la línea de mando del contactor de potencia de la bomba
) debe conectarse en serie
Comprobar el sentido de rotación del motor antes de la conexión definitiva del motor de bomba, (una etiqueta está prevista para este efecto y está puesta en el cuerpo del motor, ésta menciona el sentido de rotación del motor). Si la reglamentación lo impone y cualquiera que sea el tipo de motor utilizado, además de los dispositivos mencionados anteriormente, hay que instalar una protección magneto térmica que debe ser calibrada según las indicaciones de la placa motor. El cuadro en página 108 proporciona las diferentes características de los motores de nuestras bombas.
USE SOLO PIEZAS DE REPUESTO ORIGINALES DE HAYWARD
Página 4 de 6 Bomba Rev. I
Conexión eléctrica: distribución y que la sección y la longitud del cable de alimentación se adaptan a la potencia e intensidad de la bomba. El conjunto de las conexiones eléctricas de la bomba así como el eventual ‘cambio del cable de alimentación deben ser efectuados por un profesional cualificado con objeto de evitar todo peligro. Para efectuar estas conexiones eléctricas, véase el esquema colocado por debajo de la tapa de la placa con bornas del motor. Comprobar bien el apriete y la hermeticidad de las conexiones eléctricas antes del encendido. El precableado eventual de algunas de nuestras bombas debe retirarse para la conexión definitiva de la bomba a la alimentación eléctrica. En efecto, este preequipo sólo se utiliza para las pruebas en fábrica durante las fases de fabricación.
Cerciorarse de que la tensión de alimentación exigida por el motor corresponde a la de la red de
INSTALACIÓN
Instalar la bomba de la piscina limitando al máximo las pérdidas de cargas y respetando al mismo tiempo las condiciones de alejamiento, 3,5 m como mínimo según la norma de instalación. El conducto de aspiración debe instalarse con poca pendiente ascendente hacia el eje de la bomba. Asegurarse que las conexiones estén bien prietas y sean estancas. No obstante, evitar bloquear estas tuberías de modo exagerado Para las materias plásticas, asegurar la estanqueidad con Teflón únicamente. El tubo de aspiración tendrá un diámetro mayor o al menos igual al de la descarga. Evitar emplazamientos no ventilados o húmedos. El motor exige que el aire de refrigeración pueda circular libremente.
IMPORTANTE: Comprobar el sentido de rotación antes de conectar definitivamente el motor.
INSTRUCCIONES DE ARRANQUE Y CEBADO:
No hacer funcionar nunca la bomba sin agua, este agua es necesaria para la refrigeración y la lubricación del obturador mecánico. Abrir todas las válvulas de los conductos de aspiración y descarga, así como la purga de aire del filtro si está previsto. (Toda presencia de aire en los conductos de aspiración deberá eliminarse). Arrancar el grupo y esperar un tiempo razonable para el cebado. Cinco minutos no es un plazo de tiempo exagerado para cebar (este cebado depende de la altura de aspiración y la longitud del tubo de aspiración). Si la bomba no arranca o no se ceba consultar la guía de búsqueda de las averías.
Llenar de agua el cuerpo del pre-filtro hasta el nivel del tubo de aspiración.
MANTENIMIENTO
1. Desconecte completamente la bomba de la alimentación sector antes de abrir la tapa y limpiar el prefiltro. Limpiar la cesta del prefiltro regularmente, no golpear la cesta para limpiarla. Comprobar la junta de la tapa del prefiltro y cambiarla si fuera necesaria.
2. El eje de motor está montado sobre rodamientos autolubricantes que no requieren ninguna lubricación posterior.
3. Guardar el motor limpio y seco y asegurarse de que los orificios de ventilación no tengan nada que los obstruya.
4. De vez en cuando el obturador mecánico puede acusar una fuga y deberá entonces sustituirse.
5. Con excepción de la limpieza de la piscina, todas las operaciones de reparación, mantenimiento o conservación deben ser efectuadas imperativamente por un inspector autorizado por Hayward o una persona cualificada.
INVERNADA
1. Vaciar la bomba retirando todos los tapones de vaciado y conservarlos en la cesta del filtro.
2. Desconectar la bomba, retirar los empales de las tuberías y conservar el grupo completo en un lugar seco y ventilado o al menos tomar la siguiente precaución: desconectar la bomba, retirar los 4 tornillos de fijación del cuerpo de bomba al soporte del motor y conservar el conjunto en un lugar seco y ventilado. Seguidamente, cubrir el cuerpo de bomba y de prefiltro para protegerlos.
NOTA: Antes de volver a poner la bomba en servicio, limpiar todas las partes internas retirando el polvo, el calcáreo, etc.
USE SOLO PIEZAS DE REPUESTO ORIGINALES DE HAYWARD
Página 5 de 6 Bomba Rev. I
EVENTUALES AVERÍAS Y SOLUCIONES
A) El motor no arranca
1. Comprobar las conexiones eléctricas, los interruptores o relés, así como el cortacircuitos o fusibles.
2. Asegurarse manualmente de la libre rotación del motor.
B) El motor se para, comprobar
1. Los cables, conexiones, relés, etc.
2. La caída de tensión al motor (frecuentemente causada por cables débiles)
3. Que no aparezca ningún gripado o sobrecarga (por lectura del amperaje absorbido)
NOTA: El motor de su bomba está equipado de una protección térmica que, en caso de sobrecarga, cortará automáticamente el circuito y evitará que el motor no se deteriore. Este desenganche está causado por condiciones anormales de utilización que es necesario comprobar y corregir. El motor volverá a arrancar sin ninguna intervención en cuanto se restablezcan las condiciones normales de funcionamiento.
C) El motor intenta ponerse en marcha pero no arranca, vcomprobar si: una fase no está cortada, el condensador no
está deteriorado.
D) La bomba no se ceba
1. Asegurarse que el cuerpo del prefiltro esté bien lleno de agua, que la junta de la tapa esté limpia y bien colocada y que no sea posible ninguna entrada de aire. Si fuera necesario, apretar los tornillos de bloqueo de la tapa
2. Asegurarse de que todas las válvulas de aspiración y descarga están abiertas y no bloqueadas, y que todas las bocas de aspiración de la piscina estén bien sumergidas.
3. Comprobar si la bomba aspira liberando la aspiración lo más cerca posible de la bomba
a) si la bomba no aspira a pesar de un llenado suficiente en agua de cebado
1. Apretar los pernos y accesorios de tubería del lado aspiración.
2. Comprobar la tensión para asegurarse de que la bomba gira a buena velocidad.
3. Abrir la bomba y comprobar que nada obstruya el interior,
4. Reemplazar el obturador mecánico b) Si la bomba aspira normalmente, comprobar el conducto de aspiración y el prefiltro que podrían estar obstruidos u
ocasionar tomas de aire.
E) Disminución del caudal: En este caso verificar:
1. Que no existe estrangulamiento o retention en las tuberías de aspiración o en el prefiltro; que el diámetro de las tuberías es suficiente.
2. Que no existe ningún estrangulamiento o retention en las tuberías de impulsión o en los filtros (en este caso, el manómetro en la impulsión indicara una subida de presión muy alta).
3. Que no existe ninguna toma de aire en la aspiración (en este caso el agua contendrá burbujas de aire en la impulsión o bien a través de la tapa del prefiltro).
4. Que la bomba no funcione a muy baja velocidad (caída de tensión).
F) Bomba ruidosa, comprobar
1. Si ninguna entrada o presencia de aire en la aspiración causa crujidos sordos en la bomba.
2. Si no aparece ninguna cavitación causada por un diámetro insuficiente o una restricción del conducto de aspiración. Así mismo un conducto sobredimensionado en la descarga puede causar esta cavitación. Utilizar tuberías correctas o purgar los conductos, si fuera necesario.
3. Si no aparece ninguna vibración causada por un montaje incorrecto
4. Si no se encuentra ningún cuerpo extraño en el cuerpo de la bomba
5. Si los rodamientos del motor no están gripados por un juego demasiado importante, por el óxido o por un recalentamiento prolongado.
USE SOLO PIEZAS DE REPUESTO ORIGINALES DE HAYWARD
Página 6 de 6 Bomba Rev. I
BOMBA CENTRÍFUGA
MANUAL DO UTILIZADOR
CONSERVE ESTE MANUAL PARA REFERÊNCIA FUTURA
HAYWARD POOL EUROPE - 1070 Allée des Chênes - CS 20054 Saint Vulbas - 01154 Lagnieu Cedex - France
AVISO: Perigo eléctrico. O não cumprimento das
instruções pode dar origem a ferimentos graves
 
ou morte.
PARA UTILIZAÇÃO EM PISCINAS
AVISO – Antes de abrir a tampa para limpar o filtro, desligue totalmente a bomba da alimentação eléctrica principal.AVISO – Todas as ligações eléctricas devem ser realizadas por um electricista profissional aprovado e devidamente
habilitado e de acordo com as normas em vigor no país de instalação:
F NF C 15-100 GB BS7671:1992
D DIN VDE 0100-702 EW EVHS-HD 384-7-702
A ÖVE 8001-4-702 H MSZ 2364-702:1994 / MSZ 10-533 1/1990
E UNE 20460-7-702 1993, REBT ITC-BT-31 2002 M MSA HD 384-7-702.S2
IRL IS HD 384-7-702 PL PN-IEC 60364-7-702:1999
I CEI 64-8/7 CZ CSN 33 2000 7-702
LUX 384-7.702 S2 SK STN 33 2000-7-702
NL NEN 1010-7-702 SLO SIST HD 384-7-702.S2
P RSIUEE TR TS IEC 60364-7-702
AVISO – Certifique-se de que a máquina só é ligada a uma tomada protegida de 230 V que esteja protegida contra
curto-circuitos. A bomba deve ser alimentada por um transformador de isolamento ou alimentada através de um dispositivo de corrente residual (RCD) com uma corrente residual nominal de funcionamento não superior a 30 mA.
AVISO – As crianças devem ser vigiadas para assegurar que não brincam com o aparelho. Mantenha os dedos e
objectos estranhos afastados das aberturas e peças móveis.
AVISO – O motor tem de ser devidamente ligado à terra. Ligue o fio de terra ao parafuso verde de ligação à terra; para
unidades já com cabo de alimentação, utilize tomadas devidamente ligadas à terra.
AVISO – Utilize um grampo de ligação para ligar o motor a outras peças ligadas através do condutor de tamanho
adequado, conforme exigido pelos regulamentos eléctricos.
AVISO – Ao efectuar estas ligações eléctricas, consulte o diagrama fornecido sob a tampa da caixa de terminais do
motor. Certifique-se de que as ligações eléctricas estão bem apertadas e vedadas antes de ligar a alimentação de energia. Volte a instalar todas as tampas antes de colocar em funcionamento.
AVISO – Certifique-se de que a tensão eléctrica de alimentação do motor corresponde à da rede de distribuição e que
os cabos de alimentação eléctrica correspondem à potência e corrente da bomba.
AVISO – Leia e siga todas as instruções neste manual do proprietário e no equipamento. O não cumprimento das
instruções poderá causar ferimentos. Este documento deve ser fornecido ao proprietário da piscina e deve ser guardado por este último em local seguro.
AVISO – Este aparelho pode ser utilizado por crianças a partir dos 8 anos inclusive e pessoas com capacidades
físicas, sensoriais e mentais reduzidas ou pessoas com falta de experiência e conhecimento desde que instruídas/ supervisionadas e que compreendam os riscos envolvidos. As crianças não devem brincar com o aparelho. A limpeza e manutenção do aparelho não deverão ser levadas a cabo por crianças a não ser que tenham mais de 8 anos e sob supervisão. Mantenha o aparelho e o cabo afastados de crianças menores de 8 anos de idade.
AVISO – A bomba é destinado para a operação contínua, à temperatura de água máxima de 35°C.AVISO – Utilize apenas peças sobresselentes originais Hayward.AVISO – Se o cabo de alimentação estiver danificado, tem de ser substituído pelo fabricante, pelo seu agente de
assistência ou por pessoas com qualificações semelhantes, no sentido de evitar quaisquer perigos.
AVISO – Para desligar da alimentação eléctrica principal, tem de ser incorporado um interruptor externo com uma
separação de contactos em todos os pólos que permita um corte total em condições da categoria de sobretensão III na instalação eléctrica fixa, de acordo com as regras de instalação eléctrica.
AVISO – Não utilize a bomba da piscina se o cabo de alimentação ou o cárter da caixa de ligação do motor estiverem
danificados. Fazê-lo pode resultar em choque eléctrico. Se o cabo de alimentação ou o cárter de ligação do motor estiverem danificados, têm de ser imediatamente substituídos por um agente de assistência ou por uma pessoa com qualificações semelhantes, no sentido de evitar quaisquer perigos.
AVISO – Este motor de piscina NÃO está munido de um sistema de anulação de vácuo de segurança (SVRS). O
SVRS ajuda a evitar situações de afogamento devido ao aprisionamento do corpo em drenos subaquáticos. Em algumas configurações de piscinas, se o corpo de uma pessoa tapar o dreno, essa pessoa pode ficar aprisionada devido ao efeito de aspiração. Em função da configuração da sua piscina, pode ser necessário um SVRS para suprir os requisitos locais.
UTILIZE APENAS COMPONENTES DE SUBSTITUIÇÃO GENUÍNOS HAYWARD
Página 2 de 6 Bomba Rev. I
Loading...
+ 47 hidden pages