Hayward LTBCY11300 Owner's Manual

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Low Voltage Pool
Transformer
for ColorLogic® and CrystaLogicTM Pool/Spa Lights
Owner’s Manual
Contents
Introduction....................3
Installation.....................4
Warranty........................9
Hayward Pool Products Canada
2880 Plymouth Drive, Oakville ON L6H 5R4
Haywardpool.ca
092498HC RevA
Basic safety precautions should always be followed, including the following: Failure to follow instructions can cause severe injury and/or death. This is the safety-alert symbol. When you see this symbol on your equipment or in this manual, look for one of the following signal words and be alert to the potential for personal injury. WARNING warns about hazards that could cause serious personal injury, death or major property damage and if ignored presents a potential hazard. CAUTION warns about hazards that will or can cause minor or moderate personal injury and/or property damage and if ignored presents a potential hazard. It can also make consumers aware of actions that are unpredictable and unsafe. The NOTICE label indicates special instructions that are important but not related to hazards.
LTBCY11300
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
2
IMPORTANT SAFETY INSTRUCTIONS
Before installing or servicing this electrical equipment, turn power supply OFF. READ AND FOLLOW ALL INSTRUCTIONS
WARNING – Read and follow all instructions in this owner’s manual and on the equipment. Failure to follow instructions can cause se­vere injury and/or death.
WARNING – This product should be installed and serviced only by a qualied professional.
CAUTION – All electrical wiring MUST be in conformance with all ap­plicable local codes, regulations, and the National Electrical Code (NEC).
ATTENTION INSTALLER – THIS MANUAL CONTAINS IMPORTANT INFOR­MATION ABOUT THE INSTALLATION, OPERATION, AND SAFE USE OF THIS PRODUCT THAT MUST BE FURNISHED TO THE END USER OF THIS PRODUCT. FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS COULD RESULT IN SERIOUS INJURY.
WARNING – Risk of Electric Shock. All electrical wiring MUST be in conformance with all applicable local codes, regulations, and the National Electrical Code (NEC). Hazardous voltage can shock, burn, and cause death or serious property damage. To reduce the risk of electric shock, do NOT use an extension cord to connect unit to elec­tric supply.
WARNING – An equipment grounding terminal is provided in the eld wiring compartment. To reduce the risk of electric shock, this termi­nal must be connected to the grounding means provided in the elec­tric supply panel with a conductor equivalent in size to the circuit conductors supplying this equipment.
IMPORTANT - Reference NEC codes for all wiring standards including, but not limited to, grounding, bonding and other general wiring pro­cedures.
WARNING – Networked ColorLogic Lights and related electrical con­nections are receiving electrical power at all times, even when the lights are OFF! Turn o power at the main breaker before servicing ColorLogic lights.
SAVE THESE INSTRUCTIONS
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
3
Introduction
The Hayward® 300 Watt Pool Transformer LTBCY11300 is a low voltage transformer for use with pool and spa lights and submersible fixtures. It can be used to power up to four Hayward Universal ColorLogic® and CrystaLogicTM LED lights and offers a dedicated mounting location for the Coupler LKBUN1000 (necessary when using a powerline networking connection from a Hayward Pro Logic® controller). The LTBCY11300 has 3 output options, 12v, 13v and 14v.
Specifications
Enclosure Size: 7 9/16” (19.2 cm) high x 5 5/8” (14.3 cm) wide x 4 5/8” (11.8 cm) deep.
Mounting brackets top and bottom.
Enclosure Type: (A) 0.054” corrosion resistant steel with electrostatically applied white coat-
ing.
Knockouts: Total of eight 1/2”-3/4” combination. (4) bottom, (2) right side, (2) left side
Electrical: Input: 120v, 60Hz, 3A max.
Output: 12, 13 or 14 Vac @ 300W max For field connections, use wires suitable for at least 90ºC (194ºF)
Circuit Protection: A “Split Bobbin” between the primary and secondary windings assures safe
operation and the built-in circuit protection will disconnect power to the transformer in case of defect or overload. This transformer is suitable for di­rect connection to underwater Pool and Spa lights when used with adapter, clamp and duct seal.
.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
4
Installation
NOTE: Lever action terminal blocks are included to aid in installation. Open the levers all the way when inserting wires. Close the levers to lock the wires in place.
Safety Installation Requirements
• For direct wiring of underwater lights, the installation must comply with provisions of the National Electric Code, ANSI/NFPA 70, including those in Article 680 - Swimming Pools, Foun­tains, and Similar Installation, or articles 68-060, 062 and 066 of the Canadian Electric Code
• The enclosure of the transformer must be provided with a fail-proof ground as required by NEC, Article 680 and any applicable local codes. For Canadian installations, the supply circuit must be protected by a ground fault circuit interrupter.
• Be sure to run the branch circuit grounding conductor to the equipment grounding conductor terminal of the panel board and that this terminal must be directly connected to the panel board enclosure.
• The transformer should be mounted at least 1 foot above the deck level with the field wiring compartment down.
• Locate the LTBCY11300 at least 10 feet (3m) away from the inside wall of the pool.
• Make sure that all unused taps (leads) are separately insulated.
• Use the included waterproof fitting and duct seal to connect the conduit from the pool/spa light to the transformer. See diagram on page 5.
• All unused openings in the LTBCY11300 must be closed with acceptable plugs.
• Install to permit access for servicing.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
5
Connecting directly to Pool/Spa Light
When the low voltage pool light will be directly connected to the LTBCY11300, use the included non-metallic conduit adaptor and duct seal. Refer to the diagram below. Any connections to the bus bar should be tightened to 10 in/lbs.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
6
Wiring to ColorLogic/CrystaLogic Lights (not networked) and other low voltage Pool or Spa Lights
For field wiring information, please refer to the instructions attached to the inside front cover of the LTBCY11300 as well as the diagram below.
TRANSFORMER
White wires connected to the below terminals
Hayward LTBCY11300 300 watt transformer
powering low voltage Pool or Spa Lights