Installers & Inspectors
FILE E39338
THIS UNIVERSAL COLORLOGICTM AND CRYSTALOGIC
TM
LUMINAIRES ARE
UL LISTED AND HAVE BEEN EVALUATED FOR USE WITH VIRTUALLY ALL
MANUFACTURER’S LUMINAIRE HOUSINGS (FORMING SHELL) ALREADY
INSTALLED IN THE FIELD.
THE UNIVERSAL COLORLOGIC/CRYSTALOGIC LUMINAIRE PLUS
UNIVERSAL COLORLOGIC NICHE FORM A COMPLETELY NONMETALLIC
LOW VOLTAGE LIGHTING SYSTEM. TOGETHER, THIS COMBINATION DOES
NOT REQUIRE BONDING OR GROUNDING WHEN POWERED BY A LISTED
POOL/SPA TRANSFORMER AND INSTALLED PER THE NATIONAL
ELECTRICAL CODE.
UNBONDED LIGHTING NEC PROVISIONS: When these UL Listed low voltage nonmetallic luminaires
are used with the Hayward nonmetallic forming shells (niches) listed below, the 2011 National Electric Code
(NEC) provides an exception to luminaire bonding and grounding in Article 680.6 and 680.23.
POOL WATER BONDING NEC PROVISIONS: For Pool Water Bonding required by Article 680.26C,
Concrete pools are considered conductive (see 680.26(B)(1)) due to the porosity of concrete and the
bonding of rebar. No Additional bonding is required. For assistance with NEC compliance questions,
contact a Hayward Senior Application Engineer at 888-898-9674. For all other product installation or usage
assistance, contact Hayward Technical Support at 888-429-9273.
The complete UL Listed ColorLogic System:
Non-conductive, 2 Wire, Sealed, 12V, nonmetallic with unbreakable lens and no
serviceable parts.
LPCUS11xxx LPCUN11xxx
LSCUS11xxx LSCUN11xxx
LPLUS11xxx LSLUS11xxx
LPWUS11xxx
Hayward non-bonded, non-grounded nonmetallic forming shells (niches) for gunite
pool and spas:
LFGUY1000 (pool) LGGUY1000 (spa)
Hayward 300 watt transformer:
LTBUY11300
Hayward 70 and 140 watt pool and spa
junction box transformer retrofit kit :
LRBUY11H65 LRBUY11P65
LRBUY11M65 LRBUY11M13
LRBUY11T65
Hayward 70 watt junction box transformer:
LTBUY11H65
Non-conductive polymer trim rings:
LNBUY1000 LNGUY1000
LNEUY1000 LNVUY1000
LNFUY1000 LQBUY1000
LQGUY1000 LQEUY1000
LQVUY1000 LQFUY1000
LFGUY1000 LGGUY1000
092500 RevA