- To prevent potential injury and to avoid unnecessary service calls, read this manual carefully and
completely.
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THIS INSTRUCTION MANUAL
Hayward Pool Products Canada
2880 Plymouth Drive, Oakville, ON L6H 5R4
Phone: 1.888.238.7665
VL Series Pump
Table of Contents
1. IMPORTANT SAFETY INSTRUCTIONS ...............................................................................................................3
2. General Information .................................................................................................................................... 6
2.1. Introduction 6
2.2. Product Dimensions 6
3. Installation and Wiring ................................................................................................................................ 6
7. Shaft Seal Change Instructions .................................................................................................................... 9
7.1. Removing the Motor Assembly 9
7.2. Removing the Impeller 9
7.3. Removing the Ceramic Seat 9
7.4. Seal Installation 9
7.5. Replacing the Impeller and Diffuser 9
7.6. Replacing the Motor Assembly 10
8. Replacement Parts ..................................................................................................................................... 11
USE OF NON-HAYWARD REPLACEMENT PARTS VOIDS WARRANTY.
ATTENTION INSTALLER - THIS MANUAL CONTAINS IMPORTANT INFORMATION ABOUT THE INSTALLATION,
OPERATION, AND SAFE USE OF THIS VARIABLE SPEED PUMP THAT MUST BE FURNISHED TO THE END USER OF
THIS PRODUCT. FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS COULD RESULT IN SERIOUS INJURY.
WARNING
CAUTION
Before installing or servicing this electrical equipment, turn power supply OFF.
Basic safety precautions should always be followed, including the following: Failure to follow instructions may
result in injury.
This is the safety-alert symbol. When you see this symbol on your pump or in this manual, look for one of the
following signal words, and be alert to the potential for personal injury.
and if ignored presents a potential hazard.
damage and if ignored presents a potential hazard. It can also make consumers aware of actions that are
unpredictable and unsafe.
The
manual and on the equipment. Failure to follow instructions can cause severe injury and/or death.
the National Electric Code (NEC).
supervise children at all times. Components such as the filtration system, pumps, and heaters must be positioned
to prevent children from using them as a means of access to the pool.
label indicates special instructions that are important but not related to hazards.
warns about hazards that could cause serious personal injury, death or major property damage
warns about hazards that
– READ AND FOLLOW ALL INSTRUCTIONS in this owner’s
– This product should be installed and serviced only by a qualified professional.
– All electrical wiring MUST be in conformance with all applicable local codes, regulations, and
– To reduce risk of injury, do not permit children to use or climb on this product. Closely
or
cause minor or moderate personal injury and/or property
with hot tubs and spas if so marked. Do NOT use with storable pools. A permanently installed pool is constructed in
or on the ground or in a building such that it cannot be readily disassembled for storage. A storable pool is
constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity.
Though this product is designed for outdoor use, it is strongly advised to protect the electrical components from the
weather. Select a well-drained area, one that will not flood when it rains. It requires free circulation of air for
cooling. Do not install in a damp or non-ventilated location. (For hot tub and spa pumps) Do not install within an
outer enclosure or beneath the skirt of a hot tub or spa.
– This pump is intended for use on permanently installed swimming pools and may also be used
Page 3 of 15
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
ISVL1285 Rev B
VL Series Pump
WARNING
WARNING
Risk of Electric Shock.
WARNING
WARNING
Risk of Electric Shock.
WARNING
Suction Entrapment Hazard.
Hair Entrapment
Limb Entrapment
Body Suction Entrapment
Evisceration/ Disembowelment
Mechanical Entrapment
inspected frequently and replaced at least every ten years, or if found to be damaged, broken, cracked, missing, or
not securely attached.
codes, regulations, and the National Electric Code (NEC). Hazardous voltage can shock, burn, and cause death or
serious property damage. To reduce the risk of electric shock, do NOT use an extension cord to connect unit to
electric supply. Provide a properly located electrical receptacle. Before working on pump or motor, turn off power
supply to the pump.
– Pool and spa components (seals, gaskets, etc.) have a finite life. All components should be
–
– (For all cord- and plug-connected units) WARNING - To reduce the risk of
All electrical wiring MUST be in conformance with applicable local
electric shock, replace damaged cord immediately.
branch circuit protected by a ground-fault circuit-interrupter (GFCI). Contact a qualified electrician if you cannot
verify that the circuit is protected by a GFCI. The unit must be connected only to a supply circuit that is protected by
a ground-fault circuit-interrupter (GFCI). Such a GFCI should be provided by the installer and should be tested on a
routine basis. To test the GFCI, push the test circuit button. The GFCI should interrupt power. Push the reset button.
Power should be restored. If the GFCI fails to operate in this manner, the GFCI is defective. If the GFCI interrupts
power to the pump without the test button being pushed, a ground current is flowing, indicating the possibility of an
electric shock. Do not use this pump. Disconnect the pump and have the problem corrected by a qualified service
representative before using.
–
In accordance with the National Electric Code (NEC), connect only to a
are damaged, broken, cracked, missing, or unsecured cause severe injury and/or death due to the following
entrapment hazards (symbols complements of APSP):
broken, cracked, missing, or not securely attached can result in a mechanical bind or swelling of the limb.
entrapment.
suction outlet sump or suction outlet cover which is damaged, broken, cracked, missing, or unsecured can result in
evisceration/disembowelment.
caught in an opening of a suction outlet cover resulting in mechanical entrapment.
–
- Hair can become entangled in suction outlet cover.
- A limb inserted into an opening of a suction outlet sump or suction outlet cover that is damaged,
- A differential pressure applied to a large portion of the body or limbs can result in an
- A negative pressure applied directly to the intestines through an unprotected
- There is potential for jewelry, swimsuits, hair decorations, fingers, toes, or knuckles to be
Suction in suction outlets and/or suction outlet covers, which
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Page 4 of 15
ISVL1285 Rev B
VL Series Pump
WARNING
WARNING
Hazardous Pressure.
WARNING
Separation Hazard.
WARNING
WARNING
Fire and burn hazard.
WARNING
SAVE THESE INSTRUCTIONS
− When outlets are small enough to be blocked by a person, a minimum of two functioning suction outlets per
pump must be installed. Suction outlets in the same plane (i.e. floor or wall), must be installed a minimum of
three feet (3’) [0.91 meter] apart, as measured from near point to near point.
− Dual suction fittings shall be placed in such locations and distances to avoid “dual blockage” by a user.
− Dual suction fittings shall not be located on seating areas or on the backrest for such seating areas.
− Never use pool or spa if any suction outlet component is damaged, broken, cracked, missing, or not securely
attached.
− Replace damaged, broken, cracked, missing, or not securely attached suction outlet components
immediately.
− In addition to two or more suction outlets per pump installed in accordance with latest APSP standards and
CPSC guidelines, follow all national, state, and local codes applicable.
− Installation of a vacuum release or vent system, which relieves entrapping suction, is recommended.
pressure during start-up, normal operation, and after pump shut-off. Stand clear of circulation system equipment
during pump start-up. Failure to follow safety and operation instructions could result in violent separation of the
pump housing and cover due to pressure in the system, which could cause property damage, severe personal injury,
or death. Before servicing pool and spa water circulation system, all system and pump controls must be in off
position and filter manual air relief valve must be in open position. Before starting pump, all system valves must be
set in a position to allow system water to return back to the pool. Do not change filter control valve position while
pump is running. Before starting pump, fully open filter manual air relief valve. Do not close filter manual air relief
valve until a steady stream of water (not air or air and water mix) is discharged from the valve. All suction and
discharge valves MUST be OPEN when starting the circulation system. Failure to do so could result in severe
personal injury and/or property damage.
– To Reduce the risk of Entrapment Hazards:
–
Pool and spa water circulation systems operate under hazardous
separation of pump components. Strainer cover must be properly secured to pump housing with strainer cover lock
ring. Before servicing pool and spa circulation system, all system and pump controls must be in off position and
filter manual air relief valve must be in open position. Do not operate pool and spa circulation system if a system
component is not assembled properly, damaged, or missing. Do not operate pool and spa circulation system unless
filter manual air relief valve body is in locked position in filter upper body. All suction and discharge valves MUST be
OPEN when starting the circulation system. Failure to do so could result in severe personal injury and/or property
damage.
isolated from any flammable structures or foreign debris they can cause fires, which may cause severe personal
injury or death. It is also necessary to allow the motor to cool for at least 20 minutes prior to maintenance to
minimize the risk for burns.
–
– Never operate the circulation system at more than 50 PSI maximum.
–
– Failure to install according to defined instructions may result in severe personal injury or death.
Failure to follow safety and operation instructions could result in violent
Motors operate at high temperatures and if they are not properly
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS