The Hayward Power-Flo® Matrix™ Pump Series is specifically engineered for the demanding requirements of today’s above­ground swimming pools. The advanced design reduces maintenance requirements while providing superior performance.
To prevent potential injury and to avoid unnecessary service calls, read this manual carefully and completely.
CAUTION We highly recommend a qualified professional install and service this product.
WARNING This manual contains important safety information that must be furnished to the end
user of this product. FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS COULD RESULT IN SERIOUS INJURY.
*Only units equipped with 3' twist-lock cords are UL-listed.
Pump Series
SAVE THIS INSTRUCTION MANUAL
HAYWARD POOL PRODUCTS, INC.
Corporate Headquarters: U.S.A: 620 Division Street 1 Hayward Industrial Drive 2935 Sidco Drive 2875 Pomona Blvd. Elizabeth, NJ 07207 Clemmons, NC 27012 Nashville, TN 37204 Pomona, CA 91768
Canada: Europe: 2880 Plymouth Drive P.I. Plaine de l'ain
01150 St Vulbas France
Oakville, Ontario L6H 5R4 Allêe des chênes
(
)
Power-Flo Matrix™ Pump Series ____________________
PRODUCT REGISTRATION
DATE OF INSTALLATION ____________________
INITIAL PRESSURE GAUGE READING (CLEAN FILTER) _______________________
PUMP MODEL ________________ HORSEPOWER _______________________
FILTER MODEL ________________ SERIAL NUMBER _______________________
Retain For Your Records
IMPORTANT SAFETY INSTRUCTIONS
When installing and using this electrical equipment, basic safety precautions should always be
followed, including the following: Failure to follow instructions may result in injury.
READ AND FOLLOW ALL INSTRUCTIONS
IN THIS OWNER’S MANUAL AND ON
EQUIPMENT.
KEEP SAFETY LABELS IN GOOD CONDITION AND
REPLACE IF MISSING OR DAMAGED.
WARNINGTo reduce risk of injury, do not permit children to use or climb on this
product. The ANSI/NSPI 4 Standard (above-ground and on-ground pools) advises that components such as the filtration system, pumps, and heaters be positioned to prevent their being used as a means of access to the pool by young children. Closely supervise children at all times.
CAUTIONThe Power-Flo Matrix™ Pump Series is intended for use on permanently
installed above-ground swimming pools and may also be used with hot tubs and spas if so marked. Do NOT use with storable pools. A permanently installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage. A storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity.
Though this product is designed for outdoor use, it is strongly advised to protect the electrical components from the weather. Select a well-drained area, one that will not flood when it rains. It requires free circulation of air for cooling. Do not install in a damp or non-ventilated location.
Bond motor to pool structure. Use a solid copper conductor, size or larger. Run wire from external bonding lug to reinforcing rod or mesh. Connect a No. 8 AWG (8.4 mm²) solid copper bonding wire to the pressure wire connector provided on the motor housing and to all metal parts of swimming pool, spa, or hot tub, and to all electrical equipment, metal piping or conduit within 5 ft. (1.5 m) of inside walls of swimming pool, spa, or hot tub. (In Canada use No. 6 AWG bonding wire.)
Power-Flo Matrix™ Pump Series __________ ________________________
NOTE: The National Electrical Code (NEC) permits use of a cord with a maximum 3 ft. (1 m) length. If your pump is equipped with a cord complying with the NEC, the following three (3) items apply.
WARNING Risk of Electric Shock. Connect only to a grounding
type receptacle protected by a Ground Fault Circuit Interrupter (GFCI). Contact a qualified electrician if you cannot verify that the receptacle is protected by a GFCI.
WARNING To reduce the risk of electric shock replace damaged cord
immediately. Do NOT bury cord. Locate cord to minimize abuse from lawn
mowers, hedge trimmers and other equipment.
WARNINGTo reduce the risk of electric shock, do NOT use an extension cord to
connect unit to electric supply. Provide a properly located outlet. Qualified personnel MUST do all electrical wiring.
CAUTIONAll suction and discharge valves MUST be OPEN when
starting the filter system. Failure to do so could result in severe personal injury and/or property damage. All drains and suction covers MUST have properly installed covers securely attached with the screws supplied with the covers. If screws are lost, order replacement parts from your supplier.
DANGERSuction Entrapment Hazard. Never use the pool or
spa if a drain cover is damaged, cracked, missing, or not securely attached. Suction in drains and suction outlets can cause drowning, disembowelment, hair or body entrapment, severe injury, and death. Disembowelment, entrapment, or drowning is possible when body parts or hair come in contact with damaged, broken, cracked, missing, or unsecured drain covers and suction outlets. Suction from pumps with only one drain or suction outlet can cause disembowelment, entrapment, or drowning. Pumps for pools and spas require two (2) functioning suction outlets at least three (3) feet apart, on two (2) walls or on the floor and one (1) wall of the pool or spa. Installation of pump and suction outlets must be in compliance with all applicable local building codes. Replace damaged, broken, cracked, missing, or unsecured drain covers and suction outlets immediately.
WARNINGHazardous Pressure. Pumps, filters, and other
equipment/components of a swimming pool filtration system operate under pressure. Incorrectly installed and/or improperly tested filtration equipment and/or components may fail resulting in injury and/or property damage. A qualified pool professional MUST conduct all pressure tests. This product is intended for above-ground/on-ground swimming pool applications only. Do NOT connect to a high-pressure system such as a municipal water main. To prevent explosion caused by entrapped air in the filtration system use provided air relief valve to bleed air from the system. Confirm that ALL filtration system component clamps, bolts, and covers have been tightened to the manufacturer’s recommendations.
WARNINGNever operate or test the filtration system at more than 30 PSI.
SAVE THESE INSTRUCTIONS
Power-Flo Matrix™ Pump Series ____________________
Product Specifications
Dimensions
General Information
Introduction
This manual contains information for the proper installation and operation of the Hayward Power-Flo Matrix™ pump. The instructions in this manual MUST be followed precisely.
Product Features
The Above-ground industry’s largest above-ground strainer basket for large debris collection with minimal
maintenance.
Horizontal/Vertical Discharge Feature – Simply converts from horizontal to vertical discharge orientation
with the press of a button.
Quick connect intake and discharge pipe connection. ‘C’ clip connector allows for easy disengagement of strainer housing in a matter of seconds for hassle-free
maintenance.
Heavy duty, high performance motor with integrated automatic thermal overload protector for years of
operation.
High quality Noryl Durable, corrosion-proof housing for years of dependable service and all-weather performance. Heat resistant, double-sized seal for long, lasting efficiency. Energy-efficient, protected rear-mounted switch. Integral drain plug for easy winterization of pump
®
impeller with wide openings to prevent clogging by leaves and large debris.
Installation Instructions
Pump Location
For best pump performance, locate the system below the pool water line.