Hayward Saline C®, 6.0, HCSC60 Owner's Manual

TM
Saline C 6.0
Commercial Salt Chlorine Generator
Owner’s Manual
ISHCSC60 RevE
Contents
Description.....................3
Installation.....................4
Operation........................7
Maintenance...................8
Parts Guide.....................9
Warranty........................11
Conforms to UL 1081 and
E
T
N
I
C
L
I
S
3101970
CSA, C22.2 #218.1
IMPORTANT SAFETY INSTRUCTIONS
Basic safety precautions should always be followed, including the following: Failure to follow instructions can cause severe injury and/or death.
This is the safety-alert symbol. When you see this symbol on your equipment or in this manual, look for one of the following signal words and be alert to the potential for personal injury.
WARNING warns about hazards that could cause serious personal injury, death or major property dam­age and if ignored presents a potential hazard.
CAUTION warns about hazards that will or can cause minor or moderate personal injury and/or property damage and if ignored presents a potential hazard. It can also make consumers aware of actions that are unpredictable and unsafe.
R
T
E
K
C
CM
US
D
E
T
The NOTICE label indicates special instructions that are important but not related to hazards.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTSUSE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Hayward Commercial Pool Products
10101 Molecular Drive, Suite 200
Rockville, MD 20850
Phone: (800) 657-2287
www.haywardcommercialpool.com
IMPORTANT SAFETY INSTRUCTIONS
WARNING Read, understand, and follow all safety and operation instructions.
Failure to follow safety and operation instructions can result in severe personal injury or death.
WARNING -Risk of Electric Shock. Hazardous voltage can, shock, burn and cause death or serious prop­erty damage. To reduce the risk of electrical shock, connect the equipment assembly to a circuit protected by a ground-fault circuit-interrupter. Do not bury cord. If cord is damaged, replace immediately.
WARNING – When installing the system, ensure that power is interlocked with the main recirculation pump power source for the pool/spa to ensure that the Saline C 6.0 system cannot operate when the pumps are off.
WARNING Chemical Hazard. Chemicals can cause burns both internally and externally. To avoid death, serious injury or property damage: Wear eye and skin protection while maintaining or servicing this unit. Do not inhale fumes from the unit.
CAUTION To reduce risk of injury, do not permit children to use or climb on this product. Closely supervise children at all times. The ANSI/NSPI-4 Standard (above-ground and on-ground pools) advises that components such as the this system, filtration system, pumps, and heaters be positioned to prevent their being used as a means of access to the pool by young children.
WARNINGHazardous Pressure. Pool and spa water circulation systems operate under hazardous pres­sure during start up, normal operation, and after pump shut off. Stand clear of circulation system equipment dur­ing pump start up. Failure to follow safety and operation instructions could result in violent separation of the pump housing and cover, and/or filter housing and clamp due to pressure in the system, which could cause property damage, severe personal injury, or death. Before servicing pool and spa water circulation system, all system and pump controls must be in off position and filter manual air relief valve must be in open position. Before starting system pump, all system valves must be set in a position to allow system water to return back to the pool. Do not change filter control valve position while system pump is running. Before starting system pump, fully open filter manual air relief valve. Do not close filter manual air relief valve until a steady stream of water (not air or air and water) is discharged.
Notice: This product should be installed and serviced only by a qualified pool professional.
SAVE THESE INSTRUCTIONS
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
DESCRIPTION
General Information
The Saline C 6.0 is a saline chlorination system designed for commercial swimming pool applications. The Saline C 6.0 is certified to produce 5 pounds of equivalent chlorine per day (based on 3500 ppm of salt). The system produces chlorine continuously from a salt concentration of 3500 ppm to 5000 ppm added to the pool. The Saline C 6.0 is designed for commercial service and can be operated 24 hours a day and/or controlled by any pool controller. All models are reverse polarity for self cleaning and reduced cell maintenance.
Electrolytic Cell Assembly
The electrolytic cell assembly consists of a clear cell vessel containing an electrolytic cell made from precious metal coated cell plates. Pool water from the pool circulation system is directed through the cell. The pool water, maintained between 3500 and 5000 ppm salt concentration is converted in the electrolytic cell to free chlorine. The free chlorine is then circulated to the pool and combines with organics and further combines to form salt to be used again by the electrolytic cell. This is called a closed loop system because the salt is used repeatedly and is only lost through splash-out, backwashing, leaks and rainfall.
Power Supply and Control Box
The power supply provides the current to the electrolytic cells to produce the rated amount of sodium hypochlorite. The power supply houses all the safety features to prevent system operation in the event of a malfunction.
General Specifications
Model
Designation
Saline C 6.0 HCSC60 5.0lbs/day@ 3500 ppm 36 50 psi 40 gpm 100 gpm 2 inch 2 inch
Part
Number
Sodium Hypochlorite
Production (lbs/day)
Rated Power
in DC Amps
Rated
Pressure
Minimum Water Flow Rate (gpm)
Maximum Water Flow Rate (gpm)
Inlet
Diameter
(Inches)
Outlet
Diameter
(Inches)
Electrical Requirements
Model
Designation
Saline C 6.0 HCSC60 120 1 60Hz 6.5 15
Part
Number
Voltage
(supply AC)
Phases Frequency Amps GFCI
Breaker
Sizing Guidelines
Chlorinator sizing must comply with local codes. Please contact your local health department for specific requirements or contact your local Hayward representative for assistance.
Head Loss Data (ft of H2O)
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
3
INSTALLATION
Power
Blue Control
Cell
Unpacking
Units are shipped from the factory. In the event of damage during shipping, it is the responsibility of the customer to notify the carrier immediately and to file a damage claim. Open the crate or packaging carefully and examine all material inside.
Storage
When storing units, use the original packaging and store under a shelter to protect the contents from weather.
Plan Ahead
Almost every pump room encountered is different. It is imperative to have prior knowledge of the facility in which the unit is to be installed and to evaluate what type of tools, wall anchors, etc. will be needed to make the installation as problem free as possible.
The power supply must be mounted within 5 feet of the cell housing so the DC cables to the top of the electrolytic cell will reach. Also, any pool controller must be within 5 feet of the power supply so the control cord will reach.
Power Supply Installation
The Saline C 6.0 system comes with 4 rubber feet on the bottom of the power supply and 4 keyhole mounting holes on the back of the power supply. The power supply can sit on a shelf or similar structure without any mounting or the system can be mounted on to a wall.
CAUTION To reduce the risk of injury - Never try to support the weight of the power supply using only drywall anchors. The power supply must have
a stud for support!
Locate a space on the wall, in the pump room, that will accommodate the dimensions of the power supply. The two top keyhole mounting holes are 11-1/4 inches apart. Install screws and hang the power supply.
System Wiring
WARNING - Risk of Electric Shock. Hazardous voltage can shock, burn and cause death or serious property damage. To reduce the risk of electrical shock, turn off all power to the system.
CAUTION Chemical Hazard - Chemicals can cause internal
and external burns, causing death, serious injury or property dam­age, to avoid: all systems must be wired so that when the pool circulation pump is off, the power to the Saline C 6.0 is off. Consult a Certified Electrician for the best wiring method to achieve this.
All Saline C 6.0 systems ship from the factory with a 3 foot black power cord and a 6 foot blue control cord.
Plug the power cord into a minimum 15 amp wall outlet protected by a ground fault circuit interrupter. Connect the blue control cord to a chemical feed controller or for continuous operation with- out the use of a chemical feed controller, plug the blue control cord into a 15 amp wall outlet protected by a ground fault circuit in­terrupter. This outlet must be interlocked with the circulation pump of the pool so that if the pump is turned off, power to the Saline C
6.0 is disconnected and the system is unable to operate.
Cord
Cord
Cables
4
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS