SUPER STAR-CLEAR SPECIFICATIONS
MODEL
NO.
C2000 C3000 C4000 C5000
EFFECTIVE
FILTRATION
AREA
2
200 300 400 500
M
2
19 28 37 47
DESIGN FLOW RATE
GPM
75 112 150 150
LPM
284 424 568 568
GPM
75 112 150 150
LPM
284 424 568 568
RESIDENTIAL PUBLIC
PRESSURE LOSS AT DESIGN FLOW RATE
RESIDENTIAL PUBLIC
PSI
2.1
5.1
6.8
6.8
BAR
0.15
0.36
0.47
0.47
PSI
2.1
5.1
6.8
6.8
BAR
0.15
0.36
0.47
0.47
MAXIMUM WORKING
PRESSURE
BAR
3.45
3.45
3.45
3.45
PSI
50 50 50 50
REQUIRED CLEARANCE
SIDE ABOVE
IN 18 18 18 18
CM
46 46 46 46
IN 18 18 18 22
CM
46 46 46 56
PARTS
Super Star-Clear
Models C2000, C3000, C4000, C5000
REF.
NO.
1 2
--­3
4a 4b 4c 4d
5
6a 6b 6c 6d
7
8a 8b 8c
9
10
11 12a 12b 12c 12d
13 14a 14b 14c 14d
15
16
17
18
19
20
21
22
NO.
REQ’D.
1 1 1 1 1 1 1 1 1 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 4 4 4 4 1 1 1 2 2 2 2 2
MODEL
NUMBER
ECX270861 DEX2400S DEX2400Z3A SX200Z5 DEX2400BT DEX3600BT DEX4800BT DEX6000BT DEX2400J DEX2400J4 DEX2400JS DEX2400J3 DEX2400JN DEX2400K CX2000DA CX3000DA CX5000DA CX3000F1B CX3000FB DEX360M CX800Z4 CX3000Z3 CX4000Z3 CX5000Z3 CX3000J CX470XRE CX570XRE CX870XRE CX1260RE CX3000C DEX2400A1T SPX1022C SX360Z1 DEX360FB SX200Z4 SX240F SX200R
DESCRIPTION
Pressure Gauge Relief Valve/Gauge Adapter Assy. O-Ring for Relief Valve Stem (Set 3) Relief Valve Assembly O-Ring Filter Head (C2000) Filter Head (C3000) Filter head (C4000) Filter Head (C5000) Clamp Assembly Washer w/Small Hole Spring Washer w/Large Hole Brass Sleeve Nut Filter Tank O-Ring Top Closure Plate (C2000) Top Closure Plate (C3000, C4000) Top Closure Plate (C5000) Inlet Elbow Outlet Elbow O-Ring Air Relief Tube Air Relief Tube Air Relief Tube Air Relief Tube Air Tube Screen Cartridge Element (C2000) Cartridge Element (C3000) Cartridge Element (C4000) Cartridge Element (C5000) Bottom Collector Manifold Filter Body 1-1/2Drain Plug w/O-Ring O-Ring Bulkhead Fitting O-Ring 1-1/2SKT. x 2” SLIP Connector Locknut
PUMP SELECTION AND LOCA TION
To power your filter, select a continuous duty pump designed for swimming pool or spa service.
It is important to first determine where your pump and filter will be located. If above the water line, a self-priming pump must be used. Self-priming pumps (
such as Hayward Super Pump®,
Super II™ or Max-Flo™
) have the ability to lift water from a
lower level and prime automatically. Select a pump with an average output range suitable for the filter's
capacity. Other considerations are operation of hydrotherapy fittings, automatic cleaners, etc. Your dealer will help you select the proper size pump for your system.
FILTER LOCATION
Since plumbing fittings offer a resistance to water flow, position the filter as close to the swimming pool as practical. Keep the number of fittings to a minimum. Select a well-drained area, one that will not flood when it rains.
The filter should be placed on a
level
concrete slab, very firm ground, or equivalent, as recommended by your pool dealer. Allow a top clearance for cartridge removal of 18 (457 mm) for C2000, C3000 and C4000, 22(559 mm) for C5000. Be sure filter, pump, drain and pressure gauge are accessible for convenient operation.
Position filter so the tank can drain by gravity. If practical, place pump and filter in the shade to shield it
from continuous, direct heat from the sun.
PLUMBING
Use 1-1/2or 2piping. Connections are 1-1/2” socket (solvent weld) or 2male slip. We suggest unions be provided for easy servicing.
Refer to the diagram for typical installation. Ball valves are recommended where needed. While all systems vary, the main consideration is to provide the desired control of water flow from the pool to the pump and filter and back to the pool. When the filter is located below the water level, provide valves to prevent back flow of water to the filter during cleaning and routine servicing.
Connect the pool suction plumbing between the skimmer, pool outlet, etc., and the pump.
Install the pool return plumbing. If pressure gauge is not installed, apply Teflon tape to the
gauge threads, and
carefully
screw the gauge into the
gauge adapter assembly. A filter drain plug is furnished with each filter and is all that
is needed for complete filter draining. A manual air vent valve is furnished to aid in bleeding off unwanted air when starting the filter. The auto air relief provides air removal during operation.
All electrical connections should be made in accordance with local codes.
Check for joint leaks before operating. Refer to pump instruction booklet for pump information.
NOTE: ANSI/NSPI-4 Article V, standard for above-ground and on-ground pools, advises that components such as the filtration system, pumps and heater be positioned so as to prevent their being used as a means of access to the pool by young children.
BEFORE STARTING THE FILTER
Superchlorinate the pool water by adding unstabilized granular or liquid chlorine. Stabilized forms of chlorine are recommended for normal daily use after the initial clean up of the water. Follow chemical manufacturer’s recommendations for superchlorination and daily use.
ISC2000-98
1.
2.
3.
4.
1.
2.
3.
4.
5.
6.
7.
8.
9.
OWNER’S GUIDE
MODELS C2000, C3000, C4000, C5000
Hayward Super Star-Clear filters are high performance swimming pool filters with filtration ratings to 9000 gallons (34 KL) per hour. Manufactured from durable, corrosion-proof materials, they are designed for continuous or intermittent operation, for installation above or below the pool water line, for fresh or salt water swimming pools or spas. Star-Clear filters utilize multiple reusable, reinforced polyester filter cartridge elements to provide a high degree of water clarity and long filter cycles with absolute minimum care.
31-3/4
(807 mm)
36-1/2
(927 mm)
42-1/2
(1080 mm)
48-1/2
(1232 mm)
C2000
C3000
C4000
C5000
Loading...
+ 2 hidden pages