INSTALLATION, OPERATION 
& 
MAINTENANCE INSTRUCTIONS
NO. OOO2076521 (0
1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 
E-mail: haws@hawsco.com  website: www.hawsco.com 
NOTE TO INSTALLER: Please leave this information with the Maintenance Department. 
HAWS® warrants that all of its products are guaranteed against defective material or poor 
workmanship for a period of one year from date of shipment. HAWS liability under this 
warranty shall be discharged by furnishing without charge F.O.B. HAWS Factory any 
goods, or part thereof, which shall appear to the Company upon inspection to be of 
defective material or not of first class workmanship, provided that claim is made in writing 
to company within a reasonable period after receipt of the product. Where claims for 
defects are made, the defective part or parts shall be delivered to the Company, prepaid, 
for inspection. HAWS will not be liable for the cost of repairs, alterations or replacements, 
or for any expense connected therewith made by the owner or his agents, except upon 
written authority from HAWS, Sparks, Nevada. HAWS will not be liable for any damages 
caused by defective materials or poor workmanship, except for replacements, as provided 
above. Buyer agrees that Haws has made no other warranties either expressed or implied 
in addition to those above stated, except that of title with respect to any of the products or 
equipment sold hereunder and that HAWS shall not be liable for general, special, or 
consequential damages claimed to arise under the contract of sale. 
The emergency equipment manufactured by HAWS is warranted to function if installation 
and maintenance instructions provided are adhered to. The units also must be used for 
the purpose, which they were intended. This product is intended to supplement first-aid 
treatment. Due to widely varying conditions HAWS cannot guarantee that the use of this 
emergency equipment will prevent serious injury or the aggravation of existing or prior 
injuries. 
NO OTHER WARRANTIES EXPRESSED OR IMPLIED ARE AUTHORIZED, 
PROVIDED OR GIVEN BY HAWS.
SHOULD YOU EXPERIENCE DIFFICULTY WITH THE INSTALLATION OF THIS 
MODEL, PLEASE CALL: 
FOR PARTS CALL:  
 (U.S.A. AND CANADA ONLY) MONDAY-THURSDAY: 6:00 A.M. – 4:00 P.M. PST 
Model VRKHO1 
 24 VAC SENSOR
LIMITED WARRANTY 
1-800-766-5612 
1-800-758-9378  
FRIDAY: 6:00 A.M – 1:00 P.M. PST 
No. 2080407(1) 
10/09   Model VRKHO1  Page 1 of 4 
 

Recommended Tools: 5/64” Hex Key wrench, 11/32” socket wrench or open end wrench. 
INSTALLATION PROCEDURE 
Step 1: Remove grille, shut off water supply and unplug 24VAC transformer from duplex receptacle. 
Step 2: Remove bottom plate from fountain using 5/64” Hex key wrench. 
Step 3: Remove sensor to be replaced using 11/32” socket wrench and disconnect leads to sensor. 
** With older style 24VAC H.O. sensor, unplug sensor from cable assembly. Snip off the 3 
position connect from cable assembly and tape off or, with a wire nut, insulate the white wire 
Step 4: Connect leads from cable assembly to sensor. Black lead to “24VAC IN” and red lead to “TO 
Step 5: Install sensor. 
Step 6: Plug the 24VAC transformer into the duplex receptacle. This will initiate the sensor’s “start-up 
  NOTE: 
Step 7: Turn water supply on and adjust the bubbler’s flow using the black regulator mounted next to 
Step 8: Re-install bottom plate and grille. 
(this wire, neutral, is not required with new style sensor.) 
VALVE”. 
mode”. “Start-up mode” for the H.O. sensor will take approximately five (5) minutes to 
complete its full cycle of self-calibration. It is important that no object is in front of sensor 
during this time. A steady red light visible in the center of the sensor window indicates the 
sensor is in “start-up mode”. If the red light is flashing, this indicates that the sensor is picking 
up an object. Unless this object is a permanent fixture, (i.e. a wall, a plant, etc.), it must be 
removed from the view of the sensor. The sensor will adapt itself around such permanent 
fixtures. In this mode, the sensor will take up to ten (10) minutes to calibrate. 
1. If the 24VAC power supply is interrupted for more than fifteen (15) seconds, the “start-up 
mode” will automatically repeat itself when power is restored. 
2. If the indicator light flashes three (3) times quickly, then three (3) times slowly and 
continues to repeat this sequence, this indicates incorrect wiring or a short in the 24VAC 
power supply. 
3. When someone remains standing in front of the sensor for more than thirty (30) seconds, 
the sensor will automatically shut off the water supply to the bubbler. To restart, stand to 
the side for a moment, then return to a position in front of the sensor. 
the solenoid valve. Finally, check fountain for leaks. Verify the chiller turns off after water 
reaches proper temperature. If there are any problems, refer to sensor’s Troubleshooting 
Guide. 
10/09     Model VRKHO1  Page 2 of 4   
 

SENSOR TROUBLESHOOTING GUIDE 
Step 1: A loud click indicates when the solenoid valve is turned on. If valve clicks, but no water 
comes on make sure screwdriver stop is wide open (turn counterclockwise). If valve clicks 
but still no water, check valve or line for obstruction. If valve does not click when hand is 
placed a few inches in front of sensor, go on to next step. DO NOT ATTEMPT TO 
DISASSEMBLE SENSOR, DAMAGE WILL RESULT.
Step 2: Using volt meter, check for 24VAC across the transformer terminals. Replace transformer if 
faulty. 
Step 3: Check solenoid valve. Voltage rating on valve top plate should be 24VAC. Unplug sensor 
from wiring harness. Using a volt meter, check for 24VAC signal from wiring harness (use 
hand in front of sensor to activate). 
  Valve coil may be checked for continuity using an Ohm meter. Disconnect valve from wiring 
harness and sensor wires. Connect each valve lead to a meter lead. One meter lead should 
be plugged into meter ground socket and one should be plugged into socket marked “Ohm”. 
Coil resistance should be around 10 – 20 Ohms. If resistance is near infinity or zero, solenoid 
coil is at fault. Coils may be easily replaced without disconnecting valve body from plumbing. 
Replace with new 24VAC rated coil. 
Step 4: Check wiring harness. If wiring harness appears to be hooked up correctly, disconnect 
harness from valve, sensor and power cord, then check harness for continuity using Ohm 
meter. Resistance between connectors attached to each other by wires should be near zero 
Ohms. High resistance indicates a faulty connector or wire. There should be infinite 
resistance between separate (independent) legs of the wiring harness. Less than infinite 
resistance indicates a short or cross connection. If wiring harness has proper continuity and 
is hooked up properly, proceed to Step 5. 
Step 5: Check sensor. If Steps 2, 3 and 4 all check out OK, the sensor is probably the problem. The 
sensor acts pretty much like a simple relay or switch. The SCR (semiconductor relay) within 
the sensor will not fully switch without a 6 to 11 Watt load such as a solenoid valve or 
household light bulb. For this reason, a simple Ohm meter test on a good sensor which is not 
connected to the proper load will yield misleading results seemingly indicating improper 
function. 
© 2009 Haws® Corporation – All Rights Reserved 
HAWS
10/09   Model VRKHO1  Page 3 of 4 
® 
and other trademarks used in these materials are the exclusive property of Haws Corporation.