![](/html/86/86f4/86f4674c06502d7e730d51693541a2dab050d72ffca011971d32d2cc8d16d920/bg1.png)
THIS DOCUM EN T IS TR UE AND CORRECT AT TIME OF PUBL ICATION. CO NT INUED PRODUCT IMPR O V EMENTS
MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE.
FROST LINE
18"
457mm
TO FROST LINE
4 1/2" MIN
114mm
36"
914mm
3/8" SUPPLY TUBING
ACTUATION TUBING
(TO PUSH BUTTON)
BREAT H ER TUBING
(TO ATMOSPHERE ABOVE GROUND)
MIN.
SECURE 1" CLAMP
AROUND 1/2" ELBOW
(DO NOT OVERTIGHTEN)
RIGID 1/2" I PS FIT TING S
(SUPPLY HOSE ASS'Y SUPPLIED)
(UNION N O T SUPPLIE D)
VALVE BOX (NOT SUPPLIED)
SIZE: 12-1/4" H X 19" W X 25-1/2" L
(311mm H X 482mm W X 648mm L)
REMOVABLE CAP
8-1/2"
216mm
36"
INSULATION
(NOT SU PPLIED)
PVC "Y" ASSEMBLY
914mm
TO
67"
1702mm
FOAM INSULATION
PVC PIPE, TRIM TO
DESIRED LENGTH.
5867 PRESSURE REGULATOR (SEE NOTE 1)
CHECK VA L VE
(VALVE ASS'Y)
LIFT ROD WITH SUPPLIED 1" CLAMP
(USE TO LOW ER/RAISE VALVE ASSEMBLY)
MIN.
MAX.
C
2016
Haws Corporation - All Rights Reserved.
MINIMUM 5 CUBIC FEET POROUS
GRAVEL F ILL (NOT SU PPLIED)
F.D.A . AND N SF APPROV ED
HIGH PRESSURE HOSE.
HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation.
R
1/2" IPS SUPPLY FROM
SHUTOFF (NOT SUPPLIED).
ECN:
5137
DATE:
09/22/92
DATE:
BY:ECN NO.
CHK'D.:
10/24/16
CC
VWC
MODEL(S)
SCALE:
DRAWN:
CJL
APPROVED:
FV
REVISED PER
(775) 359-4712 FAX (775) 359-7424
E-MAIL: HAWS@HAWSCO.COM
WEBSITE: WWW.H AWSCO.COM
6518.2FR
VALVE , FREEZE RESISTANT, DUAL
DRAWING TYPE: SIZE: A
1:13
INSTALLATION
1455 KLEPPE LANE
SPARKS, NEVADA 89431
PART NUMBER
0002077791.D
REVISION
SHEET OF
21
13
![](/html/86/86f4/86f4674c06502d7e730d51693541a2dab050d72ffca011971d32d2cc8d16d920/bg2.png)
THIS DOCUM EN T IS TR UE AND CORRECT AT TIME OF PUBL ICATION. CO NT INUED PRODUCT IMPR O V EMENTS
MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE.
84"
2134mm
OPENING
DIA.
24"
610mm
4"
102mm
MIN.
25"
635mm
±4" [102mm]
90°
1-1/4" IPS
WASTE
(NOT SUPPLIED)
FROST LINE
5"
127mm
MIN.
90°
90°
FINISHED GRADE
1/2" IPS SUPPLY
(NOT SUPPLIED)
12"
305mm
MIN.
REQUIRED DEPTH BELOW
FROST LINE. (REFER TO
INSTALLATION INSTRUCTIONS ).
25"
635mm
MIN.
BELOW FROST LINE
12"
305mm
C
2016
Haws Corporation - All Rights Reserved.
MIN.
MINIMUM 5 CUBIC FEET POROUS
GRAVEL FILL (NOT SUPPLIED)
50"
1270mm
(AT BASE)
HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation.
R
DIA.
DRAWN:
CJL
APPROVED:
FV
REVISED PER
ECN:
5137
DATE:
09/22/92
DATE:
10/24/16
BY:ECN NO.
CC
CHK'D.:
VWC
MODEL(S)
6518.2FR
VALVE , FREEZE RESISTANT, DUAL
DRAWING TYPE: SIZE: A
1:24
SCALE:
1455 KLEPPE LANE
SPARKS, NEVADA 89431
(775) 359-4712 FAX (775) 359-7424
E-MAIL: HAWS@HAWSCO.COM
WEBSITE: WWW.H AWSCO.COM
INSTALLATION
PART NUMBER
0002077791.D
REVISION
21
SHEET OF
23