Haws 3202, 3202G Installation, Operation & Maintenance Instructions Manual

Page 1
No. 2077328 (25)
Model 3202/3202G
Drinking Fountain
INSTALLATION, OPERATION
&
MAINTENANCE INSTRUCTIONS
HAWS warrants that this specific product is guaranteed against defective material liability under this warranty shall be discharged by furnishing without charge F.O.B.
HAWS Factory any goods, or part thereof, which shall appear to the Company upon claim is made in writing to Haws within a reasonable period after receipt of the
product. Where claims for defects are made, the defective part or parts shall be cost of repairs, alterations or replacements, or for any expense connected therewith
made by the owner or his agents, except upon written authority from HAWS, Sparks, Nevada. HAWS will not be liable for any damages caused by defective
or poor workmanship, except for replacements, as provided above. Buyer agrees that HAWS shall not be liable for general, special, or consequential damages claimed to arise under the contract of sale. The drinking fountain
to function if installation and maintenance
instructions provided are adhered to. The units also must be used for the purpose
NOTE TO INSTALLER: Please leave this information with the Maintenance Department.
SHOULD YOU EXPERIENCE DIFFICULTY WITH THE INSTALLATION OF THIS
1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424
E-mail: [email protected] website: www.hawsco.com
or poor workmanship for a period of one year from date of shipment. HAWS
inspection to be of defective material or not of first class workmanship, provided that
delivered to the Company, prepaid, for inspection. HAWS will not be liable for the
materials
manufactured by HAWS is warranted for which they were intended.
NO OTHER WARRANTIES EXPRESSED OR IMPLIED ARE AUTHORIZED, PROVIDED OR GIVEN BY HAWS.
MODEL PLEASE CALL:
TECHNICAL SUPPORT: 1-800-766-5612 FOR CUSTOMER SERVICE: 1-888-640-4297
LIMITED WARRANTY
12/17 Model 3202/3202G Page 1 of 4
Page 2
TROUBLESHOOTING
PROBLEM
REPAIR CHECKLIST
1.
Insufficient bubbler flow.
1a.
Check that inlet screwdriver stop valve is in
b.
Verify minimum 30 psi flowing supply
c.
Clean strainer. See 5874 Series Valve
d.
Adjust valve to increase flow. Use front
RECOMMENDED TOOLS: Hack saw, pipe joint sealant, screwdriver, level, 12" adjustable wrench, 10" pipe wrench, 5/64“ hex key wrench, 9/16”, 1/2", 7/16” socket wrench or open end wrench.
LOCATION OF UNIT: The Model 3202/3202G Drinking Fountain is a wheelchair accessible drinking water facility. The height dimensions shown, meet current ADA requirements. When installing this unit, local, state or federal codes should be adhered to. If height other than shown is required, then dimensions must be adjusted accordingly.
SUPPLY LINE: The minimum recommended line size is 1/2“IPS with 30-90 psi (2-6 ATM) pressure. Where sediment or mineral content is a problem, an inlet filter is recommended.
PLUMBING CONNECTIONS: Inlet is 1/4" IPS male fitting. MAINTENANCE: Periodically clean the strainer. Refer to 5874 Series Valve Manual
for more information.
wide-open position.
pressure.
Manual.
adjust screw or see 5874 Series Valve Manual.
General Notes:
Before tightening nut and ferrule assembly, push tubing into fitting until it bottoms out to ensure correct engagement with O-Ring.
For more information about Haws products, see our website: www.hawsco.com
© 2017 Haws HAWS
®
®
Corporation – All Rights Reserved
and other trademarks used in these materials are the exclusive property of Haws Corporation.
12/17 Model 3202/3202G Page 2 of 4
Page 3
THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE.
NOTES: 1 5874PB (ITEM 1) INCLUDES VRK5874 CARTRIDGE ASSEMBLY
(ITEM 2) AND PBA7 RECESSED PUSH BUTTON (ITEM 3). 2 ENSURE TUBE IS DISCONNECTED FROM PUSH BUTTON VALVE
BODY PRIOR TO REMOVAL. APPLY ONE DROP OF LOCTITE 222MS TO NOZZLE THREADS PRIOR TO FASTENING BACK ONTO BUBBLER HEAD. RE-ATTACH TUBE TO VALVE.
ITEM 3202/3202G
1
BUTTON, PUSH, RECESSED, PCP W/ VALVE 5874PB
2
BUTTON ASSEMBLY, PUSH, 5874
3 4
BUBBLER HEAD ASSEMBLY, PCP
5
BIB FAUCET (OPTIONAL)
6
SPANNER WRENCH
4
(NOT SHOWN
DESCRIPTION
VRK5874VALVE REPAIR KIT
PBA7
5703M
6250LF
0006983506
SEE DETAIL A)
6
5
OPTIONAL
1
1
1
2
REMOVE INSERT
2
1
3
REF
4
WITH 5/16 HEX SOCKET (NOT SUPPLIED)
DETAIL A
ROTATED 90° INTO VIEW
PARTS BREAKDOWN
WHEN ORDERING PARTS PLEASE SPECIFY MODEL NUMBER.
C
2017
Haws Corporation - All Rights Reserved
HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation.
R
.
DRAWN
D.OLLOM
APPROVED
FV
REVISED PER
ECN:
5265
DATE 11-25-95
DATE
BYECN NO. CHKD
02/23/18
MODEL(S)
JP
GC
SCALE:
3202/3202G
1:4
DRAWING TYPE: SIZE: A
.
PARTS BREAKDOWN
1455 KLEPPE LANE
SPARKS, NEVADA 89431
(775) 359-4712 FAX (775) 359-7424
E-MAIL: [email protected] WEBSITE: WWW.HAWSCO.COM
PAGE
PART NUMBER
0002077328
REVISION
25
SHEET OF
11
3 OF 4
Page 4
1/2-13UNC X 6" LONG ANCHORS 4X
SCREWDRIVER STOP (NOT SUPPLIED)
TROUGH FLOW
CORROSION PROTECTION.
178mm
7"
MINIMUM
686mm
27"
33-1/2"
851mm
AIR GAP PROVIDED FOR
HEAVY DUTY ACCESS PANELS WITH VANDAL RESISTANT SCREWS.
LOCAL GROUND CONDITIONS).
FILL, MAY VARY DEPENDING UPON
30 CUBIC FEET MINIMUM POROUS
DRAIN PIT IF DESIRED. RECOMMEND
SEWER DRAIN (OR POROUS FILL
SLOPE CONCRETE TO FLOOR TYPE
TROUGH DRAIN
(NOT SUPPLIED)
FLOOR DRAIN
772mm
30-3/8"
IMPORTANT: ATTENTION INSTALLER
USE CARE TO AVOID KINKS WHEN ROUTING SUPPLY
LINE TO VALVE AND FROM VALVE TO BUBBLER
254mm
10"
MOUNTING DETAIL
7"
178mm
PEDESTAL
TEMPLATE
MTG BOLTS 4X
1/2"-13 UNC
1/2" ANCHOR BOLTS
MOUNTING HOLES FOR
(SUPPLIED)
IN CONCRETE SLAB 4X
1/2" IPS SUPPLY
191mm
7-1/2"
BUBBLER
TO
BIB FAUCET
STEEL FOUNTAIN
6250LF
OPTIONAL HOSE BIB DETAIL
1/2" NPT INLET
1"
25mm
(SUPPLIED).
(BY OTHERS.)
CONCRETE SLAB
30" SQUARE
38mm
1-1/2"
(TO SPOUT
OUTLET)
1 REFER TO 5874 SERIES OPERATION AND MAINTENANCE MANUAL FOR PUSH BUTTON AND VALVE INSTALLATION/MAINTENANCE INSTRUCTIONS.
NOTES:
1
6250LF BIB FAUCET OPTIONAL
1/2" NPT
STOP, COMPRESSION TUBING (NOT SUPPLIED)
FITTINGS, & 3/8" O.D.
SCREWDRIVER
(SUPPLIED)
1/2" TEE
1/2" NPT
(OPTIONAL)
1/2" TUBING AND
COMPRESSION FITTINGS
(NOT SUPPLIED)
APPROVED:
DRAWN:
PART NUMBER
SCALE:
SHEET OF
REVISION
DRAWING TYPE: SIZE: A
BY:ECN NO.
PAGE
DATE:
DATE:
ECN:
REVISED PER
CHK'D.:
Haws Corporation - All Rights Reserved.
HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation.
C
R
MODEL(S)
1455 KLEPPE LANE
SPARKS, NEVADA 89431
(775) 359-4712 FAX (775) 359-7424
E-MAIL: [email protected] WEBSITE: WWW.HAWSCO.COM
THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE.
C. HAYES
11/91
25
0002077328.D
3202/3202G
.
1:14
11
FV
02/23/18
.
GC
4 OF 4
INSTALLATION
5265
2018
JP