This is a Class B product. In a domestic environment, this product may cause radio interference, in
which case the user may be required to take adequate measures.
LIMITED WARRANTY
Hawking Technology guarantees that every HWBA54G Wireless-G AP / Bridge is free from physical
defects in material and workmanship under normal use for two (2) years from the date of purchase.
If the product proves defective during this two-year warranty period, call Hawking Customer Service
in order to obtain a Return Authorization number. Warranty is for repair or replacement only.
Hawking Technology does not issue any refunds. BE SURE TO HAVE YOUR PROOF OF PURCHASE.
RETURN REQUESTS CAN NOT BE PROCESSED WITHOUT PROOF OF PURCHASE. When returning
a product, mark the Return Authorization number clearly on the outside of the package and include
your original proof of purchase.
IN NO EVEN SHALL HAWKING TECHNOLOGY’S LIABILTY EXCEED THE PRICE PAID FOR THE
PRODUCT FROM DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES
RESULTING FROM THE USE OF THE PRODUCT, ITS ACCOMPANYING SOFTWARE OR ITS
DOCUMENTATION. Hawking Technology makes no warranty or representation, expressed, implied
or statutory, with respect to its products or the contents or use of this documentation and all
accompanying software, and specifically disclaims its quality, performance, merchantability, or
fitness for any particular purpose. Hawking Technology reserves the right to revise or updates its
products, software, or documentation without obligation to notify any individual or entity. Please
direct all inquiries to:techsupport@hawkingtech.com
TRADEMARKS AND COPYRIGHT
Windows 95/98/ME and Windows NT/2000/XP are registered trademarks of Microsoft Corp. All other
brands and product names are trademarks of their respective companies.
No part of this publication may be reproduced in any form or by any means or used to make any
derivative (such as translation, transformatio n or adaptation) without the express written consent of
the manufacturer as stipulated by the United States Copyright Act of 1976.
FCC WARNING
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one of the following measures:
- Reorient or relocate the receiving a ntenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: Any changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate this equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
IMPORTANT NOTE:
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated
with minimum distance 20cm between the radiator & your body. This
transmitter must not be co-located or operating in conjunction with any other
antenna or transmitter.
Thank you for purchasing the Hawking Technologies Hi-Speed 54M Wireless-G Access
Point and Ethernet Bridge. The HWBA54G is compliant with the IEEE 802.11g/b wireless
standards.
The Hi-Speed 54G Wireless AP/Bridge utilizes the highest wireless security standards
(WPA) to protect your network from outside intruders, including WPA -PSK, WEP, ESSID
and MAC address filter functions. With ESSID authentication, WPA-PSK, 64 -/128-bit WEP
encryption and MAC address filtering, unauthorized outside access into your wireless
network is prevented.
The unique multi-function feature of the HWBA54G puts two solutions into one compact
unit, saving you time and money. You may setup your HWBA54G as a Wireless Access
Point to provide wireless access to any wired network or you may choose to set up your
device as an Ethernet Bridge to make any Ethernet-ready device wireless.
The HWBA54G’s dipole antenna is detachable by connecting to a RP-SMA connector.
Users can attach an optional Hawking Technologies Hi -Gain antenna to the connector for
better network range and signal quality.
2
1.1 Package Contents
The HWBA54G includes the following items:
l One HWBA54G Access Point/Bridge
l One Power Adapter
l One Quick Installation Guide
l One Setup CD
l One Dipole Antenna
1.2 Features
Ÿ Complies with the IEEE 802.11b/g (DSSS) 2.4GHz specification.
Ÿ Multiple Functions: Access Point, Ethernet Bridge, WDS Bridge etc…
Ÿ High wireless data rate 54Mbps network speed.
Introduction
Ÿ Seamlessly integrate s wireless and wired Ethernet networks.
Ÿ Auto rate fallback in case of obstacles or interferences.
Ÿ Provide 64/128 -bit WEP and WPA Data Encryption function to protect the
wireless data transmissions.
Ÿ Built-in DHCP server supports auto IP addresses assignment.
Ÿ Supports Web-based configuration.
Ÿ Easy Setup Wizard for simple configuration
1.3 Specifications
Ÿ Standards: IEEE 802.11b/g (Wireless), IEEE 802.3 (Wired)
Ÿ Data Rate: 54/48/36/24/18/12/11/9/6/5.5/2/1Mbps auto fallback
Ÿ Security: 64/128-bit WEP and WPA Data Encryption
Ÿ Frequency Band: 2.400~2.4835GHz (Industrial Scientific Medical Band)
Ÿ Modulation: CCK@11/5.5Mbps, DQPSK@2Mbps and DBPSK@1Mbps
Ÿ Radio Technology: Direct Sequence Spread Spectrum (DSSS)
Ÿ Antenna: External detachable dipole antenna (with RP-SMA connector)
Compatible with Hawking Technologies Hi-Gain Wireless Range Extending
Antennas and Boosters.
Ÿ Connectors: 10/100Mbps RJ-45 x 1
Ÿ Power: 12VDC, 0.5A
3
Ÿ Transmit Power: 15dBm (Typical)
Ÿ LEDs: Power, LAN Link/Activity, Wireless Activity
Ÿ Dimension: 30(H) x 127(W) x 96(D) mm
Ÿ Temperature:
Ÿ Humidity: 10-90% (Noncondensing)
Ÿ Certification: FCC, CE
Introduction
Introduction
4
1.4 Physical Description
Front Panel
Located on the HWBA54G’s front panel are LED status lights that inform you of the unit’s
current status. Below is an explanation of each LED.
5
LED Color Status Description
Introduction
Power Green
Lit Power is supplied.
Off No Power.
Flash Antenna is transmitting or receiving data.
Wireless
Activity
Green
Off
Antenna is not transmitting or receiving
data.
On A valid link is established.
LAN
Green
Flash It is transmitting or receiving data.
Link/Activity
Off No link is established.
Back Panel
Access Point’s connection ports are located on the back panel. Below is the
description of each connection port.
Ÿ Antenna Connector
This round connection is standard Reverse SMA connector where any
antennas with Reverse SMA connector can connect to the Access Point.
Ÿ DC Adapter Port
Insert the power jack of the power adapter into this port.
Ÿ LAN Port
The Access Point’s LAN port is where you connect to your LAN’s network
devices.
Ÿ Reset
The Reset button allows you to do one of two things.
1) If problems occur with your Access Point, press the reset button with
a pencil tip (for less than 4 seconds) and the Access Point will reboot itself, keeping your original configurations.
Introduction
6
2) If problems persist or you experience extreme problems or you
forgot your password, press the reset button for longer than 4
seconds and the Access Point will reset itself to the factory default
settings (warning: your original configurations will be replaced with
the factory default settings).
Wireless LAN Access Point Connection
7
Chapter 2 Wireless LAN Access Point
Connection
1. Locate an optimum location for the Wireles s Access Point.
The best location for your Access Point is usually at the center of your
wireless network, with line of sight to all of your mobile computers. A
higher location is also preferable. (i.e. the second story of a house versus
the first level)
2. Connect the Wireless LAN Access Point to your router, hub or switch.
Connect one end of included Ethernet cable to the Access Point’s LAN
Port and connect the other end of the cable to a switch, a router or a hub.
The Access Point will then be connected to your existed wired LAN
Network.
3. Connect the DC Power Adapter to the Wireless LAN Access Point’s
Power Socket.
Only use the power adapter supplied with the Access Point. Using a
different adapter may damage the product.
The Hardware Installation is c omplete.
HWBA54G – Wireless-G Access Point / Ethernet Bridge
8
Chapter 3 Wireless LAN Access Point
Configuration
3.1 Getting Started
This Access Point provides web-based configuration tool allowing you to
configure from wired or wireless computers. Follow the instructions below to
get started configuration.
From Wired Computer
1. Make sure your wired computer is in the same subnet with the Access
Point.
The default IP Address and Sub Mask of the Access Point is:
Default IP Address: 192.168.1.240
Default Subnet: 255.255.255.0
Configure your PC to be in the same subnet with t he Access Point.
1a) Windows 95/98/Me
1.Click the Start button and select Settings, then click Control Panel. The Control Panel
window will appear.
2. Double-click Network icon. The Network window will appear.
3. Check your list of Network Components. If TCP/IP is not installed, click the Add button to
install it now. If TCP/IP is installed, go to step 6.
4. In the Network Component Type dialog box, select Protocol and click Add button.
5. In the Select Network Protocol dialog box, select Microsoft and TCP/IP and then click the
OK button to start installing the TCP/IP protocol. You may need your Windows CD to
complete the installation.
6.After installing TCP/IP, go back to the Network dialog box. Select TCP/IP from the list of
Network Components and then click the Properties button.
7. Check each of the tabs and verify the following settings:
•Bindings: Check Client for Microsoft Networks and File and printer sharing for
Microsoft Networks .
• Gateway: All fields are blank.
• DNS Configuration: Select Disable DNS.
HWBA54G – Wireless-G Access Point / Ethernet Bridge
• IP Address: Select Specify an IP Address. Specify the IP Address and Subnet Mask
as following example.
1. IP Address: 192.168.1.20 (any IP address within 192.168.1.1~192.168.1.253 is
available, do not setup 192.168.1.1 or 192.168.1.254) üSubnet Mask: 255.255.255.0
8.Reboot the PC. Your PC will now have the IP Address you specified.
1b) Windows XP
1: Click the Start button and select Settings, then click Network Connections. The Network
Connections window will appear.
2: Double -click Local Area Connection icon. The Local Area Connection window will appear.
3: Check your list of Network Components. You should see Internet Protocol [TCP/IP] on your list.
Select it and click the Properties button.
4: In the Internet Protocol (TCP/IP) Properties window, select Obtain an IP address automatically and
Obtain DNS server address automatically as shown on the following screen.
HWBA54G – Wireless-G Access Point / Ethernet Bridge
10
5: Click OK to confirm the setting. Your PC will now obtain an IP address automatically
from your Broadband Router’s DHCP server.
Note: Please make sure that the Broadband router’s DHCP server is the only DHCP server available on your LAN.
Once you’ve configured your PC to obtain an IP address automatically, please proceed to
Step 3.
1c) Windows 2000
1.Click the Start button and select Settings, then click Control Panel. The Control Panel
window will appear.
2.Double-click Network and Dial -up Connections icon. In the Network and Dial-up
Connection window, double-click Local Area Connection icon. The Local Area Connection
window will appear.
3. In the Local Area Connection window, click the Properties button.
4. Check your list of Network Components. You should see Internet Protocol [TCP/IP] on
your list. Select it and click the Properties button.
5.In the Internet Protocol (TCP/IP) Properties window, select Use the following IP address
and specify the IP Address and Subnet mask as following.
HWBA54G – Wireless-G Access Point / Ethernet Bridge
11
üIP Address: 192.168.1.20 (any IP address within 192.168.1.1~192.168.1.253 is
available, do not setup 192.168.1 .1 or 192.168.1.254 )
üSubnet Mask: 255.255.255.0
6.Click OK to confirm the setting. Your PC will now have the IP Address you specified.
1d) Windows NT
1.Click the Start button and select Settings, then click Control Panel. The Control Panel
window will appear.
2.Double-click Network icon. The Network window will appear. Select the Protocol tab from
the Network window.
3.Check if the TCP/IP Protocol is on your list of Network Protocols. If TCP/IP is not installed,
click the Add button to install it now. If TCP/IP is installed, go to step 5.
4.In the Select Network Protocol window, select the TCP/IP Protocol and click the Ok
button to start installing the TCP/IP protocol. You may need your Windows CD to
complete the installation.
5.After you install TCP/IP, go back to the Network window. Select TCP/IP from the list of
Network Protocols and then click the Properties button.
6. Check each of the tabs and verify the following settings:
•IP Address: Select Specify an IP address. Specify the IP Address and Subnet Mask
as following example.
1. IP Address: 192.168.1.20 (any IP address within 192.168.1.1~192.168.1.253 is
available, do not setup 192.168.1.1 or 192.168.1.254)
üSubnet Mask: 255.255.255.0
• DNS: Let all fields are blank.
• WINS: Let all fields are blank.
• Routing: Let all fields are blank.
7.Click OK to confirm the setting. Your PC will now have the IP Address you specified.
2. Enter 192.168.1.240 from a Web Browser to get into the Access Point’s
configuration tool.
3. A screen will be popped up and request you to enter user name and
password. The default user name and password is as follows.
User Name: Admin
Password: 1234