Hawk BVP25D User Manual

Page 1
Side Mount
3-Speed Switch and
Dual GFCI Power Outlets
900 CFM Air Mover
Dry Floors, Circulate and Exhaust Air
Hawk BVP25D User’s Manual Hawk BVP25D User’s Manual
Daisy Chain up to
5 Units for Extra Air
HAWK HAWK
ENTERPRISES ENTERPRISES
Works in Tight Spaces for
Tough Drying Jobs
HAWK ENTERPRISES - 2902 Park Six Court, Elkhart, IN 46514
(574) 294-1910 - www.hawkenterprises.com
HAWK ENTERPRISES - 2902 Park Six Court, Elkhart, IN 46514
(574) 294-1910 - www.hawkenterprises.com
Subject to Change Without Noce
Specificaons
Model BVP25D Motor 1/4 HP, 115V, 60Hz with 10 . 14 AWG Cord Aached Air Volume 900 CFM (High), 700 CFM (Med), 690 CFM (Low Speed) Amp Draw 2.1 Amp (High), 1.8 Amp (Med), 1.7 Amp (Low Speed) Air Flow Direcons 0, 45 and 90 degrees Max Stac Pressure 1.3ʺ Chassis Construcon Sturdy Rotomolded Plasc Stackable in Storage 5 units Daisy Chain Yes - Up to 5 Units Weight 11.3 lbs. (net) / 12.6 lbs. (gross) Size (LxWxH) 12.8” x 12.4” x 13.3” Sound Level 67 dB Cerficaon C-ETL-US
Air Flow in 3 Angles
0, 45 & 90 Degrees
12.8”
12.4”
13.3”
Hawk Limited Warranty
Hawk Enterprises Inc. equipment has been manufactured, tested and inspected with carefully engineered requirements. Hawk warrants each new machine, part and accessory to be free of defects in materials and workmanship for a me specified in the table below. Repair or replacement of defecve parts or service must be conducted by a Hawk authorized service provider.
Warranty Start Date: Warranty coverage starts on the date the machine is installed at the end user's site, or six months from the ship date from the factory, whichever comes first. The distributor who sold you the machine is responsible for compleng the registraon form at www. hawkenterprises.com/service_registraon. This forms idenfies the machine and records warranty state date.
Warranty Coverage - Hawk Air Movers Motor and Gearbox - 1 year Non-Wear Items - 6 months Repair Parts - 90 days Service Labor - 6 months
Excepons and Exclusions from the Limited Warranty
This warranty does not cover repairs resulng from accident, abuse, misuse, damage in transit, or lack of proper maintenance. Equipment must be used with electric current noted on the data plate.
Damages from operaon at other voltages or currents will void the warranty.
Certain normal wear parts are consumed in use of this machine, and are not covered by this warranty. These parts include, but are not limited too, cords, switches, bumpers, bearings, isolators, carbon motor brushes, compensators, brushes, pad drivers, bulbs, bags, v-belts and filters. No other warranes extend beyond the terms of this Hawk Limited Warranty, including implied warranty of merchantability or fitness of this machine for a parcular use.
How to Set Up Warranty Repair
Equipment must be repaired by a Hawk approved service provider; the dealer who sold the new equipment or any Hawk distributor service department in the US. Repairs or alteraons made by anyone other than the Hawk factory or a cerfied repair staon, will void the warranty.
The distributor who sold you the machine is responsible for registraon of the machine with the factory. With this registraon, Hawk will have all of the records required for warranty claim, including records of ownership, date of delivery and resulng warranty dates and terms, distributor's locaon, machine model, type and serial number. To find the closest service provider, contact Hawk Customer Service at 1-574-294-1910 or [email protected]. Warranty claims must be submied within 30 days of service request.
Replacement
In the event of a malfuncon resulng in a warranty claim, Hawk, may at its sole opon, replace the equipment or warranted part with another new part of equal quality instead of repairing that part.
No Refund of Purchase Price
Hawk will not, as a maer of this warranty agreement, refund the end user's purchase price.
Page 2
Unpacking & Checking Of Contents
Unpack your BVP25D carefully and inspect if all parts are intact. If any of the parts are missing damaged, please contact Hawk Customer Service at (574) 294-1910 or e-mail to [email protected].
Operang Instrucons
This BVP25D requires NO ASSEMBLY. The unit is packaged and ready to be put to work. The unit is intended to be used for drying carpet spills, drying surfaces such as bathroom floors, venlang as well as circulang air.
1. Place the unit on the surface that needs to be dried.
2. Plug the unit into a grounded outlet .
3. Select the desired speed and posion
Floors and Carpet Maintenance
WARNING: As with all electrical equipment, the unit must be disconnected from power before servicing or cleaning.
Ÿ Before each use, inspect the unit for damage, blocked inlets and exhaust and for
foreign material buildup.
Ÿ When the air mover is turned on, inspect the unit for excessive vibraon. In the event
of excessive vibraon or if the fan wheel rubs against the rotomolded housing, immediately turn off the unit and have a cerfied technician inspect the unit.
HAWK ENTERPRISES - 2902 Park Six Court, Elkhart, IN 46514
(574) 294-1910 - www.hawkenterprises.com
HAWK ENTERPRISES - 2902 Park Six Court, Elkhart, IN 46514
(574) 294-1910 - www.hawkenterprises.com
ATTENTION!
Read all safety rules carefully before aempng to operate the BVP25D. Please retain this manual for future reference. NEVER operate this unit when flammable materials or vapors are present -- electrical devices produce arcs or sparks which may cause a fire or an explosion. NEVER operate this unit unaended.
WARNING!
To reduce the risk of fire, electric shock or injury, follow the direcons below:
Ÿ Do not use an extension cord with this air
mover.
Ÿ Do not use with solid state speed control
device.
Ÿ Do not allow to be used as a toy. Close
aenon is necessary when used by or near children.
Ÿ Do not unplug by pulling on cord. To unplug,
grasp the plug, not the cord.
Ÿ Do not use with damaged cord, plug or
other parts.
Ÿ Call customer service if your air mover is not
working as it should, has missing parts, has been dropped, damaged, le outdoors or dropped into water.
Ÿ Do not pull or carry by cord, use cord as
handle, close a door on cord, or pull cord around sharp edges or corners. Keep cord away from heated surfaces.
Ÿ Do not run cord under carpeng. Do not
cover cord with throw rugs, runners or
Ÿ Use product only as described in this
manual.
Ÿ To reduce the risk of electric shock, do not
expose to rain, immerse in or use in standing water. Store indoors only.
Ÿ Use only with GFCI-protected outlets. Ÿ When storing or transporng, do not stack
air movers more than 5 units high.
Ÿ Electrical appliances can ignite flammable
vapors or dust. Do not use near combusble liquids, gases or dusts.
Ÿ Do not leave plugged into outlet when not in
use or when servicing. Turn off before unplugging.
Ÿ To reduce the risk of srring up and inhaling
toxic vapors, do not use near toxic or hazardous materials.
Ÿ Never operate with safety grills removed. Ÿ This unit has an automacally-operated
protecve device which may shut down the unit during operaon. Unplug before servicing or cleaning.
WARNING!
Ÿ To reduce the risk of electric shock, connect only to a GFCI
protected outlet. Do not expose to water
CAUTION
Ÿ This air mover has an automac motor shutoff device. It
may restart without noce.
Ÿ To reduce the risk of injury, unplug before servicing.
WARNING!
Ÿ Do not use an extension cord with this fan. To reduce the
risk of p-over during storage or transport, stack up to 5 units high only.
32
BVP25D
0 degrees
BVP25D
45 degrees
BVP25D
90 degrees
HAWK HAWK
ENTERPRISES ENTERPRISES
Hawk BVP25D User’s ManualHawk BVP25D User’s Manual
Page 3
Motor Specificaons & Electrical Requirements
This BVP25D has a 1/4 HP, 3-speed, 115-volt, 60 Hz inducon motor with a grounding conductor. Thermally protected, it will automacally shut down if overheated. The motor will restart automacally once cooled, for as long as it is plugged into a power source. In the event of a malfuncon or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock.
This air mover is equipped with an 10 . 14 AWG electric power cord having an equipment grounding conductor and a grounding plug. The plug must be plugged into a matching outlet that is properly installed and grounded in accordance with all local codes and ordinances. Do not modify the plug provided. If it will not fit the outlet, have the proper outlet installed by a qualified electrician.
Power Cords
Ÿ Use three-pronged adapters that are UL and CE approved and with Ground Fault
Circuit Interrupter (G.F.C.I.).
Ÿ Do not use cords that show any kind of wear or damage. Ÿ Cords are not covered by warranty
WARNING! The Total amperage of the BVP25D Air Mover plus all other devices plugged into the receptacle must not exceed 12 amps.
Grounding Instrucons
The BVP25D must be grounded. Should it malfuncon, grounding provides a path of least resistance for electric current and reduces the risk of electric shock. This appliance is equipped with a cord that has an equipment-grounding conductor and a grounding plug. The plug must be inserted into a properly installed and grounded outlet, in accordance with all local
WARNING!
Improper connecon of the equipment­grounding conductor can result in the risk of an electric shock.
Check with a qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the appliance. If plug does not fit the outlet, have a proper outlet installed by a qualified electrician. NOTE: In Canada, the use of a temporary adapter is not permied by the Canadian Electrical Code
Use with 115V
3-Prong Grounded
Connection
DO NOT
Use with a 3-Prong to
2-Prong Adapter
HAWK ENTERPRISES - 2902 Park Six Court, Elkhart, IN 46514
(574) 294-1910 - www.hawkenterprises.com
HAWK ENTERPRISES - 2902 Park Six Court, Elkhart, IN 46514
(574) 294-1910 - www.hawkenterprises.com
54
Lubricaon
NO LUBRICATION IS NECESSARY. The motor is equipped with lifeme lubricated bearings.
Storage & Transportaon
1. Before storing your air mover, it should be cleaned.
2. Wrap the power cord around the carry handle on top of the unit to keep it untangled.
3. If you have more than one unit, store units by stacking. Do not stack more than 5 units high.
4. Never operate unit while on its side or while stacked.
5. THE BVP50 SHOULD BE STORED INDOORS.
CAUTION:
Do not operate this air mover stacked on top of each other. Do not stack more than 5 units high for storage.
Servicing
In order to receive service or replacement parts under warranty, you must:
1. Call (574) 294-1910 for an RMA (Return Merchandise Authorizaon Number)
2. Have your proof of purchase ready.
Upon inspecon, we will advise you of the repairs needed and the cost (if applicable). Hawk will issue repair or replacement parts depending on warranty.
Cleaning
WARNING: To reduce the risk of injury from the air mover accidentally
starng, unplug power cord before cleaning. The outside of the unit may be cleaned with a damp cloth to remove any dust or residue.
User Servicing Instrucons WARNING: Be sure to disconnect power supply before aempng to
service or remove any components. Do not aempt to service your air mover beyond what is described in the user manual. For all other servicing, follow instrucons in the Warranty secon.
HAWK HAWK
ENTERPRISES ENTERPRISES
Hawk BVP25D User’s ManualHawk BVP25D User’s Manual
Page 4
rotomolded chassis
10’ powercord
air intake grill
motor
fan
air intake grill
air exhaust grill
rubber feet
76
HAWK ENTERPRISES - 2902 Park Six Court, Elkhart, IN 46514
(574) 294-1910 - www.hawkenterprises.com
HAWK ENTERPRISES - 2902 Park Six Court, Elkhart, IN 46514
(574) 294-1910 - www.hawkenterprises.com
Pr ob lem
Po ss ible C aus e
So lu tion
U nit No t R un nin g
Sw itc h i s o ff
Tu rn on
N o p ow er
Pl ug un it i n; c he ck circ uit br ea ker
Ba d out let
Ch ec k o ut let, ch an ge to a d iffe ren t ou tle t
Fa ult y S wi tch
Re pl ace sw itc h*
Fa ult y o r b ro ken m oto r w ire or cor d
U se vol t/a mp m ete r t o c hec k co nt inu ity . R ep lac e m ot or wir e o r co rd *
U nit run s b ut m ake s lo ud , gr ati ng no ise s
Se ve re jolt ing ca us es bl ow er wh ee l to ru b ag ain st ho use
Re m ove an d rep lac e d am ag ed m oto r or m oto r m ou nt s* if n ee ded
Se ve re jolt ing de fo rm ed ho us ing
Re pl ace bl ow er wh ee l or da m age d ho us ing *
Ex ce ssiv e v ib rat ion
Se ve re jolt ing ca us ed m oto r s ha ft t o b en d – un it is o ut of ba lan ce
Re m ove an d rep lac e m o tor * D am age d b lo we r w he el bl ad e
Re m ove r b low er w he el*
Bu ild-u p o f dir t o n o ne sid e of b lo we r w he el
Cl ean b low er wh ee l b lad es
Bl ow er wh ee l no t tu rn ing
Bl ow er wh ee l ja mm ed ag ain st ho usi ng
Re m ove an d rep lac e d am ag ed m oto r m ou nts * R ep lac e b low er w he el i f ne ed ed *
Br ok en/ loo se ca pa cito r w hee l; fail ed cap ac ito r
Re pl ace ca pa cito r w ir e/m ot or if ne ed ed *
D am age d h ou sin g i s pr ess in g o n b low er w hee l
Re pl ace ho us ing /u nit , if nee de d*
U nit run s b ut sh uts of f on o ver loa d
Fa ilin g m o tor be ari ng s. In ter na l el ect ric al f aul t in m oto r
Re pl ace m oto r*
O bst ruc tio n i n in ta ke gr ill o r e xh au st g rill
Re m ove ob st ruc tio n
HAWK HAWK
ENTERPRISES ENTERPRISES
TroubleshootingConstruction & Parts
Hawk BVP25D User’s ManualHawk BVP25D User’s Manual
3-Speed Switch
Two GFCI 110 V Outlets
Circuit Breaker
control panel
switch knob
circuit breaker (2) 110V outlets
Loading...