Havis is pleased to provide this Owner’s Manual to aid in the proper installation and use of the DS-DELL-100 Series/220 Series Docking Station for the Dell XFR & ATG laptop computers.
For questions regarding the set-up of your DS-DELL-100 Series/220 Series Docking Station, please contact Havis at 1-800-524-9900 or visit www.havis.com for additional product support and information.
This Owner’s Manual applies to the following Part Numbers:
DS-DELL-101 DS-DELL-101-3 DS-DELL-103
• NEVER STOW OR MOUNT THE DOCKING STATION DIRECTLY IN A VEHICLE AIRBAG DEPLOYMENT ZONE.
• DO NOT USE COMPUTER WHILE DRIVING.
• READ ALL INSTRUCTIONS THOROUGHLY BEFORE BEGINNING INSTALLATION.
• DO NOT MATE COMPUTER TO DOCKING STATION UNLESS COMPUTER’S DOCKING CONNECTOR ACCESS DOOR IS FULLY OPEN OR DAMAGE MAY RESULT. (SEE BELOW)
DS-DELL-221 DS-DELL-223
Dell E6420 XFR shown with Connector Access Door in closed position (left) and open position (right)
2 11
• FOR SAFE & PROPER SYSTEM FUNCTION, SPECIFIC DOCKING STATION MODELS MUST BE USED WITH SPECIFIC DELL COMPUTER MODELS.
- DS-DELL-100 SERIES (101, 103, ETC.) DOCKING STATIONS ARE INTENDED FOR USE WITH DELL E6400, E6410 & E6420 XFR COMPUTERS ONLY.
- DS-DELL-220 SERIES (221, 223) DOCKING STATIONS ARE INTENDED FOR USE WITH DELL E6400, E6410, & E6420 ATG COMPUTERS ONLY.
- THE PORT COVERS SUPPLIED WITH DELL E6400 & E6410 ATG COMPUTERS MUST BE REMOVED PRIOR TO DOCKING.
- THE PORT COVERS SUPPLIED WITH DELL E6420 ATG COMPUTER MAY REMAIN SECURED TO COMPUTER WHILE DOCKING.
• COMPUTER & DOCKING STATION IDENTIFICATION:
COMPUTER MODEL DOCKING STATION IDENTIFICATION
No Foot Pads on top plate.
Low prole Front Hooks.
E6400/6410/6420 XFR DS-DELL-100 Series
Foot Pads on top plate. Macro Alignment
Brackets attached.
E6400/6410/6420 ATG DS-DA-220 Series
Precautions
• Do not place metal objects or containers of liquid on top of the Docking Station
• If a malfunction occurs, immediately unplug the Power Supply and remove the laptop
• Use only the specied Power Supply (Part # LPS-105) with this Docking Station
• Do not store the Docking Station where water, moisture, steam, dust, etc. are present
• Do not connect cables into ports other than what they are specied for
• Do not leave the Docking Station in a high temperature environment (greater than 75°C, 167°F)
for a long period of time
www.havis.com • 1-800-524-9900
Table of Contents
Specications
Parts Included
Port Replication Capability
Installation
Cable Management
Operation - Docking
Operation - Undocking
Specications
Power Supply Input 20V DC-In
Dimensions 13.6” ( 34.4 cm) W x 12.7” ( 32.3 cm ) D x 3.7” ( 9.4 cm ) H
Weight 6.6 lbs ( 2.9 kg )
DS-DELL-100 Series Docking Stations for DELL E6400, E6410, E6420 XFR Computers
Operating Environment 0° C to 40° C ( 32° F to 104°F )
Storage Environment -60° C to 75° C ( -76° F to 167° F )
DS-DELL-220 Series Docking Stations for DELL E6400, E6410, E6420 ATG Computers
Operating Environment 0° C to 35° C ( 32° F to 95°F )
Storage Environment -60° C to 75° C ( -76° F to 167° F )
4
5
5
6
7
9
10
DECLARATION OF CONFORMITY FOR CE MARKING
Havis, Inc. declares that their DS-DELL-100 & DS-DELL-220 SERIES DOCKING STATIONS: Are classied within the following EU Directives:
EU Electromagnetic Compatibility Directive 2004/108/EC, 2009/19/EC
And further conform with the following EU Harmonized Standards:
EN 55022 (2006) + A1 2007, EN 55024: 1998 + A1: 2001 + A2: 2003 EN 50498: 2010
Clause 7.1 Broadband Radiated Disturbances - Quasi-Peak Clause 7.2 Narrowband Radiated Disturbances - Average Clause 7.3 Conducted Radiated Disturbances - Severity Level 2
Dated: September 28 , 2011 Position of signatory: Chief Information Officer / Chief Financial Officer Name of signatory: Steve Ferraro