Hatco GRS-18 Installation Manual

FOOD WARMER
Glo-Ray
®
Standard and Portable
Installation &
Operating Manual
I&W #07.05.042.00
SPEISEWÄRMER Installations- und Bedienungshandbuch
Modelle: GLO-RAY
®
Standard- und Tragbare Ausführung
RAMPES CHAUFFANTES Installation et Fonctionnement
Modèle: GLO-RAY
®
Courant et portatif
VOEDSELVERWARMER
Handleiding voor Installatie en Bediening Model: GLO-RAY
®
Standaard en Draagbare Versieh
CALENTADORES DE COMIDAS
Manual de Instalación y Operación
Modelo: Glo-Ray
®
Estándar y portátil
RISCALDATORI
Manual de Instalación y Operación
Modelo: Riscaldatori di Cibo Glo-Ray
®
Standard e Portatile
Glo-Ray®Food Warmer
1
GENERAL
Safety precautions preceded in this manual by the words WARNING or CAUTION printed in bold face are important. WARNING means there is the possibil- ity of personal injury to yourself or others. CAUTION means there is the possibility of damage to the unit.
ELECTRICAL SPECIFICATIONS
GLO-RAY INFRARED FOODWARMERS
Glo-Ray Food Warmers operate on 120, 220 or 240 volts depending on order specifications.
PORTABLE FOODWARMERS
Portable Foodwarmers operate on 120, 220 or 240 volts.
* Indicates models that accommodate multiple food pans: 30" (76 cm)=2 pans, 42" (107 cm)=3 pans, 54" (137 cm)=4 pans and 66" (168 cm)=5 pans.
** Based on standard width of 19-1/2" (50 cm).
Stainless Steel Housing – 220-230 Volts
High Standard
Model Wattage Model Wattage
GRH-24 546 GR-24 383 GRH-36 874 GR-36 628 GRH-48 1202 GR-48 874 GRH-60 1530 GR-60 1148 GRH-72 1913 GR-72 1394 GRH-96 2623 GR-96 1885
220-230V 230-240V
Model Watt Amps Watt Amps
GR-B 273 1.30 250 1.04 GRFF 546 2.59 500 2.08 GRFFL 678 3.22 620 2.58 GRFFB 820 3.90 750 3.13 GRFFBL 951 4.52 870 3.63
FRY STATIONS
220-230V 230-240V
Model Watt Amps Watt Amps
GRFS-24 546 2.59 500 2.08 GRFSL-24 678 3.22 620 2.58 GRFSR-24 546 2.59 500 2.08 GRFSLR-24 131 0.62 120 5.00
HEATED SHELVES
220-230V 230-240V
Model Watt** Amps Watt** Amps
GRS-18 262 1.25 240 1.00 GRS-24 328 1.56 300 1.25 GRS-30* 404 1.92 370 1.54 GRS-36 481 2.29 440 1.83 GRS-42* 546 2.59 500 2.08 GRS-48 612 2.91 560 2.33 GRS-54* 700 3.33 640 2.67 GRS-60 765 3.64 700 2.92 GRS-66* 842 4.00 770 3.21 GRS-72 918 4.36 840 3.50
Stainless Steel Housing – 230-240 Volts
High Standard
Model Wattage Model Wattage
GRH-24 500 GR-24 350 GRH-36 874 GR-36 575 GRH-48 1100 GR-48 800 GRH-60 1400 GR-60 1050 GRH-72 1750 GR-72 1275 GRH-96 2400 GR-96 1725
Aluminum Housing – 220-230 Volts
High Standard
Model Wattage Model Wattage
GRAH-18 383 GRA-18 273 GRAH-24 546 GRA-24 383 GRAH-30 721 GRA-30 492 GRAH-36 874 GRA-36 628 GRAH-42 1038 GRA-42 738 GRAH-48 1202 GRA-48 874 GRAH-54 1366 GRA-54 1011 GRAH-60 1530 GRA-60 1148 GRAH-66 1705 GRA-66 1268 GRAH-72 1885 GRA-72 1394 GRAH-84 2241 GRA-84 1639 GRAH-96 2623 GRA-96 1885
Aluminum Housing – 230-240 Volts
High Standard
Model Wattage Model Wattage
GRAH-24 500 GRA-24 350 GRAH-30 660 GRA-30 450 GRAH-36 800 GRA-36 575 GRAH-42 950 GRA-42 675 GRAH-48 1100 GRA-48 800 GRAH-54 1250 GRA-54 925 GRAH-60 1400 GRA-60 1050 GRAH-66 1560 GRA-66 1160 GRAH-72 1725 GRA-72 1275 GRAH-84 2050 GRA-84 1500 GRAH-96 2400 GRA-96 1725
Glo-Ray®Food Warmer
2
Figure 1. Chain Mounting
ELECTRICAL REQUIREMENTS
For proper installation to local electrical code consult a licensed electrical contractor.
CORD AND PLUG PROVIDED MODELS
Install an approved grounded receptacle to receive plug of models provided with supply cord and plug set.
PERMANENT INSTALLATIONS
Install a supply wire not lighter than 10-gauge copper, rated 90°C (194°F).
CONTROL SWITCHES
When two or more Glo-Ray units are mounted in a situa­tion where the heat from one housing tends to raise the temperature of another, the control switches should be installed in a suitable control box away from the heated zone. Glo-Ray units ordered for multiple installation should not have switches built-in.
LOCATION
It is necessary for safe and proper operation that the food warmer be mounted a reasonable distance from combustible wall and counter top surfaces. When proper distances are maintained, hot foods will be held at ideal serving temperatures without cooking the foods beyond the point of excellence.
NOTE: Glo-Ray is not moisture-proof. Do not mount over steamtable unless control switch is in a remote location.
WARNING
Electrical grounding is required on this appliance. The grounding must come from the main power supply source and then connected throughout the appliance.
WARNING
Specified safe distances must be maintained between the Glo-Ray and combustible wall or wall type surfaces and wooden counters or counters that would discolor. If safe distances are not main­tained, discoloration or combustion could occur.
STANDARD WATTAGE GLO-RAY
Locate standard wattage Glo-Rays so there is a mini­mum distance of 10" (25 cm) between the bottom of the Glo-Ray and wooden counters or counters that would discolor.
HIGH WATTAGE GLO-RAY
Locate high wattage Glo-Ray so there is a minimum distance of 13.5" (34,3 cm) between the bottom of the Glo-Ray and wooden counters or counters that would discolor.
CHAIN SUSPENDED OR WALL MOUNTED GLO-RAY
Locate a chain suspended, or wall bracket mounted Glo-Ray so there is a minimum distance of 3" (7,6 cm) from a nonmetallic wall or adjacent surface.
MOUNTING
GENERAL
Glo-Rays are supplied with 2 mounting tabs at each end for chain mounting (See Figure 1) or mounting under a shelf or pass through (See Figure 6). C-Leg stands, T-Leg stands, wall brackets and tubular stands are available. C-Leg and T-Leg stands can be attached to any standard Glo-Ray. A Glo-Ray is prepared for tubular stand mounting if requested when ordered. Use only recommended mounting methods and approved accessories with your Glo-Ray.
WARNING
Chain must be of sufficient strength and securely fastened or the Glo-Ray Warmer could come loose, possibly causing personal injury or damage to the unit.
Overhead chain
Connecting chain
3"
(7,6 cm)
min.
10" (25,4 cm) minimum
Standard Wattage
13.5" (34,3 cm) minimum High Wattage
Non-metallic wall
Non-metallic surface
Glo-Ray®Food Warmer
3
Locking
screw
Adjustable
Non-adjustable
UNDER SHELF
(see Figure 4 & 5)
When mounting the Glo-Ray under a shelf keep any switches in the coolest possible location. A remote
control box is advised.
CAUTION
A minimum of 1.5" (3,8 cm) air gap between food­warmer and underside of shelf is required.
If shelf has rolled or flanged edges that create an overturned trough, mount Glo-Ray below lowest part of rolled or flanged edge, using the optional adjustable angle brackets (See Figure 6).
Figure 2. C-Leg Mounting
Figure 4. T-Leg End Mounting
Figure 5. T-Leg Alternate Mounting
Figure 3. Tubular Stand Mounting
Locking
screw
Glo-Ray®Food Warmer
4
POST MOUNT (Consult Factory)
DUAL MOUNTING
(see Figure 7)
Glo-Ray Warmers can be mounted side-by-side, providing a space of not less than 3" (7,6 cm) is maintained between units.
Factory ordered dual models are shipped with either a 3" or 6" (7,6 or 15,2 cm) wide spacer, with or with­out lights. These dual mount spacers are available for aluminum models only. Consult factory before installing warmers side-by-side without spacers.
CLEANING
WARNING
The appliance is not of jet-proof construction. Do not use jet-clean spray to clean this appliance.
To preserve the finish of your Glo-Ray Food Warmer it is recommended that exterior surfaces be wiped daily with a damp cloth. Stubborn stains may be removed with a good aluminum or stainless steel cleaner or a non-abrasive cleanser.
CAUTION: Use only non-abrasive cleaners. Abrasive cleaners could scratch the finish of the Foodwarmer marring its appearance and making it susceptible to soil accumulation.
Breath protectors may be removed for thorough cleaning and polishing. They should be wiped daily with a soft, damp cloth. If fine scratches are present a good acrylic cleaner may be used to polish the breath protectors and remove the scratches.
CAUTION: Only soft cleaning cloths should be used to clean breath protectors. Breath protectors are made of shatter-proof acrylic and will scratch if proper care is not taken.
DISPLAY LIGHT BULB REPLACEMENT
The display light is an incandescent bulb which illuminates the warming area. This bulb has a special coating to guard against injury and food contamination in the event of breakage.
To replace a bulb, disconnect the power supply and wait until the unit has cooled. Display lamps have a threaded base. Unscrew the bulb from the unit and replace it with a new specially coated incandescent bulb. Hatco Shatter-Resistant Bulbs meet NSF standards for food holding and display areas.
SAFETY PRECAUTIONS
Do not add a decorative soffit to hide a pass-through mounted Glo-Ray.
Use only recommended mounting methods and mate­rials and approved accessories to prevent personal injury or damage to the unit.
Be certain that specified safe and proper distances are maintained between the Glo-Ray and combustible wall or wall type surfaces and counters. See LOCATION.
CAUTION
Installation of two or more warmers with less than 3" (7.6 cm) between housings could result in premature failure of component parts.
6”
(15,2 cm)
3”
(7,6 cm)6”(15,2 cm)
6”
(15,2 cm)
6”
(15,2 cm)
6”
(15,2 cm)
15" (38 cm)
18" (45,7 cm)
Figure 6. Under Shelf Mounting
with Angle Brackets
Figure 7. Dual Mounting
DUAL WITH 3" (7,6 cm) SPACER
DUAL WITH 6" (15,2 cm) SPACER
Glo-Ray®Speisewärmer
5
ALLGEMEINES
Sicherheitsvorkehrungen in diesem Handbuch, denen die fettgedruckten Worte Warnung oder Vorsicht vorange-stellt sind, sind wichtig. Warnung weist auf mögliche Verletzungsgefahr für Sie oder andere Personen hin. Vorsicht macht auf eine mögliche Beschädigung des Geräts aufmerksam.
ELEKTRISCHE LEISTUNGSDATEN
GLO-RAY INFRAROT SPEISEWÄRMER
Glo-Ray Speisewärmer sind für 120, 220 oder 240 Volt lieferbar, je nach den Bestellanforderungen.
TRAGBARE SPEISEWÄRMER
Tragbare Speisewärmer sind für 120, 220 oder 240 Volt lieferbar.
* Markiert Modelle, die mehreren Speisepfannen Platz bieten: 76 cm=2 Pfannen, 107 cm=3 Pfannen, 137 cm=4 Pfannen, 168 cm=5 Pfannen.
**Beruht auf einer Standardbreite on 50 cm.
Gehäuse aus rostfreiem Stahl – 220-230 Volts
Hohe Standard
Modell Wattleistung Modell Wattleistung
GRH-24 546 GR-24 383 GRH-36 874 GR-36 628 GRH-48 1202 GR-48 874 GRH-60 1530 GR-60 1148 GRH-72 1913 GR-72 1394 GRH-96 2623 GR-96 1885
220-230V 230-240V
Modell Watt Amps Watt Amps
GR-B 273 1.30 250 1.04 GRFF 546 2.59 500 2.08 GRFFL 678 3.22 620 2.58 GRFFB 820 3.90 750 3.13 GRFFBL 951 4.52 870 3.63
FRITIERSTATION
220-230V 230-240V
Modell Watt Amps Watt Amps
GRFS-24 546 2.59 500 2.08 GRFSL-24 678 3.22 620 2.58 GRFSR-24 546 2.59 500 2.08 GRFSLR-24 131 0.62 120 5.00
BEHEIZTE REGALE
220-230V 230-240V
Modell Watt** Amps Watt** Amps
GRS-18 262 1.25 240 1.00 GRS-24 328 1.56 300 1.25 GRS-30* 404 1.92 370 1.54 GRS-36 481 2.29 440 1.83 GRS-42* 546 2.59 500 2.08 GRS-48 612 2.91 560 2.33 GRS-54* 700 3.33 640 2.67 GRS-60 765 3.64 700 2.92 GRS-66* 842 4.00 770 3.21 GRS-72 918 4.36 840 3.50
Gehäuse aus rostfreiem Stahl – 230-240 Volts
Hohe Standard
Modell Wattleistung Modell Wattleistung
GRH-24 500 GR-24 350 GRH-36 874 GR-36 575 GRH-48 1100 GR-48 800 GRH-60 1400 GR-60 1050 GRH-72 1750 GR-72 1275 GRH-96 2400 GR-96 1725
Aluminiumgehäuse – 220-230 Volts
Hohe Standard
Modell Wattleistung Modell Wattleistung
GRAH-18 383 GRA-18 273 GRAH-24 546 GRA-24 383 GRAH-30 721 GRA-30 492 GRAH-36 874 GRA-36 628 GRAH-42 1038 GRA-42 738 GRAH-48 1202 GRA-48 874 GRAH-54 1366 GRA-54 1011 GRAH-60 1530 GRA-60 1148 GRAH-66 1705 GRA-66 1268 GRAH-72 1885 GRA-72 1394 GRAH-84 2241 GRA-84 1639 GRAH-96 2623 GRA-96 1885
Aluminiumgehäuse – 230-240 Volts
Hohe Standard
Modell Wattleistung Modell Wattleistung
GRAH-24 500 GRA-24 350 GRAH-30 660 GRA-30 450 GRAH-36 800 GRA-36 575 GRAH-42 950 GRA-42 675 GRAH-48 1100 GRA-48 800 GRAH-54 1250 GRA-54 925 GRAH-60 1400 GRA-60 1050 GRAH-66 1560 GRA-66 1160 GRAH-72 1725 GRA-72 1275 GRAH-84 2050 GRA-84 1500 GRAH-96 2400 GRA-96 1725
Glo-Ray®Speisewärmer
6
Abbildung 1. Kettenaufhängung
ELEKTRISCHE ANFORDERUNGEN
Zur ordnungsgemäen Installation in Übereinstimmung mit dem örtlichen elektrischen Kode einen zugelasse­nen Elektriker zu Rate zu ziehen.
MODELLE MIT ANSCHLUKABEL UND STECKER
Für den Stecker der Modelle mit Anschlukabel und Stecker mu eine zugelassene geerdete Steckdose zur Verfügung stehen oder eingebaut werden.
PERMANENTER EINBAU
Dazu eine Stromleitung aus mindestens Nr. 10 Kupferdraht und mit einem Nennwert von 90°C (194°F) anbringen.
BEDIENUNGSSCHALTER
Wenn zwei oder mehrere Glo-Rays so aufgestellt sind, da die Wärme eines Gehäuses die Temperatur eines anderen erhöhen kann, müssen die Bedienungs-schalter in einem angemessenen Schaltkasten auerhalb des erwärmten Bereichs untergebracht werden. Glo-Rays, die als Teil einer Reihe von Speisewärmern bestellt werden, sollten keine eingebauten Schalter haben.
STANDORT
Zum sicheren und ordnungsgemäen Betrieb mu der Speisewärmer weit genug von brennbaren Wand- und Arbeitsoberflächen entfernt aufgestellt werden. Wenn angemessene Abstände eingehalten werden, wird die ideale Serviertemperatur der heien Speisen aufrecht erhalten ohne Qualitätsbeeinträchtigungen durch Überkochen.
HINWEIS: Glo-Ray ist nicht feuchtigkeitsbeständig. Das Gerät nicht über einer Dampftafel anbringen, es sei denn der Bedienungsschalter befindet sich an einem vom Gerät entfernten Ort.
WARNUNG
Dieses Gerät muß geerdet sein. Die Erdung muß von dem Netzanschluß ausgehen und mit dem ganzen Gerät verbunden sein.
WARNUNG
Die angegebenen Sicherheitsabstände zwischen dem Glo-Ray und brennbaren Wand- oder wandähnlichen Oberflächen und Arbeitsflächen aus Holz oder verfärbungsanfälligen Arbeitsflä­chen müssen eingehalten werden. Nichteinhaltung des Sicherheitsabstandes könnte zu Verfärbungen und Verbrennung führen.
GLO-RAY MIT STANDARD WATTLEISTUNG
Diese Glo-Rays so aufstellen, da ein Mindestabstand von 25 cm zwischen dem Boden des Glo-Ray und Arbeitsflächen aus Holz oder verfärbungsanfälligen Arbeitsflächen freibleibt.
GLO-RAY MIT HOHER WATTLEISTUNG
Diese Glo-Rays so aufstellen, da ein Mindestabstand von 34,3 cm zwischen dem Boden des Glo-Ray und Arbeitsflächen aus Holz oder ver­färbungsanfälligen Arbeitsflächen freibleibt.
AN KETTEN HÄNGENDE ODER WAND MON­TIERTE GLO-RAY MODELLE
Bei Glo-Rays, die an Ketten hängen oder mit einem Befestigungsbügel an der Wand montiert sind, einen Mindestabstand von 7,6 cm zu nichtmetallischen Wand- und anderen Oberflächen freilassen.
MONTIERUNG
ALLGEMEINES
Zur Aufhängung an einer Kette (Siehe Abbildung 1) oder unter einem Regal oder einer Durchreiche (Siehe Abbildung 6) werden die Glo-Rays mit 2 Aufhängern an beiden Enden geliefert. C-förmige Ständer, T-Stützen, Wandbefestigungs-bügel und Röhrenständer sind erhältlich. C-förmige Ständer und T-Stützen können an jedem Standard Glo-Ray Modell angebracht werden. Glo-Rays werden zur Aufstellung auf Röhrenständern vorbereitet wenn das bei der Bestellung gewünscht wird. Nur empfohlene Montierungsmethoden und anerkanntes Zubehör mit Ihrem Glo-Ray verwenden.
WARNUNG
Die Kette mu stark genug sein und sicher befestigt sein oder der Glo-Ray Speisewärmer kann sich lösen und möglicherweise Verletzungen oder Schäden am Gerät verursachen kann.
Zuleitungskette
Verbindungskette
minderstens
7,6 cm)
minderstens 25,4 cm
Standard Wattleistung minderstens 34,3 cm Hohe Wattleistung
Nichtmetallische Wandfläche
Nichtmetallische Oberfkäche
Glo-Ray®Speisewärmer
7
Verriegelungs-
schraube
Verstellbar
Nicht Verstellbar
EINBAU UNTER REGALEN
(Siehe Abbildungen 4 und 5)
Bei Einbau des Glo-Rays unter einem Regal, darauf achten, da die Schalter sich an einer möglichst kühlen Stelle befinden. Ein vom Gerät entfernt
befindlicher Schalterkasten wird empfohlen.
VORSICHT
Ein Luftspalt von mindestens 3,8 cm mu zwischen dem Speisewärmer und der Unterseite des Regales bestehen.
Wenn das Regal abgerundete Kanten oder Bordränder hat, die einen umgestülpten Trog formen, den Glo-Ray an der niedrigsten Stelle der Kante anbringen und dazu die wahlweise erhältlichen, verstellbaren Winkelbügel verwenden (Siehe Abbildung 6).
Abbildung 2. Montierung mit
einem C-förmigen Ständer
Abbildung 4. Montierung mit
einer End-T-Stütze
Abbildung 5. Alternative Montierung
mit einer T-Stütze
Abbildung 3. Montierung auf einem Röhrenständer
Stützschiene
Loading...
+ 19 hidden pages