Rampes Chauffantes Infra-Black
GRAIH and GRAIHL Series/Série
Installation and Operating Manual
Manuel d'installation et d'utilisation
®
GLO-RAY
Infra-Black Strip Heaters
P/N 07.04.556.00
Do not operate this equipment unless you
have read and understood the contents of
this manual! Failure to follow the
instructions contained in this manual may
result in serious injury or death. This
manual contains important safety
information concerning the maintenance,
use, and operation of this product. If
you’re unable to understand the contents
of this manual, please bring it to the
attention of your supervisor. Keep this
manual in a safe location for future
reference.
English = p 2
No opere este equipo al menos que haya
leído y comprendido el contenido de este
manual! Cualquier falla en el seguimiento
de las instrucciones contenidas en este
manual puede resultar en un serio lesión
o muerte. Este manual contiene
importante información sobre seguridad
concerniente al mantenimiento, uso y
operación de este producto. Si usted no
puede entender el contenido de este
manual por favor pregunte a su
supervisor. Almacenar este manual en
una localización segura para la referencia
futura.
Ne pas utiliser cet équipement sans avoir
lu et compris le contenu de ce manuel !
Le non-respect des instructions
contenues dans ce manuel peut entraîner
de graves blessures ou la mort. Ce
manuel contient des informations
importantes concernant l'entretien,
l'utilisation et le fonctionnement de ce
produit. Si vous ne comprenez pas le
contenu de ce manuel, veuillez le signaler
à votre supérieur. Conservez ce manuel
dans un endroit sûr pour pouvoir vous y
référer plus tard.
Electrical Wiring Information ..............................................13
IMPORTANT OWNER INFORMATION
Record the model number, serial number, voltage, and
purchase date of the unit in the spaces below (specification
label located on the side of the unit). Please have this
information available when calling Hatco for service assistance.
Model No. ________________________________________
Serial No. ________________________________________
Voltage __________________________________________
Date of Purchase __________________________________
Authorized Parts Distributors............................Back Cover
Business
Hours:7:00
Telephone: 800-558-0607; 414-671-6350
e-mail:partsandservice@hatcocorp.com
Fax:800-690-2966 (Parts and Service)
AM to 5:00 PM Central Standard Time (CST)
(Summer Hours: June to September—
7:00
AM to 5:00 PM CST Monday–Thursday
7:00
AM to 4:00 PM CST Friday)
414-671-3976 (International)
Register your unit!
Completing online warranty registration will prevent delay in
obtaining warranty coverage. Access the Hatco website at
www.hatcocorp.com, select the Parts & Service pull-down
menu, and click on “Warranty Registration”.
INTRODUCTION
Glo-Ray®Infra-Black®Strip Heaters ensure maximum food
holding time and minimize the risk of food-borne illness.
Optimum safety and quality is the result of food held at the
proper serving temperatures using Glo-Ray’s pre-focused heat
patterns. Glo-Ray Infra-Black emitters provide a solid panel of
uniform heat distribution that is ideal for limited space
operations.
The metal sheathed heating elements housed in the Infra-Black
emitters are guaranteed against burnout for two years.
Glo-Ray Infra-Black Strip Heaters are a product of extensive
research and field testing. The materials used were selected
for maximum durability, attractive appearance, and optimum
performance. Every unit is inspected and tested thoroughly
prior to shipment.
This manual provides the installation, safety, and operating
instructions for Glo-Ray Infra-Black Strip Heaters. Hatco
recommends all installation, operating, and safety instructions
appearing in this manual be read prior to installation or
operation of a unit.
Additional information can be found by visiting our web site at
www.hatcocorp.com.
b
d
tifie
n
e
id
l is
a
u
n
a
m
is
th
in
rs
a
e
p
p
t a
a
th
n
tio
a
rm
fo
in
ty
fe
Sa
the
WARNING indicates a hazardous situation which, if not
avoided, could result in death or serious injury.
CAUTION indicates a hazardous situation which, if not
avoided, could result in minor or moderate injury.
NOTICE is used to address practices not related to personal
injury.
fol
owi
l
ng
s
gnal
i
word
panel
:
s
y
2
Form No. GRAIHM-0815
English
WARNING
CAUTION
NOTICE
WARNING
IMPORTANT SAFETY INFORMATION
Read the following important safety information before using this equipment to avoid serious
injury or death and to avoid damage to equipment or property.
ELECTRIC SHOCK HAZARD:
• Units supplied without an electrical cord and plug
require a hardwired connection to the on-site electrical
system. Connection must be properly grounded and of
the correct voltage, size, and configuration for the
electrical specifications of the unit. Contact a qualified
electrician to determine and install the proper electrical
connection.
• Turn power OFF at fused disconnect switch/circuit
breaker and allow unit to cool before performing any
maintenance, adjustments, or cleaning.
• For hardwired units, all electrical connections must be
in accordance with local electrical codes and any other
applicable codes. Connections should be made by a
qualified, licensed electrician.
• DO NOT submerge or saturate with water. Unit is not
waterproof. Do not operate if unit has been submerged
or saturated with water.
• Unit is not weatherproof. Locate unit indoors where the
ambient air temperature is a minimum of 70°F (21°C).
• Do not steam clean or use excessive water on the unit.
• This unit is not “jet-proof” construction. Do not use jetclean spray to clean this unit.
• Do not clean unit when it is energized or hot.
• This unit must be serviced by qualified personnel only.
Service by unqualified personnel may lead to electric
shock or burn.
• Use only Genuine Hatco Replacement Parts when
service is required. Failure to use Genuine Hatco
Replacement Parts will void all warranties and may
subject operators of the equipment to hazardous
electrical voltage, resulting in electrical shock or burn.
Genuine Hatco Replacement Parts are specified to
operate safely in the environments in which they are
used. Some aftermarket or generic replacement parts
do not have the characteristics that will allow them to
operate safely in Hatco equipment.
FIRE HAZARD:
• Do not install unit above or around combustible
surfaces. Discoloration or combustion could occur.
Unit must be installed in non-combustible surroundings
only.
• Do not store or use gasoline or other flammable vapors
or liquids in the vicinity of this or any other appliance.
This unit has no “user-serviceable” parts. If service is
required on this unit, contact an Authorized Hatco Service
Agent or contact the Hatco Service Department at
414-671-6350; fax 414-671-3976.
Use only light bulbs that meet or exceed National
Sanitation Foundation (NSF) standards and are specifically
designed for food holding areas. Breakage of light bulbs
not specially coated could result in personal injury and/or
food contamination.
This unit is not intended for use by children or persons
with reduced physical, sensory, or mental capabilities.
Ensure proper supervision of children and keep them away
from the unit.
Make sure all operators have been instructed on the safe
and proper use of the unit.
For installation with chains, make sure the chains have
sufficient strength and are securely fastened to both the
strip heater and the mounting location. Poorly installed
chains may cause the heater to loosen and fall. Do not
place anything on top of heaters installed with chains.
BURN HAZARD: Some exterior surfaces on unit will get
hot. Avoid unnecessary contact with unit.
Standard and approved manufacturing oils may smoke up
to 30 minutes during initial startup. This is a temporary
condition. Operate unit without food product until smoke
dissipates.
Light-equipped strip heaters that require a circuit breaker
20 amps or larger must be installed with a remote control
enclosure containing a fuse rated at 20 amps or less for
the light circuit.
Ensure safe and proper operation. Refer to the “Minimum
Clearance Requirements” listed in the Installation section
of this manual.
Damage to countertop material such as Corian
products caused by heat generated from Hatco equipment
is not covered under the Hatco warranty. Contact the
manufacturer of the countertop material for application
information.
Remote mounted control boxes must be installed outside
strip heater heat zone to prevent premature failure of
components due to excessive heat.
Installation of two or more separate units with less than 3″
(76 mm) between housings may result in premature failure
of component parts. Failure to provide proper spacing may
result in heat damage to electrical components and are not
covered by warranty.
Use non-abrasive cleaners only. Abrasive cleaners could
scratch the finish of the unit, marring its appearance and
making it susceptible to soil accumulation.
®
and similar
Form No. GRAIHM-0815
3
MODEL DESCRIPTION
.
.
G R A I H L - XX D
Glo-Ray
Aluminum
Incandescent Light
D = Dual Elements
No Character = Single Element
Width (in inches)
High Wattage
Infra-Black Emitter
All Models
Glo-Ray®Infra-Black®Strip Heaters are perfect for foodwarming
at a close range to food product. Heat from a metal sheathed
heating element housed inside an Infra-Black emitter is
distributed evenly throughout the entire surface area of the
emitter. The emitter gives off a solid panel of heat downward
onto the food product.
Glo-Ray Infra-Black Strip Heaters are constructed with
aluminum housings in lengths of 18″ (457 mm) to
72″ (1829 mm).
Dual models allow for side-by-side mounting of two heating
elements to provide a wider holding area. Dual models are
constructed with a standard 3″ (76 mm) or optional
6″ (152 mm) spacer between heating elements.
Glo-Ray Infra-Black Strip Heaters have several mounting
options and switch locations. A thermostatic control box with
indicator lights (TCBI) can be mounted on the unit with a
thermostatic control, ON/OFF (I/O) toggle switch, and an
indicator light. Remote control enclosure(s) (RMBs) can be
configured with infinite control(s), ON/OFF (I/O) toggle
switch(es), and/or indicator light(s). Units are available in
several optional Designer colors and gloss finishes.
GRAIH-XX:Aluminum housing, single element
GRAIHL-XX:Aluminum housing, incandescent lights,
single element
GRAIH-XXD:Aluminum housing, dual element
GRAIHL-XXD: Aluminum housing, incandescent lights,
dual elements
English
GRAIHL-XX Model
GRAIH-XXD Model with TCBI
MODEL DESIGNATION
GRAIH-XX Model with TCBI
4
GRAIHL-XXD Model
Form No. GRAIHM-0815
English
Electrical Rating Chart — GRAIH-XX Models
ModelVoltageWattsAmpsShipping Weight
GRAIH-181203502.96 lbs. (3 kg)
08
2
2403501.56 lbs. (3 kg)
2203501.66 lbs. (3 kg)
2403501.56 lbs. (3 kg)
220–230 (CE)350–3831.6–1.76 lbs. (3 kg)
230–240 (CE)321–3501.4–1.56 lbs. (3 kg)
RAIH-24
G
RAIH-301206605.513 lbs. (6 kg)
G
GRAIH-361208006.715 lbs. (7 kg)
GRAIH-421209507.917 lbs. (8 kg)
20
1
085002.411 lbs. (5 kg)
2
405002.111 lbs. (5 kg)
2
2205002.311 lbs. (5 kg)
2405002.111 lbs. (5 kg)
220–230 (CE)500–5462.3–2.411 lbs. (5 kg)
230–240 (CE)459–5002.0–2.111 lbs. (5 kg)
086603.213 lbs. (6 kg)
2
2406602.813 lbs. (6 kg)
2206603.013 lbs. (6 kg)
2406602.813 lbs. (6 kg)
220–230 (CE)660–7213.0-3.113 lbs. (6 kg)
230–240 (CE)606–6602.6-2.813 lbs. (6 kg)
088003.815 lbs. (7 kg)
2
2408003.315 lbs. (7 kg)
2208003.615 lbs. (7 kg)
2408003.315 lbs. (7 kg)
220–230 (CE)800–8743.6–3.815 lbs. (7 kg)
230–240 (CE)734–8003.2–3.315 lbs. (7 kg)
2089504.617 lbs. (8 kg)
2409504.017 lbs. (8 kg)
2209504.317 lbs. (8 kg)
2409504.017 lbs. (8 kg)
220–230 (CE)950–10384.3–4.517 lbs. (8 kg)
230–240 (CE)872–9503.8–4.017 lbs. (8 kg)
50
3
00
5
.7
1
.2
4
lbs. (3 kg)
6
1 lbs. (5 kg)
1
SPECIFICATIONS
ModelVoltageWattsAmpsShipping Weight
GRAIH-4812011009.221 lbs. (10 kg)
08
2
24011004.621 lbs. (10 kg)
22011005.021 lbs. (10 kg)
24011004.621 lbs. (10 kg)
220–230 (CE)1100–12025.0–5.221 lbs. (10 kg)
230–240 (CE)1010–11004.4-4.621 lbs. (10 kg)
GRAIH-54120125010.424 lbs. (11 kg)
GRAIH-60120140011.727 lbs. (12 kg)
GRAIH-66120†156013.030 lbs. (14 kg)
GRAIH-72120†172514.433 lbs. (15 kg)
20812506.024 lbs. (11 kg)
4012505.224 lbs. (11 kg)
2
22012505.724 lbs. (11 kg)
24012505.224 lbs. (11 kg)
220–230 (CE)1250–13665.7–5.924 lbs. (11 kg)
230–240 (CE)1148–12505.0–5.224 lbs. (11 kg)
0814006.727 lbs. (12 kg)
2
4014005.827 lbs. (12 kg)
2
22014006.427 lbs. (12 kg)
40
2
220–230 (CE)1400–15306.4–6.727 lbs. (12 kg)
30–240 (CE)1286–14005.6–5.8
2
20815607.530 lbs. (14 kg)
24015606.530 lbs. (14 kg)
22015607.130 lbs. (14 kg)
24015606.530 lbs. (14 kg)
220–230 (CE)1560–17057.1–7.430 lbs. (14 kg)
230–240 (CE)1433–15606.2–6.530 lbs. (14 kg)
20817258.333 lbs. (15 kg)
24017257.233 lbs. (15 kg)
22017257.833 lbs. (15 kg)
24017257.233 lbs. (15 kg)
220–230 (CE)1725–18857.8–8.233 lbs. (15 kg)
230–240 (CE)1584–17256.9–7.233 lbs. (15 kg)
1
1
100
400
.3
5
.8
5
1 lbs. (10 kg)
2
7 lbs. (12 kg)
2
7 lbs. (12 kg)
2
The shaded areas contain electrical information for
International models only.
NOTE: Shipping weight does not include remote control
enclosure. Add 2–8 lbs. (1–3 kg) to shipping weight
depending on size of remote control enclosure.
Form No. GRAIHM-0815
† Infinite control not available.
5
SPECIFICATIONS
CAUTION
Electrical Rating Chart — GRAIHL-XX Models
English
ModelVoltageWattsAmpsShipping Weight
RAIHL-18
G
RAIHL-24
G
GRAIHL-301207806.517 lbs. (8 kg)
GRAIHL-361209808.220 lbs. (9 kg)
GRAIHL-4212011309.423 lbs. (10 kg)
20
1
120/2084702.712 lbs. (5 kg)
120/2404702.512 lbs. (5 kg)
2204502.012 lbs. (5 kg)
2404702.012 lbs. (5 kg)
20–230 (CE)450–4922.0–2.1
2
30–240 (CE)432–4701.9–2.0
2
20
1
120/2086203.415 lbs. (7 kg)
120/2406203.115 lbs. (7 kg)
20
2
2406202.615 lbs. (7 kg)
220–230 (CE)600–6562.7–2.915 lbs. (7 kg)
230–240 (CE)569–6202.5–2.615 lbs. (7 kg)
20/2087804.217 lbs. (8 kg)
1
120/2407803.817 lbs. (8 kg)
2207603.517 lbs. (8 kg)
2407803.317 lbs. (8 kg)
20–230 (CE)760–8313.5–3.6
2
230–240 (CE)716–7803.1–3.317 lbs. (8 kg)
20/2089805.320 lbs. (9 kg)
1
120/2409804.820 lbs. (9 kg)
20
2
2409804.120 lbs. (9 kg)
220–230 (CE)950–10384.3–4.520 lbs. (9 kg)
230–240 (CE)900–9803.9–4.120 lbs. (9 kg)
120/20811306.123 lbs. (10 kg)
120/24011305.523 lbs. (10 kg)
22011005.023 lbs. (10 kg)
24011304.723 lbs. (10 kg)
220–230 (CE)1100–12025.0–5.223 lbs. (10 kg)
230–240 (CE)1038–11304.5–4.723 lbs. (10 kg)
70
4
20
6
00
6
50
9
.9
3
.2
5
.7
2
.3
4
2 lbs. (5 kg)
1
2 lbs. (5 kg)
1
2 lbs. (5 kg)
1
5 lbs. (7 kg)
1
5 lbs. (7 kg)
1
7 lbs. (8 kg)
1
0 lbs. (9 kg)
2
ModelVoltageWattsAmpsShipping Weight
GRAIHL-48120134011.226 lbs. (12 kg)
120/20813407.326 lbs. (12 kg)
120/24013406.626 lbs. (12 kg)
20
2
24013405.626 lbs. (12 kg)
220–230 (CE)1300–14215.9–6.226 lbs. (12 kg)
30–240 (CE)1231–13405.4–5.6
2
GRAIHL-54120149012.429 lbs. (13 kg)
GRAIHL-60120170014.233 lbs. (15 kg)
RAIHL-66120†186015.534 lbs. (15 kg)
G
GRAIHL-72120*208517.436 lbs. (16 kg)
20/20814908.029 lbs. (13 kg)
1
120/24014907.229 lbs. (13 kg)
22014506.629 lbs. (13 kg)
40
2
220–230 (CE)1450–15856.6–6.929 lbs. (13 kg)
230–240 (CE)1368–14905.9–6.229 lbs. (13 kg)
120/20817009.233 lbs. (15 kg)
20/24017008.333 lbs. (15 kg)
1
22016507.533 lbs. (15 kg)
24017007.133 lbs. (15 kg)
220–230 (CE)1650–18037.5–7.833 lbs. (15 kg)
30–240 (CE)1561–17006.8–7.1
2
120/208186010.034 lbs. (15 kg)
20/24018609.034 lbs. (15 kg)
1
22018108.234 lbs. (15 kg)
24018607.834 lbs. (15 kg)
220–230 (CE)1810–19788.2–8.634 lbs. (15 kg)
230–240 (CE)1708–18607.1–7.834 lbs. (15 kg)
120/208208511.336 lbs. (16 kg)
120/240208510.236 lbs. (16 kg)
22020259.236 lbs. (16 kg)
24020858.736 lbs. (16 kg)
220–230 (CE)2025–22139.2–9.636 lbs. (16 kg)
230–240 (CE)1915–20858.3–8.736 lbs. (16 kg)
300
1
490
1
.9
5
.2
6
6 lbs. (12 kg)
2
6 lbs. (12 kg)
2
9 lbs. (13 kg)
2
3 lbs. (15 kg)
3
The shaded areas contain electrical information for
International models only.
NOTE: GRAIHL-XX models that have multiple voltages listed,
such as 120/208 or 120/240, have multiple internal
circuits. For example a 120/208 volt unit utilizes 120
volts for light circuit and 208 volts for the heat circuit(s).
Consult the Electrical Diagram supplied with the unit for
specific information.
NOTE: Shipping weight does not include remote control
enclosure. Add 2–8 lbs. (1–3 kg) to shipping weight
depending on size of remote control enclosure.
Light-equipped strip heaters that require a circuit breaker
20 amps or larger must be installed with a remote control
enclosure containing a fuse rated at 20 amps or less for the
light circuit.
† Infinite control not available.
* Only available with remote control enclosure options.
6
Form No. GRAIHM-0815
English
Electrical Rating Chart — GRAIH-XXD Models
SPECIFICATIONS
ModelVoltageWattsAmpsShipping Weight
RAIH-18D
G
GRAIH-24D12010008.319 lbs. (9 kg)
GRAIH-30D120132011.021 lbs. (10 kg)
GRAIH-36D120160013.324 lbs. (11 kg)
GRAIH-42D120190015.827 lbs. (12 kg)
20
1
2087003.413 lbs. (6 kg)
2407002.913 lbs. (6 kg)
2207003.213 lbs. (6 kg)
2407002.913 lbs. (6 kg)
20–230 (CE)700–7653.2–3.3
2
230–240 (CE)643–7002.8–2.913 lbs. (6 kg)
20810004.819 lbs. (9 kg)
4010004.219 lbs. (9 kg)
2
22010004.519 lbs. (9 kg)
24010004.219 lbs. (9 kg)
220–230 (CE)1000–10934.5–4.719 lbs. (9 kg)
30–240 (CE)918–10004.0–4.2
2
20813206.321 lbs. (10 kg)
24013205.521 lbs. (10 kg)
22013206.021 lbs. (10 kg)
40
2
220–230 (CE)1320–14436.0–6.321 lbs. (10 kg)
230–240 (CE)1212–13205.3–5.521 lbs. (10 kg)
0816007.724 lbs. (11 kg)
2
4016006.724 lbs. (11 kg)
2
22016007.324 lbs. (11 kg)
24016006.724 lbs. (11 kg)
220–230 (CE)1600–17497.3–7.624 lbs. (11 kg)
230–240 (CE)1469–16006.4–6.724 lbs. (11 kg)
20819009.127 lbs. (12 kg)
24019007.927 lbs. (12 kg)
22019008.627 lbs. (12 kg)
24019007.927 lbs. (12 kg)
220–230 (CE)1900–20778.6–9.027 lbs. (12 kg)
230–240 (CE)1745–19007.6–7.927 lbs. (12 kg)
00
7
320
1
.8
5
.5
5
3 lbs. (6 kg)
1
3 lbs. (6 kg)
1
9 lbs. (9 kg)
1
1 lbs. (10 kg)
2
The shaded areas contain electrical information for
International models only.
ModelVoltageWattsAmpsShipping Weight
GRAIH-48D120*220018.332 lbs. (15 kg)
208220010.632 lbs. (15 kg)
24022009.232 lbs. (15 kg)
20
2
24022009.232 lbs. (15 kg)
220–230 (CE)2200–2405 10.0–10.532 lbs. (15 kg)
30–240 (CE)2020–22008.8–9.2
2
RAIH-54D
G
GRAIH-60D120*280023.339 lbs. (18 kg)
GRAIH-66D120*312026.042 lbs. (19 kg)
GRAIH-72D120*345028.846 lbs. (21 kg)
20*
1
208250012.035 lbs. (16 kg)
240250010.435 lbs. (16 kg)
20
2
240250010.435 lbs. (16 kg)
220–230 (CE)2500–2733 11.4–11.935 lbs. (16 kg)
230–240 (CE)2296–2500 10.0–10.435 lbs. (16 kg)
208280013.539 lbs. (18 kg)
40280011.739 lbs. (18 kg)
2
220280012.739 lbs. (18 kg)
240280011.739 lbs. (18 kg)
220–230 (CE)2800–3060 12.7–13.339 lbs. (18 kg)
230–240 (CE)2571–2800 11.2–11.739 lbs. (18 kg)
208312015.042 lbs. (19 kg)
240312013.042 lbs. (19 kg)
20
2
240312013.042 lbs. (19 kg)
220–230 (CE)3120–3410 14.2–14.842 lbs. (19 kg)
230–240 (CE)2865–3120 12.5–13.042 lbs. (19 kg)
240345014.446 lbs. (21 kg)
220345015.746 lbs. (21 kg)
240345014.446 lbs. (21 kg)
220–230 (CE)3450–3771 15.7–16.446 lbs. (21 kg)
230–240 (CE)3168–3450 13.8–14.446 lbs. (21 kg)
2
2
2
3
200
500
500
120
0.0
1
0.8
2
1.4
1
4.2
1
2 lbs. (15 kg)
3
2 lbs. (15 kg)
3
5 lbs. (16 kg)
3
5 lbs. (16 kg)
3
2 lbs. (19 kg)
4
* Only available with remote control enclosure options.
NOTE: Shipping weight does not include remote control
enclosure. Add 2–8 lbs. (1–3 kg) to shipping weight
depending on size of remote control enclosure.
Form No. GRAIHM-0815
7
SPECIFICATIONS
CAUTION
Electrical Rating Chart — GRAIHL-XXD Models
English
ModelVoltageWattsAmpsShipping Weight
RAIHL-18D
G
GRAIHL-24D12011209.321 lbs. (10 kg)
RAIHL-30D120144012.023 lbs. (10 kg)
G
GRAIHL-36D120178014.827 lbs. (12 kg)
GRAIHL-42D120208017.330 lbs. (14 kg)
20
1
20/208
1
120/2408203.918 lbs. (8 kg)
2208003.618 lbs. (8 kg)
40
2
220–230 (CE)800–8753.6–3.818 lbs. (8 kg)
230–240 (CE)753–8203.3–3.418 lbs. (8 kg)
120/20811205.821 lbs. (10 kg)
120/24011205.221 lbs. (10 kg)
22011005.021 lbs. (10 kg)
24011204.721 lbs. (10 kg)
220–230 (CE) 1100–12035.0–5.221 lbs. (10 kg)
30–240 (CE)1029–11204.5–4.7
2
120/20814407.323 lbs. (10 kg)
120/24014406.523 lbs. (10 kg)
20
2
24014406.023 lbs. (10 kg)
220–230 (CE) 1420–15536.5–6.823 lbs. (10 kg)
230–240 (CE) 1323–14405.8–6.023 lbs. (10 kg)
120/20817809.227 lbs. (12 kg)
20/24017808.227 lbs. (12 kg)
1
20
2
24017807.427 lbs. (12 kg)
220–230 (CE) 1750–19148.0–8.327 lbs. (12 kg)
230–240 (CE) 1635–17807.1–7.427 lbs. (12 kg)
120/208208010.630 lbs. (14 kg)
120/24020809.430 lbs. (14 kg)
22020509.330 lbs. (14 kg)
24020808.730 lbs. (14 kg)
220–230 (CE) 2050–22429.3–9.730 lbs. (14 kg)
230–240 (CE) 1910–20808.3–8.730 lbs. (14 kg)
20
8
20
8
20
8
420
1
750
1
.8
6
.4
4
.4
3
.5
6
.0
8
8 lbs. (8 kg)
1
8 lbs. (8 kg)
1
8 lbs. (8 kg)
1
1 lbs. (10 kg)
2
3 lbs. (10 kg)
2
7 lbs. (12 kg)
2
ModelVoltageWattsAmpsShipping Weight
RAIHL-48D
G
RAIHL-54D
G
GRAIHL-60D120*310025.842 lbs. (19 kg)
GRAIHL-66D120*342028.544 lbs. (20 kg)
GRAIHL-72D220375017.048 lbs. (22 kg)
20*
1
120/208244012.635 lbs. (16 kg)
120/240244011.235 lbs. (16 kg)
220240010.935 lbs. (16 kg)
240244010.235 lbs. (16 kg)
20–230 (CE)2400–262510.9–11.4
2
230–240 (CE) 2241–2440 9.7–10.235 lbs. (16 kg)
20*
1
120/208274014.038 lbs. (17 kg)
120/240274012.238 lbs. (17 kg)
20
2
240274011.438 lbs. (17 kg)
220–230 (CE) 2700–2953 12.3–12.838 lbs. (17 kg)
30–240 (CE)2516–274010.9–11.4
2
20/208310016.042 lbs. (19 kg)
1
120/240310014.242 lbs. (19 kg)
220305013.942 lbs. (19 kg)
240310012.942 lbs. (19 kg)
220–230 (CE) 3050–3336 13.9–14.542 lbs. (19 kg)
230–240 (CE) 2847–3100 12.4–12.942 lbs. (19 kg)
120/240342015.544 lbs. (20 kg)
220337015.344 lbs. (20 kg)
240342014.344 lbs. (20 kg)
20–230 (CE)3370–368515.3–16.0
2
230–240 (CE) 3141–3420 13.7–14.344 lbs. (20 kg)
240381015.948 lbs. (22 kg)
220–230 (CE) 3750–4101 17.0–17.848 lbs. (22 kg)
230–240 (CE) 3498–3810 15.8–15.948 lbs. (22 kg)
440
2
740
2
700
2
0.3
2
2.8
2
2.3
1
5 lbs. (16 kg)
3
5 lbs. (16 kg)
3
8 lbs. (17 kg)
3
8 lbs. (17 kg)
3
8 lbs. (17 kg)
3
4 lbs. (20 kg)
4
* Only available with remote control enclosure options.
The shaded areas contain electrical information for
International models only.
NOTE: GRAIHL-XXD models that have multiple voltages
listed, such as 120/208 or 120/240, have multiple
internal circuits. For example a 120/208 volt unit utilizes
120 volts for light circuit and 208 volts for the heat
circuit(s). Consult the Electrical Diagram supplied with
the unit for specific information.
NOTE: Shipping weight does not include remote control
enclosure. Add 2–8 lbs. (1–3 kg) to shipping weight
depending on size of remote control enclosure.
Light-equipped strip heaters that require a circuit breaker
20 amps or larger must be installed with a remote control
enclosure containing a fuse rated at 20 amps or less for
the light circuit.
8
Form No. GRAIHM-0815
English
A
D
C
B
Front View — Model GRAIHL-XXD
Bottom View — Model GRAIHL-XXD
A
D
C
B
Front View — Model GRAIH-XXD
Bottom View — Model GRAIH-XXD
A
D
C
B
Front View — Model GRAIH-XX
Bottom View — Model GRAIH-XX
A
D
C
B
Front View — Model GRAIHL-XX
Bottom View — Model GRAIHL-XX
E
E
E
E
Dimensions
SPECIFICATIONS
Width
Model
GRAIH-XX
GRAIHL-XX
GRAIH-XXD
GRAIHL-XXD
Add 3″ (76 mm) to Depth (B) and Depth (C) if unit is configured with an optional 6″ (152 mm) spacer.
NOTE: Depth (C) dimension includes TCBI box.
(A)
18″–72″
(457–1829 mm)6″(152 mm)9″(229 mm)
18″–72″
(457–1829 mm)
18″–72″
(457–1829 mm)
18″–72″
(457–1829 mm)
Depth
(B)
9″
(229 mm)
15″
(381 mm)
15″
(381 mm)
Depth
(C)
12″
(305 mm)
18″
(457 mm)
18″
(457 mm)
Height
(D)
2-5/8″
(66 mm)
2-5/8″
(66 mm)
2-5/8″
(66 mm)
2-5/8″
(66 mm)
Width
(E)
8″
(203 mm)
8″
(203 mm)
8″
(203 mm)
8″
(203 mm)
Form No. GRAIHM-0815
9
INSTALLATION
NOTICE
CAUTION
WARNING
NOTICE
English
General
Use the information in this section to prepare for and install an
Infra-Black
information for the type of installation. Infra-Black Strip Heaters
are shipped with most components pre-assembled. Dual units
are supplied with a required 3″ (76 mm) or 6″ (152 mm) spacer
pre-assembled at the factory.
ELECTRIC SHOCK HAZARD: Unit is not weatherproof.
Locate the unit indoors where the ambient air temperature
is a minimum of 70°F (21°C).
FIRE HAZARD: Do not install unit above or around
combustible surfaces. Discoloration or combustion could
occur. Unit must be installed in non-combustible
surroundings only.
Ensure safe and proper operation. Refer to the “Minimum
Clearance Requirements” listed in the Installation section
of this manual.
Damage to countertop material such as Corian
products caused by heat generated from Hatco equipment
is not covered under the Hatco warranty. Contact the
manufacturer of the countertop material for application
information.
NOTE: Contact the countertop manufacturer of the base
1. Remove the unit from the shipping carton and remove all
NOTE: To prevent delay in obtaining warranty coverage,
2. Remove tape and protective packaging from all surfaces of
NOTE: If the unit is configured with optional equipment, see
3. Refer to the appropriate mounting procedure in this section
®
Strip Heater. Make sure to locate the specific
®
and similar
material for application information and surface
temperature limits before installing the unit.
packing materials.
complete online warranty registration. See the
IMPORTANT OWNER INFORMATION section for
details.
the unit.
the OPTIONSANDACCESSORIES section in this
manual.
for the desired mounting style.
Dual Mounting
When mounting units side-by-side, a space not less than
3” (76 mm) must be maintained between units. Dual units
ordered from the factory are shipped with a pre-assembled
3” (76 mm) or 6” (152 mm) spacer.
Installation of two or more separate units with less than 3″
(76 mm) between housings may result in premature failure
of component parts. Failure to provide proper spacing may
result in heat damage to electrical components and are not
covered by warranty.
Under Shelf Mounting
When mounting a unit under a shelf, use adjustable angle
brackets to assure proper spacing. Remote control enclosures
are recommended to keep switches out of the heat zone and
prevent premature failure.
Pass-Through
If pass-through area is under 9 1/2″ (241 mm) deep, a single
unit can be used. For a 10″ to 19″ (254 to 483 mm) deep passthrough area, a dual unit is recommended. Installation of
multiple units must have a minimum spacing of 3″ (76 mm)
between strip heaters.
Over Steam Table
When mounting over a steam table, a remote control enclosure
must be installed.
10
Form No. GRAIHM-0815
English
Overshelf
Counter
10”
(254 mm)
C
Pass-Through Shelf
Back Wall
Counter
A
B
4″–10″
(102–254 mm)
9-1/2″
(241 mm)
6″
(152 mm)
22″
(559 mm)
8″–14″
(203–356 mm)
18″
(457 mm)
19″
(483 mm)
15″
(381 mm)
8″–14″
(203–356 mm)
INSTALLATION
Minimum Clearance Requirements
ModelsABC
GRAIH and GRAIHL4"■1"
with TCBI(102 mm)(25 mm)
GRAIH and GRAIHL4"3"0"
with RMB(102 mm)(76 mm)(0 mm)
GRAIH-XXD and 8"■1"
GRAIHL-XXD with TCBI(203 mm)(25 mm)
GRAIH-XXD and 8"3"0"
GRAIHL-XXD with RMB(203 mm)(76 mm)(0 mm)
Minimum Clearance Requirements
■ Must be a pass-through application, not allowed with back
wall installation.
Maximum Overshelf Clearance Requirements
Units should be mounted at a maximum distance of 10”
(254 mm) from the front of an overshelf.
Recommended Mounting Heights
Recommended Element Height
for GRAIH-XX and GRAIHL-XX models
Form No. GRAIHM-0815
Maximum Overshelf Clearance Requirements
GRAIH-XXD and GRAIHL-XXD models with a 3″ (76 mm) spacer
Recommended Element Height for
Recommended Element Height for
GRAIH-XXD and GRAIHL-XXD models with a 6″ (152 mm) spacer
11
INSTALLATION
Tubular
Stand
Angled
End Bracket
End Bracket
Screws
Tubular Stand
Screws
CAUTION
1″ (25 mm)
Gap
Minimum
Shelf with 3/4″ (19 mm)
flanged edge
Adjustable
Angle
Bracket
CAUTION
Removed
Hanger Tabs
and Screws
Adjustable
Angle Bracket
End Plate
Screws
English
Tubular Stand Mounting
Mounting a unit with non-adjustable tubular stands permanently
attaches the unit to a countertop or serving table.
Ensure safe and proper operation. Refer to the “Minimum
Clearance Requirements” listed in the Installation section
of this manual.
Tubular stands are available in aluminum, Designer colors, or
gloss finishes in heights of 4″ to 14″ (102 to 356 mm) in
2” (51 mm) increments.
NOTE: Tubular stands cannot be retrofitted in the field.
1. Position the unit upside-down on a flat surface.
NOTE: Units for this application are supplied with the conduit
attached to one side of the unit. Conduit should not be
removed.
2. Secure the top of the tubular stand to the bottom of the
angled end bracket using the screws supplied.
3. Secure the angled end bracket to the end plate of the unit
with the previously removed hanger tab screws.
4. Repeat steps 2 and 3 on the opposite end of the unit.
5. Secure the stands to the mounting surface using
appropriate fasteners.
NOTE: Two pairs of tubular stands will be needed for mounting
dual units.
Angle Bracket Mounting
Mounting a unit with an angle bracket permanently attaches the
unit to the underside of a shelf. It can be mounted to a flat shelf
or a shelf with rolled/flanged edges. The adjustable angle
brackets will provide the necessary gap between the unit and
a combustible shelf.
If the shelf has a rolled or flanged edge, use the optional
adjustable angle brackets to mount the unit below the lowest
part of the rolled or flanged edge of the shelf (a minimum gap
of 1″ [25 mm] is required between the unit and the underside of
a rolled or flanged edge of the shelf to prevent heat damage to
the electrical system of the unit).
Ensure safe and proper operation. Refer to the “Minimum
Clearance Requirements” listed in the Installation section
of this manual.
NOTE: When mounting the unit under a shelf, it is
recommended to use a remote control enclosure.
Tubular Stand Mounting
Flanged Edge Shelf Installation
1. Position the unit on a flat surface with the heating element
facing down.
2. Remove the two hanger tab screws and hanger tabs.
These items will not be needed.
3. Remove the two upper end plate screws.
4. Align the adjustable angle bracket to the end plate
mounting holes of the unit. Secure angle bracket with
previously removed end plate screws.
Adjustable Angle Bracket Installation
12
Form No. GRAIHM-0815
Loading...
+ 28 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.