Hatco FSHC-17W1D Installation Manual

Register Online!
hatcocorp.com
WARNING
ADVERTENCIA
AVERTISSEMENT
(see page 2)
S'inscrire en ligne!
(voir page 18)
®
FLAV-R-SAVOR
Tall Humidified Holding Cabinets
Grandes armoires de conservation avec
ajout d'humidité
FSHC-12W1, FSHC-12W2, FSHC-17W1,
and FSHC-17W2 Series/Série
Installation and Operating Manual
I&W#07.05.169.00
Do not operate this equipment unless you have read and understood the contents of this manual! Failure to follow the instructions contained in this manual may result in serious injury or death. This manual contains important safety information concerning the maintenance, use, and operation of this product. If you’re unable to understand the contents of this manual, please bring it to the attention of your supervisor. Keep this manual in a safe location for future reference.
English = p 2
No opere este equipo al menos que haya leído y comprendido el contenido de este manual! Cualquier falla en el seguimiento de las instrucciones contenidas en este manual puede resultar en un serio lesión o muerte. Este manual contiene importante información sobre seguridad concerniente al mantenimiento, uso y operación de este producto. Si usted no puede entender el contenido de este manual por favor pregunte a su supervisor. Almacenar este manual en una localización segura para la referencia futura.
Ne pas utiliser cet équipement sans avoir lu et compris le contenu de ce manuel ! Le non-respect des instructions contenues dans ce manuel peut entraîner de graves blessures ou la mort. Ce manuel contient des informations importantes concernant l'entretien, l'utilisation et le fonctionnement de ce produit. Si vous ne comprenez pas le contenu de ce manuel, veuillez le signaler à votre supérieur. Conservez ce manuel dans un endroit sûr pour pouvoir vous y référer plus tard.
Français = p 18
© 2015 Hatco Corporation
NOTICE
CAUTION
WARNING
24 Hour 7 Day Parts and Service Assistance available in the United States and Canada by calling 800-558-0607.
CONTENTS
English
Important Owner Information ..............................................2
Introduction...........................................................................2
Important Safety Information...............................................3
Model Description.................................................................4
Model Designation................................................................5
Specifications........................................................................5
Plug Configuration...............................................................5
Electrical Rating Chart ........................................................5
Dimensions .........................................................................6
Installation.............................................................................8
General ...............................................................................8
Reversing the Access Door.................................................9
IMPORTANT OWNER INFORMATION
Record the model number, serial number, voltage, and purchase date of the unit in the spaces below (specification label located on the right side of the unit when facing controls). Please have this information available when calling Hatco for service assistance.
Model No. ________________________________________
Serial No. ________________________________________
Voltage __________________________________________
Date of Purchase __________________________________
Operation.............................................................................10
General .............................................................................10
Setting the Air Temperature ...............................................11
Setting the Humidity Level.................................................11
Food Holding Guide...........................................................11
Maintenance ........................................................................12
General .............................................................................12
Daily Cleaning ...................................................................12
Cleaning/Draining the Water Pan......................................13
Removing Lime and Mineral Deposits...............................13
Troubleshooting Guide ......................................................14
Options and Accessories...................................................15
Limited Warranty.................................................................17
Authorized Parts Distributors............................Back Cover
Business Hours: 7:00
Telephone: 800-558-0607; 414-671-6350
E-mail: partsandservice@hatcocorp.com
Fax: 800-690-2966 (Parts and Service)
AM to 5:00 PM Central Standard Time (CST)
(Summer Hours: June to September 7:00
AM to 5:00 PM CST Monday–Thursday
7:00
AM to 4:00 PM CST Friday)
414-671-3976 (International)
Register your unit!
Completing online warranty registration will prevent delay in obtaining warranty coverage. Access the Hatco website at www.hatcocorp.com, select the Parts & Service pull-down menu, and click on “Warranty Registration”.
INTRODUCTION
Hatco Flav-R-Savor®Tall Humidified Holding Cabinets are designed to hold prepared foods for prolonged periods of time while maintaining that “just-made” quality. Hatco Holding Cabinets provide the best environment for food products by regulating the air temperature while at the same time balancing the humidity level.
Flav-R-Savor air flow pattern is designed to maintain consistent cabinet temperature without drying out foods. The precise combination of heat and humidity creates a “blanket” effect around the food. The air flow rate enables the cabinet to rapidly recover temperature after opening and closing the door.
The use of controlled, moisturized heat maintains serving temperature and texture longer than conventional dry holding equipment.
Flav-R-Savor Tall Humidified Holding Cabinets are products of extensive research and field testing. The materials used were selected for maximum durability, attractive appearance, and optimum performance. Every unit is inspected and tested thoroughly prior to shipment.
Additional information can be found by visiting our web site at www.hatcocorp.com.
tin
a
r
e
p
o
d
n
ty, a
fe
, sa
n
tio
lla
sta
in
e
s th
e
vid
o
r
l p
a
u
n
is ma
Th i H i or operation of the unit.
Safety information that appears in this manual is identified by the following signal word panels:
WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE is used to address practices not related to personal injury.
ns
nst
ons
ti
ruc
t
e
r
tco
a
ons
i
ruct
or
f mme
co
appeari
Fl
a
n
av
d
s a
ng
-R-S ll in
n
i
av
s
hi
t
al
T
or
lla
sta
manual
Hum
l
tio
n
, o
be
i
f
di
i
e
p
read
ed
r
ng
di
Hol
, a
g
tin
a
o
t
or
pri
n nst
i
Cabi
sa
d
al
l
at
net. fe
on
i
g
ty
2
Form No. FSHC1217WM-0515
English
NOTICE
CAUTION
WARNING
WARNING
IMPORTANT SAFETY INFORMATION
Read the following important safety information before using this equipment to avoid serious injury or death and to avoid damage to equipment or property
.
ELECTRIC SHOCK HAZARD:
• Plug unit into a properly grounded electrical receptacle of the correct voltage, size, and plug configuration. If plug and receptacle do not match, contact a qualified electrician to determine and install proper voltage and size electrical receptacle.
• Turn OFF power switch, unplug power cord, and allow unit to cool before performing any cleaning, adjustments, or maintenance.
• DO NOT submerge or saturate with water. Unit is not waterproof. Do not operate if unit has been submerged or saturated with water.
• Unit is not weatherproof. Locate unit indoors where ambient air temperature is a minimum of 70°F (21°C).
• This unit is not “jet-proof” construction. Do not use jet­clean spray to clean this unit.
• Do not steam clean or use excessive water on unit.
• Turn power switch OFF and allow unit to cool before draining water pan.
• Do not pull unit by power cord.
• Discontinue use if power cord is frayed or worn.
• Do not attempt to repair or replace a damaged power cord. Cord must be replaced by Hatco, an Authorized Hatco Service Agent, or a person with similar qualifications.
• This unit must be serviced by qualified personnel only. Service by unqualified personnel may lead to electric shock or burn.
• Use only Genuine Hatco Replacement Parts when service is required. Failure to use Genuine Hatco Replacement Parts will void all warranties and may subject operators of the equipment to hazardous electrical voltage, resulting in electrical shock or burn. Genuine Hatco Replacement Parts are specified to operate safely in the environments in which they are used. Some aftermarket or generic replacement parts do not have the characteristics that will allow them to operate safely in Hatco equipment.
FIRE HAZARD: Locate unit a minimum of 1″ (25 mm) from combustible walls and materials. If safe distances are not maintained, combustion or discoloration could occur.
Make sure food product has been heated to the proper food-safe temperature before placing in unit. Failure to heat food product properly may result in serious health risks. This unit is for holding pre-heated food product only.
Hatco Corporation is not responsible for actual food product serving temperature. It is the responsibility of the user to ensure that food product is held and served at a safe temperature.
Make sure all operators have been instructed on the safe and proper use of the unit.
This unit is not intended for use by children or persons with reduced physical, sensory, or mental capabilities. Ensure proper supervision of children and keep them away from the unit.
This unit has no “user-serviceable” parts. If service is required on this unit, contact an Authorized Hatco Service Agent or contact the Hatco Service Department at 800-558-0607 or 414-671-6350; fax 800-690-2966; or International fax 414-671-3976.
BURN HAZARD:
• Some exterior surfaces on unit will get hot. Use caution when touching these areas.
• Turn off unit and allow it to cool before draining water from water pan.
Locate unit in an area that is convenient for use. The location should be level to prevent unit or its contents from falling accidentally and strong enough to support the weight of the unit and contents.
Do not overfill water pan. Overfilling can cause water to leak onto floor and create a slipping hazard.
Transport unit in upright position only. Make sure all water is drained prior to transport.
Do not lay unit on side with control panel or damage to unit could occur. Make sure all water is drained prior to laying unit on its side.
Use non-abrasive cleaners and cloths only. Abrasive cleaners and cloths could scratch finish of unit, marring its appearance and making it susceptible to soil accumulation.
Use of distilled water in water reservoir of humidified units is recommended. If non-distilled water is used, reservoir will require periodic cleaning and deliming (refer to MAINTENANCE section for cleaning procedure). Damage to unit caused by liming or sediment buildup is not covered under warranty.
Clean unit daily to avoid malfunctions and maintain sanitary
operation. Do not locate unit in area with excessive air movement
around unit. Avoid areas that may be subject to active air movements or currents (i.e., near exhaust fans/hoods, air conditioning ducts, and exterior doors).
Form No. FSHC1217WM-0515
3
MODEL DESCRIPTION
FSHC-12W1 FSHC-12W2
FSHC-17W1 FSHC-17W2
FSHC-17W2D
FSHC-17W1D
English
All Models
Flav-R-Savor®Tall Humidified Holding Cabinets are made from sturdy stainless steel with tubular frame welded construction. Features include a digital temperature controller and Lexan door(s) or insulated stainless steel door(s). The door(s) can be hinged left or right. Electrical components, controls, and the water pan are easily accessible. Units are equipped with locking swivel casters for easy portability. An attached 10′ (3048 mm) power cord and plug is standard.
Model FSHC-12W1
The FSHC-12W1 is a single door, upright model. Universal tray slides are included that will accommodate twelve 18″ x 26″ (457 x 660 mm) sheet pans or twenty-four 12″ x 20″ x 2-1/2″ (305 x 508 x 64 mm) hotel steam pans on 3″ (76 mm) centers.
Model FSHC-12W2
The FSHC-12W2 has all the features of the FSHC-12W1 but is equipped with two (2) full doors, one on each side of the unit for pass-through operation.
Model FSHC-17W1
The FSHC-17W1 is a single door, upright model. Universal tray slides are included that will accommodate seventeen 18″ x 26″
®
(457 x 660 mm) sheet pans or thirty-four 12″ x 20″ x 2-1/2″ (305 x 508 x 64 mm) hotel steam pans on 3″ (76 mm) centers.
Model FSHC-17W1D
The FSHC-17W1D has all the features of the FSHC-17W1 but is equipped with two (2) 1/2 size doors for enhanced performance characteristics.
Model FSHC-17W2
The FSHC-17W2 has all the features of the FSHC-17W1 but is equipped with two (2) full doors, one on each side of the unit for pass-through operation.
Model FSHC-17W2D
The FSHC-17W2D has all the features of the FSHC-17W2 but is equipped with a total of four (4) doors — two (2) 1/2 sized doors on both the front and back side of the unit for pass­through operation and enhanced performance characteristics.
FSHC-12W Series
FSHC-17W Series
4
Form No. FSHC1217WM-0515
English
WARNING
NEMA 5-15P
CEE 7/7 Schuko
BS-1363
NEMA 6-15P
NEMA 5-20P
F S H C - X X W X D
Flav-R-Savor
Holding Cabinet
Full Size Sheet Pan
Capacity
Wide Cabinet Capacity
Dutch Doors 1 = Front Door Only
2 = Pass-Through Doors
Plug Configuration
Units are supplied from the factory with an electrical cord and plug installed.
ELECTRIC SHOCK HAZARD: Plug unit into a properly grounded electrical receptacle of the correct voltage, size, and plug configuration. If the plug and receptacle do not match, contact a qualified electrician to determine and install the proper voltage and size electrical receptacle.
NOTE: The specification label is located on the right side of the
unit when facing controls. See label for serial number and verification of unit electrical information.
Electrical Rating Chart
MODEL DESIGNATION
SPECIFICATIONS
Plug Configurations
NOTE: Receptacle not supplied by Hatco.
Model Voltage Watts Amps Hertz Plug Configuration Shipping Weight
FSHC-12W1 120 1650 13.8 60 NEMA 5-15P * 288 lbs. (130 kg)
208–240 1608–2133 7.7–8.9 60 NEMA 6-15 288 lbs. (130 kg)
220–240 1800–2142 8.2–8.9 50 CEE Schuko, BS-1363, or No Plug 288 lbs. (130 kg)
FSHC-12W2 120 1650 13.8 60 NEMA 5-15P * 318 lbs. (144 kg)
208–240 1608–2133 7.7–8.9 60 NEMA 6-15 318 lbs. (144 kg)
220–240 1800–2142 8.2–8.9 50 CEE Schuko, BS-1363, or No Plug 318 lbs. (144 kg)
FSHC-17W1 120 1650 13.8 60 NEMA 5-15P * 340 lbs. (154 kg)
208–240 1608–2133 7.7–8.9 60 NEMA 6-15 340 lbs. (154 kg)
220–240 1800–2142 8.2–8.9 50 CEE Schuko, BS-1363, or No Plug 340 lbs. (154 kg)
FSHC-17W1D 120 1650 13.8 60 NEMA 5-15P * 340 lbs. (154 kg)
208–240 1608–2133 7.7–8.9 60 NEMA 6-15 340 lbs. (154 kg)
220–240 1800–2142 8.2–8.9 50 CEE Schuko, BS-1363, or No Plug 340 lbs. (154 kg)
FSHC-17W2 120 1650 13.8 60 NEMA 5-15P * 340 lbs. (154 kg)
208–240 1608–2133 7.7–8.9 60 NEMA 6-15 340 lbs. (154 kg)
220–240 1800–2142 8.2–8.9 50 CEE Schuko, BS-1363, or No Plug 340 lbs. (154 kg)
FSHC-17W2D 120 1650 13.8 60 NEMA 5-15P * 340 lbs. (154 kg)
208–240 1608–2133 7.7–8.9 60 NEMA 6-15 340 lbs. (154 kg)
220–240 1800–2142 8.2–8.9 50 CEE Schuko, BS-1363, or No Plug 340 lbs. (154 kg)
* NEMA 5-20P for Canada
Form No. FSHC1217WM-0515
The shaded areas contain electrical information for International models only.
5
SPECIFICATIONS
C
C
A
AB B
1 Door Models
2 Door Models
D D
C
A B
Dutch Door Models
D
D
Dimensions — FSHC-12W and FSHC-17W Series
English
Width
Model
FSHC-12W1
FSHC-12W2
FSHC-17W1
FSHC-17W1D
FSHC-17W2
FSHC-17W2D
Cabinet Opening: FSHC-12W Series: 22″W x 43-1/2″H (559 x 1105 mm) FSHC-17W Series: 22″W x 59-3/4″H (559 x 1518 mm) Dimensions for units with Transport Package, Bumpers, and Handles:
FSHC-17W Series: 31-1/2″W x 36-1/2″D (800 x 927 mm).
(A)
26″
(659 mm)
26″
(659 mm)
26″
(659 mm)
26″
(659 mm)
26″
(659 mm)
26″
(659 mm)
Depth
(B)
34-3/4″
(883 mm)
35-1/8″
(892 mm)
34-3/4″
(883 mm)
34-3/4″
(883 mm)
35-1/8″
(892 mm)
35-1/8″
(892 mm)
57-5/16″
(1455 mm)
57-5/16″
(1455 mm)
(1869 mm)
(1869 mm)
(1869 mm)
(1869 mm)
Height
(C)
73-5/8″
73-5/8″
73-5/8″
73-5/8″
Door Height
(D)
44-3/16″
(1122 mm)
44-3/16″
(1122 mm)
60-1/2″
(1534 mm)
30″
(761 mm)
60-1/2″
(1534 mm)
30″
(761 mm)
6
Form No. FSHC1217WM-0515
English
10″ (254 mm)
Transport Package Dimensions
38-3/4″
(984 mm)
31-1/2″
(800 mm)
36-1/2″
(927mm)
Cord Wind Bracket
Depth:
1-1/8″
(28 mm)
Dimensions — Transport Package Option
SPECIFICATIONS
Transport Package Dimensions
Form No. FSHC1217WM-0515
7
INSTALLATION
WARNING
CAUTION
NOTICE
Lexan
Reversible
Door
Control Panel
Shelf Supports (4)
Magnetic
Handle
Recessed Cord and Plug
5” (127 mm) Heavy Duty Casters
Heat Tunnel
Water Pan
Drip Trough
Adjustable
Tray Slides
(shown assembled
to Shelf Supports)
Heat
Element
Assembly
(underneath
Heat Tunnel)
®
General
The Flav-R-Savor®Tall Humidified Holding Cabinets are shipped with most components installed and ready for operation. The following installation instructions must be performed before plugging in and operating the cabinet.
English
Locate unit in an area that is convenient for use. The location should be level to prevent unit or its contents from falling accidentally and strong enough to support the weight of the unit and contents.
ELECTRIC SHOCK HAZARD: Unit is not weatherproof. Locate the unit indoors where the ambient air temperature is a minimum of 70°F (21°C).
FIRE HAZARD: Locate unit a minimum of 1″ (25 mm) from combustible walls and materials. If safe distances are not maintained, combustion or discoloration could occur.
Do not locate unit in area with excessive air movement around unit. Avoid areas that may be subject to active air movements or currents (i.e., near exhaust fans/hoods, air conditioning ducts, and exterior doors).
1. Remove the unit from the carton.
2. Remove all loose items shipped inside the cabinet such as the box containing the adjustable tray slides, the casters/legs, etc...
NOTE: FSHC-12 Series: Quantity 24 Tray Slides
FSHC-17 Series: Quantity 34 Tray Slides
Cabinet Components Exploded View
8
Form No. FSHC1217WM-0515
English
NOTICE
Handle
Strike
Plate
Hinge Cover
Hinge
Screws
INSTALLATION
NOTE: To prevent delay in obtaining warranty coverage,
NOTE: Refer to the OPTIONS AND ACCESSORIES section in
Do not lay unit on side with control panel or damage to unit could occur. Make sure all water is drained prior to laying unit on its side.
NOTE: Place a piece of cardboard between the cabinet and the
complete online warranty registration. See the IMPORTANT OWNER INFORMATION section for details.
3. Remove tape and protective packaging from all surfaces of the unit.
this manual for options and accessories instructions.
4. Install the 5″ (127 mm) casters onto the bottom of the cabinet.
a. Remove all shelf supports, tray slides, heat tunnel, and
water pan.
b. Carefully lay the unit on its back side. This step requires
two people.
floor to prevent marring the cabinet finish.
c. Install the two swivel casters to the front of the unit using
four mounting screws (provided). Tighten securely.
d. Install the two stationary casters to the back of the unit
using four mounting screws (provided). Tighten securely.
e. Return the unit to its upright position. This step requires
two people.
5. Install the heat tunnel and water pan.
6. Unpack the adjustable tray slides from the box and install them inside the cabinet. There are 12 or 17 adjustable tray slides for each side of the cabinet. Four shelf supports, two on each side of the cabinet, support the tray slides.
To install each tray slide:
a. Align the hooks at each end of the tray slide with the
desired slots on the front and rear shelf supports.
b. Angle the tray slide hooks into the slots and let the tray
slide rotate down into position.
7. Place the unit in the desired location.
• Locate the unit in an area where the ambient air temperature is constant and a minimum of 70°F (21°C). Avoid areas that may be subject to active air movements or currents (i.e., near exhaust fans/hoods and air conditioning ducts).
• Make sure the unit is located on solid, level flooring.
• Make sure the unit is at the proper height in an area
convenient for use.
Reversing the Access Door
The access door is field reversible to allow it to be hinged on either the right or left side. Use the following procedure to reverse the door.
1. Remove the four handle screws securing the handle to the door. Remove the handle.
2. Slide the hinge covers off of the door hinges.
3. At each door hinge, remove the three hinge screws that secure the hinges to the cabinet frame. Remove the access door.
NOTE: The hinges remain mounted to the access door.
4. Transfer the screw plugs from the hinge screw holes on the opposite side of the cabinet to the open holes where the hinges were just removed.
5. Remove the two strike plate screws that secure the strike plate to the cabinet.
6. Transfer the screw plugs from the strike plate holes on the opposite side of the cabinet to the open holes where the strike plate was just removed.
7. Install the strike plate on the opposite side of the cabinet using the original hardware.
8. Rotate the door 180° and install on the opposite side of cabinet using the original hardware.
9. Install the handle to the door in the upright position using the original hardware.
10. Slide the hinge covers back into place on the door hinges.
Form No. FSHC1217WM-0515
Reversing the Access Door
9
OPERATION
WARNING
NOTICE
CAUTION
WARNING
CAUTION
General
Use the following procedures to operate a Flav-R-Savor®Tall Humidified Holding Cabinet.
Read all safety messages in the IMPORTANT SAFETY INFORMATION section before operating this equipment.
Startup
1. Plug the unit into a properly grounded electrical receptacle of the correct voltage, size, and plug configuration. See the SPECIFICATIONS section for details.
Use of distilled water in water reservoir of humidified units is recommended. If non-distilled water is used, reservoir will require periodic cleaning and deliming (refer to MAINTENANCE section for cleaning procedure). Damage to unit caused by liming or sediment buildup is not covered under warranty.
2. Fill the water pan with clean water. To fill the water pan:
a. Open the access door. b. Slowly pour water into the water pan until the water level
reaches the fill line on the back of the pan. Do not fill water above this line.
c. Close the access door.
NOTE: Clean the water pan daily to extend the life of the
electrical and mechanical components and to keep cleaning easy. If “hard” water is used, the pan will require periodic cleaning and de-liming. Refer to the MAINTENANCE section for de-liming instructions.
English
BURN HAZARD: Some exterior surfaces on the unit will get hot. Use caution when touching these areas.
4. Set the air temperature to the desired temperature (refer to the “Setting the Air Temperature” procedure in this section). See the “Food Holding Guide” for recommendations.
5. On humidified units, set the humidity to the desired level (refer to the “Setting the Humidity Level” procedure in this section). See the “Food Holding Guide” for recommendations.
NOTE: Temperature and humidity settings may vary depending
upon product make-up and consistency. The CABINET TEMPERATURE display shows the lowest temperature point inside the cabinet, not the product temperature.
Allow 30-45 minutes to preheat the cabinet with a full pan of water before loading preheated food product.
NOTE: Operating at a high humidity setting for extended
periods of time may require the drip trough(s) to be emptied periodically (located at the bottom of the door).
Make sure food product has been heated to the proper food-safe temperature before placing in unit. Failure to heat food product properly may result in serious health risks. This unit is for holding pre-heated food product only.
Shutdown
1. Move the POWER ON/OFF (I/O) Switch to the OFF (O) position and allow the unit to cool.
2. Perform the “Daily Cleaning” procedure in the MAINTENANCE section of this manual.
Do not overfill water pan. Overfilling can cause water to leak onto floor and create a slipping hazard.
NOTE: On the initial fill, the capacity of the water pan is
approximately two (2) gallons (7.6 liters).
3. Move the POWER ON/OFF (I/O) switch to the ON (I) position. The heating system will start up.
Control Panel
10
Form No. FSHC1217WM-0515
English
OPERATION
Setting the Air Temperature
Use the following procedure to set or change the air temperature.
1. Press the key to enter temperature mode (“tSP” will appear on the CABINET TEMPERATURE display).
2. Press the key again to show the current temperature setting.
3. Press the key or key to reach the desired temperature. The temperature range is 80°–200°F (27°–93°C) in single degree increments. See the “Food Holding Guide” in this section for recommendations.
4. After the desired temperature is set, wait 15 seconds without pushing any keys for the cabinet temperature display to return automatically to operational mode.
Setting the Humidity Level
Use the following procedure to set the humidity level on humidified units.
1. Press the key to enter humidity mode (“hSP” will appear on the CABINET TEMPERATURE display).
2. Press the key again to show the current humidity level.
3. Press the key or key to reach the desired humidity level. Humidity range is 0 through 5 (1 is the lowest amount of humidity and 5 is the highest, 0 is no humidity). See the “Food Holding Guide” in this section for recommendations.
4. After the desired humidity level is set, wait 15 seconds without pushing any keys for the cabinet temperature display to return automatically to operational mode.
Setting the Humidity Level
Setting the Air Temperature
NOTE: Temperature and humidity settings may vary depending
upon product make-up and consistency. The CABINET TEMPERATURE display shows the lowest temperature point inside the cabinet, not the product temperature.
The water pan capacity permits uninterrupted operation for approximately 4-8 hours, depending on the humidity and temperature settings as well as how frequently the door is opened. WARNING! Electric Shock Hazard — Do not overfill
water reservoir.
Food Holding Guide
Type of Food
Biscuits 4 Hours 3 140 60
Chicken Pieces (Fried) 4 Hours 1 170 77
Croissants 4 Hours 1 140 60
Fruit Pies 3-1/2 Hours 3 140 60
Onion Rings 1/2 to 2 Hours 1 180 82
Pizza — Thick Crust
Thin Crust
Pretzels 3 Hours 3 140 60
Wrapped Sandwiches 2 Hours 3 170 77
Maximum
Holding Time
1 Hour 1 Hour
Humidity
Setting
1 2
Air Temperature Setting
°F °C
185 180
85 82
NOTE: All times and settings are recommendations only and may vary depending on product preparation, cooking time, internal
Form No. FSHC1217WM-0515
food temperature, location of unit in operation, geographic region of particular operation, and frequency of door openings.
11
Loading...
+ 25 hidden pages